Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56342797

Tender For special Repairs To Water Supply Installation And Connected Works At Hqtc

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Jul 2026
18 days left
EMD
87896
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repairs To Water Supply Installation And Connected Works At Hqtc

BOQ

Name of Work:- SPL REPAIRS TO WATER SUPPLY INSTALLATION AND CONNECTED WORKS AT HQTC
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) BANGALORE NAME OF WORK :SPL REPAIRS TO WATER SUPPLY INSTALLATION AND CONNECTED WORKS AT HQTC CA NO: GE(AF)/B/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words)
2Supply and laying in replacement GI tubing medium grade including all fittings such as bends, tees, nipples, check nuts, union etc., as per site requirement in trenches/ fixed on walls/ roof/ fixed inside the shallow well as directed further following size including taking down existing rusted/corroded GI tubing complete all as specified and directed:-Note: Earth work and excavation shall be measured and paid separately under relevant items.
3GI tubing 80mm bore
4tubing 50mm bore
5GI tubing 40mm bore
6GI tubing 25mm bore
7GI tubing 20mm bore
8S&F in repairs Gun metal gate valve non rustable spindle with cast iron wheel as per site requirement ISI marked suitable for screwing in GI pipes complete all as specified and directed including taking down existing of following size :
950mm dia
1040mm dia
1125mm dia
1220mm dia
1315mm dia
14S&F in repairs GI coated MS flange of 8mm thick with suitable size drilled holes and suitable for screwing in GI pipe of following size including taking down the unserviceable MS flange complete all as specified and directed :-
15100mm dia
1680mm dia
1750mm dia
1840mm dia
19S&F sluice valve with cast iron wheel stainless steel spindle water, quality conforming IS - 14846 - 2000 class PN - 1/1.6 short bodies ISI marked as per site requirement of the following size including taking down unserviceable sluice valves all as specified & directed of following sizes:--
20150 mm dia
21100 mm dia
2280 mm dia
23200 mm dia
24S&F Non return valve with water quality conforming IS - 14846 - 2000 class PN - 1/1.6 short bodies ISI marked as per site requirement of the following size including taking down unserviceable Non return valves complete all as specified and directed for following sizes:--
25150 mm dia
26100 mm dia
2780 mm dia
28200 mm dia
29S&F in repairs air release valves with single air Outlets, conforming to IS 14845 and fixing up in existing Water supply mains ISI marked as per site requirement of the following size including taking down unserviceable air release valves complete all as specified and directed for following sizes:--
30200 mm dia
31150 mm dia
32100 mm dia
3380 mm dia
34Taking down old/corroded MS bolts from sluice valve, pump, MS bolt and nuts for flange joints of size not exceeding (5 / 8\\") 16mm dia of any length including supply and replace with new bolts, nuts and washers complete all as specified and directed.
35S&F Foot Valve conforming to IS 4038, including nuts bolts washers and rubber 150 mm dia confirming to IS-4038 including taking down the unserviceable valve complete all as specified and directed.
36S&F Foot Valve conforming to IS 4038, including nuts bolts washers and rubber 100 mm dia confirming to IS-4038 including taking down the unserviceable valve complete all as specified and directed.
37S&F Foot Valve conforming to IS 4038, including nuts bolts washers and rubber 80 mm dia confirming to IS-4038 including taking down the unserviceable valve complete all as specified and directed.
38S&F Foot Valve conforming to IS 4038, including nuts bolts washers and rubber 65 mm dia confirming to IS-4038 including taking down the unserviceable valve complete all as specified and directed.
39Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor of cross sectional area 10 sqmm 2 core and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified and directed.
40All as per item No- 12.00 here-in-before but of size 95 sqmm 3.5 core.
41M&L for straight through joints heat shrink type for XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 70 sqmm to 120 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed.
42Supply,Installation,testing and commissioning in replacement Manually operated Changeover Switch TPN, 4 pole of capacity 400 Amps, 415 Volt in sheet steel enclosure including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed.
43Supply and installation, testing, commissioning indoor type floor mounted LT panel made out of 2mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made & MS angle section of at least 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & vermin proof , gasket, suitable for operation on 440 volts, 50Hz, 3 Phase 4 wire AC supply including bus bar chamber and aluminium bus bar of 400 Amps 4 nos mounted on hygroscopic insulators,all pre wired with suitable size of copper conductor cable including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/plateform of the LT panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories. Alongwith With Under/Over voltage, timer, selector switch and phase reversal protection, Single Phase Preventers, Main Contactor, Star Contactor, Delta Contactor, Star-Delta Timer, Dry Run Protection Relay, Thermal Overload Relay ; Wiring and connecting the switchgears and accessories with suitable ratio of CTs – 01 No & PT - 01 including supply and fixing of follwing switchgear items complete all as specified and as directed :-
44Incoming:(a) MCCB 4 Pole,250 Amps, 415 volt of breaking capacity not less than 36 KA -2 No(b ) Digital type ammeter composite type with suitable CT, 0-500 amps -1 No.(c ) Indicator lamp LED type set of three(R,Y,B) - 1 No(d) Digital type Voltmeter composite type with ,0-500 Volts -1 No.Outgoing:(a) MCCB 4 Pole,160 Amps, 415 volt of breaking capacity not less than 35 KA-2 Nos(b) MCCB 4 Pole,100 Amps, 415 volt of breaking capacity not less than 25 KA-1 Nos (c) MCCB 4 Pole,63 Amps, 415 volt of breaking capacity not less than 25 KA- 2 Nos(d) On load change over switch 4 pole 200 Amps - 01 No (d) Fully automatic star delta starter with start/stop push buttons for motors of capacity 60 HP - 02 Nos
45Supply and installation, testing, commissioning indoor type floor mounted panel made out of 2mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made & MS angle section of at least 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, suitable for operation on 440 volts, 50Hz, 3 Phase 4 wire AC supply including bus bar chamber and aluminium bus bar of 200 Amps 4 nos mounted on hygroscopic insulators,all pre wired with suitable size of copper conductor cable including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/plateform of the LT panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories. Alongwith Under/Over voltage, timer, selector switch and phase reversal protection, Single Phase Preventers, Main Contactor, Star Contactor, Delta Contactor, Star-Delta Timer, Dry Run Protection Relay, Thermal Overload Relay ; Wiring and connecting the switchgears and accessories with suitable ratio of CTs – 01 No & PT - 01 including supply and fixing of follwing switchgear items complete all as specified and as directed :-
46Incoming:(a) MCCB 4 Pole, 125 Amps, 415 volt of breaking capacity not less than 25 KA -2 No (b ) Digital type ammeter composite type with suitable CT, 0-500 amps -1 No.(c ) Indicator lamp LED type set of three(R,Y,B) - 1 No(d) Digital type Voltmeter composite type with ,0-500 Volts -1 No.Outgoing:(a) MCCB 4 Pole, 63 Amps, 415 volt of breaking capacity not less than 25 KA-2 Nos(b) MCCB 4 Pole, 40 Amps, 415 volt of breaking capacity not less than 25 KA-1 Nos(c) Float Level Switch for Automatically starting and stoping the pump depending on water level. Pump starts and stops based on programmed level set points. Float switch contacts Pre-wired in the control circuit of the starter/contactor of the pump, Remote monitoring to be Used in water supply plants alongwith MCCB incomer, Contactor + OLR (star-delta as required), Two Float Level Switches, Low level – Pump ON , High level – Pump OFF(d) Fully automatic star delta starter with start/stop push buttons for motors of capacity 20 HP - 02 Nos
47Supply and installation, testing, commissioning indoor type floor mounted panel made out of 2mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply factory made & MS angle section of at least 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof , gasket, suitable for operation on 440 volts, 50Hz, 3 Phase 4 wire AC supply including bus bar chamber and aluminium bus bar of 200 Amps 4 nos mounted on hygroscopic insulators,all pre wired with suitable size of copper conductor cable including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/plateform of the LT panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories. Alongwith Under/Over voltage, timer, selector switch and phase reversal protection, Single Phase Preventers, Main Contactor, Star Contactor, Delta Contactor, Star-Delta Timer, Dry Run Protection Relay, Thermal Overload Relay : Wiring and connecting the switchgears and accessories with suitable ratio of CTs – 01 No & PT - 01 including supply and fixing of follwing switchgear items complete all as specified and as directed :-
48Incoming:-(a) MCCB 4 Pole, 100 Amps, 415 volt of breaking capacity not less than 25 KA -2 No(b ) Digital type ammeter composite type with suitable CT, 0-500 amps -1 No.(c ) Indicator lamp LED type set of three(R,Y,B) - 1 No(d) Digital type Voltmeter composite type with ,0-500 Volts -1 No.Outgoing:-(a) MCCB 4 Pole, 63 Amps, 415 volt of breaking capacity not less than 25 KA-2 Nos(b) MCCB 4 Pole, 40 Amps, 415 volt of breaking capacity not less than 25 KA-1 Nos (c) Float Level Switch for Automatically starts and stops the pump depending on water level. Pump starts and stops based on programmed level setpoints. Float switch contacts Pre-wired in the control circuit of the starter/contactor of the pump, Remote monitoring to be Used in water supply plants alongwith MCCB incomer,Contactor + OLR (star-delta as required),Two Float Level Switches, Low level – Pump ON , High level – Pump OFF(d) Fully automatic star delta starter with start/stop push buttons for motors of capacity 12.5 HP - 02 Nos
49Supply, installation,commisioning and testing out door type LT Panel made out of mild steel CRCA sheet of 3.15 mm thick with angle iron frame of size 50mm x 50mm x 6mm with canopy top,two side ventilators,front openable hinged, double door shutters with locking arrangement (including lock & key), weather & vermin proof, gasket, suitable for operation on 440 volts, 50Hz, 3 Phase 4 wire AC supply including bus bar chamber and aluminium bus bar of 200 Amps 4 nos mounted on hygroscopic insulators,all pre wired with suitable size of copper conductor cable including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/plateform of the LT panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories. Alongwith Under/Over voltage, timer, selector switch and phase reversal protection, Single Phase Preventers, Main Contactor, Star Contactor, Delta Contactor, Star-Delta Timer, Dry Run Protection Relay, Thermal Overload Relay ; Wiring and connecting the switchgears and accessories with suitable ratio of CTs – 01 No & PT - 01 including supply and fixing of follwing switchgear items complete all as specified and as directed :-
50Incoming:(a) MCCB 4 Pole, 63 Amps, 415 volt of breaking capacity not less than 25 KA -2 No (b ) Digital type ammeter composite type with suitable CT, 0-500 amps -1 No.(c ) Indicator lamp LED type set of three(R,Y,B) - 1 No(d) Digital type Voltmeter composite type with ,0-500 Volts -1 No.Outgoing:(a) MCCB 4 Pole, 40 Amps, 415 volt of breaking capacity not less than 25 KA-2 Nos(b) MCCB 4 Pole, 32 Amps, 415 volt of breaking capacity not less than 25 KA-1 Nos(c) Float Level Switch for Automatically starts and stops the pump depending on water level. Pump starts and stops based on programmed level setpoints. Float switch contacts Pre-wired in the control circuit of the starter/contactor of the pump, Remote monitoring to be Used in water supply plants alongwith MCCB incomer,Contactor + OLR (star-delta as required),Two Float Level Switches, Low level – Pump ON , High level – Pump OFF(d) Fully automatic star delta starter with start/stop push buttons for motors of capacity 10HP - 02 Nos
51S&F LED street light fitting 90 watts,240 Volt, single phase, AC, outdoor type with pressure die-cast housing, toughened glass with IP66 protection with 4 Kv in-built and 10 Kv external surge protection complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed .Make: Bajaj ZELA P 120 L WH PO TG SD or Techno-commericially equivalent in Havells/Philips/Wipro.
52S&F LED post-top light fitting 20 watts made in die-cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser and IP 65 protection with 20 watt LED bulb including taking down unserviceable fitting, complete all as specified & directed.Make Bajaj BGCTN 25 W LED WH or Techno-commericially make of Havells,CG.
53M&L for sub main wiring from street light fitting to junction box with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 1.5 sqmm in and including heavy grade PVC conduit and its accessories with fixing arrangements on pole surface, wall, ceiling etc including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC conduit and two run of copper conductor together taken as one length for measuring unit length.
54Disconnecting and taking out old existing unserviceable PVC cable loop box and supplying and fixing with pole PVC cable loop box, size not less than 145 mm x 145 mm x 95 mm, out door type, IP 65 including porcelain insulated connectors for incoming and outgoing 4 core cables with one MCB SP 6 amps 230 volts connected to street light fitting sub main wire and using FI clampsof size 20mm x3 mm for fixing of PVC cable loop box with pole,including nuts,bolts & washers and connecting the cables to connectors with using suitable size GI nut, bolts and washers and aluminum lugs etc and complete all as specified & directed.
55Disconnecting and taking out old rusted/ unserviceable light fitting’s bracket incl FI clamps of any description and in any position and supplying and fixing brackets made out of 50 mm dia light grade GI pipe 1.50 mtr long bent to shape and size as per site requirement for fixing of street light fitting on poles/ walls including Flat Iron clamps=02 Nos of size 30x5mm made to shape incl nuts,bolts & washers complete all as specified and directed.
56S&F GI pipe light grade of 50 mm dia for cable protection on pole/ wall/ floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc complete all as specified and directed. (for street light from bottom of pole upto junction box)
57Supply, installation and erection in replacement steel tubular swaged welded poles complete with MS base plate of 6mm thick of size 300mmx300mm at bottom duly welded and MS pole cap at top, poles shall made out of ERW MS tubing confirming to IS-1161 part-II, type 410 SP -31(9.0m long) including drilling of holes of required size and nos for fixing of cross arms/clamps, poles shall be painted internally throughout using anti corrosive black bituminous paint and externally painted with two coat of red oxide primer and two coats of aluminum paint for expose surface and two coats of black bituminous paint for portion embedded in concrete,painting three alternating layer of each black and yellow paints at lower portion of pole each of 300mm height at 300mm spacing, writing pole no. with black paint in yellow paint circle 10cm dia at suitable height complete all as specified and directed.Note:- Any wire, any type cable, any type box, CCTV camera, any type street light fitting, poster,picture or any items fixed with pole shall be taken down carefully and safely and refixed with new steel pole in same position in quoted rates.
58M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
59Taking down carefully copper/aluminium point wiring (light, fan,socket or power) complete, including fittings & fixtures such as switches, sockets,ceiling rose, pendants, regulators, light fittings etc. Removing materials to store for keeping in safe custody for taking credit and making good to disturbed surfaces with plaster & matching with the existing colour of wall/floor etc complete all as specified & directed.
60Taking down carefully ceiling fan from ceiling, dismantling blades, and removing fan and painting of ceiling fans complete, with one coat synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc. and refixing of ceiling fan in same position in serviceable condition with greasing and oiling including provision of three core 1.5 sq mm cable from ceiling rose to fan connector complete all as specified & directed.
61Taking down carefully Exhaust fan from wall, cleaning all dust etc. and refixing of exhaust fan in same position in serviceable condition with greasing and oiling including nut ,bolt,washer including provision of three core 1.5 sq mm cable from ceiling rose to exhaust fan complete all as specified & directed.
62M&L for point wiring with 1.5 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Capping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, round/ square PVC blocks at junction for batten holders, ceiling rose etc ,screws, gutti / roul plugs PVC all as per site requirements including fixing on stone walls / brick masonry walls /ceilings /floors etc heavy duty plastic terminal boxes for mounting of modular switches/ sockets/regulator etc and 1.5 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as continuous earth lead connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green.and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc complete all as specified & directed for the following:-
63One light point controlled by one single pole 5 Amps switch.
64One ceiling /wall fan point controlled by one single pole 5 Amps switch.
65One exhaust fan point controlled by one single pole 5 Amps switch.
66One 5 pin socket point 5 Amps on independent board.
67One 5 pin socket point 5 Amps on same board with other switches.
68All as per item No-31.00 here-in-before but for power point wiring with 2.5 Sqmm PVC insulated, unsheathed, FRLS multistranded copper conductor 1100 volt grade cable and 2.5 Sqmm PVC insulated, unsheathed, FRLS multistranded copper conductor 1100 volt grade cable as continuous earth lead for 6 pin 15 Amp switch socket outlet on independent board complete all as specified & directed.
69M&L for sub main wiring with two single core 2.5 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Capping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 2.5 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed. Note-Two runs of 2.5 sqmm single core cable and one run of 2.5 sqmm earth wire including PVC casing & capping together shall be measured as one unit.
70M&L for sub main wiring with two single core 4 .0 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Caping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 4 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed. Note-Two runs of 4.00 sqmm single core cable and one run of 4.00 sqmm earth wire including PVC casing & capping together shall be measured as one unit.
71S&F Modular switch , 1 Module single pole one way 10 Amps complete all as specified & directed.
72S&F Modular switch , 1 Module single pole one way 16 Amps complete all as specified & directed.
73S&F modular socket , 2 Module 6 Amps, 5 pin, 230 volts AC complete all as specified & directed.
74S&F modular socket , 2 Module 6/16 Amps, 6 pin, 230 volts AC complete all as specified & directed .
75S&F PVC ceiling rose 65 x 50 mm surface type with 3 terminals 230 volt complete all as specified & directed .
76S&F Modular type fan regulator upto 120 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm complete all as specified & directed.
77S&F modular white cover plate with frame, 2 module complete all as specified & directed.
78S&F modular white cover plate with frame, 3 module complete all as specified & directed.
79S&F modular white cover plate with frame, 4 module complete all as specified & directed.
80S&F modular white cover plate with frame, 6 module complete all as specified & directed.
81S&F modular white cover plate with frame, 8 module complete all as specified & directed.
82S&F modular metal flush box 1/2 module complete all as specified & directed.
83S&F modular metal flush box 3 module complete all as specified & directed.
84S&F modular metal flush box 4 module complete all as specified & directed.
85S&F modular metal flush box 6 module complete all as specified & directed.
86S&F modular metal flush box 8 module complete all as specified & directed.
87S&F LED lights fitting 4 feet 20 watt , 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed.
88S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed.
89S&F Sheet metal enclosure for DB's double door SPN, 12 ways when MCBs to be used single pole and neutral, deep drawn with 200 Amps rated copper bus bar 230 Volt, complete all as specified & directed.
90S&F Sheet metal enclosure for DB's double door SPN, 8 ways when MCBs to be used single pole and neutral, deep drawn with 200 Amps rated copper bus bar 230 Volt, complete all as specified & directed.
91S&F MCB SP, 6-32 Amps, 230V, C- series with breaking capacity of 10KA complete all as specified & directed.
92S&F MCB SPN, 40 Amps, 230 V, C- series with breaking capacity of 10 KA complete all as specified & directed.
93Construction of valve pit chamber of size 1.2 x 1.2 x 1.2 mtr internal size suitable for sluice valve with PCC 1:3:6 type C2 using 40mm graded aggregate for foundation, on hollow block masonry wall in cement mortar 1:4, 40mm thick PCC 1:2:4 type B1 using 20mm graded aggregate coping, rendering in cement mortar 1:4, 15 mm thick including provision of mild steel sheet cover of 2mm thick on 40x40x6 mm angle iron frame work embedded in concrete with suitable hinges and locking arrangements including two coats of black synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary excavation earth work on any type of soil etc. including removal of surplus soil and rubbish not exceeding 50m distance, complete all as specified and directed.
94M&L PCC 1:3:6 type C2 using 40mm grade aggregate with in foundation/mass concrete complete all as specified and directed.
95Demolition of cement concrete in ground floor and paving in exc 15 cm thickness (below or ground level) etc complete all as specified and directed.
96Excavation in trenches not. exc. 1.5m wide and not exc. 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
97Returning,filling in,including spreading, levelling ,watering and well ramming in layers not exc 25cm thick in soft/loose soil complete all as specified and directed.
98Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
99Cutting the bituminous road of any description to a size n.exc 0.45 x 0.45m for crossing of pipe and making good with cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate complete all as specified & directed.
100M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board,LT panel etc with & including adequate quantity of charcoal dust and common salt around earth plate, PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with pre cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified & directed. Note- The unit rate includes main earthing lead GI earth strip of size 32x6 mm with 40 mm dia GI light grade earth lead protection pipe from earth electrode to test point up to 7.5 mtr.
101M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron steel wire 4mm dia as earthing lead as shown in Electrical Plate No 4 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI med grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, funnel and wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate no-4 of SSR part No1 complete all as specified & directed. Note- The unit rate includes main earthing lead galavanised iron steel wire 4mm dia with 15 mm dia GI light grade earth lead protection pipe from earth electrode to test point up to 7.5 m.
102S&F defective digital water level indicator for OHT and UG sump includign all control wiring for Sensors installed at different heights in the UG sump and OHT with alarm signal complete all as specified & directed.
103S&F defective micro controller IC suitable for digital water indicator micro proceesor based complete all as specified & directed.
104S&F defective buzzer for over flow indication suitable for digital indicator micro processor based complete all as specified & directed.
105S&F defective printed circuit board (PCB) suitable for digital water indicator micro processor based complete all as specified & directed.
106S&F defective Magnetic sensor suitable for micro processor based digital water level indicator fixed at different levels inside sump/OHT for sensing level of water including dismantling of old unserviceable sensor all as directed Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56342797
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 28-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repairs To Water Supply Installation And Connected Works At Hqtc
Basic Detail
Tender No 8527/E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 07 Jul 2026
Submission Date 28 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 87896
Exemption Available
Document List
21f2107a-1c72-4508-9c7e-b9ec92e4582e.html
BOQ_870063.xls
SOC_8527.pdf
Tendernotice_1 (2).pdf
Tender_8527.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

21f2107a-1c72-4508-9c7e-b9ec92e4582e.html

xls

BOQ_870063.xls

pdf

SOC_8527.pdf

pdf

Tendernotice_1 (2).pdf

pdf

Tender_8527.pdf