Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Biennial Rate Contract For Monitoring Of Ambient Air Quality Within Rcf Thal Unit, And Monitoring Of Ambient Air Quality And Noise Fo
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Biennial Rate Contract For Monitoring Of Ambient Air Quality Within Rcf Thal Unit, And Monitoring Of Ambient Air Quality And Noise For Nearby Surrounding .. - Monitoring Quality Of Ambient Air Within Factory Premises (One S Le Is Of 8 Hour) I.E 48 Hours, At Four Different Locations For (So2 , Nox, Nh3 , Pm-10 And Pm-2.5 ) .(Fortnightly) , Village Ambient Air Quality Monitoring For (One S Le Is Of 8 Hour) I.E 48 Hours, At 7 Locations For (So2 , Nox, Nh3 , Pm-10, Pm 2.5,Methane,Benzene,Co,Lead,Ozone,Nickel , Arsenic And Benzo (Α) Pyrene (Bap) -Particulate Phase Only ) , Monitoring Of Noise For 7 Locations, Report Should Be Made As Per 16 Hrs Day ( 6.00 Am To 22.00 Pm) And 8 Hrs Night ( 22.00 Pm To 06.00 Am ) With Uom Db(A) Leq (Kindly Consider One S Le For 8 Hrs) , Optional Monitoring On Quarterly Basis For Ambient Air For 24 Hrs. At 7 Locations For (Methyl Hydrocarbon,Respirable Particulate Matter,Carbon Monoxide,Nonmethyl Hydrocarbon And Aldehydes)
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Monitoring quality of ambient air within factory premises (one sample is of 8 hour) i.e 48 hours, at four different locations for (SO2 , NOx, NH3 , PM-10 and PM-2.5 ) .(Fortnightly) | Monitoring quality of ambient air within factory premises (one sample is of 8 hour) i.e 48 hours, at four different locations for (SO2 , NOx, NH3 , PM-10 and PM-2.5 ) .(Fortnightly) |
| 2 | Village ambient air quality monitoring for (one sample is of 8 hour) i.e 48 hours, at 7 locations for (SO2 , NOx, NH3 , PM-10, PM 2.5,Methane,Benzene,CO,Lead,Ozone,Nickel , Arsenic and Benzo (α) Pyrene (BaP) -Particulate phase only ) | Village ambient air quality monitoring for (one sample is of 8 hour) i.e 48 hours, at 7 locations for (SO2 , NOx, NH3 , PM-10, PM 2.5,Methane,Benzene,CO,Lead,Ozone,Nickel , Arsenic and Benzo (α) Pyrene (BaP) -Particulate phase only ) |
| 3 | Monitoring of Noise for 7 locations, Report should be made as per 16 hrs Day ( 6.00 AM to 22.00 PM) and 8 hrs Night ( 22.00 PM to 06.00 AM ) with UOM dB(A) Leq (Kindly consider one sample for 8 hrs) | Monitoring of Noise for 7 locations, Report should be made as per 16 hrs Day ( 6.00 AM to 22.00 PM) and 8 hrs Night ( 22.00 PM to 06.00 AM ) with UOM dB(A) Leq (Kindly consider one sample for 8 hrs) |
| 4 | Optional monitoring on Quarterly basis for Ambient Air for 24 hrs. at 7 locations for (Methyl Hydrocarbon,Respirable Particulate Matter,Carbon Monoxide,Nonmethyl Hydrocarbon and Aldehydes) | Optional monitoring on Quarterly basis for Ambient Air for 24 hrs. at 7 locations for (Methyl Hydrocarbon,Respirable Particulate Matter,Carbon Monoxide,Nonmethyl Hydrocarbon and Aldehydes) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender