| Sl. No. | Item Description |
| 1 | Taking down Chowkats or frame exc 1.5 sqm but n.exe 4 Sqm each without taking off shutters from the frame complete all as specified and as directed. |
| 2 | Taking down Chowkats or frame n. exc 1.5 sqm but n.exe 4 Sqm each without taking off shutters from the frame complete all as specified and as directed. |
| 3 | S&F 1.25mm thick pressed steel frame for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 105 x60 mm, 1.25mm thick including 100mm size MS hinges with one shop coat of zinc chrome primer complete all as specified and as directed. |
| 4 | S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour printed PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as specified in part 8 of SSR Part-I complete all as specified and as directed. |
| 5 | S&F 30mm thick hard wood factory made flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 6 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, wood free EPS as per specifications and drawing as specified in SSR Part I, Section 8 complete all as directed. |
| 7 | S&F 100mm butt hinges, medium weight cold rolled, MS steel complete all as specified and as directed. |
| 8 | S&F 150mm Aluminium handles cast type anodised complete all as specified and as directed. |
| 9 | S&F 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed. |
| 10 | S&F 250mm Aluminium anodised sliding door bolt, with hasp & staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sections complete all as specified and as directed. |
| 11 | S&F Powder coated aluminium window sliding type three track (2 glazed & one gauze shutter ) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing , screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surface of wall complete all as specified and as directed. |
| 12 | M&L mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as Specified and as directed. |
| 13 | S&F powder coated anodized aluminium door made out hollow extruded aluminium sections as mentioned below. Each door having 02 Nos disk or D type handles of 200mm long, 02 Nos aluminium tower bolt of 200mm size, 1 no mortice lock of six levers with key in duplicate regulated by double acttion hydroulic floor door spring shutter to be paterly glazed with 5mm thick tinned glass and partly panelled with 12mm thick prelaminated particle board fixed with glazing clips rubber beading /gasket anodized aluminium beading screws complete including taking down old unserviceable shutter with frame (a) Chowakat frame : 100 x44 x1.60 mm(b) Shutter verticle style : 100 x44 x1.60 mm(c) Shutter lock rail : 150 x44 x1.60 mm(d) Shutter Top rail : 100 x44 x1.60 mm(e) Shutter bottom rail : 200 x44 x1.60 mm |
| 14 | M&L preparation of new steel and iron surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 15 | M&L preparation of new or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. |
| 16 | M&L for PCC type C-1, 1:3:6 using 20mm graded aggregate as in bed block for fixing of hold fast, filling concrete in back of pressed steel frame filling , gaps in between glazed & fly proof steel window, cills, railling up to 60 cm in height etc including necessary form work as required all complete all as specified |
| 17 | Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc including removing of rubbished material from work site complete all as specified and as directed. |
| 18 | M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick walls or concrete surfaces in two layers (10mm & 5mm) mixed with water proofing compound by weight of cement or as per manufacturer instructions, finished even & smooth without using extra cement all complete all as specified and as directed. Note. Liquid water proofing compound will be measured and paid separtely. |
| 19 | M&L Rendering 5 mm thick on concrete surfaces as in ceiling in cement mortar 1:3 for finished even and fair including taking down plaster complete all as specified and as directed. |
| 20 | M&L rendering 15mm thick plastering in cement mortar (1:6) on on fair faces of brick work and finished the plastered surface fair and even without using extra cement.complete all as specified and as directed. |
| 21 | Supply only Liquid water proofing compound complete all as specified and as directed. |
| 22 | M&L for preparation of new plastered surfaces on wall / ceiling / chajjas and applying Two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 Ltre/10 Sqm over and including priiming coat of exterior primer applied @ 0.90 litre/10 Sqm over new/old surfaces as per the manufacturer instructions complete all as specified and as directed. |
| 23 | M&L preparation new internal wall surfaces and apply two coats of 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/ltr of approved shade and colour over a coat of primer complete all as specified and as directed. |
| 24 | M&L preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white wash including washing floors, cleaning glass, joinery, electrical fittings, wiring etc. of drops and splashes complete all as specified and as directed. |
| 25 | M&L complete removal of existing finishes from wall surfaces and applying 1mm thick wall care putty,apply two coats of 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/ltr of approved shade and colour over a coat of primer complete all as specified and as directed. |
| 26 | M&L preparation of old treated surface of wall by brooming down or steel wire brushing; scrapping down smoke root, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on old decorated surfaces of wall including washing froors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and directed. |
| 27 | M&L complete removal of existing treatment of old decorated treatment on wall / ceiling / chajjas by scrapping with true care wall sander to make the surface free from dust, loose paints etc.with sanding machine having sanction vacuum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per the manufacturer instruction complete all as specified and as directed. |
| 28 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises including taking down cement plaster complete all as specified and as directed. |
| 29 | M&L for non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but n. exc. 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in whiter or coloured cement to match as in floor over and including cement screed bed / backing layer of 15mm thick in cement mortar (1:6) complete all as specified and as directed.Note:- Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work. |
| 30 | M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but n. exc. 0.36 Sqm, in skirting etc. set and jointed in neat cement slurry and pointed in whiter or coloured cement to match including screed bed or beded layer 10mm thick in cement 1:4 complete all as specified and as directed. |
| 31 | M&L for 15-18 mm thick Granite work ( table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar ( 1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screeding in cement mortar 1:4 including full rounding the exposed surfaces and provision of holes for LPG gas pipe etc complete all as specified and as directed. Note: (a)Granite colour shall be approved by Engr-in-charge /GE at the time of execution of work. |
| 32 | Demolition of brick brick of built in cement morter including all quoins, arches, pillars, etc, complete all as specified and as directed. |
| 33 | M&L brick works with fly ash bricks straight or curved on plain exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed |
| 34 | Demolition of wall and ceiling board (Fibre, pulp, insulation etc) or insulation board/ slab/ blankets of any thickness including cover fillet complete all as specified and as directed |
| 35 | Supply & fixing false ceilling with Gl powder coated frame work and 4 mm thick,(E-board) non asbesto fibre reinforced cement board, reinforced design board tiles conforming to IS-14862,of approved texture at aii height duly suspended ceilling laid on hot dip galvanised iron imposed drid of size 600 mm x600 mm ,T section/ Angle section including cutting holes in brick wall and making good surface with cement concrete 1:2:4 type B-0/1:3 cement mortar complete all as specified and having following details.(a) 27mm x 27mm angle 0.55 mm thickness,GI powder coated hot dip glvanised plugged at the rate 600mm centreto center alongwith te perimeter of wall.(b) 25 mmx 25 mm Tee 0.55 mm thickness,GI powder coated hot dip galvanised as main and cross runner suspended with 1.6 mm dia GI wire suspendrs (not exc 1.2 mtr length) with ajustable clamps and dash true fastners plugged in RCC slab or angle iron runner of slopped roof placed at the rate 600 mm centre to centre alongwith the premeter of wall.Note : The work shall be carried out as per manufacturer instruction and as directed. |
| 36 | S&F for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specificationsand drawing complete all as specified and as directed. |
| 37 | S&F for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed. |
| 38 | Dismantling of plan or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering complete all as specified and as directed. |
| 39 | S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 40 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 41 | M&L Roof trusses (framed), trussed, purlins,rafter, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, tubular or flat sections) including distance pieces, cleats, plate etc.confirming to Fe-410w(Gde E-250, quality A) complete all as specified and as directed. |
| 42 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing etc., and making good, cutting not exceeding 10 cm girth in brick walls complete all as specified and as directed. |
| 43 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc 15cm thickness (below or above ground level) complete all as specified and as directed. |
| 44 | M&L for 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 86/25 grade and three parts of sand by weight complete all as specified and as directed. |
| 45 | M&L 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in path and and finishing the surface even and rough to receive the topping layer or tiling complete all as specified and as directed. |
| 46 | M&L cement concrete type C1 1:3:6 with 20 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed. |
| 47 | Providing and laying heavy duty 300 x 300mm & 12mm thick anti skid pavement tile (color & Shade as approved) set and jointed in neat cement slurry and pointed in white cement & pigment to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed. Notes:- Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work. |
| 48 | Taking up or down steel tubing and connection, including cleaning for refixing or removal to store of 15mm bore complete all as specified and as directed. |
| 49 | S&F of Tubes, medium grade, 15mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete. |
| 50 | Taking up or down steel tubing and connection, including cleaning for refixing or removal to store of 20mm bore complete all as specified and as directed. |
| 51 | S&F of Tubes, medium grade, 20mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed. |
| 52 | Dismantling water tank exc 500 & n. exc 1000 ltr capacity and removing to store complete all as specified and as directed. |
| 53 | S&F 500 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed. |
| 54 | S&F in repair, 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms.) complete all as specified and as directed. |
| 55 | S&F in repair, 15 mm bore Bib taps, chromium plated fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 56 | S&F in repairs sinks with drainage board made of stainless steel 1mm thick sheet plugs, washers and waste pipe, including a pair of cantilever brackets embedded in wall with suitable size of PCC (1:3:6) type C-1 blocks and connecting union to pipe of overall size 915mm x 460mm & bowl size 410mm x 330mm x 160mm all complete all as specified and as directed |
| 57 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 58 | M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Fins, fascias, louvres, parapets, chajja/sunshade, shelves and railings , newels, balustrade & the like complete all as specified and as directed |
| 59 | Formwork to fins, louvers, fascia, RCC shelf, fair finished surfaces of concrete flat complete all as specified and as directed |
| 60 | M&L TMT bar 6 to 8mm mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 61 | Taking down old existing tarfelt/concrete of any type/description and course from roof surface including adjoining parapets and removing the debries from the site including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and derected. |
| 62 | M&L 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC in order to maintain proper slope over existing roof surfaces for laying APP base polymeric membrane, finished even and smooth without using extra cement complete all as specified and derected. |
| 63 | M&L for Providing, cement concrete Type B1 1:2:4 using 20 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. |
| 64 | M&L water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top (i) Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried complete(ii) Rendering 10mm thick in CM (1:4) on existing roof surface true to level after applying cement slurry @ 3Kg/Sqm..(iii) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm.(iv) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.60 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 150gms per Sqm. Polymeric membrane shall be taken to a height as required at site/30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing.(iv) One coat of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions.Note : (a) Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.(b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction. |
| 65 | Excavation in post holes of soft/loose soil (or similar holes) each n. exc 0.5 cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in soft/loose soil and watering and removing surplus soil to distance complete all as specified and as directed. |
| 66 | M&L for PCC in cement concrete in foundation filling and mass concrete type C-2, 1:3:6 using 40mm graded aggregate as in foundation filling and mass sub base complete all as specified and as directed. |
| 67 | M&L framed work in tubular trusses such as roof trusses,trussed,purlines, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etcs including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St 240 complete all as specified and as directed. |
| 68 | S&F Pre-painted galvalume aluminum zinc coating GI Based plain steel sheet 0.50 mm thick of any having tensile strength of 550 Mpa as in roof covering/ridges/Valleys / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 69 | S&F 0.8mm thick of plain galvanished mild steel sheeting in ridges, hips, valley gutters drip and straight flashings) length and girth as fixed with grade of zinc coating 120 complete all as specified and as directed. |
| 70 | ELECTRIFICATIONTaking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 71 | M&L concealed point wiring One light point controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, modular sheet steel sunken terminal box of appropriate size (minimum thickness of sheet not less than 0.8mm) suitable for modular switch/ fittings fixed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. complete all as specified and as directed. complete all as specified and as directed Note:- (i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. (ii) Where concealing of conduit is not feasible ie on surface of RCC roof/ceiling etc, conduit shall be fixed on surface with necessary saddles at no extra cost |
| 72 | All as per item no 71 above, but for one ceiling fan/ exhaust fan/wall fan point controlled by one, one ways switch 5/6 amps complete all as specified and as directed. |
| 73 | All as per item no 71 above, but for one socket outlet 5/6 amps point on the independent board complete all as specified and as directed. |
| 74 | All as per item no 71 above, but for one socket outlet 5/6 amps point on the same board complete all as specified and as directed. |
| 75 | All as per item No 71 above but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and as directed. |
| 76 | S&F modular switch 6 amp of one module complete all as specified and as directed. |
| 77 | S&F modular socket 6/16 amp 2/3 pin 2 module 230 volt flush type complete all as specified and as directed. |
| 78 | S&F modular socket 6 amp 2/3 pin combined 2 module 230 volt flush type complete all as specified and as directed. |
| 79 | S&F modular socket combination 6 amp 2/3 pin 2 module 230 volt flush type complete all as specified and as directed. |
| 80 | S&F modular fan regulator 120W 230 volts AC 50 Hz 2 modules complete all as specified and as directed. |
| 81 | S&F switch piano single pole flush type 5/6 amps, single pole on way complete all as specified and as directed. |
| 82 | M&L Surface point wiring One light point controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade casing capping (double lock) not less that 20mm dia and accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of 1.2mm thick MS sheet of appropriate size duly painted with aluminium paint inside and anti corrosive paint outside flush to wall with 3.0mm thick bakelite/plastic laminated sheet fixed with brass screws for housing switches, socket outlets, fan regulators etc duly earthed including fixing of boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. complete all as specified and as directed. Note:- (i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 83 | All as per item no 82 above, but for one ceiling fan/ exhaust fan/wall fan point controlled by one, one ways switch 5/6 amps complete all as specified and as directed. |
| 84 | S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed. |
| 85 | S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and complete all as specified and as directed. |
| 86 | S&F in repair IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and complete all as specified and as directed. |
| 87 | S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete all as specified and as directed. |
| 88 | S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete including removal of old unserviceable fitting complete all as specified and as directed. |
| 89 | M&L concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unserviceable aluminium submain wiring all as specified and as directed. NOTE : Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles.The cost for taking down,cutting, chases & making good as required shall deemed to be included in the quoted unit rate. |
| 90 | S&F Sheet metal enclosure for 2 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-43, IK-07 protection suitable for fixing MCB\\"S/lsolators with and complete all as specified and directed. |
| 91 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete all as specified and as directed. |
| 92 | S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, 'C' curve, 10KA all complete all as specified and as directed |
| 93 | S&F MCB, Single pole, 5 to 32 amps, 240 volts, 'C' curve, 10 KA all complete all as specified and as directed. |
| 94 | Taking down carefully Ceiling fan from its original position and refixing/hanging after repair work including painting of ceiling fan complete, at site with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc complete all as specified and as directed. |
| 95 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) pre-wired and connected with three core copper conductor from ceiling rose to connector block complete all as specified and directed |
| 96 | M&L for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 of SSR Part-I including necessary excavation and earth work, PCC 1:3:6 type C-1 with 50mm thick pre-cast RCC cover 1:2:4 type B-1 cover slab reinforced with 8 mm dia TMT bar @ 15cm C/C both ways with suitable handle of 10mm dia MS rod including providing charcoal or coke & common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore (light grade GI watering pipe wire mesh, aluminium lugs complete in all respect GI earth wire protected by 15mm bore GI pipe and other end connected with main switch/ earth test pont, including dismantling old unserviceable earth pit complete all as specified and as directed. |
| 97 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded,galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 6 sqmm 2.0 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. ( NOTE: Earthwork & Excavation, Gl pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'). |
| 98 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up/laying under ground electric cable complete all as specified and as directed. |
| 99 | Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cm as in soft/loose in depth complete all as specified and as directed. |
| 100 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 101 | M&L providing sand cushioning for protection of UG cable (8 cm deep before laying & 15 cm above the top edge of cable after laying) in trenches with dry (coarse) sand approved quality including filling, spreading and punning down to desired thickness complete all as specified & as directed. (NOTE : Punned thickness of 18 cm only shall be considered for payment purpose) |
| 102 | Supply and laying brickwork with locally (Sub Class B Bricks) available best quality bricks in trenches for protection of UG Cable with width equal to length of bricks, laid dry & flat complete all as specified & as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender