Tender for Repair Maintenance Of Security Light, Control Panel, Cable High Mast Distribution System For Security Light, Garden Light, Earthing, Lightning Arrester, Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Meter, Internal Wiring Fitting, Summer/ Cooling Appliances With Plant And Other Allied Works At Site P And Site R At Af Station Thane Under Ge(Af) Thane
BOQ
| Sl. No. | Item Description |
| 1 | Supply and providing Eletrician with helper for repair the unserviceale street light/ aviation light including taking down High Mast Light and taking up High Mast machanically/ Post Lamp fittings/ Garden Light, Gate light and reflixing the same in existing postion including testing after repair complete all as specified and directed by Engineer-in-Charge,Note: (a) Necessary spare, fitting, excavation other related work will be measured in respective items.(b) Necessary tools, ladder, safty equipment for electrifican and helper will be arrange by the contractor in his own coast |
| 2 | Supply only Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 30 watt, complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply only Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 45/60 watt, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Supply only Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 120 watt, complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply only Surge Protection Device of capacity 10KV Single Phase 50Hz, complete all as specified and directed by Engineer-in-Charge. |
| 6 | S&F Multi LED Street Light fitting of capacity 30 Watt IP 65, having Die-cast Aluminium Housing, weather proof with Accessories and connecting up with and including PVC insulated Copper Conductor cable 1.5 Sqmm, single core including Taking down unserviceable Street light fitting from the Electric pole, complete all as specified and directed by Engineer-in-Charge.. |
| 7 | S&F Multi LED Street Light fitting of capacity 45 Watt IP 65, having Die-cast Aluminium Housing, weather proof with Accessories and connecting up with and including PVC insulated Copper Conductor cable 1.5 Sqmm, single core including Taking down unserviceable Street light fitting from the Electric pole, complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L Inegaral Decorative LED 8 Watt Bollard Energy saving, Environmental friendly aesthetically designed with opal acrlylic with IP-65 proctection, providing electric connection with suitable PVC copper flexible conductor, providing PCC 1:3:6 (20mm graded aggregate) work of size 300x300x450mm including necessary formwork and earth work, complete all as specified and directed by Engineer-in-Charge. Cat part No. LHEVBDP7IN6K008 |
| 9 | Supply & fixing in replacement Integral LED aviation light 30 watt comprising of aluminium housing with polycarbonate enclosure with IP-65 protection complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply, fixing and testing LED Flood light fitting of 120 Watt in repair/replacement of existing high mast lights including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply only LED Bulb 15 watt for Integral pole mounted decorative LED post top with spherical/GLOBE shaped, 240 V 50Hz complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply, fixing and testing Post top lantern of 25/45 Watt in repair/replacement of existing lights including LED lamps, acrylic, canopy totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report including suitable size of GI pipe for post with PCC 1:3:6 complete all as specified and directed by Engineer-in-Charge. |
| 13 | All as per Item No 12 above but Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp base 20 Watt complete all as specified & directed by Engr-in-Charge. Make - Havells Cat part No LHFXBON1TN5Q020 , Bajaj BLPTSP 25W NW LED or equivalent. |
| 14 | Relaying XLPE Under Ground Cable of any description (Serviceable Cable obtained from Item No.02 here-in-before) 1100 Volt grade, cross sectional area 35 Sqmm to 50 Sqmm, 3½/4 Core after Fault rectification including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply & Laying/Fixing XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 10 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply & Laying/Fixing XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 16 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply & Laying/Fixing XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 25 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply & Laying/Fixing XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 35 Sqmm 3.5 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply and fixing HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 280 x 200 with 32 Amp 4 way heavy duty terminal block with 10Amp MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole, including taking down existing ,complete all as specified and directed by Engineer-in-Charge. |
| 20 | M&L for for applying two coat of Cement based paint on PCC poles of street lights of ant description up to including 9 m overall length including preperation of old painted surface of PCC Poles complete all as specified and directed by Engineer-in-Charge.Note :- Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces. |
| 21 | M&L for for applying two coat of Silver paint on GI poles of street lights of ant description up to including 9 m overall length including preperation of old painted surface of G I Poles complete all as specified and directed by Engineer-in-Charge.Note :- Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces. |
| 22 | M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) as in Copping of Electric Poles, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork including dismantling PCC Copping and/or removing damaged PCC Copping, complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L GI Pipe Bracket made out of Galvanised Iron Tubing 32/40mm bore (dia), light grade, 1.50 METRE long bent to shape as per specified for fixing Street Light Fitting including applying Two coats of Aluminium Paint over a coat of Aluminium Primer including taking down old unserviceable GI Pipe Bracket,complete all as specified and directed by Engineer-in-Charge. |
| 24 | S&F PVC insulated Multi Stranded FRLS-H Copper Conductor Cable 1.5 Sqmm, Single Core for connection of Street Light Fitting including Taking down unserviceable Cable of any description, complete all as specified and directed by Engineer-in-Charge. |
| 25 | S&F PVC insulated Multi Stranded Copper Conductor Cable 1.5 Sqmm 3 Core, Round Flexible for connection of Street Light Fitting including Taking down unserviceable Cable of any description, complete all as specified and directed by Engineer-in-Charge. |
| 26 | Making Hole under Road/ Hardstanding including cutting, etc. with manual anger or bookie not exc. 100mm dia, complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&F in replacement of pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coat of Silver paint over a coat of primer in alternate strip of 30cm each in white and blue colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.Note : PCC for foundation and earth work shall be measured and paid for separately. |
| 28 | S&F in replacement of heavy duty GI pole for Solar street light, 6 meter long 8 erecting truly in vertical position including painting of poles with two coat of Silver paint over a coat complete all as specified and directed by Engineer-in-Charge.Note : PCC for foundation and earth work shall be measured and paid for separately. |
| 29 | M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge. |
| 30 | M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, struts & mass concrete including necessary form work and fair finishing to exposed surfaces complete all as specified and directed by Engineer-in-charge |
| 31 | M&L Galvanised Steel Tubing Pipe 50 mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and directed by Engineer-in-Charge. |
| 32 | M&L for hardcore of broken stone boulder, gauge not exc. 63 mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge |
| 33 | Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and directed by Engineer-in-Charge. |
| 34 | Excavation in Trenches not exc. 1.50 Metre wide and not exc. 3 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and directed by Engineer-in-Charge. |
| 35 | Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. seggrating Serviceable Cables, Pipes, Bricks, etc. incuding Serviceable Pipes, Bricks, etc. and keep in Safe Custody for re-use including removing Unserviceable Cables to MES Store Yard and depositing/stacking properly, complete all as specified and directed by Engineer-in-Charge.NOTE : Necessary Earth Work will be measured and paid under appropriate Items. |
| 36 | SM&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and directed by Engineer-in-Charge.NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured. |
| 37 | Taking up reinforced precast concrete cable cover obtained in ser No.37 any class any type with any size complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and laying un reinforced precast concrete cable cover class LV type-II, flat size 250mmx150mmx 40mm laid in trenches complete all as specified and directed by Engr-in-charge. |
| 39 | Relaying of reinforced precast concrete cable cover class LV type-II, flat size 250mmx150mmx 40mm laid in trenches complete all as specified and directed by Engr-in-charge. |
| 40 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and directed by Engineer-in-Charge. |
| 41 | Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 42 | Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and directed by Engineer-in-Charge.NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and Specifications. |
| 43 | S&F of Specification Board (Acrylic) size of 914x610x8mm and fornt size of letter not less than 72 and words which is pasted on acrylic sheet not exceeding 100 nos with suitable hanging arrangent on wall complete as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 44 | S&F of Specification Board (Acrylic) size of 914x610x8mm and fornt size of letter not less than 72 and words which is pasted on acrylic sheet not exceeding 100 nos with suitable hanging arrangent on wall complete as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender