Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56342845

Tender For Repair/Maint Of Apfc Panel, Air Circuit Breaker And Other Low Voltage Equipments Such As Mccb, Lt Panel, Etc At Af Stn Najafgarh Under Ge (Af) Tughlakabad

Issued by Statutory Bodies & Commissions/Committees · Delhi, Delhi
Tender Value
30 Lakhs
Estimated cost
Bid Submission
29 Jul 2026
19 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Apfc Panel, Air Circuit Breaker And Other Low Voltage Equipments Such As Mccb, Lt Panel, Etc At Af Stn Najafgarh Under Ge (Af) Tughlakabad

BOQ

Name of Work:- REPAIR/MAINT OF APFC PANEL, AIR CIRCUIT BREAKER AND OTHER LOW VOLTAGE EQUIPMENTS SUCH AS MCCB, LT PANEL, ETC AT AF STN NAJAFGARH UNDER GE (AF) TUGHLAKABAD
Sl. No. Item Description
1S&F in replacement of APFC 100 KVAR panel cubical consist of sheet metal steel enclosure of 2 mm thick totally enclosed dust proof duly painted with powder coated fully wired up and ready to connect lead & control lines complete all as specified and directed by Engr-in-charge comprising the following:(i) MCCB 160 A 25 KA 3 pole thermal -1 nos (ii) Capacitor duty contactor for 20 KVAR - 02 nos (iii) Capacitor duty contactor for 10 KVAR - 03 nos (iv) Capacitor duty contactor for 5 KVAR - 06 nos (v) Capacitor 20 KVAR - 2 nos (vi) Capacitor 10 KVAR - 03 nos (vii) Capacitor 5 KVAR -06 nos (viii) MCB 63 A 10 KA TP for 20 KVAR - 2 nos (ix) MCB 25 A 10 KA TP for 10 KVAR - 3 nos (x) MCB 16 A 10 KA TP for 5 KVAR - 06 nos (xi) APFC Relay 12 stage - 1 (xii) Indicating light red - 01 no (xiii) Auto manual selector switch - 11 nos (xiv) Digital volt meter (0-500 V) - 1 (xv) Digital amp meter (0-160 A) - 1 no (xvi) volt meter selector switch - no (xvii) Amp meter selector switch - 1 no (xviii) Indicator light R Y B - 3 nos (xix) CT 160/5 A - 3 nos make AE(xx) Bus bar 200 A 3 strip & N/L 100 A ALU-01 set (xxi) Enclosure suitable size - 01
2M&L for APFC 65 KVAR panel in replacement of cubical consist of sheet metal steel enclosure of 2 mm thick totally enclosed dust proof duly painted with powder coated fully wired up and ready to connect lead & control lines complete all as specified and directed by Engr-in-charge comprising the following:(i) MCCB 100 A 25 KA 3 pole thermal -1 nos (ii) Capacitor duty contactor for 20KVAR - 01 nos (iii) Capacitor duty contactor for 10 KVAR - 04 nos (iv) Capacitor duty contactor for 5 KVAR - 01 nos (v) Capacitor 20 KVAR - 1 nos (vi) Capacitor 10 KVAR - 04 nos (vii) Capacitor 5 KVAR -01 nos (viii) MCB 63 A 10 KA TP for 20 KVAR - 1 nos (ix) MCB 25 A 10 KA TP for 10 KVAR - 4 nos (x) MCB 16 A 10 KA TP for 5 KVAR - 01 nos (xi) APFC Relay 12 stage - 1 (xii) Indicating light red - 01 no (xiii) Auto manual selector switch - 11 nos (xiv) Digital volt meter (0-500 V) - 1 (xv) Digital amp meter (0-160 A) - 1 no (xvi) volt meter selector switch - no (xvii) Amp meter selector switch - 1 no (xviii) Indicator light R Y B - 3 nos (xix) CT 160/5 A - 3 nos (xx) Bus bar 200 A 3 strip & N/L 100 A ALU-01 set (xxi) Enclosure suitable size - 01
3Supply, fabrication, installation & commissioning of dust & vermin proof totally enclosed, outdoor type LT, 3 phase 4 wire feeder pillar box factory made (CPRI approved), double door cubical type of suitable size made by 3.15mm thick ms sheet with MS angle iron frame of size 40 x 40 x 6mm slanting roof, front door opening with locking arrangement complete painted with two coats of synthetic enamel paint over a coat of red oxide primer including necessary PCC, fixing with PCC 1:2:4 of size 0.2mx0.2mx0.2m for 4 Nos legs, inclusive of under mentioned items fixed inside with suitable arrangement vertically operated and internal connection with PVC insulated stranded single core copper cable of suitable size or using insulated copper strip of appropriate size and connection of all incoming and outgoing cable including extended the cable from cable loop if required using aluminium cable terminal sockets / lugs duly crimpled comprising of following:-INCOMING: (i) MCCB, AC 415 volts, adjustable thermal & adjustable magnetic setting, 4 pole current rating 400 Amps, breaking capacity 36 KA= 01 No (ii) 4 strip copper bus bar of size 40x10mm with specific colour (R,Y,B) insulation -01 set(iii) Metering panel comprising, voltmeter and ammeter, digital type with selector switches CTs, control fused and indicating lamps. OUTGOING: (i) MCCB, AC 415 volts, adjustable thermal & adjustable magnetic setting, 4 pole current rating 350 Amps, breaking capacity 36 KA= 01 No.(ii) MCCB, AC 415 volts, 4 pole current rating 200 Amps, breaking capacity 16 KA= 02 No’s. (iii) MCCB, AC 415 volts, 4 pole current rating 40 Amps, breaking capacity 10 KA= 02 No’s. Please Enable Macros to View BoQ information
4Supply, fabrication, installation & commissioning of dust & vermin proof totally enclosed, outdoor type LT, 3 phase 4 wire feeder pillar box factory made (CPRI approved), double door cubical type of suitable size made by 3.15mm thick ms sheet with MS angle iron frame of size 40 x 40 x 6mm slanting roof, front door opening with locking arrangement complete painted with two coats of synthetic enamel paint over a coat of red oxide primer including necessary PCC, fixing with PCC 1:2:4 of size 0.2mx0.2mx0.2m for 4 Nos legs, inclusive of under mentioned items fixed inside with suitable arrangement vertically operated and internal connection with PVC insulated stranded single core copper cable of suitable size or using insulated copper strip of appropriate size and connection of all incoming and outgoing cable including extended the cable from cable loop if required using aluminium cable terminal sockets / lugs duly crimpled comprising of following:-INCOMING: (i) MCCB, AC 415 volts, adjustable thermal & adjustable magnetic setting, 4 pole current rating 400 Amps, breaking capacity 36 KA= 01 No (ii) 4 strip copper bus bar of size 40x10mm with specific colour (R,Y,B) insulation -01 set(iii) Metering panel comprising, voltmeter and ammeter, digital type with selector switches CTs, control fused and indicating lamps. OUTGOING: (i) MCCB, AC 415 volts, adjustable thermal & adjustable magnetic setting, 4 pole current rating 350 Amps, breaking capacity 36 KA= 01 No.(ii) MCCB, AC 415 volts, 4 pole current rating 200 Amps, breaking capacity 16 KA= 02 No’s. (iii) MCCB, AC 415 volts, 4 pole current rating 40 Amps, breaking capacity 10 KA= 02 No’s. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56342845
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 29-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Apfc Panel, Air Circuit Breaker And Other Low Voltage Equipments Such As Mccb, Lt Panel, Etc At Af Stn Najafgarh Under Ge (Af) Tughlakabad
Basic Detail
Tender No GE/TKD-49 of 2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 07 Jul 2026
Submission Date 29 Jul 2026
Open Date 31 Jul 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Not Available
Document List
Tender.pdf
Tendernotice_1 (2).pdf
BOQ_869908.xls
f95a15c5-8879-47e6-bca2-55448de4629e.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Jul 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
pdf

Tender.pdf

pdf

Tendernotice_1 (2).pdf

xls

BOQ_869908.xls

html

f95a15c5-8879-47e6-bca2-55448de4629e.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders