Tender For Supply, Delivery, Erection And Commissioning Of 100 Mm Dia Electromagnetic Flow Meter Kolanthanur In Ward-19 At Karur City Municipal Corporation.
Tender Value
14.70 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
8 days left
EMD
1.47 Lakhs
Bank guarantee accepted
Document Fee
14.70 Lakhs
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Karur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Delivery, Erection And Commissioning Of 100 Mm Dia Electromagnetic Flow Meter Kolanthanur In Ward-19 At Karur City Municipal Corporation.
BOQ
| Sl. No. | Item Description |
| 1 | Cutting the existing BT surface including clraing away from the site etc., complete |
| 2 | Dismantling the RCC Cluvet inculding clearing away from site etc., complete |
| 3 | Earthwork excavating and depositing on bank with an initial lead of 10 metres and initial lift of 2 metres in Sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soil including excavated earth SS 20 A |
| 4 | Supply and delivery 90 mm dia of HDPE PIPES - PE 100 AS PER IS 4984/2016 as per directed as directed by dept officers. |
| 5 | Supply and delivery of 100 G I Pipes (Medium) As Per Is 1239/Part I/2004 as directed as directed by dept officers. |
| 6 | Lowering of 90 mm HDPE PIPES - PE 100 AS PER IS 4984/2016 and specials in the trenches and laying to proper grade and alignment andas directed as directed by dept officers. |
| 7 | Lowering 100 mm dia GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed as directed by dept officers. |
| 8 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 9 | Testing of pipes for water supply with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure inconvenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc., complete for the following diametres of pipes.s Per as directed by dept officers. |
| 10 | 90mm HDPE PIPES - PE 100 AS PER IS 4984/2016 |
| 11 | 100 mm dia GI pipe |
| 12 | Dewatering using 7.5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. |
| 13 | providing 100 mm dia GI pipe Welding as directed by the departmental officers for the sizes |
| 14 | Supply and delivery 100 mm daa of DI D/F Gate (sluice) valves (soft seated) resilient seated soft sealing Gate Valves (Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or GGG 50, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16 |
| 15 | Supply and delivery of 50 mm dia Kinetic Air Valves For Handling More Volumes Of Air In Pumping Main, Double Orifice Kinetic Air Valve Confirming To Is 14845 Tamper Proof Design (Pn-1) Per as directed by dept officers. |
| 16 | Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. Per as directed by dept officers. |
| 17 | 50mm dia |
| 18 | 100mm dia |
| 19 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.- Mixing by manual means |
| 20 | Refilling with excavated soil (other than sand) complying with standard specification for filling in foundation and baasement as directed by the Department officers |
| 21 | Supply, Delivery, Erection and Commissioning of 100 mm Dia Electromagnetic flow meter which shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of kilolitres and shall be accurate within 0.5% of measured value, shall operate within a range of 0.3m/sec to 4m/sec and be constructed as follows:Meter tube(sensor) shall be fabricated from stainless steel and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber preferably SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects.Signal converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20mA output into minimum 500ohm load and a frequency output of a maximum of 0-10 KHz. The microprocessor based signal converter shall have a self diagnostic test mode and a backlit display that continuously dispalys \\"Rate of flow\\" and \\"Total volume\\". The signal converter housing should be die cast aluminium with glass window. The converrter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven as directed by departmantal officers |
| 22 | Supply, Delivery, Erection, Testing and commissioning of Flow Totalizer with inbuild 4G Communication Modem with RTU Panel.Panel Size (380*600*210), Flow Totalizer Unit, Voltage Control Device (High & Low Voltage Production), 4G/3G/2G Sim Support Modem, MCB, Fuse Terminal, Normal Terminal, Cable Dust, Fan, Light, Limit Switch and Internal Cable wiring. Flow Totalizer : Input SUpply :230VAC, Flow Totalizer is field selectable for mA/V DC or frequency flow rate input signal, for 4-20mA 2 wire transmitter it has a 24V DC transmitter supply as a standard, the input signal can be scaled from 0 to 30000 engineering value and the time base is selectable from Sec/Min/Hour/Day. RS485 serial communication (Isolated)option allows easy interface with PLC/DCS/SCADA systems 4G Modem : Auto GSM/GPRS/EDGE/UMTS/WCDMA/HSDPA/HSUPA/TDD LTE Dual-SIM backup and Modbus RTU Configuration and firmware upgrading via USB and RCMSindustrial design (9 to 36V DC, -40 to +75 °C extended operating SCADA Work: RTU panel to Trichy City Corporation SCADA System integration work. MMIC Development, Report Licance Enable and Every 30Min Data Logging and Every Month Data Submittion Work. |
| 23 | Integration to the Existing SCADA system including cost of required software ,labour charges and all taxes etc., |
| 24 | Supply,Delivery and laying of power Cables & Signal Cables for connecting the field instruments with the PLC panel and other electrical connections including PVC conduits,necessary fittings etc., Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysJul 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender