Tender For Repair And Maintenance Of All Community Sanitary Complexes Under Gram Panchayat, Shivapuram.
Tender Value
11.19 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
3 days left
EMD
22394
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
North and Middle Andaman → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of All Community Sanitary Complexes Under Gram Panchayat, Shivapuram.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | 1:4:8 (1 Cement : 4 Pulverised sand (zone-III) derived from natura sources : 8 graded stone aggregate 40 mm nominal size derived from natura sources) |
| 6 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 8 | 1:1.5:3 (1 cement : 1.5 Pulverised sand (zone-III) derived from natura sources: 3 graded stone aggregate 20 mm nominal size derived from natura sources). |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement |
| 10 | 1:1.5:3 (1 cement : 1.5 Pulverised sand (zone-III) derived from natura sources: 3 graded stone aggregate 20 mm nominal size derived from natura sources). |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III)derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 13 | Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Suspended floors, roofs, landings, balconies and access platform |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 18 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 19 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 20 | Using M.S. angels 40x40x6 mm for diagonal braces |
| 21 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 22 | Electric resistance or induction butt welded tubes |
| 23 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 24 | G.I. pipes |
| 25 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 26 | Ordinary cement without any pigment |
| 27 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 28 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 29 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 30 | Size of Tile 600 x 600 mm |
| 31 | Extra for providing and fixing wind ties of 40x 6 mm flat iron section. |
| 32 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 33 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 34 | Ridges plain (500 - 600mm) |
| 35 | 6 mm cement plaster of mix : |
| 36 | 1:3 (1 cement : 3 fine sand) |
| 37 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : |
| 38 | Two or more coats on new work |
| 39 | Distempering with 1st quality acrylic distemper (ready mixed), having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and required shade and colour complete to give and even shade. |
| 40 | Old work (one or more coats) |
| 41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 42 | One or more coats on old work |
| 43 | Finishing walls with textured exterior paint of required shade : |
| 44 | Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. |
| 45 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. |
| 46 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 47 | For thickness of tiles 10 mm to 25 mm |
| 48 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 49 | G.S. Sheet |
| 50 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 51 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 52 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 53 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 54 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 55 | 10 litre capacity - White |
| 56 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 57 | Semi rigid pipe |
| 58 | 32 mm dia |
| 59 | Providing and fixing soil, waste and vent pipes : |
| 60 | 100 mm dia |
| 61 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 62 | 15 mm nominal outer dia Pipes |
| 63 | Providing and fixing brass bib cock of approved quality : |
| 64 | 15 mm nominal bore |
| 65 | Providing and fixing brass stop cock of approved quality : |
| 66 | 15 mm nominal bore |
| 67 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 68 | 25 mm nominal bore |
| 69 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 70 | 15 mm nominal bore |
| 71 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 72 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 73 | 15 mm nominal bore, 107 mm long, weighing not less than 110 gms |
| 74 | ELECTRICAL WORKS |
| 75 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 76 | Group C |
| 77 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required |
| 78 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 79 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 80 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 81 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 82 | Installation, testing and commissioning of pre-wired fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 83 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 84 | Single Pole |
| 85 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 86 | 40 Amps, 2 Pole Isolator |
| 87 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 88 | Providing and laying earth connection FRLS on earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe FRLS on earth electrode including connection with copper thimble excavation and re-filling as required. |
| 89 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthingas required. |
| 90 | Supplying and fixing following rating, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB /Isolator) |
| 91 | 4 way, Double door |
| 92 | Supplying of LED Lamp 9W (MAKE : WIPRO TEJAS 9W ) (Make: Bajaj/ Havells /Usha /Orient/Crompton or equivalent to ISI standard) |
| 93 | Supplying of prewired LED tube light 20W LUMEN output 2000lm 6500K Product code PANASONIC PBTM02203 or equivalent to ISI standard.(Havells/Panasonic/Polycab) or Equivalent to ISI Standarad. |
| 94 | Supplying and fixing rewirable porceline with fuse unit of 32 to 40 amps on energy meter board. |
| 95 | Providing and fixing of Syntex box of size 310mm x 180mm for fixing of Energymeter etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender