Tender For Provn Of Lt Panel, Lt Cable, Dbs And Allied Items To Cater For Additional Load In Bldgs No Tp-12, T-13 In Vicinity Of Rvp Under Ge (U) Meerut Cantt.
Tender Value
4.81 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
20 days left
EMD
9700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Meerut → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Lt Panel, Lt Cable, Dbs And Allied Items To Cater For Additional Load In Bldgs No Tp-12, T-13 In Vicinity Of Rvp Under Ge (U) Meerut Cantt.
BOQ
| Sl. No. | Item Description |
| 1 | Supply install testing and commissioning factory made and tested CPRI approved LT panel board, outdoor type of size (900mm x 800mm x500mm), canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 300 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The panels shall be comprising of following : (a) MCCB 4 pole 415 V 200 Amps.35 KA Adjustable type -1 No (Incoming)(b) Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 NoOutgoing:- (a) 4 Pole MCCB 100 Amp, 50 HZ 415 V-01 nos. (b). 4 pole MCCB 63 Amp, 50 HZ 415 V-2 Nos.(c) MCB TPN 63 Amp , 50 HZ 415 V -01 No , including cost of material, labour and T & P as per drawing complete, for proper completion of work all as specified and directed.(d) Platform of panel :- Platform for the panelshall be constructed with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3: 6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes :- (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB 200 Amp 4 pole and one spare MCB chamber in panel to be made for future extension. (iv) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 2 | Supply, laying, jointing, testing and commissioning LT underground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098 (marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. Cables of the following sizes:- |
| 3 | 95 Sqmm 3.5 core |
| 4 | 35 Sqmm 3.5 Core |
| 5 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying cables / poles foundation / stay assembly and getting out in Soft soil complete all as specified and directed . |
| 6 | Removing excavated material not exceding 50 m and depostingwhere directed at a level not exceding 1.5 m above the starting point complete all as specified and directed .. |
| 7 | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified and directed . |
| 8 | M & L for dry sand cushioning trenches for cable cushioning including watering all as specified on both top and bottom of cable including ramming all as specified and directed. Note : Punned thickness shall be considered for measurement purpose. |
| 9 | M&L burnt clay fly ash old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed . |
| 10 | Supply and fixing GI pipe light grade mm dia for protection of LT cable under road or on wall complete all as specified and directed . |
| 11 | 50 mm bore |
| 12 | 80 mm bore |
| 13 | M&L for auguring of hole suitable for passing 80mm to 150mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified and directed .Note: Pipe shall be measured and paid separately under appropriate items and any damage to existing cables of any type shall be made good by the Bidder without any extra cost to department. |
| 14 | Supply & fixing TPN MCB DB Box 4 way 200 Amps capacity, 415 volts, Double door, TPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing complete all as specified and directed . |
| 15 | Supply & fixing MCB DB Box 12 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed. |
| 16 | Supply & fixing MCB DB Box 08 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed. |
| 17 | Supply & fixing Isolator TPN AC, 415 volts of 100 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 18 | Supply & fixing Isolator TPN AC, 415 volts of 63 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 19 | Supply & fixing Isolator SPN AC, 240 volts of 63 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 20 | Supply & fixing Isolator SPN AC, 240 volts of 40 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 21 | M&L for plate earthing for panel complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI Earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of LT equipments etc at the other, earth strip encased in and including 50mm bore GI grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 5 of SSR Pt-I. The scope of work also includes necessary excavation and earthwork. |
| 22 | Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by GI earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion (GI earth wire will be protected by using 25 mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I. including taking out old u/s earthing. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender