Tender For Work Of Renovation And Improvement Of The Existing Lt Distribution Network At Various Places Of Assolna Village Panchayat Areas Under The Jurisdiction Of Assolna Section Office Under S/D Ii Chinchinim, Div Xvi Margao.
Tender Overview
Project Description
Tender for Work Of Renovation And Improvement Of The Existing Lt Distribution Network At Various Places Of Assolna Village Panchayat Areas Under The Jurisdiction Of Assolna Section Office Under S/D Ii Chinchinim, Div Xvi Margao.
BOQ
| Sl. No. | Item Description |
| 1 | Supply |
| 2 | Supply of 11.00 meters long R.C.C. Pole |
| 3 | Supply of 9.0 meters long R.C.C. Pole |
| 4 | Supply of 7.5 meters long R.C.C. Pole |
| 5 | Supply of stay set for 7.5 Mtrs long RCC Pole as per technical specification |
| 6 | Supply of HDGI stay rod with plate complete for 9 mts. Long RCC pole as per technical specification |
| 7 | Supply of HDGI stay rod with plate complete for 11 mts. Long RCC pole as per technical specification |
| 8 | Supply, transportation, filling and packing by ramming of rubble of hard laterite stone under floors including watering & consolidating with earth and backfilling of poles and stays. |
| 9 | Cement Concrete1:2:4 specification |
| 10 | Supply of Enamelled danger board as per DRG No. CEE/490 |
| 11 | Supply of Anticlimbing device made out of G.I. barbed wire of size 8SWG. |
| 12 | Supply of Hot dip galvanised DP structure material consisting of the following:1)Transformer bed channel ISMC of size 100 x 50 mm, 2.74 mts long, 2 pieces alongwith transformer belting angle ISA of size 50 x 50 mm, 2740mm long, 2 pieces alongwith side supports as per Drg No. EE/IV/DP/Bed-Ch for transformer.2) GOAB switch mounting channel ISMC of size 75 x 40 mm, 2740mm mts long, 2 pieces alongwith side supports as per Drg No. EE/IV/DP/GOAB CH for each GOAB switch.3) HG fuse mounting channel ISMC of size 75 x 40 mm, 2740mm mts long, 2 pieces alongwith Lightening Arrestors mounting angles ISA of size 50 x 50 mm, 2.74 mts long alongwith side supports as per Drg No EE/IV/DP/GOAB/HG-CH for HG fuse set.4)Intake Channel ISMC for mounting Disc Insulators of size 100 x 50 mm, 1 piece as per Drg No. Drg No. EE/IV/DP/INTAKE-CH .5)The work shall include all fabrication, drilling of holes, welding, cutting etc. The hot dip galvanisation shall be done only after fabrication work is completed. |
| 13 | Supply of 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy. The AB switch shall be of current rating 200 A. The isolators shall be as per technical specification. |
| 14 | Supply of 11 KV H.G. Fuse (set of three HG fuses) units 200 Amp as specified in DRg No CEE/E-786 Revision and as per detailed technical specifications. |
| 15 | Supply of 9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60049-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm. The lightening arrestors shall be as per technical specification. |
| 16 | Supply of HDGI Stay clamps L.A for 11 mts. Long RCC pole as per DRG No. CEE/E 508 (R1) |
| 17 | Supply of HDGI S.A./L.A. cross arm clamps for 11 mts. Long RCC pole as per DRG No. EE-II/20/2008 |
| 18 | Supply of HDGI L.A./S.A. cross arm clamps suitable for 9mts RCC pole as per Drg No. CEE/E-524. |
| 19 | Supply of HDGI L.A./S.A. cross arm clamps suitable for 7.5 RCC pole as per Drg No. CEE/E-524. |
| 20 | Supply of MS Distribution Box alongwith 12nos. 200A Kit Kat fuse and MCCB of 400Amps, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlapping rain proof slit ventilators on both sides of the distribution box with wire mesh to prevent entry of insects with pin head door hinges locking arrangement and shall have required number of bus bars made out of Aluminium strips of size 40 x 10mm for connecting MCCB, fuses and cables (for 4 feeder arrangement) & other accessories. The box shall also have 'magnetic hold' arrangement to ensure that the box doors always remains in 'closed' positiion when shut even without latching. |
| 21 | Supply of Loss Level-II 100KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer as per technical specification. |
| 22 | Supply of 11 KV Disc Insulators 70 KN with H.D.G.I. Metal parts as per technical specification. |
| 23 | Supply of a) 11 KV brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date & b) Forged G. I. Pin 11 KV |
| 24 | Supply of HDGI 11 KV V-shape cross arm of Channel ISMC 75 (75x40mm) as per Drg No.CEE/E-408. |
| 25 | Supply of HDGI 11 KV cross arm made out of ISMC Channel 75X40mm as per DRG No EEIV/11KV/X-Arms for cut point & Guarding. |
| 26 | Supply of Top fitting made out of ISMC Channel 75X40mm as per DRG No EEIV/11KV/X-Arms. |
| 27 | Earthing complete with 40mm GI Pipe, 2.5 mtrs long alongwith 20 kgs each salt, Charcoal complete with brick masonary. |
| 28 | Supply of ACSR ' Weasel ' conductor of size 6/1/2.59mm. The stringing rate includes transportation, jointing, jumpering with aluminium tape etc. 3.31 Kms of the conductor shall be used for stringing of 11 KV line, 0.28Kms for providing guarding and 0.25 Kms shall be used for jumpering on DP. The remaining 0.4 Kms of conductor shall be used for earthing of transformer centre which includes crimping of lugs and terminating the conductor to all the equipments of the DP with the lugs of appropriate size. The conductor shall be as per technical specification. |
| 29 | Supply of AAC ' ANT ' conductor. |
| 30 | Supply of AAC ' GNAT ' size 7/2.21mm conductor for neutral, streetlight and jumpering as well as guarding. The conductor shall be comply to technical specification. |
| 31 | Supply of HDGI 4 pin LT cross arm channel type as per Drg. No. CEE/E/705. |
| 32 | Supply of HDGI 2 pin LT cross arm channel . |
| 33 | Supply of a) L.T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN & b) Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN. The LT Pin Insulator shall be as per technical specification. |
| 34 | Supply of a) L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN & b) G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers. The LT shackel insulator shall be as per Technical specification. |
| 35 | Supply HDGI G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part I to III 1992 as amended upto date of the size 3 ½\\" x 5/8\\" or 4\\" x 5/8\\",6\\"x5/8\\", 8\\"x5/8\\" or as per the requirement. |
| 36 | Providing of Low Tension metering to the DTC by Suplying, Installing and commissioning of following Materials:1)Epoxy resin Cast L.T. CT coil of 300/5A, Class-0.5s, 50Hz,660V, Burden 15VA conforming to IS-2705 / 1992 as amended upto date2)Electronic 3Phase,4wire ,Trivector Meter ,LT CT operated 3x240V,-/5A,50Hz, class 0.5s, Category \\"A\\" (DLMS COSEM Protocol) for DTC with RS 232 Optical port and complience to BIS ICS Doc: ETD 13(6211) and latest.3)1.1KV multistand copper conductor 2.5sq.mm, XLPE insulated, armoured control cable conforming to relevant IS amended upto date.4)Pole mounted M.S Box ( outdoor type) for Electronic Meter .5)Al. L shape flat 40mm suitable for mounting on bushing rod and brass lug |
| 37 | Supply and Fixing of CAMR Modem as per technical specification. |
| 38 | Supply of single cores, 185sq.mm, unarmoured Al conductor PVC insulated 1.1KV grade power cable as per Technical Specification and as per IS:7098 (Part-I/1988) with latest ammendment carrying ISI mark. |
| 39 | Supply of single cores, 120sq.mm, unarmoured Al conductor PVC insulated 1.1KV grade power cable as per Technical Specification and as per IS:7098 (Part-I/1988) with latest ammendment carrying ISI mark. |
| 40 | Supply of Aluminium Lugs, size 185 sq.mm as per technical specification |
| 41 | Supply of Aluminium Lugs, size 120 sq.mm |
| 42 | Supply of Aluminium Lugs, size 95 sq.mm |
| 43 | GI Tubular Fencing complete with gate and side dismantling system as peer the specifications for Distribution Transformer and Feeder pillars with concreting for GI fencing supports with plinth (0.3 x 0.3 x 0.5) cu. Mts x 12 nos Each ratio 1:3:6 and brick masonary. ( Galvanising should be hot dipped Galvanised as per IS:2629/66, minimun Zinc Coating of 1000 gms/sq.mts, 140Microns DFT, suitable for High Slainity Coastal areas) |
| 44 | HDGI Structure Materials |
| 45 | Supply of 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy. The AB switch shall be of current rating 400 A. The isolators shall be as per technical specification. |
| 46 | Cost of Erection |
| 47 | Erection of 11.00 meters long R.C.C. Pole |
| 48 | Erection of 9.0 meters long R.C.C. Pole |
| 49 | Erection of 7.5 meters long R.C.C. Pole |
| 50 | Erectionof stay set for 7.5 Mtrs long RCC Pole as per technical specification |
| 51 | Erection of HDGI stay rod with plate complete for 9 mts. Long RCC pole as per technical specification |
| 52 | Erectionof HDGI stay rod with plate complete for 11 mts. Long RCC pole as per technical specification |
| 53 | Erection of Enamelled danger board as per DRG No. CEE/490 |
| 54 | Fixing of Anticlimbing device made out of G.I. barbed wire of size 8SWG. |
| 55 | fabrication, transportation and erection of Hot dip galvanised DP structure material consisting of the following:1)Transformer bed channel ISMC of size 100 x 50 mm, 2.74 mts long, 2 pieces alongwith transformer belting angle ISA of size 50 x 50 mm, 2740mm long, 2 pieces alongwith side supports as per Drg No. EE/IV/DP/Bed-Ch for transformer.2) GOAB switch mounting channel ISMC of size 75 x 40 mm, 2740mm mts long, 2 pieces alongwith side supports as per Drg No. EE/IV/DP/GOAB CH for each GOAB switch.3) HG fuse mounting channel ISMC of size 75 x 40 mm, 2740mm mts long, 2 pieces alongwith Lightening Arrestors mounting angles ISA of size 50 x 50 mm, 2.74 mts long alongwith side supports as per Drg No EE/IV/DP/GOAB/HG-CH for HG fuse set.4)Intake Channel ISMC for mounting Disc Insulators of size 100 x 50 mm, 1 piece as per Drg No. Drg No. EE/IV/DP/INTAKE-CH .5)The work shall include all fabrication, drilling of holes, welding, cutting etc. The hot dip galvanisation shall be done only after fabrication work is completed. |
| 56 | Transportation and erection of 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy. The AB switch shall be of current rating 200 A. The isolators shall be as per technical specification. |
| 57 | fixing of 11 KV H.G. Fuse (set of three HG fuses) units 200 Amp as specified in DRg No CEE/E-786 Revision and as per detailed technical specifications. |
| 58 | fixing of 9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60049-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm. The lightening arrestors shall be as per technical specification. |
| 59 | fixing of HDGI Stay clamps L.A for 11 mts. Long RCC pole as per DRG No. CEE/E 508 (R1) |
| 60 | fixing of HDGI S.A./L.A. cross arm clamps for 11 mts. Long RCC pole as per DRG No. EE-II/20/2008 |
| 61 | Fixing of HDGI L.A./S.A. cross arm clamps suitable for 9mts RCC pole as per Drg No. CEE/E-524. |
| 62 | Fixing of HDGI L.A./S.A. cross arm clamps suitable for 7.5 RCC pole as per Drg No. CEE/E-524. |
| 63 | Erection and commissioning of MS Distribution Box alongwith 12nos. 200A Kit Kat fuse and MCCB of 400Amps, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlapping rain proof slit ventilators on both sides of the distribution box with wire mesh to prevent entry of insects with pin head door hinges locking arrangement and shall have required number of bus bars made out of Aluminium strips of size 40 x 10mm for connecting MCCB, fuses and cables (for 4 feeder arrangement) & other accessories. The box shall also have 'magnetic hold' arrangement to ensure that the box doors always remains in 'closed' positiion when shut even without latching. |
| 64 | Erection, testing and commissioning of Loss Level-II 100KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer as per technical specification. |
| 65 | Fixing of 11 KV Disc Insulators 70 KN with H.D.G.I. Metal parts as per technical specification. |
| 66 | Erection of a) 11 KV brown glazed porcelain Pin Insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date & b) Forged G. I. Pin 11 KV |
| 67 | Fixing of HDGI 11 KV V-shape cross arm of Channel ISMC 75 (75x40mm) as per Drg No.CEE/E-408. |
| 68 | Fixing of HDGI 11 KV cross arm made out of ISMC Channel 75X40mm as per DRG No EEIV/11KV/X-Arms for cut point & Guarding. |
| 69 | Supply of Top fitting made out of ISMC Channel 75X40mm as per DRG No EEIV/11KV/X-Arms. |
| 70 | Earthing complete with 40mm GI Pipe, 2.5 mtrs long alongwith 20 kgs each salt, Charcoal complete with brick masonary. |
| 71 | Stringing of ACSR ' Weasel ' conductor of size 6/1/2.59mm. The stringing rate includes transportation, jointing, jumpering with aluminium tape etc. 3.31 Kms of the conductor shall be used for stringing of 11 KV line, 0.28Kms for providing guarding and 0.25 Kms shall be used for jumpering on DP. The remaining 0.4 Kms of conductor shall be used for earthing of transformer centre which includes crimping of lugs and terminating the conductor to all the equipments of the DP with the lugs of appropriate size. The conductor shall be as per technical specification. |
| 72 | Stringing of AAC ' ANT ' conductor. |
| 73 | Stringing of AAC ' GNAT ' size 7/2.21mm conductor for neutral, streetlight and jumpering as well as guarding. The conductor shall be comply to technical specification. |
| 74 | fixing of HDGI 4 pin LT cross arm channel type as per Drg. No. CEE/E/705. |
| 75 | fixing of HDGI 2 pin LT cross arm channel . |
| 76 | Fixing of a) L.T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN & b) Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN. The LT Pin Insulator shall be as per technical specification. |
| 77 | Fixing of a) L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN & b) G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers. The LT shackel insulator shall be as per Technical specification. |
| 78 | fixing HDGI G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part I to III 1992 as amended upto date of the size 3 ½\\" x 5/8\\" or 4\\" x 5/8\\",6\\"x5/8\\", 8\\"x5/8\\" or as per the requirement. |
| 79 | Providing of Low Tension metering to the DTC by Suplying, Installing and commissioning of following Materials:1)Epoxy resin Cast L.T. CT coil of 300/5A, Class-0.5s, 50Hz,660V, Burden 15VA conforming to IS-2705 / 1992 as amended upto date2)Electronic 3Phase,4wire ,Trivector Meter ,LT CT operated 3x240V,-/5A,50Hz, class 0.5s, Category \\"A\\" (DLMS COSEM Protocol) for DTC with RS 232 Optical port and complience to BIS ICS Doc: ETD 13(6211) and latest.3)1.1KV multistand copper conductor 2.5sq.mm, XLPE insulated, armoured control cable conforming to relevant IS amended upto date.4)Pole mounted M.S Box ( outdoor type) for Electronic Meter .5)Al. L shape flat 40mm suitable for mounting on bushing rod and brass lug |
| 80 | Erection of single cores, 185sq.mm, unarmoured Al conductor PVC insulated 1.1KV grade power cable as per Technical Specification and as per IS:7098 (Part-I/1988) with latest ammendment carrying ISI mark. |
| 81 | Erection of single cores, 120sq.mm, unarmoured Al conductor PVC insulated 1.1KV grade power cable as per Technical Specification and as per IS:7098 (Part-I/1988) with latest ammendment carrying ISI mark. |
| 82 | crimping of Aluminium Lugs, size 185 sq.mm as per technical specification |
| 83 | crimping of Aluminium Lugs, size 120 sq.mm |
| 84 | crimping of Aluminium Lugs, size 95 sq.mm |
| 85 | GI Tubular Fencing complete with gate and side dismantling system as peer the specifications for Distribution Transformer and Feeder pillars with concreting for GI fencing supports with plinth (0.3 x 0.3 x 0.5) cu. Mts x 12 nos Each ratio 1:3:6 and brick masonary. ( Galvanising should be hot dipped Galvanised as per IS:2629/66, minimun Zinc Coating of 1000 gms/sq.mts, 140Microns DFT, suitable for High Slainity Coastal areas) |
| 86 | HDGI Structure Materials |
| 87 | Transportation and erection of 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy. The AB switch shall be of current rating 400 A. The isolators shall be as per technical specification. |
| 88 | Releasing and re-erection of Dist. Transformer |
| 89 | Removing and re-erection of Metering Unit suitable for Distribution Transformer. |
| 90 | Removing of the existing 7.5 m RCC pole and handing over to Sub-Divisional Engineer against acknowledgement as per technical specification. |
| 91 | Removing of the existing 9.0 m RCC pole and handing over to Sub-Divisional Engineer against acknowledgement as per technical specification. |
| 92 | Removing of the existing 11.00m RCC pole and handing over to Sub-Divisional Engineer against acknowledgement as per technical specification. |
| 93 | Removing and re-fixing of the existing service conenction single phase. |
| 94 | Removing and re-fixing of the existing service conenction three phase. |
| 95 | Removing of the existing main cable of sizes 3 and half Core 185sq.mm and handing over the same to the concerned Sub DivisionalEngineer against acknowledgment. |
| 96 | Removing of the existing feeder cable of sizes 3 and half Core 120sq.mm handing over the same to the concerned Sub divisional Engineer against acknowledgment. |
| 97 | Removing of 4 Pin cross arms assembly with Clamps, Nut & Bolt as per technical specification. |
| 98 | Removing of 2 Pin cross arms assembly with Clamps, Nut & Bolt as per technical specification. |
| 99 | Removing of LT shackle insulator and handing over to the concerned Sub-divisional Engineer against acknowledgement. |
| 100 | Removing of LT Pin Insulator and handing over to the concerned Sub-divisional Engineer against acknowledgement. |
| 101 | Removing of the existing Old deteriorated ANT conductor as per technical specification. |
| 102 | Removing of the existing Old deteriorated GNAT conductor as per technical specification. |
| 103 | Removing of old existing distibution box as per technical specification. |
| 104 | Removing of old existing GOAB switch and handing over the same to the concerned Sub-divisional Engineer against acknowledgment. |
| 105 | Removing of old exsiting HG fuse units and handing over the same to the concerned Sub-divisional Engineer against acknowledgment. |
| 106 | Removing of old existing Lightening arrestors and handing over the same to the concerned Sub-divisional Engineer against acknowledgment. |
| 107 | Removing of old existing structure materials as per technical specification. |
| 108 | Removing of old existing 11 KV disc insulators and handing over the same to the concerned Sub-divisional Engineer against acknowledgment. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender