Tender For Supply, Installation, Testing And Commissioning Of Led Flood Lights In Front Of Satluj Hostel At Main C Us Of Iit Ropar
Tender Value
6.99 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
20 days left
EMD
13984
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rupnagar → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing And Commissioning Of Led Flood Lights In Front Of Satluj Hostel At Main C Us Of Iit Ropar
BOQ
| Sl. No. | Item Description |
| 1 | Supplying of XLPE insulated PVC sheathed aluminium conductor armoured cable working voltage 1100 volts grade as per IS 7098 |
| 2 | 4 x 16 sqmm |
| 3 | 3.5 x 50 sqmm |
| 4 | Supply of LT weather proof dust and vermin proof, outdoor feeder pillar (with Double Door), fabricated out of suitable sized angle iron and flats and covered with 3mm thick CRCA sheet steel including canopy with Base Channel of 50 mm in black shade, duly powder coating both sides (front and rear) openable with locking arrangement, rubber gasket cable glands, lifting hooks,Locks & Hinged Door Cable Entry from bottom, three phase LED indicator for each incoming & outgoing etc. The feeder pillars shall be complete with 3 phase and neutral bus bars of 200 amp capacities as described below and Moulded Case Circuit Breakers (MCCBs), copper FRLS control wiring with 1.5 sq.mm, complete in all respects as per specifications as required. |
| 5 | Incomer Feeder -01 Nos, 125A 4P MCCB (36 ka) with thermal magnetic release & rotary handle - 1 Nos, Digital VAF Meter -01 Nos, R,Y,B indication Lamps-01 Set, 150/5 CL 0.15 A CT -04 Nos, Control MCB 6 amp 10 KA \\"C Curve\\"=04 Nos, Outgoing Feeder, 63 A 4P MCCB (25 ka) with thermal magneticrelease & rotary handle - 1 Nos, 63/32 amp MCB - 10 Nos, 63 amp TP MCB 10 KA-06 Nos, 63 amp DP MCB 10 KA-06 Nos, 200 amp TPN Aluminium Busbar, 200 amp TPN Aluminium Busbar and Horizontal and vertical busbar as per load with color coded Heat Shrinkable PVC Sleeves, R,Y,B Phase : 1 x 20 mm x 10 mm, Neutral Bus : 1 x 20 mm x 06 mm |
| 6 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 7 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 8 | Supplying and making indoor termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 9 | 4 X 16 sq. mm (28mm) |
| 10 | 3½ X 50 sq. mm (35mm) |
| 11 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 12 | Above 8.0 Meter and upto 10.0 Meter |
| 13 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. |
| 14 | 32 mm dia |
| 15 | Supply of 80 mm dia 10 Mtr Long GI Pole having 300mm x 300 mm x 6 mm thick M.S Plate and duly plugged top cement concrete 1:3:6(1 cement :3 Coarse Sand : 6 Graded Stone aggregate 40 mm nominal size) foundation with cement concrete collar of size 0.40 mtr dia x0.5 mtr height to accommodate the looping type cable end box with Fixing an angle iron with suitable dimension on top for mounting 6 Nos Flood Lights luminaries with Painting (2 coats) along with excavation work required for fixing the poles. The Poles fixing should be Complete all respects with earthing Studs. |
| 16 | LED Flood Light, powder coated pressure diecast aluminium (System lumen efficacy >135lm/Watt)Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to50 0C, internal surge protection of 5 KV L,N,E as perIEC 61000-4-5, Driver efficiency >85%,THD < 10%as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beamangle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time(LED, Driver & electrical circuitry) of minimum50000 Burning Hours with 70% of initial Lumenmaintained till life ends as per LM80extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 yearOEM warranty. System lumen efficacy >135lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 17 | 250 watt |
| 18 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 19 | Triple pole and neutral |
| 20 | Single Pole |
| 21 | Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required. |
| 22 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring,washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & springwasher spaced at 50mm) |
| 23 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 24 | Supplying, Fixing,Connecting and Commissioning looping type cable end control box with MS Sheet of 16 SWG of Size 200mm x 200mmx 125 mm having 2 nos brass neutral link 12.5 square mm 6 way approx 60 mm long and fixed on 5mm bakelite sheet box duly painted with earthing Stud etc Complete as required |
| 25 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 26 | 3 core 4 sqmm insulated pvc wire Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysJul 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender