Tender For Certain Repairs To Water Supply Distribution Lines And Other Connected Items At Zone ‘A At Mil Stn Bhuj Under Ge(A) Bhuj.
Tender Value
44 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
19 days left
EMD
88000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Certain Repairs To Water Supply Distribution Lines And Other Connected Items At Zone ‘A At Mil Stn Bhuj Under Ge(A) Bhuj.
BOQ
| Sl. No. | Item Description |
| 1 | Taking up U/S AC/GI/DI/UPVC/PVC water main (incl all fitting) with spigot & socket /MS pipe or any other type of pipe or lead joint incl burning out joint pipe of 200 mm bore for laying complete all as specified and directed. |
| 2 | All as per item 1 above but 150 mm dia bore complete all as specified and directed. |
| 3 | All as per item 1 above but 100 mm dia bore complete all as specified and directed. |
| 4 | All as per item 1 above but 50 mm dia bore complete all as specified and directed. |
| 5 | Material and labour DI pipes of size 200 mm bore with spigot and socket end centrifugally cast class \\"K- 7\\" , Including rubber/ Tyton/ Push on joint in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as directed. |
| 6 | Material and labour DI pipes of size 150 mm bore with spigot and socket end centrifugally cast class \\"K- 7\\" , Including rubber/ Tyton in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and directed. Note: DI fitting joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be removed from site. |
| 7 | All as per item 6 above but 100 mm dia bore complete all as specified and directed. |
| 8 | Supply and Fixing in any length UPVC pipe 100 mm dia pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed. |
| 9 | All as per item 8 above but 80 mm dia bore complete all as specified and directed. |
| 10 | All as per item 8 above but 50 mm dia bore complete all as specified and directed. |
| 11 | M&L DI bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch y juction double branch cross(all socket and spiogat collars caps and plug for the pipe socket & spiogat of pipe size upto 200 mm dia complete all as specified and directed. ( lead /gasket for fitting shall be measured and paid separately) |
| 12 | S & F in repair UPVC Ball valves with operating handle (stop valve) of size 50 mm dia complete suitable for fittings with ASTM - 1785, Schedule 40 UPVC pipes complete all as specified and directed. |
| 13 | S & F in repair UPVC Ball valves with operating handle (stop valve) of size 80 mm dia complete suitable for fittings with ASTM - 1785, Schedule 40 UPVC pipes complete all as specified and directed. |
| 14 | Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed. |
| 15 | Rentring filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed by Engr-in- charge. |
| 16 | Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting pointall complete all as specified and directed. |
| 17 | Hard standing cutting/road cutting for laying of pipe and making surface good with PCC 1:3:6 complete all as specified and directed. |
| 18 | Taking down carefully cast iron sluice valve of size 80 mm to 200 mm bore from CI water mains, complete with all acessories complete all as specified and directed. |
| 19 | S&F in repair sluice valves flanged end, cast iron body, flanged and drilled and non rising type spindle with nut, long body, class P N 1.6, conforing to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed of following size. |
| 20 | (a) 200 mm bore |
| 21 | (b) 150 mm bore |
| 22 | (c) 100 mm bore |
| 23 | M & L for Cutting existing cast iron pipes and reducing for insertion of CI fittings to required length in position for following sizes :- |
| 24 | (a) 150 mm bore |
| 25 | (b) 100 mm bore |
| 26 | Supply and Fix in replacement of Automatic Star Delta starter for 75 HP motor which includes 2 contactors of 70A ,1- contactor of No of 40A ,1-No of Thermal over load relay of capacity 45 to 75A ,1-No of Timer ,1-N0's of Volatge sensing relay,control wiring ,MCB,push buttons,Indicating lamps, and other necessary control wiring including mounted of existing place with necessary civil work,nut & bol etc complete all as specified and directed. |
| 27 | Supply and Fix in replacement of Automatic Star Delta starter for 50 HP motor which includes 2 contactors of 50A ,1- contactor of No of 40A ,1-No of Thermal over load relay of capacity 45 to 75A ,1-No of Timer ,1-N0's of Volatge sensing relay,control wiring ,MCB,push buttons,Indicating lamps, and other necessary control wiring including mounted of existing place with necessary civil work,nut & bol etc complete all as specified and directed. |
| 28 | Supply and Fix in replacement of Automatic Star Delta starter for 40 HP motor which includes 2 contactors of 40A ,1- contactor of No of 30A ,1-No of Thermal over load relay of capacity 45 to 75A ,1-No of Timer ,1-N0's of Volatge sensing relay,control wiring ,MCB,push buttons,Indicating lamps, and other necessary control wiring including mounted of existing place with necessary civil work,nut & bol etc complete all as specified and directed. |
| 29 | Supply and Fix in replacement of Automatic Star Delta starter for 30 HP motor which includes 2 contactors of 30A ,1- contactor of No of 20A ,1-No of Thermal over load relay of capacity 45 to 75A ,1-No of Timer ,1-N0's of Volatge sensing relay,control wiring ,MCB,push buttons,Indicating lamps, and other necessary control wiring including mounted of existing place with necessary civil work,nut & bol etc complete all as specified and directed. |
| 30 | Supply and Fix in replacement of Automatic Star Delta starter for 20 HP motor which includes 2 contactors of 20A ,1- contactor of No of 12A ,1-No of Thermal over load relay of capacity 45 to 75A ,1-No of Timer ,1-N0's of Volatge sensing relay,control wiring ,MCB,push buttons,Indicating lamps, and other necessary control wiring including mounted of existing place with necessary civil work,nut & bol etc complete all as specified and directed. |
| 31 | S&F MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable 160 Amps 36 KA with including copper tin spreader link complete all as specified and directed. |
| 32 | S&F MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable Short circuit current 6-10 In , 4 pole 250 Amps 36 KA with including copper tin spreader link complete all as specified and directed. |
| 33 | S&F MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable 400 Amps 36 KA with including copper tin spreader link complete all as specified and directed. Please Enable Macros to View BoQ information |
| 34 | S&F MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable 400 Amps 36 KA with including copper tin spreader link complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender