Tender For Repair/Maint Internal Electrification And Connected Allied Works In Jsos/Ors Md Accn Under Ge(West)Pathankot
Tender Value
25 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
19 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Internal Electrification And Connected Allied Works In Jsos/Ors Md Accn Under Ge(West)Pathankot
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 2 | M&L for modular point wiring for one light/one fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with and including PVC rigid concealed conduit heavy duty suitable size with all accessories including modular matallic flush box of suitable way with modular cover plate for modular switches and sockets , including green 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed. |
| 3 | All as per Srl item No. 2 here-in-before but modular call bell point complete all as specified and directed. |
| 4 | All as per Srl item No. 2 here-in-before but modular 3 pin 5 Amps socket outlet on the same board with other switch complete all as specified and directed. |
| 5 | All as per Srl item No. 2 here-in-before but modular 3 pin 5 Amps socket outlet on the independent board with other switch complete all as specified and directed. |
| 6 | All as per Srl item No. 2 here-in-before but modular 15/16 Amps socket outlet on the independent board with 2.5 Sqmm copper conductor FRLS-H cable and 2.5 Sqmm PVC insulated unsheathed copper conductor cable FRLS-H (green colour) as earth lead complete all as specified and directed. |
| 7 | M&L for modular point wiring with 4 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with and including PVC rigid concealed conduit heavy duty suitable size with all accessories including modular matallic flush box of suitable way with modular cover plate for modular switches and sockets , including green 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed. |
| 8 | M&L for modular point wiring for one light/one fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable in existing PVC concealed conduit including modular matallic flush box of suitable way with modular cover plate for modular switches and sockets , including green 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly, complete all as specified and directed. |
| 9 | All as per Srl item No. 8 here-in-before but call bell point complete all as specified and directed. |
| 10 | All as per Srl item No. 8 here-in-before but 5 pin 5 Amps socket outlet on the independent board with other switch complete all as specified and directed. |
| 11 | All as per Srl item No. 8 here-in-before but 3 pin 5 Amps socket outlet on the same board with other switch complete all as specified and directed. |
| 12 | All as per Srl item No. 8 here-in-before but modular 15/16 Amps socket outlet on the independent board with 2.5 Sqmm copper conductor FRLS-H cable and 2.5 Sqmm PVC insulated unsheathed copper conductor cable FRLS-H (green colour) as earth lead complete all as specified and directed. |
| 13 | M&L for point wiring in repair for light / fan controlled by one switch with 1.50 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable in existing PVC concealed conduit terminated in new anodise pressed steel sunken box of approved thickness with ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed boxes, including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green). |
| 14 | All as per Srl item No 13 here-in-before but for call Bell point complete all as specified and directed . |
| 15 | All as per Srl item No 13 here-in-befor but for 5 pin 5 amps socket outlet or independent board complete all as specified and directed. |
| 16 | All as per Srl item No 13 here-in-befor but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed. |
| 17 | M & L for point wiring in repair with 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable in existing PVC concealed conduit terminated in new anodised pressed steel sunken box approved thickness with ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed piping ,including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour including taking down of old existing wiring any type and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green). |
| 18 | S & F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed. |
| 19 | S & F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed. |
| 20 | S & F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed. |
| 21 | S & F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. |
| 22 | S&F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed. |
| 23 | S & F switch Bell push, flush type, 5 amp one way complete all as specified and directed by Engr-in-charge. |
| 24 | S&F of Bell Ding Dong, AC 230 Volts single Phase complete all as specified and directed by Engr-in-charge. |
| 25 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 26 | S & F ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed. |
| 27 | S&F Modular switch 1 way 6 A, 1 module complete all as specified and directed. |
| 28 | S&F Modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 29 | S&F Modular Socket 16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 30 | S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 31 | S&F Modular Bell push 6A 1 module , complete all as specified and directed. |
| 32 | S&F Modular Fan regulator 6A 1 module , complete all as specified and directed. |
| 33 | S&F in replacement sleek LED mirror light fitting 2 feet long 1x10 W including inbuilt ind driver complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of suitable size complete all as required at site or directed. |
| 34 | S&F in replacement CFLs with LED Lamp, B22 type ,12 watt,complete all as specified and directed. |
| 35 | S&F in replacement energy saving decorative 20W LED batten light fitting (3 in 1 i.e. cool white, off white and warm white) 6500K, 4000K and 3000K type, light fitting axtruded PVC houshing provided for efficient heat dissipation with polycorbonate diffuser and intregrated electronic driver complete with all accessories prewired without tube and making connections with twisted flexible copper cable of suitable size from ceilling rose/PVC connector to light fittings complete all as spd and directed by Engr -in -charge. |
| 36 | S&F in replacement LED Bulkhead fitting 10 watt all as specified and directed by Engr-in-charge. |
| 37 | S&F in replacement LED decorative wall light fixture made up of polycarbonate globe shape suitable for retrofit B22 base with IP-66 protection including 12 W LED Lamp complete all as specified and directed. |
| 38 | M&L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller MS ventilating fans, Single phase, 230 volts 250 mm sweep complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable suitable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 39 | M&L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing MS ventilating fans Single phase, 230 volts 300 mm or 12” H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable suitable size from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 40 | S&F in replacement of existing unsv sheet metal enclosure with sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps 'C' curve complete all as specified and directed . |
| 41 | S&F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 42 | S&F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 43 | S&F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 6 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 44 | S&F in replacement for MCB SP 240 volts any rating from 6 to 40 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 45 | S&F in replacement for MCB SPN 240 volts any rating from 6 to 40 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 46 | S&F in replacement for MCB SPN 240 volts any rating from 63 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 47 | S&F in replacement sub Main Wiring with PVC insulated unsheathed multistrand FRLS-H flexible copper conductor cable of size 2x6 sqmm and one PVC insulated multistrand unsheathed FRLS-H flexible copper conductor cable of size 6 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed. |
| 48 | All as per srl item No 48 here-in-before but submain wiring with 2 single core 4 sqmm and one 4 sqmm as eathing lead complete all as above but 4.00 Sqmm |
| 49 | S&F in replacement of old unsv sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a) MCCB FOUR POLE 63 AMPS AC 415 VOLTS 16 KA=01 NO as incoming and 12 nos. MCB SP 40 Amps, C series as outgoing. ( (i) MCCB, MCB and DB should be of same make. (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. |
| 50 | S&F in replacement bldg secuirty light fitting energy saving high efficiency LED street light fitting 25 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 25 mm dia bent to shape having length on less than 0.9 mtr fixing with clamp etc and making connections using suitable size copper cable from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage. |
| 51 | M&L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion complete all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted). |
| 52 | S&F in replacement MCCB 4 Pole 63 Amps, thermal magnetic release having, breaking capacity 16 KA, 415 Volt in the existing TPN DB including any addition / alteration to the DB to accommodate the new MCCB and connections complete all as specified and as directed by Engineer-in-Charge. |
| 53 | S&F in replacement 20mm Rigid non-metallic PVC conduit heavy duty exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. |
| 54 | S&F in replacement 25mm Rigid non-metallic PVC conduit heavy duty exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. |
| 55 | S&F in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection one twin core flat cable or circular 10 Sqmm including PVC conduit of suitable size complete all as specified and directed by Engr-in-charge. |
| 56 | Supplying, laying, jointing, commissioning and testing in replacement XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 25 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. |
| 57 | All as per item No 56 above but cable of cross sectional area 16 sq mm 4 core. |
| 58 | All as per item No 56 above but cable of cross sectional area 16 sq mm 2 core. |
| 59 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed. |
| 60 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified |
| 61 | M&L for old size Brick covering with equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid as directed. |
| 62 | Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified. |
| 63 | Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified. |
| 64 | S&F in repair GI tubing light gread 50mm bore for cable protection laid in tranches in road crossing or fixed to wall/pole (rate included accessories such as bend, clamps, nuts bolts and washers required for fitting) complete all as specified. |
| 65 | Supply, jointing and testing in replacement heat shrinkable type out door end terminatin jointing kit, suitable for cable of size upto 25 Sqmm to 50 Sqmm, 3.5/4 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge. |
| 66 | Supply, jointing and testing in replacement heat shrinkable type straight through jointing kit, suitable for cable of size 25 to 50 Sqmm, 3.5/4 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge. |
| 67 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 1,11,118.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender