Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56344437

Tender For Repair/ Maintenance Of Damaged, Chajjas, Facia, Utility Shafts, Painting Of External Surfaces, Damaged Joineries, Cupboards And Cabinet, Plinth Protection, Saucer Drains At Various Loc Of Khojatoli And Repair Of Earthing Of Distribution Bo

Issued by Statutory Bodies & Commissions/Committees · Ranchi, Jharkhand
Tender Value
36 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
19 days left
EMD
72000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Damaged, Chajjas, Facia, Utility Shafts, Painting Of External Surfaces, Damaged Joineries, Cupboards And Cabinet, Plinth Protection, Saucer Drains At Various Loc Of Khojatoli And Repair Of Earthing Of Distribution Boxes, Ceiling Fan, Wall Mounted Fan At Namkum And Khojatoli Under Ge Ranchi

BOQ

Name of Work:- REPAIR/ MAINT OF DAMAGED, CHAJJAS, FACIA, UTILITY SHAFTS, PAINTING OF EXTERNAL SURFACES, DAMAGED JOINERIES, CUPBOARDS AND CABINET, PLINTH PROTECTION, SAUCER DRAINS AT VARIOUS LOC OF KHOJATOLI AND REPAIR OF EARTHING OF DISTRIBUTION BOXES, CEILING FAN, WALL MOUNTED FAN AT NAMKUM AND KHOJATOLI UNDER GE RANCHI
Sl. No. Item Description
1Taking down chowkat or frame n.exc 1.5 sqm each with shutters (without taking off shutters from the frames).
2Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete.
3M&L brick work with sub class 'B' brick straight or curved on plan exc 6m means radius build in cement mortar 1:6 all as specified and directed.
4Description all as per above ser item No 03 above but except brick.
5M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in ceemnt mortor 1:4 all as specified and directed.
6Solid PVC door frame of size 50 X 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, supplied and fixed in repair in opening as per specifications and drawing complete as directed.
7Factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail, MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail; Panelling of plain colur PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, Supplied and Fixed in the frame at site as per specification and drawings complete all as specified and directed.
8Taking down cement plaster on wall of any description incl racking out joints hacking for key and scrubbing down with water complete.
9M/L rendering 15mm thick (10mm + 5mm)in CM 1:4 in two coats on fair faces of brick work , finished even and fair without using extra cement with WPC all as specified and directed.
10Demolition of RCC any thickness and any size as in columns, roof slab, chajja, facia and beam etc complete all as specified and as directed.
11M&L Providing precast.cement concrete louvres and jallies 1:2:4 type B-0 (12.5mm graded stone aggregate) set in cement mortor 1:4 , 25mm thick (measured solid), including all mouldings but excluding frame all as specified and directed.
12S/F in repair 4.80mm thick sheet glass ordinary quality and glazing with oil putty in square nexc 0.5 sqm in each pane
13S&F in repair Galvanised mild steel wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks etc complete all as specified.
14M & L for complete removal of existing surface and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete a directed.
15M & L Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete a directed.
16Demoliton of cement concrete in ground floor paving n exc 15cm thickness ( below or above ground level ) complete.
17M & L for 75 mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate including finished surface even & fair without using extra cement as in plinth protection including necessary form work of edge all as specified and directed. Note: 10mm wide and 75mm deep joints shall be made at 3 mtr intervel and at each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio 1:3. all as specified and directed.
18Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe -290 Gde E-165
19M & L cement concrete type C - 1 (1:3:6) using 20 mm graded stone aggregate as in bed blocks,fillings for holdfast etc complete.
20S & F Aluminium anodised handles of extruded section and fixed 125 mm long.
21S & F 100 mm size Butt hinges medium weight cold rolled mild steel and fixed.
22S & F 250 mm long mild steel sliding door bolt with hasp, staple( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections and fixed.
23Taking down eaves gutter and rain water pipes (any size or pattern ) including all fittings, heads shoes bend swan necks etc at any position ( measure overall as fixed along the centre line over fitting and accessories ) all as specified and directed.
24S& F PVC (SWR) pipe of 110mm dia single socketed in any length with rubber ring joints fixed to floors all as specified.
25S& F PVC (SWR) pipe of 110mm dia single socketed in any length with rubber ring joints fixed to walls all as specified.
26S&F PVC (SWR) bends or shoe of 110 mm dia bore
27PVC (SWR) junction single, (Single T) 110 mm dia bore equal or unequal
28M&L 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors fixed in repair all as specified and directed.
29M&L 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, inwall surface fixed in repair all as specified and directed.
30M&L 75mm bore PVC (SWR) bends any radius fixed in floor in repair
31M&L 75mm bore PVC (SWR) junction single, (Single T) equal or unequal fixed in repair
32M & L for repairing broken edges of chajja's, roof projection, Fascias etc . In small widths/depths ( exposed area not exc 0.16 Sqm ) by breaking the cracked/loose portion and filling with Cement Mortar / Plain Cement Concrete 1:2:4 ,Type B-0 , using 12.5 mm Crushed stone aggregates , to match the exisitng surfaces incl removing debris , necessary scaffolding , etc all as specified and directed. (Note : Reinforcement if any provided shall be measured and paid separately)
33M&L for expanded metal n.exc 4Kg per square metre, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members all as specified and directed.
34M & L for taking down and repairs in patches (area n.exc 2.00Sq min each patches) to plaster/loose surfaces of concrete slabs in sun-shades, chajjas, fascia,shelves, cills, landingsin cement mortar 1:4 /cement concrete 1:2:4 including all necessary arrangments for complete repairs all as specified and directed.(Note : Reinforcement/expanded metal if any provided shall be measured and paid separately)
35M&L mild steel TMT bars 6 to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed
36M&L 15mm thick rendering on fair faces of bk /concrete surfaces in cm (1:4), finished even and smooth (Without using extra cement ) including scafolding up to G+3 story bldg, etc complete.complete
37M&L three coat of white wash on Newly Plaster prepared surfaces on wall , etc complete.
38M&L three coat of Cement base paint on Newly Plaster prepared surfaces on wall including scafolding up to G+3 story bldg, etc complete.
39M & L for preparing old plastered surfaces of wall and applying two coat of white wash on walls
40M & L for preparing old plastered surfaces of ceilings and applying one coat of white wash on ceilings complete all as directed
41M & L for preparing old plastered surfaces of wall and applying two coat of Cement base paint on walls including scafolding up to G+3 story bldg, etc complete.
42M&L Complete removal of existing treatment,Preparing surfaces plastered or unplastered old surface but applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces.
43M&L wall care putty 2mm thick including necessay preparation or already prepared surface complete all as specified and directed.
44M&L for preparation of old wooden surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint white or tinted complete all as directed.
45M&L for preparation of old wooden surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint white or tinted complete all as directed.
46M&L for preparation of old painted steel surface of any description , over 10 cm width or girth not otherwise described and applying one coat of synthitic enamel paint white or tinted all as directed.
47M&L for preparation of old painted steel surface of any description , over 10 cm width or girth not otherwise described and applying one coat of synthitic enamel paint white or tinted all as directed.
48Taking down chowkat or frame exc 1.5 sqm but n.exc 4 sqm with shutters (without taking taking off shutters from the frame).
49Taking down shutters of any description not exc 1 sqm each
50Taking down shutters of any description exc 1 sqm but n exc 2 sq. m each
51M&L Plain, solid, straight chowkats and frames 2nd class hard wood, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, and fixed all as specified and direcetd.
52M&L pressed steel frames for door of size 105x60 mm for door with one or more rebates incl necessary fittings, lugs, hinges, lock strike plate, flat iron hold fast etc complete as specified & as directed.
53M&L pressed steel frames for door of size 125x60 mm for door with one or more rebates incl necessary fittings, lugs, hinges, lock strike plate, flat iron hold fast etc complete as specified & as directed.
54M&L PCC 1:3:6 type C1 using 20m graded agg as in bed block or for embeding of holdfast as specified and directed.
55S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specififed and directed.
56S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specififed and directed.
57S&F 35 mm thick Flush shutters, solid core, construction, with block board core and plywood face panels, commercial type on both sides with particle board core all as specified and as directed.
58S&F for 35 mm thick 2nd Class H/Wood gauged and skeleton shutters, open rebated and prepared to receive gauge etc (with sash bars), edges of raming plain, chamfered or grounded, fitted with cut of and mitred beads for securing gauge etc of size of members of shutters as specified in SSR Part-I section 8 clause No. 8.2(a) and fitted to chowkats complete all as specified and as directed.
59M&L for preparation of new wooden surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer.
60S & F mild steel butt hinges 100mm size medium weight, cold rolled complete all as specified and directed.
61S&F 150mm long aluminium anodised tower bolts
62S&F 150mm size aluminium anodised door handles
63S&F 300mm long alluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or xtruded section and fixing bolts and sliding of extruded section.
64S&F in repair galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire stapple
65S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire stapple
66Hacking out old broken glass (any thickness), size quality or description from metal frames incl punching or drilling out glazing pins/springs clips and providing and fixing new ones glazed with putty or fixed with beads complete all as specified and directed .
67Supply & fix 3mm thick sheet glass, ordinary quality glazing with oil putty or fixed with wooden beads or in steel windows in square n.exc. 0.50sqm each pane
68Supply & fix 3 mm thick sheet glass, frosted type ordinary quality glazing with oil putty or fixed with wooden beads or in steel windows in square n.exc. 0.50sqm each pane
69S&F for 300 mm, mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete.
70S&F in repair harrison rails, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc.
71M&L for Rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finished even & smooth without using extra cement.
72M&L for two coats of Distemper on walls over New plastered surfaces of wall incl preparation of surfaces complete all as specified and as directed.
73Supply & Fixing 18-19mmm Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed.
74M&L for 18/19mm thick extra over rates of block board or veneered particle board for external teak wood lipping, 6mm thick fixed with nails all as specified and directed.
75M&L 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with aluminium frame.
76S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanisedwidth of flap 40mm all as specified and directed.
77S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanisedwidth of flap 75mm all as specified and directed.
78S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel with brash polished finished all as specified and directed.
79S&F Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws size of hasp and staples 100mm all as specified and directed.
80M&L Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.including (Minnimum thickness of powder coating 50 Micron) complete all as specified.
81M&L powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc.including (powder coating not less than 50 micron) complete all as specified.
82M&L Powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.)(Minnimum thickness of powder coating 50 Micron) complete all as specified and directed
83M&L Powder coating aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc .including (powder coating not less than 50 micron) complete all as specified.. complete all as specified.
84S&F 4 lever brass mortice lock vertical type size 65mm long complete.
85S&F anodised aluminium Grill (anodised transparent or dyed to required shade according to IS:1868 with minimum adodic coating of grade AC 15) of approved design /pattern with approved standard section and fixed to the existing window frame with C.P.brass /stainless steel screw @ 200mm center to centre ,including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening,all complete as per requirment and direction of engineer in charge all as specified and directed
86Taking down aluminium doors shutters only (area exc 1.0 sqm but not exc 2.0 sqm each) and dismantling all members and reassembling the same with and including new screws, new rubber gasket, new aluminium beads & cleats of existing make and also refixing the handles & mortice locks in existing position with and including new screws including refixing the door shutters in same opening complete all as specified & directed.
87Supply & fix 5.5mm thick sheet glass, ordinary quality glazing with oil putty or fixed in steel windows in square n.exc. 0.50sqm each pane
88S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed.
89S&F in repair door closer hydraulically regulated, designation No-3 universal type, aluminium (extruded section body), suitable for door shutter of 851 to 1000mm in width and weight between 61 to 80 Kg and fixed complete all as specified and directed.
90S&F in repair 5-6mm thick insulated PVC coloured Wall panelling including lining and necessary ceats, Screws etc for fixing to wall complete all as specified and as directed.
91Preparing surfaces of wood and wood based materials, new or old, of any description and girth not otherwise described and treated with creosote oil.
92M&L for two coat of synthetic enamel painting to steel surfaces any descrtiption over 10 Cm in width or girth not otherwise described incl preparation of surfaces including roof surfaces.
93M & L for PCC 1:2:4 type B1 using 20 mm graded aggregate as in copping and the like including weathering, slightly rounded or chamfered angles and throating, as directed
94Material & labour for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base, drain floor complete all as specified and directed.
95Material & labour for cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as insurface channel and Drains complete all as specified and directed.
96M&L cement concrete 1:4:8 type D-2 using 40mm graded aggregate in foundation, filling and mass concrete complete.
97M&L Providing precast cement concrete Type B1 1:2:4 (20mm graded aggregate) set in CM 1:6 in Slab Covers, lintels,bressumers, steps, quoin blocks (for use with masonry), copings, kneelers, apex stones,, columns, posts, with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match.
98Demoliton of cement concrete in ground floor paving exc 15cm thickness ( below or above ground level ) complete.
99Hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and well rammed to a true surface.complete including all as specified & as directed.
100M&L for 100 mm thick cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base complete including all as specified & as directed.
10175mm thick, PCC 1:3:6, type C-1 using 20 mm graded stone aggregate, as in plinth protection finished even & smooth without using extra cement complete all as specified and directed .
102M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in 'D' shape 500 mm legth grouted in wall complete all as specified and directed.
103M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised Iron Strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in 'D' shape 500 mm legth grouted in wall complete all as specified and directed.
104Supply and erection of Earth electrode 17.2 mm dia 3 mtr long of low carbon steel electrode with copper bonding of thickness 250 micron, Back-fill earthing enhancing compound AXIS ULTRA / AXIFILL type Carbon based compound conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction. Back-fill comound should be environment friendly & should be solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Test Certificate as per as per IEC: 62561-7 for Back-fill compound shall be submitted along with the material including SS clamp to be provode both side and PVC EARTH PIT 300 X 300 MM WITH PLASTIC LID complete all as specified Note - (i) Earth electrode should be applicable Standards IS: 3043, IEC 62561-2 & IEC 60364-5 and made of High Tensile steel rods copper bounded, High tensile strength,good electrical conduction & effective performance and suitable for all type of soil and provided minimum distance 3 Mtrs. (ii) Back-fill compound should be Compliance to the Standards IEEE: 80, IS-3043, BS 7430, IEC 62561-7, ANSI/NSF 60 Certification.(iii) Positive low resistance electrical connection to the earth. (iv) Does not contain hazardous chemicals.(v) Electronically conductive (like in metals) and is not dependent on moisture.(v) Provide the desire value of earth resistance as per required specified values. (vi) Provide the Exothermic welding joints to entire grid system joints of earthing electrod. MAKE : OBO BETTERMANN/ AXIS/ VTR
105S&F in renewal Earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised steel wire complete all as specified and directed.
106S&F in renewal Earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25x 4 mm dia galvanised iron Strip complete all as specified and directed.
107S&F air termination single pointed Aluminium rod 12 mm dia, 300 mm long for lightening conductor including takingdown old one complete all as specified and directed.
108S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex. Head screw for fixing in wall complete all as specified and directed.
109Supply of Back-fill earthing enhancing compound type Carbon based compound conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard and filling around the electrode inside the bore hole. Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction. Back-fill comound should be environment friendly & should be solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole complete all as specified and directed.
110Carrying out Periodical testing of earth continuity and measurement of earth resistance value of individual earthing by approved digital eatrh resistance tester including opening and refixing of earth pit covers, cleaning and tightning of all earth connections, watering whenever required, recording of readings and submission of test reports complete all as specified and directed.
111M&L lightening conductor assembly made out of GI pipe medium grade of size 40 mm bore along with welded flange, fixed on the RCC roof of the bldgs with drilling/making hole and provide fastners, rubber washer, to connect air termination & connector for earth strip duly fixed with necessary fastners, nuts bolts & washers in PCC 1:2:4 type B0 45cm x 45cm x45cm complete all as specified and directed. Please Enable Macros to View BoQ information
112M&L lightening conductor assembly made out of GI pipe medium grade of size 40 mm bore along with welded flange, fixed on the RCC roof of the bldgs with drilling/making hole and provide fastners, rubber washer, to connect air termination & connector for earth strip duly fixed with necessary fastners, nuts bolts & washers in PCC 1:2:4 type B0 45cm x 45cm x45cm complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56344437
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Damaged, Chajjas, Facia, Utility Shafts, Painting Of External Surfaces, Damaged Joineries, Cupboards And Cabinet, Plinth Protection, Saucer Drains At Various Loc Of Khojatoli And Repair Of Earthing Of Distribution Boxes, Ceiling Fan, Wall Mounted Fan At Namkum And Khojatoli Under Ge Ranchi
Basic Detail
Tender No 8200/1723/E8
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 07 Jul 2026
Submission Date 28 Jul 2026
Open Date 04 Aug 2026
Finance
Tender Value 36 Lakhs
Tender Fee 500
EMD 72000
Exemption Available
Document List
362b6a7e-4dea-463b-8b4c-8f70b13b3f14.html
BOQ_869966.xls
Tender1723.pdf
Tendernotice_1 (3).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Aug 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

362b6a7e-4dea-463b-8b4c-8f70b13b3f14.html

xls

BOQ_869966.xls

pdf

Tender1723.pdf

pdf

Tendernotice_1 (3).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail