Public Administrative Department Government Departments Closing in 4 days TDR #56344762

Tender For General-Vadakarapathy Gp - 2025 - 26 - Project No. 166/26 - Setting Of Waste Treatment Plant - Electrification-Electrical Work-General Electrical Work

Issued by Government Departments · Palakkad, Kerala
Tender Value
2.31 Lakhs
Estimated cost
Bid Submission
15 Jul 2026
4 days left
EMD
555
Bank guarantee accepted
Document Fee
5785
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Palakkad → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for General-Vadakarapathy Gp - 2025 - 26 - Project No. 166/26 - Setting Of Waste Treatment Plant - Electrification-Electrical Work-General Electrical Work

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Jul-2026 fee corrigendum Fee 15-Jul-2026

BOQ

Name of Work:- GENERAL-Vadakarapathy GP - 2025 - 26 - Project No. 166/26 - Setting of Waste Treatment Plant - Electrification-Electrical work-General Electrical Work
Sl. No. Item Description
11.Electrification.
290.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
390.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
490.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
590.3.20.4:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 2X20W LED Lamp with box type fixture
6OD355329/2025-2026:Supply and fixing polyster powder coated hexagon shaped pressure die cast aluminium housing in metallic grey finish bulk head back -lit LED luminaire comprising high brightness 10w high efficiency long life LED module with SMD LED package mounted on MCPCB, powered by integral electronic LED drive with APFC with low THD out put short/open circuit protection and 4kV inbuilt surge protection. Lumen efficacy of LED >_ 140 lm/w, high quality polycarbonate UV protected diffuser in opel finish for glare free light distribution. IP 66 (Havells HEXAFT10WLED857SSYMBOPC/ EQUIVELENT MAKE) to wall/ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.
7OD355338/2025-2026:Supply Conveyance, installation, testing and commissioning of 30W LED Flood light, output 100 lumen/W 6500K with IP 66 protection with power factor 0.90 at full load, internal surge protection up to 4 KV and Aluminium pressure die-cast Powder coated housing, acrylic cover complete duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance. (Bajaj GLATT MT 36L WHPOP PC SD / Equivelent make)
890.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
990.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
10OD355344/2025-2026:Supply and providing every additional length of down rod of 15mm heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required.
1190.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
121.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
131.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
141.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
151.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
161.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
172.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
1890.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
19OD355354/2025-2026:Supply & Fixing 4 Pole enclosure MCB DB sheet steel phosphatized , painted, dust and vermin proof on surface/ recess etc. as required. 4 Pole enclosure MCB DB sheet steel phosphatized , painted, dust and vermin proof on surface/ recess etc. as required.
202.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole
21OD355342/2025-2026:Supplying and fixing 40 amps to 63 amps rating,415 volts, "C" curve,10 kA breaking capacity TPN miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
222.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
232.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps
242.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
252.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole
26OD355349/2025-2026:Supplying and fixing 40 amps to 63 amps rating,415 volts,"C" curve,10 kA breaking capacity TP miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
272.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
282.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2990.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
3090.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
3190.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
3290.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
3390.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
3490.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
3590.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
3690.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
37OD355333/2025-2026:Supply and providing12x3mm brass nut and bolt etc.as required.
38OD355352/2025-2026:Supply and providing 25 x 6 mm brass nut and bolt etc.as required.
3990.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
4090.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
4190.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
4290.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
4390.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
4490.14.7:Supply and providing copper earth bus in the panel board
452.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
462.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
472.1.4:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N
48OD355335/2025-2026:Supply,installation, testing and commissioning of Digital Multi function meter in the existing panel as required
49OD355339/2025-2026:Supply and installation of 100/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT, 100/5 A, 10 VA, accuracy class 10P 5, Protection CT (Tape wound)
50OD355340/2025-2026:Supply and fixing LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour.
51OD355350/2025-2026:Supply and fixing LED indicators for all voltage ranges - Blue Colour.
52OD355327/2025-2026:Supply, installation, testing and commissioning of 2A SP MCB in the existing panel as required.
53OD355331/2025-2026:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipment's including providing suitable size insulated sockets at thetermination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.1.50 sq mm single run with required sockets.
54OD355343/2025-2026:Supply and fixing Aluminium anodized legend plate of size 100 x 40 mm. with inscription of BUS BAR CHAMBER.
55OD355353/2025-2026:Supply and fixing Aluminium anodized legend plate of size 100 x 40 mm. with inscription of CABLE ALLEY.
56OD355334/2025-2026:Supply and fixing legend plate of Aluminium anodized Danger Notice Board of size 150 x 100 mm with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red color in the panel assembly.
57OD355336/2025-2026:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm,4 cm or 5 cm height.
58OD355588/2025-2026:Supply and providing 4.5Kg capacity CO2 type Fire Extinguisher ISI marked conforming to IS: 15683 complete with delivery hose horn, wheel type release valve, locking arrangement, operation manual and bracket with Operating Temperature:- 30ºc to +60ºc including fixing it to wall as required.
59OD355589/2025-2026:Supply and providing 2mm thick electrical grade chequied type rubber mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength in front of panels & Generators.
6090.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
6190.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
6290.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
639.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
649.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
659.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
669.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
67OD355490/2025-2026:Supply and Fixing 125 Fuse base and fuse link in the existing panel board and giving connection including all labour charges.
68OD355491/2025-2026:Supplying and fixing 125 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board.
6990.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
70OD355351/2025-2026:Supply and providing M8 anchor bolt hook in wall / parapet for binding support for service main. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56344762
AUTHORITY Government Departments
TENDER VALUE 2.31 Lakhs
LAST DATE 15-07-2026
Authority
Authority Name Local Self Government Department
Work Description Tender for General-Vadakarapathy Gp - 2025 - 26 - Project No. 166/26 - Setting Of Waste Treatment Plant - Electrification-Electrical Work-General Electrical Work
Basic Detail
Tender No 11/AE/LIDEW/VKPY/2026-27
Bidding Type Tender
Location
City Palakkad
State Kerala
Key Dates
Publish Date 09 Jul 2026
Submission Date 15 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 2.31 Lakhs
Tender Fee 5785
EMD 555
Exemption Available
Document List
628501db-f927-45c5-87f6-31dc6cacb4f5.html
affidavit.pdf
BOQ_1452850.xls
fot.pdf
pagt.pdf
Tendernotice_1 (10).pdf
Tendernotice_2 (6).pdf
Tendernotice_3 (1).pdf
viewsbdcompr.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 15, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Jul 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

628501db-f927-45c5-87f6-31dc6cacb4f5.html

pdf

affidavit.pdf

xls

BOQ_1452850.xls

pdf

fot.pdf

pdf

pagt.pdf

pdf

Tendernotice_1 (10).pdf

pdf

Tendernotice_2 (6).pdf

pdf

Tendernotice_3 (1).pdf

pdf

viewsbdcompr.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders