Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56344754

Tender For General-Annual Maintenance Contract- Mini Civil Station At Vaikom Thalayolapparambu And Kaduthuruthy-For The Year 2026-2027-General Electrical Work

Issued by Government Departments · Kottayam, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Jul 2026
6 days left
EMD
2118
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kottayam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for General-Annual Maintenance Contract- Mini Civil Station At Vaikom Thalayolapparambu And Kaduthuruthy-For The Year 2026-2027-General Electrical Work

BOQ

Name of Work:- GENERAL-Annual Maintenance Contract- Mini Civil Station at Vaikom Thalayolapparambu and Kaduthuruthy-for the year 2026-2027-General Electrical Work
Sl. No. Item Description
1Electrification
21.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
390.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
4OD315809/2025-2026:Supply and providing 20W, 1200mm LED Tube in the existing box type fittings after providing necessary alterations in the wiring of the fittings and make it good working conditions.
590.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
6OD315808/2025-2026:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.<br>300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C-
7OD315812/2025-2026:Supply and providing the following types and power rated lamps in the existing fittings as required 9W LED bulb -
890.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
990.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
101.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
111.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
121.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
131.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
141.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
151.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
161.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
171.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
181.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1990.10.3.24:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )Step Fan regulator - type 2 M
201.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
211.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
221.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
231.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
241.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
251.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
261.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
272.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
282.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole
292.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
302.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
312.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
322.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps
332.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
3490.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
35OD315811/2025-2026:Supply and replacing faulty Ceiling fan capacitor of 2 / 2.25/2.5 mfd 240 V
36OD315813/2025-2026:63 Amps fuse unit with HRC fuses
37OD315814/2025-2026:Supply and fixing 32A HRC fuse base with HRC fuse link-
38OD315810/2025-2026:Supply and fixing of Neutral link32 A, 2 Way neutral links mounted on DMC/SMC base- Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56344754
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 16-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for General-Annual Maintenance Contract- Mini Civil Station At Vaikom Thalayolapparambu And Kaduthuruthy-For The Year 2026-2027-General Electrical Work
Basic Detail
Tender No ESDK_ET_41_2026-2027
Bidding Type Tender
Location
City Kottayam
State Kerala
Key Dates
Publish Date 07 Jul 2026
Submission Date 16 Jul 2026
Open Date 18 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 555
EMD 2118
Exemption Not Available
Document List
794813b5-873e-4ec6-b5b5-f7e09371a411.html
BOQ_1453496.xls
LISTOFMATERIALS.pdf
NIT.pdf
Specificcondition.pdf
Tendernotice_1 (10).pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

794813b5-873e-4ec6-b5b5-f7e09371a411.html

xls

BOQ_1453496.xls

pdf

LISTOFMATERIALS.pdf

pdf

NIT.pdf

pdf

Specificcondition.pdf

pdf

Tendernotice_1 (10).pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders