Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56342790

Tender For Repair/ Maintenance And Attend Day To Day Internal Electrification Complaints Of Lekhanagar Under Age E/M (Es) At Ge (U) Meerut Cantt.

Issued by Statutory Bodies & Commissions/Committees · Meerut, Uttar Pradesh
Tender Value
24 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
19 days left
EMD
48000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Meerut → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance And Attend Day To Day Internal Electrification Complaints Of Lekhanagar Under Age E/M (Es) At Ge (U) Meerut Cantt.

BOQ

Name of Work:- REPAIR/ MAINT AND ATTEND DAY TO DAY INTERNAL ELECTRIFICATION COMPLAINTS OF LEKHANAGAR UNDER AGE E/M (ES) AT GE (U) MEERUT CANTT.
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring of any type, batten or conduit, (Light, Fan, Socket or power) complete incl fittings and making good the disturbed surfaces of walls, ceiling etc in cm and applying two coats of white/colour washing/distempering etc to match the existing surface complete all as specified & directed.
2Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings. (Rate for cutting chasis of walls all are included in the quated rate)
3One light point or one fan point or bell point controlled by one switch or bell push
4One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
5One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch
6All as per serial item No 2 here in before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 /16 Amps socket outlet point on independent board with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed
7Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLSH PVC insulated, unsheathed copper conductor cable in open conduit/casing caping of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, FRLSH PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings.
8One light point or one exhaust fan point controlled by one , one way 05/06 Amp Switch
9One fan point controlled by one , one way 05/06 Amp Switch
10One bell point controlled by one switch
11One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
12One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch
13All as per serial item No 4 here in before but using 2.5 Sqmm nominal cross sectional area single core, FRLSH PVC insulated copper conductor cable, unsheathed for with 2.5 Sqmm FRLSHH earth wire for one 15 /16 Amps socket outlet point on independent board complete all as specified and directed.
14Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLSH PVC insulated, unsheathed copper conductor cable in existing conduit/casing caping of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, FRLSH PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings.
15One light point or one exhaust fan point controlled by one , one way 05/06 Amp Switch
16One fan point controlled by one way 05/06 Amp Switch
17One bell point controlled by one switch
18One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
19One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch
20All as per serial item No 6 here in before but using 2.5 Sqmm nominal cross sectional area single core, FRLSH PVC insulated copper conductor cable, unsheathed for with 2.5 Sqmm earth wire for one 15 /16 Amps socket outlet point on independent board complete all as specified and directed
21Supply & fixing in repair/replacement of switch piano flush type, 05/06 Amps single pole , one way 240 volts complete all as specified & directed .
22Supply & fixing in repair/replacement of bell push, flush type 05/06 Amps, 240 volts complete all as specified & directed .
23Supply & fixing in repair/replacement bell, AC, 230 volts, single pole, compete all as specified & directed.
24Supply & fixing in repair/replacement switch piano flush type, 15 /16 Amps single ploe, one way 240 volts complete all as specified & directed .
25Supply & fixing in repair/replacement of socket outlet 3 pin, 05/06 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed.
26Supply & fixing in repair/replacement of socket outlet 3 pin, 15/16 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed.
27Supply & fixing in repair/replacement of ceiling fan regulator, electronic, type, rotary 0 to 04 steps, hum free, AC, 230 volts, 100 watts duty ISI Marked with and including modular white surround complete all as specified & directed.
28Supply & fixing in repair/replacement lamp holder (Angular/Straight), insulated body, with back plate for batten fitting complete all as specified & directed
29Supply & fixing in repair/replacement of ceiling rose surface bakelite 65x 50mm three terminals complete all as specified & directed.
30S&F in repair/replacement 20 watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorative aluminium extruded T5 LED battens, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 4' long, easy to install, Efficacy minimum :100 lumen/watt, Minimum 3.5 KV Voltage Serge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
31S&F in repair/replacement 10 watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorative aluminium extruded T5 LED battens, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 2' long, easy to install, Efficacy minimum :100 lumen/watt, Minimum 3.5 KV Voltage Serge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
32S & F in repair Recess mounted economical LED panel light 2`X2` 36 watt with high quality diffuser for uniform light with minimum 100lm/w housing of pressed aluminium sheeet with complete all as specified and directed.
33S&F in repair LED Bulk Head Fitting 10 Watt housing made up corrosion resistant unbreakable PC with high quality diffuser for glare free Aesthetically designed gaskit IP65 protection, efficacy minimum 95lm/watt complete all as specified and directed.
34Supply and fix in repair LED post top light for gate light 45 Watt with spun aluminium housing and pressure die-cast spigot. Clear polycarbonate diffuser for uniform bright light, efficacy minimum 95lm/watt, with IP66 degree of protection & impact resistance complete all as specified and directed.
35Demolition and removing from site old PCC and Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, complete all as specified & directed (for foundation of post top and bollard).
36S&F in repair PVC insulated & sheathed stranded copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings including with suitable size copper lugs as in repair complete all as specified & directed.
37M & L in repair for sub main wiring with 1.5 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core , PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing complete all as specified & directed including taking out old u/s sub main wiring any size.
38M & L in repair for sub main wiring with 2.5 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core , PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing complete all as specified & directed including taking out old u/s sub main wiring any size.
39M & L in repair for sub main wiring with 6 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core , PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing complete all as specified & directed including taking out old u/s sub main wiring any size.
40Supplying and fixing in replacement of 10 Sqmm 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, two twin core cable flat or circular complete all as specified and directed.
41Supplying and fixing in replacement of 6 Sqmm 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, two twin core cable flat or circular complete all as specified and directed.
42Supply & fixing in repair/replacement of MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
43Supply & fixing in repair/replacement of MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
44Supply & fixing in repair/replacement of MCB, SPN, AC, 240 volts of 63 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed
45Supply & fixing in repair/replacement of MCB, TPN, 415 volts of 100 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed
46Supply & fixing in repair/replacement of MCB DB Box 8 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed
47Supply & fixing in repair/replacement MCB DB Box 4 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed
48Supply & fixing in repair/replacement of Sheet Metal Enclosures TPN, 4 way, 415 Volt, Double door for housing MCB's/Isolators and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed
49Supply & fixing in repair/replacement of Sheet Metal Enclosures vertical TPN distribution board with provision for & including 100 Amp MCCB TPN as incomer with necessary internal wiring, MCBs as outgoing , 4 way, 415 Volt, Double door for housing MCB's/Isolators and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed .
50S&F MCCB in repair/replacement of 4Pole 415 V fixed type, 100 Amps with breaking capacity 16 KA complete al as specified and directed
51Supply & fixing Sheet Metal Enclosures with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps capacity 240 volts 'B' series 10KA and making connections complete all as specified & directed including taking out old u/s any capacity.
52S&F in repair/ replacement of casing caping 25 mm complete all as specified & directed.
53S&F in repair/ replacement of casing caping 15 mm complete all as specified & directed.
54S&F in repair/ replacement of flexible conduit 25 mm complete all as specified & directed.
55S&F in repair/ replacement of flexible conduit 32 mm complete all as specified & directed.
56S&F in repair Hylum sheet 3 mm thick of 9\\"x5\\" size for fix suitable PT switches/sockets/regulator complete all as specified and directed.
57S&F in repair Hylum sheet 3 mm thick 9\\"x7\\" size for fix suitable PT switches/sockets/regulator complete all as specified and directed.
58M & L for LED Bulb 12 watt 240 volt complete all as specified & directed.
59Supply & Fix in replacement LED Emergency LED linear Lamp, Wattage 10W, Voltage /frequency 220-240V/ 50-60Hz, Cool Day light, PF > 0.9 CCT 6500K, upto 4 Hrs Back up complete all as specified & directed.
60Supply & Fix in replacement Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by GI earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion (GI earth strip will be protected by using 40mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I.
61S&F in replacement of LED Bldg Security light including connecting and testing of energy saving & environment friendly, made out of pressure die cast aluminium housing with toughened glass cover housing, 45 watts LED to achieve electrical safety class 1, Pf >0.95, lumens >110 lm/W, Ingress protection not less than IP66, including 32mm nominal bore light grade GI pipe brackets made out of 1.50M long GI pipe ,bent to shape and fixed to poles/ walls with two Nos mild steel flat iron brackets of 40mmx6mm, comprisng 4 Nos mild steel hexogonal head bolts of 12 mm dia, 75 mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, and making connections with cable complete all as specified and directed.
62Taking down of old existing unserviceable wall fans and S&F wall mounting fan 400 mm sweep BLDC in replacement including making connections with suitable size of copper wire and making good surfaces complete all as specified & directed.
63Taking down of existing unserviceable ceiling fans and Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified & directed.
64Taking down existing unserviceable ceiling fan of 1200mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled copper winding wire, insulation, varnishing, greasing and assemling the fan, cleaning and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose complete all as specified & directed.
65Taking down existing serviceable ceiling fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, checknuts, pin etc. and re-assembling and refixing in position , connecting and testing complete all as specified & directed.
66Taking down existing unserviceable exhaust fan of 450mm/380mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled copper winding wire, insulation, varnishing, greasing and assemling the fan, cleaning and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose complete all as specified & directed.
67Taking down existing serviceable Exhaust fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, check nuts, pin etc. and re-assembling and refixing in position, connecting and testing complete all as specified & directed.
68Taking down of existing unserviceable exhaust fan plastic body 250mm and S&F exhaust fan plastic body 250mm sweep in replacement including making connections with suitable size of copper wire and making good surfaces complete all as specified & directed.
69Renewal of cylinder capacitor 2.5 MFD with earthing terminal for ceiling fan / cabin fan motor including soldered leads for connections ISI-1709, MPP ( metallised polypropylene, SH (self healing), of the following capacities complete all as specified & directed.
70Renewal of cylinder capacitor 4 MFD with earthing terminal for Exhaust fan motor including soldered leads for connections ISI-1709, MPP ( metallised polypropylene, SH (self healing), complete all as specified & directed.
71Supply & Fix in repair of ceiling fan down rod of MS pipe 15mm bore of length as per site measurement including cutting/threading making tide for fixing providing check nuts wachers etc complete all as specified & directed.
72S & F in repair PVC insulated 23/0.0076 flexible cord twin core with stranded copper conductor complete all as specified & directed.
73Taking out unserviceable bush from ceiling fan and making arrangement for ball bearing by lathing at workshop complete all as specified and directed.
74Renewal of mild steel hanging clamps suitable for any sweep of fans including necessary nuts, bolt and washers and split pin complete all as specified and directed.
75Supply and fix in repair of 10 Watt LED bollard light with aluminium pipe housing, fiting for pathways and garden rectangular shaped victorian design, clear/ PC Diffuser spun cover, die cast pole mounting, efficacy 95 lm/watt, IP 65, module including fixing in concrete post suitable size GI pipe complete all as specified and directed.
76Supply and fixing in replacement of decorative wall light white in colour made up of poly carbonate suitable for 9 watt retrofit LED Lamp complete all as specified and directed.
77S&F in replacement of bell, Ding Dong Ac.230 volts,single pole complete all as specified & directed.
78Attending the complaints of non functional ceiling /exhaust fan of any sweep and testing and repairing the ceiling /exhaust fan without taking down by checking/replacing of fan condenser ,fan regulators hanging accessaries and connection of wires etc.,and making fan serviceable complete all as specified & directed.
79Attending the complaints for checking of existing electrical fittings and fixtures in qtrs at sectors area for continuous electric supply including carrying out minor repairs etc as required to make the items functional and replacing tube rods, chokes, CFLs, copper cable , switches, sockets, holders etc as per suitable size and capacity at site complete all as specified & directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56342790
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 24 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance And Attend Day To Day Internal Electrification Complaints Of Lekhanagar Under Age E/M (Es) At Ge (U) Meerut Cantt.
Basic Detail
Tender No 8831/E8
Bidding Type Tender
Location
City Meerut
State Uttar Pradesh
Key Dates
Publish Date 07 Jul 2026
Submission Date 28 Jul 2026
Open Date 04 Aug 2026
Finance
Tender Value 24 Lakhs
Tender Fee 500
EMD 48000
Exemption Available
Document List
9cf964b8-b3c6-4903-b0f3-7c9e66497788.html
AllMakes8831.pdf
BOQ_869983.xls
CreditSchedule8831.pdf
PS8831.pdf
Tender8831.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Aug 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

9cf964b8-b3c6-4903-b0f3-7c9e66497788.html

pdf

AllMakes8831.pdf

xls

BOQ_869983.xls

pdf

CreditSchedule8831.pdf

pdf

PS8831.pdf

pdf

Tender8831.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders