Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #56349984

Tender For Irepair To 12000 Gph X 40 Meter Head Low Speed Split Casing Raw Water Hc Pump Set With 15 Kw Motor Alongwith 70 Ere Lt Control Panel Alongwith Allied Works At Pumping Station Thanova Swail Stage-0, Repair To 150 Kva Voltage Stabilizer Alon

Issued by Government Departments · Udhampur, Jammu and Kashmir
Tender Value
5 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
0 days left
EMD
10000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Irepair To 12000 Gph X 40 Meter Head Low Speed Split Casing Raw Water Hc Pump Set With 15 Kw Motor Alongwith 70 Ere Lt Control Panel Alongwith Allied Works At Pumping Station Thanova Swail Stage-0, Repair To 150 Kva Voltage Stabilizer Alongwith Allied Works At Water Supply Scheme Thanova Swail Stage-0.

BOQ

Name of Work:- IRepair to 12000 GPH x 40 meter head low speed split casing raw water HC pump set with 15 KW motor alongwith 70 ere LT control panel alongwith allied works at pumping station Thanova Swail stage-0, repair to 150 KVA voltage stabilizer alongwith allied works at WSS Thanova Swail Stage-0.
Sl. No. Item Description
1Repair to 12000 GPH x 40 meter head low speed split casing raw water HC pump set with 15 kw motor alongwith 70 ampere LT control panel alongwith allied works at pumping station Thanova Swail stage-0
2Repair to 12000 GPH x 40 meter head low speed split casing raw water with HC pump set with 15 KW motor alongwith 70 ampere LT control panel along with allied works at WSS Thanova Swail way of disconnecting of all electrical connections, decoupling of pump from motor, carrying pump-motor set from pumping station to road side by way of head load carriage and then to work shop by mechanical transportation. Dismantling pumpset and washing and cleaning of parts with thinner and Providing and fitting of new bearings as per old sample by removing the rusted bearings. providing and fitting of new gland packing, coupling bolts.Carriage of pump set back to pumping station by using manual labour tools and tackles and mechanical transport . Job further includes complete impregnation of 20 HP motor by cleaning, varnishing and replacing rusted bearing as per sample. Coupling pump motor set and making proper alignment and testing the pump set on load at site. Job further includes repair to 70 ampere LT control panel. The job involves dismantling of all the incoming and outgoing power cables from the panel and shifting to workshop. The job involves replacement of damaged mccb, motor protection relay and replacement of rusted contactor kit of 70 ampere 3 pole power contactors-2no., voltmeter, amperemeter, CTs and fuse set with new corresponding components conforming to same rating and specifications. Making of the complete internal control wiring afresh with flexible PVC copper wire of appropriate rating with proper thimbling. Testing of pump at site. Complete job includes cost of material, labour charges including to and fro carriage / loading / unloading charges.
3Repair to 150 kva voltage stabilizer alongwith allied works at WSS Thanova Swail stage-0
4Repair to 150 KVA voltage stabilizer at WSS Thanova Swail stage-0 by way of disconnecting all electrical connections and making temporary arrangement for running of system. Dragging the stabilizer outside the pump room by deploying manual labour and with the help of tools tackles. Shifting of voltage stabilizer to workshop Unfastening of nuts bolts and opening the top cover and then dismantling of complete unit by way of chain pulley block, tripod stand to draw out 03 no. coils and shifting to workshop. Servicing of 03 nos. coils with cleaning, heating and varnishing and shifting back to site. Filling of 250 liters transformer oil in the voltage stabilizer. Replacement of voltmeter, ampere meter, selector switches and rotary switches-3nos. Lowering the internal assembly inside the chamber and closing the top cover. Providing and fitting of 300 ampere Bus bar and 250 ampere, 50 KA MCCB on wall of pump room. Making aluminum cable connections upto Bus bar and suitable rating copper cable from bus bar to MCCB and voltage stabilizer. Making all incoming and outgoing electrical connections. Testing the stabilizer on no load at least for 6 hours and then on full load. Complete job includes cost of material, labour charges, hire charges of tools and tackles etc. (complete Job). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56349984
AUTHORITY Government Departments
TENDER VALUE 5 Lakhs
LAST DATE 14-07-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Irepair To 12000 Gph X 40 Meter Head Low Speed Split Casing Raw Water Hc Pump Set With 15 Kw Motor Alongwith 70 Ere Lt Control Panel Alongwith Allied Works At Pumping Station Thanova Swail Stage-0, Repair To 150 Kva Voltage Stabilizer Alongwith Allied Works At Water Supply Scheme Thanova Swail Stage-0.
Basic Detail
Tender No ENIT NO. 35 OF 2026-27
Bidding Type Tender
Location
City Udhampur
State Jammu and Kashmir
Key Dates
Publish Date 07 Jul 2026
Submission Date 14 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 5 Lakhs
Tender Fee 500
EMD 10000
Exemption Not Available
Document List
23eeeff6-8bab-400c-a74c-0d3f95c247da.html
BOQ_1020313.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

23eeeff6-8bab-400c-a74c-0d3f95c247da.html

xls

BOQ_1020313.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders