Tender For Work Of Installing Split Ac In The Court Room And Retiring Room Of District Judge/Additional District Judge In District Court Mau.
Tender Value
54.85 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
13 days left
EMD
5.49 Lakhs
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Azamgarh → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Work Of Installing Split Ac In The Court Room And Retiring Room Of District Judge/Additional District Judge In District Court Mau.
BOQ
| Sl. No. | Item Description |
| 1 | Part-A Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 Degree Celcius (out door ambient temperature). Inverter Type - Cooling only - 1.5 TR with 5 Star BEE Rating Make Panasonic,Carrier, Blue star, LG |
| 2 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52 Degree Celcius (out door ambient temperature). Inverter Type - Cooling only - 2.0 TR with 5 Star BEE Rating Make Panasonic,Carrier, Blue star, LG |
| 3 | SITC of 5 kVA Automatic Voltage Stabilizer (130-280V) Copper Winding |
| 4 | SITC of 4 kVA Automatic Voltage Stabilizer (130-280V) Copper Winding |
| 5 | Supply and Laying of 2.5 Sq mm 4 Core round copper cable for indoor unit to outdoor unit |
| 6 | Supply and Laying of 2.5 Sq mm 3 Core round copper cable for stabilizer to indoor unit |
| 7 | SITC of Suction/ Discharge both copper pipe line in split AC unit 1.5 Ton capacity including brazing, nitrile rubber insulation 6mm thick class 'O' etc. complate 1/4\\" (6.40mm) and 1/2\\" (12.70mm) |
| 8 | SITC of Suction/ Discharge both copper pipe line in split AC unit 1.8/ 2.0 Ton capacity including brazing, nitrile rubber insulation 9mm thick class 'O' etc. complate 3/8\\" (9.50mm) and 5/8\\" (15.90mm) |
| 9 | Supply and Laying of Heavy Duty PVC Plastic braided 20mm OD flexible pipe for condensed water drain with clipping accessories complete |
| 10 | Cost of providing and fixing MS angle iron stands for mounting outdoor units for split AC |
| 11 | Supply , Fabrication and Installation of M.S. cage for protection of Outdoor unit from animal/theft L X W X H 1300 mm X 600 mm X 1200 mm complete in all respect |
| 12 | Part-B Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire DSR No. 1.14.4 |
| 13 | Supplying and fixing of 25 Amp modular socket oulet and 25 Amp SPMCB DSR No. 1.57 |
| 14 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 Way (4+12) Double Door DSR No. 2.5.1 |
| 15 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 200 A, 36 kA, FP MCCB DSR No. 2.2.15 |
| 16 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 125 A, 30 kA, FP MCCB DSR No. 2.2.14 |
| 17 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way (4 +12), Double door DSR No. 2.4.1 |
| 18 | S/F of 63 A 4 Pole MCB |
| 19 | Suppling & Laying and fixing of one number PVC insulated and PVC sheathed power cable of 1.1 KV grade of following size on wall surface as required - 35 Sq mm 3-1/2 Core SOR 20.1.11 |
| 20 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole DSR No. 2.10.1 |
| 21 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. DSR No. 2.11 |
| 22 | Suppling & Laying and fixing of one number PVC insulated and PVC sheathed power cable of 1.1 KV grade of following size on wall surface as required - 120 Sq mm 3-1/2 Core SOR 20.1.15 |
| 23 | Suppling & Laying and fixing of one number PVC insulated and PVC sheathed power cable of 1.1 KV grade of following size on wall surface as required - 70 Sq mm 3-1/2 Core SOR 20.1.13 |
| 24 | Suppling & Laying and fixing of one number PVC insulated and PVC sheathed power cable of 1.1 KV grade of following size on wall surface as required - 16 Sq mm 4 Core SOR 20.1.9 |
| 25 | Supplying and making end termination with brass compression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3-1/2 x 150 Sq mm DSR No. 11.1.26 |
| 26 | 3-1/2 x 70 Sq mm DSR No. 11.1.23 |
| 27 | 3-1/2 x 35 Sq mm DSR No. 11.1.21 |
| 28 | 16 Sq mm 4 core DSR No. 11.1.33 |
| 29 | S/I of 1800mm x 900mm x 12 mm thick chequered rubber matting of tested quality |
| 30 | S & F of Door Closer DSR No. 9.83 |
| 31 | Supply & fixing of Co2 type fire extinguisher, 4.5 kg capacity (ISI Marked IS:2878 & TAC approved) complete with intial charge and wall bracket along with supply of all materials and labour for proper completion of work. |
| 32 | S/F of 2 mm Thick transparent polythin cartain wirh all associries. Complete in all respect |
| 33 | Part-C SITC of LT Panel vermin proof, floor mounting, MS Channel base with bottom and fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with Powder Coated paint of shade as per direction of Engineer-In-Charge after proper sheet teatment process of sheet steel. The bus bar of panel shall be of Electrical grade high conductive Aluminium alloy of appropriate cross section as per rating. The main bus bar shall run throughout the panel of rating as main incomer rating. The bus bar shall be supported by non hygroscopic SMC/DMC bus bar aupports which shall be mounted on proper interval to ensure the bear the jerks of short circuit of 50kA for panels having ACB as incomer & 36 kA for panels having MCCB incomers. Panels shall be constructed in fullly segregated compartment design for each feeder aas per 3b construction format. The panel shall be completed in all respect as per IS:8623 Part 2&3. There shall be seperate metering compartment for incomer metering and outgoing metering. All Incomer feeders shall be provided with multi function metering along with phase indicating lights and other associated components such as CT, Control MCB, Terminal block etc. amd all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase indicating lights and other associated components such as CT, Control MCB, Terminal Block etc. The Feeders above shall be provided as accomodated all measuring instruments shall be digital type & all indicating lights shall be LED type. Wiring shall be done from 1100V grade PVC insulated copper flexible wire. All ACB shall be electrically operated draw out type with Micro Processor based O/L, S/C & E/F Release of breaking/ Withstand capacity (ICU/ICs/Icw) 50kA or more. All MCCB shall be thermal magnetic/ Microprocessor with O/L & S/C protection along with required spreaders and extended rotary handle with pad locking facility of Breaking Capacity (ICU/ICS) 36kA or more. All MCB shall be Therrmal 10kA 'C' Curve. Cubical type Swith Board Panel Cat B. Incoming - 400 Amp/ 415 Volt ACB - 1 No., Outgoing - 200 A 4 Pole MCCB - 2 Nos., 100 A 4P MCCB - 1 No. 63 A MCCB 1 Nos SOR 20.2.1 |
| 34 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required DSR No. 5.6 |
| 35 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) DSR No. 5.8 |
| 36 | Supply and Laying of Aluminium Conductor PVC insulated armoured served sheathed cables 11OOV grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suitable 20.1 size or as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. -185 Sq mm X 3-1/2 Core (Two Run) PWD SOR 20.1.17 |
| 37 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3-1/2 x 185 Sq mm DSR No. 11.1.27 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysJul 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender