Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56344438

Tender For Repair/Replacement Of Water Level Indicator, Development Of Borewells And Valve Pits Including Connected Items In The Aor Of Age (U) W/S No-I Under Ge (U) Water Supply Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
42 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
13 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Water Level Indicator, Development Of Borewells And Valve Pits Including Connected Items In The Aor Of Age (U) W/S No-I Under Ge (U) Water Supply Delhi Cantt-10

BOQ

Name of Work:- REPAIR/REPLACEMENT OF WATER LEVEL INDICATOR, DEVELOPMENT OF BOREWELLS AND VALVE PITS INCLUDING CONNECTED ITEMS IN THE AOR OF AGE (U) W/S NO-I UNDER GE (U) WATER SUPPLY DELHI CANTT-10
Sl. No. Item Description
1Disconnecting water pipe line, electric conneciton and taking out submersible pump set of any capacity alongwith column pipe with help of chain pully block using tripad etc any depth as required at site and lowering the submersible pump set after necessary development of bore well etc all as specified and directed at site by the Engr-in- charge
2Drilling not less than 300 mm bore hole by DTH method to any depth below the ground level in any kind of rock/soil upto 100 mtr deep including disposal of surplus soil to a distance not exc 50 mtr away all as specified and directed by Engineer-in-Charge.Note : (i) In case of incountering rock prior to 30 mtr depth from ground level the decission of the Garrison Engineer for reboring shall be final and binding. Specific order in writing shall be issued by Garrison Engineer for reboring and the quantities shall vary accordingly. (ii) cost of transportation of DTH plant is included in the unit rate.
3Supplying, lowering & fixing into bore 200mm dia MS casing pipe as IS-4270-2001, minimum 6.0 mm thick ERW having duly welded both sides socketed ends complete all as specified and directed by Engineer-in-Charge
4Supplying, lowering & fixing into bore 200mm dia MS casing pipe as IS-4270-2001, minimum 6.0 mm thick (Slotted) ERW having duly welded both sides socketed ends complete all as specified and directed by Engineer-in-Charge
5M&L for development of bore well of any capacity and size at the pressure 10 kg/sqcm to 15 kg/sqcm by diesel engine driven air compressor of capacity 620 cfm includiing air pipe and connected items to improve the yield of tube well complete all as specified and directed by engineer in charge.
6M&L for development of bore well of any capacity and size at the pressure 22 kg/sqcm to 25 kg/sqcm by DTH Machine of capacity 1200 CFM including air pipe and connected items to improve the yield of tubewell as specified and directed by Engineer in charge. Note : The rate deemed to include the cost of Transportation of machine and minimum 1 Hrs of running.
7Supplying & fixing well cap suitable for 200 mm bore well dia consisting of two parts complete with welding and machinery work having provison of cut out for passing of column pipe and fabricated from MS sheet 3.15 mm thick complete all as specified & directed by Engr-in-Charge.
8Supply & fixing housing clamp for 200 mm dia bore pipe made out of flat MS 150x12 mm thick (length 80 mm) with 4 Nos 20 mm dia of suitable size of bolt, nuts, washers etc including drilling holes of suitable sizes and painting 2 coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
9Supply & fixing housing clamp for 50 mm dia bore pipe made out of flat MS 100x10 mm thick (length 60 mm) with 4 Nos 20 mm dia of suitable size of bolt, nuts, washers etc including drilling holes of suitable sizes and painting 2 coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
10Supplying and packing pea gravel of size 3.00 mm to 6.00 mm around casing pipe complete all as specified and directed by Engr-in-Charge.
11Material and labour for yield testing of tube well by continuous run with suitable equipment all as per IS-2800 part-II of 1979 including complete testing of water suitable for drinking purpose as per IS-10500 of 1991 from testing Laboratory approved by GE and report shall be submitted to GE. The well shall be tested 24 hours continuous after development of the well to acertain the yield. The air compressure/higher capacity pump required for the development of the well by means of over pumping shall be arranged by the contractor at his own arrangement.
12M&L for replacement of Mild steel nut bolt and washer & Angle stand of any size complete all as specified and directed by Engineer-in-Charge.
13M&L for replacement of rubber packing suitable for 50 mm bore complete all as specified and directed by Engineer-in-Charge.
14M&L for replacement of heavy duty GI nipple 300 mm long and 50 mm bore with flange welded on one ends complete all as specified and directed by Engineer-in-Charge.
15S&F in replacement of submersible cable of size 2.5 Sqmm 3 Core. 1100 Volt complete all as specified and directed by Engineer-in-Charge.
16S&F in replacement of submersible cable of size 4 Sqmm 3 Core. 1100 Volt complete all as specified and directed by Engineer-in-Charge.
17Supply, Installation, lowering, testing and commissioning submersible pumping set having discharge capacity 5 LPS at 100 mtr head complete with submersible motor of suitable 5 HP , 3 Phase 415 volt required submersible for 6 inch casing pipe complete all as specified and as directed by Engr-in-Charge
18Supply only GI column pipe, heavy grade, class 'C', 50 mm bore of 3 metre length, heavy duty, flange welded on both ends complete all as specified and as directed .
19Supply Only GI column pipe, heavy grade, class 'C', 80 mm bore of 3 metre length, heavy duty, flange welded on both ends complete all as specified and as directed .
20Supplying, fixing, including jointing and testing of 80mm Cast iron Non Return valve without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 of sizes including taking out unserviceable NRV complete all as specified and as directed at site by the Engineer-in-Charge. (Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of item)
21Supply, fixing, jointing and testing 80mm bore cast iron Sluice Valve, ISI Marked, flanged ends drilled pressure rating PN-1.0, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel complete all as specified and as directed at site by the Engineer-in-Charge. (Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of item.)
22Supply, fixing, jointing and testing 100mm bore cast iron Sluice Valve, ISI Marked, flanged ends drilled pressure rating PN-1.0, Confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel complete all as specified and as directed at site by the Engineer-in-Charge. (Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of item.)
23Supply and installation of flanged ends strainer/dirt box of sizes 80mm with stainless steel mesh suitable for water meter for potable water supplies on up stream of water meter to avoid foreign material entering into meter complete all as specified and as directed at site by the Engineer-in-Charge.
24Supply and installation of flanged ends Water Meter woltman type,of size 80mm including testing and making good connection with flanged ends, with gasket rubber sheet and nut & bolts etc ISI Marked fixing in horizontal/incline/vertical position, complete all as specified and as directed at site by the Engineer-in-Charge.
25Supply,laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 3.5 core.including connection complete all as specified directed by the Engineer-in-Charge
26Supplying and laying XLPE insulated, armoured heavu duty electric cable with aluminium conductor 1100 Volts grade cross sectional area 35 Sqmm 4 Core laid in trenches/floor/wall incl taking out old unserviceable cable and connection to panel for incoming and outgoing using suitable aluminium lugs complete all as specified and directed.
27Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified ans as directed.
28Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified ans as directed.
29Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed.
30M&L for spread fine river sand in trenches complete all as specified ans as directed. (NOTE: For measurement purpose, punned down thickness shall only be taken.)
31M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
32Material and labour for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, flooring sub base complete all as specified and as directed at site by the Engineer-in-Charge.
33Material and labour rendering 10 mm thick with cement plaster (1:6) on fair faces of brick walls for finishing the surface even and fair complete all as specified and directed by Engr in charge
34Supply and Fixing in replacement of MS foundation bolts with nuts and washers, size 20mm dia , 450 mm long complete all as specified and as directed.(including breaking of hard standing foundation)
35Supply,Laying, jointing, Testing and commisioning of MS Pipe of following size, as per IS:1239 with and including MS flange, 16 mm thick welded for drilling of 16 mm dia bolts, nuts, washers, rubber gaskets etc laid in trenches complete all as specified and as directed.
3680 mm
37100 mm
38Taking up DI/GI/Nidhi/CI/MS /Cemented Pipes including all fitting of the following sizes as specified and directed by Engineer-in-Charge :-
3980 mm bore
40100 mm bore
41150 mm bore
42Supply, laying jointing,testing DI pipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work & rubber gasket (Tyton) joints with jointing material & route indicators of the following sizes including taking down of existing CI/DI pipe complete all as specified and directed by Engineer-in-Charge. (Note : (i) Excavation & earth work shall be measured & paid separetely under respective items of BOQ.(ii) Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates.(iii) DI pipe whole quantity of tender shall be procured by contractor in one time from the authorised dealer of approved make and PV's, MTC & e-way bill will produced by contractor during payment of 1s RAR as material laying at site.(iv) Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the DI pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly.(v) Layout plan for laying of DI pipe shall be given by EIC in writing.
4380 mm bore
44100 mm bore
45150 mm bore
46Material and labour for DI specials like MJ Collars, Bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore.
47Material and labour for Cast iron bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (both all sockets or socket and spigot or flanged) collars, cast Iron connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up 200 to 300 mm dia bore.
48Material and labour for Rubber Gasket Joint (Tyton Joint) including jointing material for DI/CI pipe of following size/bore :-
4980 mm bore
50100 mm bore
51150 mm bore
52Taking down water level indicator unit from Over head reservoir/Semi Under ground sump, supply and fix new water level indicator with complete accessories such as copper ball, necessary pully, nylon rope, steel Plate duly painted white with marking at every 10cm interval, letter writing of size 15mm width and 100mm long with signal red radium paint and painting of indicator with illumination postal red paint and errected at the height of 3 meter from ground level with necessary angle, nut and bolts rightly calibrated as per the tank level complete all as specified and directed by Engr-in-charge.
53Supply & fixing , install testing and commissioning of LT panel ,outdoor type cubical shape,three phase, 4 wire, Aluminium bus bar for phases and neutral made out of CRCA sheet 3.0 mm thick sheet ,factory fabricated, CPRI approved, dust and vermin proof, sloopy roof, opening at bottom for cable in/ Out, provn for ventilation, angle iron frame and four legs of 50x50x6mm thick angle iron, 2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level, grouting properly, and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar, switch gear all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs, spreader terminals etc.(a) Aluminium bus bar with PVC sleeve suitable for 600 amps for Phase & 300 Amp for Neutral - 01Set.(b) Voltmeter, digital type 0- 500 Volt,with selector switch - 01 set Make: DIP/AE/IMP/NSD(c) Ammeter Digital type 0-200 Amps, with selector switch and CT - 07 set Make: DIP/AE/IMP/NSD(d) Phase indicating lamps LED type ( red , yellow, blue) 01 set(e) Incoming MCCB 63 Amp 4 pole 16 KA - 01 No (f) Outgoing MCCB 40 Amp 3 pole 16 KA -02 Nos (g) FASD Starter ML-1.5 with MS sheet enclosure -01 Nos (h) Outgoing MCB SPN 20 Amp, 230 Volts 10 KA -01 No
54An amount of Rs 1,08,300.00 shall be deducted from BOQ on account of schedule of credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56344438
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Water Level Indicator, Development Of Borewells And Valve Pits Including Connected Items In The Aor Of Age (U) W/S No-I Under Ge (U) Water Supply Delhi Cantt-10
Basic Detail
Tender No GE/WS/Token No-15 OF 2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 07 Jul 2026
Submission Date 28 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 42 Lakhs
Tender Fee 500
EMD 84000
Exemption Available
Document List
184deac5-2037-4b43-b05f-26020c9a1bfc.html
BOQ_870061.xls
tender.pdf
Tendernotice_1 (3).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

184deac5-2037-4b43-b05f-26020c9a1bfc.html

xls

BOQ_870061.xls

pdf

tender.pdf

pdf

Tendernotice_1 (3).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender