Tender For Modernization Of F&V Market At Narwal Jammu (Under Nabard).
Tender Value
9.69 Crore
Estimated cost
Bid Submission
27 Jul 2026
15 days left
EMD
19.38 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kathua → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Modernization Of F&V Market At Narwal Jammu (Under Nabard).
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres. All kinds of soil. |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for :- |
| 7 | Foundations, footings, bases of columns etc. for mass concrete. |
| 8 | Suspended floors, roofs, landings, balconies and access platforms. |
| 9 | Edges of slabs and breaks in floors and walls above 20 cm wide. |
| 10 | Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs and steps etc. |
| 11 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 12 | Providing & laying water bound macadam with specified stone aggregate screening and binding material including screening, sorting to template and consolidation with power road roller 80-100 KN capacity. Base course with 63mm – 45mm size including screening 13.20mm size in two layers of 75mm thick (consolidated) each. |
| 13 | Providing and laying Semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equip⁰ed with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. 25 mm compacted thickness with bitumen of grade VG- 30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity. |
| 14 | Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge.50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 3.5% (percentage by weight of total mix) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity. |
| 15 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 16 | Providing and applying tack coat using hot straight run bitumen of grade–VG-30, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. On WBM @ 0.75 Kg/sqm. |
| 17 | Providing and applying tack coat using hot straight run bitumen of grade–VG-30, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications. On bitumen surface @ 0.50 Kg/sqm. |
| 18 | Engaging Assistant Welder for dismantling existing steel railing from existing wall along park side. |
| 19 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge in cement mortar. |
| 20 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil. |
| 21 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts andstruts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 22 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 23 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete. |
| 24 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre. |
| 25 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 26 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 27 | 12mm Cement plaster of mix 1 : 6 (1 cement : 6 coarse sand). |
| 28 | White washing with lime to give an even shade on New Work (three or more coats). |
| 29 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 30 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 meter openable length ( total length 90m), having 50 nos rounds per 6 meter length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape (R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ meter (cost of M.S. angle, C.C. blocks shall be paid separately). |
| 31 | Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 meters (minimum), between the two posts fitted and fixed with G.I.staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per meter cost of total length of barbed wire used. With G.I. barbed wire. |
| 32 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 33 | Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete. |
| 34 | Stone agg. / Screening / C. Dust / Sand for an avg. lead of 20 Kms. |
| 35 | Disposal of excavated earth / mulba for an average lead of 10 Kms. |
| 36 | Bricks for an avg. lead of 20 Kms. |
| 37 | Electrical Works :- |
| 38 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.Make PANASONIC PROF LIGHTING, TRILUX, OSRAM, PHILLIPS |
| 39 | LED Street Light fixture with Minimum lumen output 12500 lm |
| 40 | LED Street Light fixture with Minimum lumen output 25000 lm |
| 41 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.Make PANASONIC PROF LIGHTING, TRILUX, OSRAM, PHILLIPS |
| 42 | High Power LED Flood Light Minimum lumen output 12400 lm |
| 43 | High Power LED Flood Light Minimum lumen output 18650 lm |
| 44 | High Power LED Flood Light Minimum lumen output 37500 lm |
| 45 | Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge. 9 Mtr.Make TRANSRAIL, BAJAJ, VALMONT |
| 46 | Supplying, installation, testing & commissioning of IP65 protected ornamental/ decorative type 3 Mtrs. pole top mounted 40-50 watt snowdrop single arm ornamental LED post top luminarie made of powder coated die cast alluminium housing with UV stabalized clear / frosted polycarbonate diffuser and aluminium anodised with sand blast reflector, The system level luminous efficiency > 100 Lumen/W. SMD LEDs is to be used, system CRI> 70, CCT: 3000/4000/6500 K. The inteegral electronic driver must be potted & has aunique BIS R number must be potted & has a unique BIS R number constant current and internal/external surge protection device of min 4 KV(L-N) and efficiency>85%, PF>0.9, THD<10% and input voltage range of 140-270V AC at 50 Hz. System life of 50000 burning hours with 70% if initial lumens maintained. Driver current < 750mA. Fixture must have BIS standards and trade make certificatecomplete in all respect. (LM70/LM80) certificate/report with liable warranty of product/accessories from OEM shall be submitted. Design of Pole as approved by engineer-in-charge. |
| 47 | Providing of Cement concrete block (1:3:6) suitable for erecting cast iron pole on it including grouting of foundation bolts. Concrete depth underground shall be 2.50 ft. and 10\\" above ground. Job includes cable entries fabricated out of 50 mm dia DWC/HDPE PN10/PN8 ISI marked pipe riser at the ground level of poles for looping out of cables and curing and form work.Construction of Plaftrom with P.C.C of M-10 P.C.C Grade (1:3:6) 1 Cement, 3 Sand, 6 crushed course Stone agg. including earthwork as directed by the Engineer-in-charge with a floating coat of neat cement slurry on top and plastering the exposed sides with cement mortar 1:4 with uniform thickness and finish as per the directions of Engineer -In-Charge complete in all respects. |
| 48 | Supply,Installation,Testing and Commissioning with transportation at site of 1 No. 11 mtr High Mast Pole suitable for 6 Nos. Luminaries installation symmetrically alongwith junction box, cross arm/ suitable ring for Luminaires including foundation accessories. The High Mast pole shall have an intigral power tools installed inside the base compartment for the operation of luminaires. Wiring with 3 x 2.5 sq.mm PVC insulated copper conductor from junction box of pole to luminaires alongwith installation charges includes in the mast supply price. The erection of pole with all accessories shall be with the help of suitable equipment or with help of modern engineering practice. The specifications of pole is as under. Length Section Bottom 5.6 Mtr. Middle 2.7 Mtr. Top 2.7 Mtr. Outside Diameter.Bottom 165.1 x 4.50 mm.Middle 139.7 x 4.50 mmTop 114.3 x 3.65 mm Make: TRANSRAIL, BAJAJ, VALMONT |
| 49 | Approx. weight of Pole 147 Kgs.Base Plate 600 x 600 x 8mmTensile Test - Tensile Strength 540 Mpa (55 Kgf/Sq.mm). And with Technical Parameters asPhysical Requirement . The material when tested in accordance with IS: 1894:1972 shall have minimum tensile strength of 42 Kgf/mm and confirming IS 1894: 1972. Protection Against Corrosion. The poles shall be coated with black bituminous paint confirm to IS 158-1968 throughout internally and externally upto the level i.e 1/6 of the total length which goes inside the earth.Tolerance. Outside diameter of poles as nearly circular as possible and their diameter shal l not vay by more than 1%.Earthing. Nut 10 mm dia shall welded on pole at the height of 400 mm from planting depth. The job including provided & fixing of 3C x 2.5 sq. mm copper cable also. |
| 50 | Steel should be of good quality of weight 7.85 g/cum factor of safety on cripplilating load 2 and factor of safety on breaking load is 2.5 size of the base plate duly welded at bottom. The mast shall have 4 No 32 mm dia wholes at 2.54 above the base plate suitable to accommodates 6 to 8 Nos. of 3 core x 2.5 sq.mm Cu conductor cables from control panel to luminaries dia of adjustable ring = 1800mm dia of the steel pipe of the ring =50 mm 4Nos. of support of 50mm dia pipe duly welded between inner periphery of the ring and the cap. The pole is to be errected in c. concretc in the ratio of 1:2:4 mix. The fondation is to be continued upto 2' above groung level in square/round shape. The length and diameter of the cap of the adjustable ring is such that showed be well fixed in top of the mast and give an overall aesthetic look to the mast. The cap of the ring shall have 6 Nos. holes welded suitably with 6 Nos. nuts to facilitate tightening of the top of the mast. |
| 51 | Supplying & laying of 1.1 kv grade PVC insulated and PVC sheathed XPLE armoured Aluminium conductor cables of 16 Sq.mm 3 CORE including excavation of earth and refilling the same after laying the cable.Make GRANDLAY, POLYCAB, HAVELLS, RR |
| 52 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.Make GRANDLAY, POLYCAB, HAVELLS, RR |
| 53 | 3 x 1.5 sq. mm |
| 54 | 3 x 2.5 sq. mm |
| 55 | Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) .Make GRANDLAY, POLYCAB, HAVELLS, RR |
| 56 | 10 sq. mm 3.5 core |
| 57 | 25 sq. mm 3.5 core |
| 58 | 35 sq. mm 3.5 core |
| 59 | Supplying and fixing of Marshalling Box for Street Light Pole 200 x 250 x 100 mm 1.6 sheet thickness including 6/10 amp. MCB complete in all respect. |
| 60 | Supplying & laying of G.I pipe 50 mm diameter |
| 61 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. HDPE PIPE 63 mm dia (OD-63 mm & ID-51 mm nominal).Make REX ,ASTRAL, GEMINI |
| 62 | Supplying and fixing of following rating 240/415 volts \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make ABB, SCHNEIDER(ACTI-9), LEGRAND(EKINOX) |
| 63 | Single pole upto 6 to 32 Amp |
| 64 | MCB SPN FP 40 Amp |
| 65 | MCB SPN FP 63 Amp |
| 66 | Providing installation, testing and commissioning of Double Door type main panel made of CRCA Sheet outdoor type, cubical feeder panel with 1.6 mm thick sheet painted from inside and outside to provide complete protection from water moisture, dust and vermin proof, duly wired up with the following accessories/equipment.MCCB FP 63 amp 25 KA = 1 No.Metering and Indication Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set, MCB strips for required Nos. of MCB etc. = 1 setAluminum BusbarHigh conductive electrolytic grade aluminium busbar of 240 Amp, TPN, with heat shrinkable sleeve, duly colour coded. =1 SetTimer Switcha) Timer Switch = 1 No.b) MCB 6 amp to 32 amp = 8 Nos.c) 1 x 1.5 sq. mm = 10 Mtrs. Make D-TECH INDUSTRIES, JAIMA ELECTRIC, ELECTRICFIELD |
| 67 | SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.Make D-TECH INDUSTRIES, JAIMA ELECTRIC, ELECTRICFIELD |
| 68 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) Make ABB, SCHNEIDER(ACTI-9), LEGRAND(EKINOX) |
| 69 | 100 Amp, 30 KA, FP MCCB ICU = 100% ICS |
| 70 | 63 Amp, 25 KA, FP MCCB ICU = 100% ICS |
| 71 | 40 Amp, 25 KA, FP MCCB ICU = 100% ICS |
| 72 | ON Load Change Over Switch FP 100 amp. (Front operated) |
| 73 | Aluminium Bus Bar 200 Amp set of 4 strips |
| 74 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 75 | Design, manufacture and supply of indoor type of three phase 415 volt LT unbalanced 63 KVA servo controlled automatic voltage stabilizer copper wound oil cooled type designed for input voltage 160 V to 450 V phase to phase and output voltage 415 V ± 1% phase to phase and 230 volt ± 1% phase to neutral and frequency 50 HZ +/- 3%. The no load current shall not be more than 5% of the rated output current. The stabilizer shall be totally powder coated from outside to have aesthetic outlook and inside of tank should be zinc chromate painted. Panel should be screen-printed. The unit shall be housed in sheet steel of 14 gauge thickness having wheels with sturdy construction to withstand the rigorous shifting movement, repair works and handling. The unit shall be supplied with first filling of fresh filtered transformer oil having dielectric strength and shall be suitable for unbalanced input voltage and unbalanced output load . PROTECTIONS - Under voltage , over voltage , short circuit, overload and surge protection through suitable capacity MCCB BYPASS ARRANGEMENT - Bypass arrangement shall be provided through suitable capacity bypass switch and complete with cement concrete platform of required size as per instruction of Engineer in-charge and RiTES/CEIL (Tested) Certificate in this respect to be submitted. The job includes CAMC for 1 Years after DLP of 1 Year. Make D-TECH INDUSTRIES, JAIMA ELECTRIC, ELECTRICFIELD |
| 76 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make).Make AKG, ASTRAL, STEELKRAFT, PERCISION |
| 77 | 25 mm |
| 78 | 40 MM |
| 79 | Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover. Make TRUEPOWER, OBO BETTERMANN, INGESCO, VNT |
| 80 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 81 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 82 | Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover. |
| 83 | Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. |
| 84 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 85 | Supply, intastallation, testing & commissioning of 63 KVA Capacity (CPCB-IV) silent D.G set radiator cooled DG Set with suitable capacity engine directly coupled with alternator for 415 volt, 3 phase, 50 Hz, minimum 74 BHP at 1500 RPM, generation system complete with accessories, fuel oil tank & control panel etc as required and sound proof acquastic enclosure for the DG SET, including supply, fixing of antivibration pads suitable for 63 KVA DG Set as per standards of Engine manufacture, provision of conrol cable from engine to control panel to engine. Provision of pipe fuel pipe line of suitable size fron fuel tank to engine and over flow pipe engine to fuel tank complete gate valve and fitting leader maker etc. Supply , Intallation of starting batteries of suitable AH as recommended by manufacterer Heavy duty complete as required at site complete with stand and battery charger residentials sylencer sutaible for diesel engine exhaust pipe line complete complete flange, bend, flexible pipe all as required and as directed by engineer incharge including AMF Panel.Make MAHINDRA, CATERPILLAR, CUMMINS, KIRLOSKAR |
| 86 | DIESEL ENGINE 4 Stroke, Radiaotr Cooled, Diesel Engine Model Having Following Arrangement :-Flywheel with Starter Ring for Generating SetAir Filter , Lube Oil Cooler Assembly with accessories.Exhaust air manifoldExhaust BellowFuel FiterLube Oil FilterExhaust Gas Turbocharger with after Coller Day tank for fuel with markingsECP Panel mounted on a separate frame. Radiator with Pusher Type Fan, With Fan Guard, Coolant Pump12V Electrical Starting System with Starter Motor and Battery Charging AlternatorEngine Mounting Supports |
| 87 | ALTERNATOR Rated at 63KVA, 415 Volts, 03 Phase, 4 Wire, 0.8 P.F (lag), 50HZ, 1500 RPM, IN Accordance with IS 4722 as per following SpecificationRating: Suitable for an over-load of 10% for 1 hour in every 12 hours operation.Voltage Regulation: Provided with fast response thyristor type electronic automatic voltage regulator, which holds output voltage within desired limits . (+/- 1%).Excitation: Self excited-self regulated.Alternator Loading: Suitable for taking rated load immediately after machine reaches rated voltage and speed.Vibration: Suitable for direct coupling with Engine and mounted on common M.S. Channel base frame.Enclosure: Screen protected drip proof enclosure with IP – 23 degree of protection. |
| 88 | Cooling: Air Cooled type with radial fan mounted on Rotor.Winding and Insulation: Insulation class H as defined in IS – 4722.ACCESSORIES :-MS Base Frame Suitable for Mounting of the Offered Engine and Alternator.Day Fuel Tank of Standard Capacity Complete Fuel Gauge, Inlet/Outlet Connections, Drains Plug, Etc2 Nos 12 Volts DC Battery of SUITABLE Capacity with Leads1 Set of AVM Pads Fitted in Base Frame. |
| 89 | Construction of PCC Platform for laying of DG set & PRE-FAB. STRUCTURE (Complete Job.) as per size and instruction of Engineer in Charge |
| 90 | Dismantling & reinstallation of existing 9 mtr/11mtrs poles complete Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge. |
| 91 | Repair of old MCCB's/s/Switch/Board etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender