Power Government Departments Closing in 7 days TDR #56342219

Tender For The Work Of Creation Of 33/11 Kv Gss Rural Type, 33 Kv & 11 Kv Interconnection Of Newly Proposed 33/11 Kv Gss Lakhanpur Under Aen (A-I) Lalsot As Per annual rate contract 2025 In The Jurisdiction Of Dausa Circle Of Jaipur Discom.

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
10.01 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
7 days left
EMD
20040
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for The Work Of Creation Of 33/11 Kv Gss Rural Type, 33 Kv & 11 Kv Interconnection Of Newly Proposed 33/11 Kv Gss Lakhanpur Under Aen (A-I) Lalsot As Per annual rate contract 2025 In The Jurisdiction Of Dausa Circle Of Jaipur Discom.

BOQ

Name of Work:- the work of creation of 33/11 KV GSS Rural Type, 33 KV & 11 KV Interconnection of Newly proposed 33/11 KV GSS Lakhanpur under AEN (A-I) Lalsot as per ARC 2025 in the Jurisdiction of Dausa Circle of Jaipur Discom.
Sl. No. Item Description
1Grass cutting and surface dressing including removal of unwanted/rubbish plants with roots from open ground /yard and other Nigam premises with stacking of grass/plants at desired place near the ground.
2Levelling of ground
3Levelling of ground up to 30 cm.depth. with tractor and T&P required as per condition of ground including removal of rubbish plants from ground & marking of boundary with lime powder.(Including all lead & lifting)
4Earth work excavation and foundation of platfrom of transformers and brakers including dressing of sides and ramming of bottoms .Liftup to 1.5 Meter including taking out the excavated soil and depositing and refilling of jhiri, watering and ramming and disposal of surplus excavated soil as directed with in a lead of 50 Meter.
5Hard soil mixed with boulders
6Providing and laying cement concrete including compaction etc, complete using stone aggregate 40 mm nominal size (hand broken ) in foundation plinth excluding the cost of shuttering using 1 cement:5 sand:10 aggregate mix.
7The rates are all lead of cement,lime,ballast, sand,surkhi and grit etc.at site of work.
8For all concrete work coarse sand shall be used no extra will be paid .
9Concrete mix prepared by power driven mechanical mixer shall be used .
10Under exceptional coditions, where mechanical mixer and vibrator are not used(with the approval of Engineer Incharge reduced by 3% for mechanical mixer and 2% for Vibrator
11Thickness of the cement concrete should not exceeed 100 mm.
12Plaster on new surface on walls in cement ,sand mortar 1:6 including racking of joint etc. complete fine finsh 25 mm thick.
13The rates for complete work including racking of joints,curing,grinding,mixing and finishing T&P and scaffolding material and cost of material with all lead and lift.
14The rates cover protection of all place and things,requiring protection and cleaing such places and thing of all droppings and splashes of mortar etc.
15Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
16(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
179 Mtr/ 1.2mx0.6mx1.50 m deep
18Safe carriage of PCC poles including loading / un-loading
19a) 9 Mtr. Long-400 Kg /11 Mtr. PCC pole
20Within 10 Kms.
21Above 10 Kms. & upto 30 Kms. Add for each Km.or part [email protected]/km
22c) 9 Mtr.long 200 Kg. PCC pole
23within 10 Kms.-
24Above 10 Km. & upto 30 Km. add for each Km. or part [email protected]/km
25Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
26Within 10 Kms.
27Above 10 Kms. & upto 30 Kms. Add for each Km.or part [email protected]/km
28Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.
29Within 10 Kms.
30Above 10 Kms. & upto 30 Kms. Add for each Km.or part [email protected]/km
31Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading.from store to site (these charges will be 1.5 time for both side)
32b) 25 & 40 KVA
33Within 10 Kms.
34Above 10 Kms. & upto 30 Kms Add for each Km.or part [email protected]/km
35Safe Carriage of 33/11 KV Power Transformer
36b) Above 1.6 MVA & Upto 3.15 MVA
37Within 10 Kms
38Above 10 Kms & upto 30 Kms . Add for each Km or [email protected]/km
39Above 30 Kms & upto 50 Kms . Add for each Km or [email protected]/km
40Safe loading of power/ distribution transformer.
41(A) 33/11 KV power transformer.
42Above 1.6 MVA & upto 3.15 MVA
43Safe unloading of power/distribution transformers
44a) 33/11 KV power transformer.
45Above 1.6 MVA & upto 3.15 MVA
46Safe carriage of breakers/kiosks etc. including loading/ unloading and stacking in Nigam stores
47Within 10 KMs.
48Above 10 Kms. and upto 30 Kms.Add per each km,or part [email protected]/km
49Above 30 Kms. and upto 50 Kms.Add per each km,or part [email protected]/km
50Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line.Including fixing of top bracing of M.S.Channels with pilot plates and clamps.The support is to be back filled with soil with proper ramming.The nuts &bolts are to be provided by the contractor as per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.
51PCC Poles 9 Mtr. Long(200 Kg.)
52Fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub-station.
53Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware andstrips.
54Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 2 nos.disc.& 1set of H/ W ) on terminal point including fixing of hardware and strips.
55Fixing of 33kv pin insulator with pins.
56Fixing of 11kv pin insulator with pins.
57Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
58G.O. switch . without earthing blade.
5933kv G.O.switch
6011kv G.O.switch
61Assembly and installation of Horn Gap fuse set (set of 3nos)on erected structure as per design, complete in all respectwith post insulator including jumpering on both ends for connection with the system. The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
6233kv Horn Gap fuse set.
6311kv Horn Gap fuse set.
64Installation of lightening arrestors on erected structure /support (set of 3 nos) including connection with earth by wire /strip as required and jumpering etc. The nuts & boltswill be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,
65(A)sub-station type
6633 KV L.A. set
6711 KV L.A. set
68Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of base channels as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,
6925 and 40 KVA
70Fixing of danger plates on supports/structure
71Fixing of PG clamp of Dog /Racoon Conductor
72Assembly,installation & commisioning of 11 KV Roaster switchs on erected structures with stting for accurate operation including fixing of allied accessories completed in all respect with post insulators and jumpering on both ends for connection with systm.The nuts & bolts will be supplied by contractor for which payment will be made as per prevailing Dicom store issue rates.
733 Nos of earthing of 11/0.4 KV distribution transformer /sub-station with 3 pieces of M.S.Rod 20mm dia each 3 meter long and driving them into earth by mechanical means at a distance as per approved design & drawing & specification.The work includes flattening of top ends of M.S.rod drilling a hole of 9/16\\" dia.at flattened top and tightening of M.S.flat 50x6mm/25×3mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with M.S.rods top end hole.The flat will also be welded with M.S.rod.The end will be connected to equipments as under in sequence.
74Mesh earthing for 33/11 kv sub-station as per approved map &design usingMS flat 50X6mm/MS road 20mm dia includinglaying of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints , structures & equipments etc.asunder:
75Excavation of trench of 0.65Mtrs.depth and 0.5Mtr.width
76Hard Soil
77Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.
78Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earth mesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.
79Filling of trench with available excavated muck in layers of 20cm (Max.)consolidating each deposited layer by ramming & watering with lead up to 50 Mtr, and lift up to 1.5 Mtr.
80Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.
81Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be driven in earth by mechanical means and Providing & .fastening of suitable clampswith the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil:
82Where drilling is not required
83Supply & Erection of Maintenance free Gel Earthing with Pipe in pipe / Pipe in strip technology filled with anti corrosive conductive compound ( CPRI Tested ) below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineral filling compound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone ) and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. The value of Earth resistance shall be obtained 0.5 Ohm in individual earthing. G.I Pipe (IS: 1239 marks) GI pipe 3000 mm long, 80 I 40 mm, Terminal 12 mm GI Strip. Earthing as per 18:3043-1987
84Erection of PCC poles in excavated pit in alignment after checking the same with plumb line as per approved design & drawing of 33/11kv sub-station.The pit should be back filled with the soil with proper ramming below 30cm ground level and then muffed above 15cm average ground level with cement concrete ratio1:3:6.The charges for muffing will be paid extra as per chapter code no 5.7 The nuts & bolts will be supplied by the contractor for which payment will be made at the prevailing store issue rates.
85PCC Poles 9 Mtr. Long
86Laying / stringing of bus bar with ACSR Dog & jumper connection using tie rod ,33KV /11KV insulator strings,required hardware, P.G. clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.
87ACSR DOG/RABBIT
88Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.
8911 KV VCB (Outdoor )
90Installation of current/potential transformers on supporting structure including checking of wiring & conducting all pre-commissioning tests before energization & satisfactory operation in all respect (The CT/PT set will be tested by Discom).
9133 KV CT(1 set of 3 Nos. ) OR PT Set
9211 KV CT(1 set of 3 Nos.) OR PT Set
93Installation of metering points on 11 KV Outgoing feeder at 33/11 KV S/S.
94The installation work to be carried out as per drawing/design, under the supervision of concerned Assistant Engineer
95Mounting structure
96The requisite steel members will be supplied by contractor including the hardware. Contractor shall joint/weld the members to form the mounting structure as per drawing. Necessary tools, welding, machines, lifting devices etc. shall be arranged by contractor.
97Civil works
98Erection of lattices in alignment including excavation and concreting of structure foundation including cement, sand and grit 20 mm size (crusher broken) having ratio 1:3:6 and grit 40 mm size for ratio 1:5:10 and curing for period as required (21 days). Area of concreting will be as per the drawing.
99Metering Equipments:
100The requisite metering equipments (CTPT set, meter,meter box & suitable conductors for jumpers), will be provided by the concerned Assistant Engineer in healthy condition at site. The cables from CTPT set to meter box laid down in 50 mm GI pipe with suitable bends & nipples, shall be provided by contractor alongwith the consumable items such as PVC tapes, petroleum jelly etc. The cable should be PVC multi strand copper 4 core 2.5/4 Sq. mm ISI marked and firm & tight connections shall be made by suitable connector e.g. at CTPT sets by using clamps and at meter/TTB by suitable lugs etc. The CTPT sets so installed shall be earthed by means of the MS Flat (size 50x6 mm) by joining it with the nearest earthing available at the sub-station. Requisite earthing material shall be made available by the contractor.
101Meter:
102Meters should be fixed firmly inside the tamper proof box, as per drawing. All the meter fixture will be provided by contractor including all consumables.
103Meter Box
104The meter box shall be provided by the concerned Assistant Engineer. However, hardware or any other items required to fix the meter inside the meter box will be provided by contractor. The meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block(TTB) link type shall be provided by contractor in the meter box.
105Painting:
106All surfaces interior and exterior of lattice structure shall be white aluminum painted.
107Commissioning of Metering Equipments:
108Installed meters inside the box and metering equipments duly mounted on the mounting structure will be powered up by connecting load in the presence of the concerned Assistant Engineer who will arrange the necessary shut down. The completion certificate shall be furnised by contractor.be filled accordingly. Since the work involves higher A.C. voltage level, the contractor shall take full care regarding safety norms, so as to avoid any accidental hazards.
109Fabrication of steel structures of M.S angle ,M.S.channel & M.S.Flat including cutting ,drilling and continunous welding joint as per design and drawing.
110Other steel items
111Drilling of holes in MS Channel / Angle /Flat
11215/16\\" dia holes(23.81 mm dia.)
113Trimming of tree branches/plants and preparing route approchases for proposed line.
114Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
115(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
1169 Mtr/ 1.2mx0.6mx1.50 m deep
117(B) Lattice Tower /Size of pit
11812.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
119Stay set/Depth of pit
1208'x 3/4\\" -0.75x0.5x1.6 m
121Safe carriage of PCC poles including loading / un-loading
122a) 9 Mtr. Long-400 Kg /11 Mtr. PCC pole
123Within 10 Kms.
124Above 10 Kms. & upto 30 Kms. Add for each Km.or part [email protected]/km
125Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
126Within 10 Kms.
127Above 10 Kms. & upto 30 Kms. Add for each Km.or part [email protected]/km
128Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.
129Within 10 Kms.
130Above 10 Kms. & upto 30 Kms. Add for each Km.or part [email protected]/km
131Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.
132Within 10 Kms.
133Above 10 Kms. & upto 30 Kms. Add for each Km.or part [email protected]/km
134Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.
135Lattice Structure
136Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.
137PCC Poles 9 Mtr. Long (400 Kg)/200 Kg
138Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.
139Fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.
14033 KV line
141Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware andstrips.
142Fixing of 33kv pin insulator with pins.
143Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
144G.O. switch . without earthing blade.
14533kv G.O.switch
146Fixing of danger plates on supports/structure
147Fixing of PG clamp of Dog /Racoon Conductor
148Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire /P.G.clamps . Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.
149ACSR DOG
150Providing and fixing of G.I. Pipe B-Class (IS:1239 marks) at the starting and finishing point of 33 & 11 KV under ground cables and to lay & clamp vertically with the existing support including labour charges.
151Providing and fixing of G.I. Pipe of 150 mm diameter. B-Class (IS:1239 mark),at the starting and finishing point of 33 KV under ground cables and to lay & clamp vertically with the existing support including labour charges.
152Installation of 33 KV Cable (XLPE) termination / straight through joints ( Heat shrinkable type) as per manufacturer's kit guidance and direction including preparation of cable and testing refilling etc as required.(Including crimping of lugs)
153(I) Outdoor end terminal 3x50 Sq mm to 3x185 Sq mm
154(ii) 3x240 Sq mm to 3x400 Sq mm
155Laying of 33 KV & 11KV XLPE cable without Road cutting i.e. through burrowing machine \\"VERMIER\\".(120 cm deep).Use of this technology must be restricted to the situation like:-
156(i) When the passages available for laying the proposed cable is totally a metal or cement concrete road.
157(ii) When the road cutting is not permitted by the local administration.
158A) 33 / 11 KV 3C x 300 Sq.mm cable
159For Extra Loop (Ghera) to be provided near the pole on termination point and the length ofcable along the pole for mounting of cable jointing kit.
16033 KV Cable:-
1613x240 Sq mm to 3x400 Sq mm
162Trimming of tree branches/plants and preparing route approchases for proposed line.
163Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
164(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
1659 Mtr/ 1.2mx0.6mx1.50 m deep
166(B) Lattice Tower /Size of pit
16711.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
168Stay set/Depth of pit
1696'x 5/8\\" -0.75x0.5x1.35 m
170Safe carriage of PCC poles including loading / un-loading
171c) 9 Mtr.long 200 Kg. PCC pole
172within 10 Kms.-
173Above 10 Km. & upto 30 Km. add for each Km. or part [email protected]/km
174Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
175Within 10 Kms.
176Above 10 Kms. & upto 30 Kms. Add for each Km.or part [email protected]/km
177Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.
178Within 10 Kms.
179Above 10 Kms. & upto 30 Kms. Add for each Km.or part [email protected]/km
180Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.
181Within 10 Kms.
182Above 10 Kms. & upto 30 Kms. Add for each Km.or part [email protected]/km
183Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.
184Lattice Structure
185Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam's specification for which the payment will be made at the prevailing Discom store issue rates.
186(B) IN RURAL AREA
187PCC Poles 9 Mtr. Long(200Kg.)
188Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line.Including fixing of top bracing of M.S.Channels with pilot plates and clamps.The support is to be back filled with soil with proper ramming.The nuts &bolts are to be provided by the contractor as per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.
189PCC Poles 9 Mtr. Long(200 Kg.)
190Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire
1916\\"x5/8\\" with 7/10 SWG stay wire
192Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.
193Fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.
19433 KV line
195Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 1nos.disc.& 1set of H/ W ) on terminal point including fixing of hardware and strips.
196Fixing of 11 KV pin insulator with pins.
197Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire / P.G.clamps.Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.
198IN RURAL AREA
199ACSR RABBIT
200Providing and fixing of G.I. Pipe B-Class (IS:1239 marks) at the starting and finishing point of 33 & 11 KV under ground cables and to lay & clamp vertically with the existing support including labour charges.
201Providing and fixing of G.I. Pipe of 125 mm diameter. B-Class (IS:1239 mark),at the starting and finishing point of 11 KV under ground cables and to lay & clamp vertically with the existing support including labour charges.
202Installation of cable termination / straight through joints on 11KV Aluminium conductor XLPE /PILCA Cable with outdoor/ indoor termination end and /or straight through joint including required excavation / remoral/ fixing / refixing/ testing etc. as required
203A) (I) Outdoor end terminal 3x35 Sq mm to 3x185 Sq mm
204Laying of 33 KV & 11KV XLPE cable without Road cutting i.e. through burrowing machine \\"VERMIER\\".(120 cm deep).Use of this technology must be restricted to the situation like:-
205(i) When the passages available for laying the proposed cable is totally a metal or cement concrete road.
206(ii) When the road cutting is not permitted by the local administration.
207B) 33 / 11 KV below 3C x 300 Sq.mm cable
208For Extra Loop (Ghera) to be provided near the pole on termination point and the length ofcable along the pole for mounting of cable jointing kit.
20911 KV Cable:-
2103x35 Sq mm to 3x185 Sq mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56342219
AUTHORITY Government Departments
TENDER VALUE 10.01 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Jaipur Vidyut Vitran Nigam Limited
Work Description Tender for The Work Of Creation Of 33/11 Kv Gss Rural Type, 33 Kv & 11 Kv Interconnection Of Newly Proposed 33/11 Kv Gss Lakhanpur Under Aen (A-I) Lalsot As Per annual rate contract 2025 In The Jurisdiction Of Dausa Circle Of Jaipur Discom.
Basic Detail
Tender No JPD/ZCE(JZ)/TN-199
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 07 Jul 2026
Submission Date 20 Jul 2026
Open Date 21 Jul 2026
Finance
Tender Value 10.01 Lakhs
Tender Fee 2950
EMD 20040
Exemption Not Available
Document List
531bfb68-0d62-40a5-8f23-20392fe7e4b1.html
BOQ_1020095.xls
Tendernotice_1 (27).pdf
TENDERSPECSTN199.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Jul 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

531bfb68-0d62-40a5-8f23-20392fe7e4b1.html

xls

BOQ_1020095.xls

pdf

Tendernotice_1 (27).pdf

pdf

TENDERSPECSTN199.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail