Tender For Addition Alteration Of Goc Guard Living Bathroom Of Bldg No. P-162 At Hq Cif (R) Under Age (I) Cif (R)

Issued by Statutory Bodies & Commissions/Committees · Rajouri, Jammu and Kashmir
Tender Value
9.68 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
18 days left
EMD
19360
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Addition Alteration Of Goc Guard Living Bathroom Of Bldg No. P-162 At Hq Cif (R) Under Age (I) Cif (R)

BOQ

Name of Work:- Addn/Altn of GOC Guard living Bathroom of Bldg No. P-162 at HQ CIF (R) Under AGE (I) CIF (R)
Sl. No. Item Description
1Demolition of cement concrete floors and n exc 15cm thickness (below or above ground level ) all as specified and as directed.
2M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and fair complete all as specified.
3Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified.
4M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 laying floor finishes complete all as specified.
5M&L for Non-skid coloured ceramic tiles (square/rectangular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface,complete all as specified and directed.
6M&L for 10 mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:3 and finished even and fair for receiving tiles complete all as specified.
7M&L for glazed coloured ceramic tiles in dado/vertical surface (300x450mmx 7mm) thick set and jointed in neat cement slurry and pointed in coloured cement to match the surface complete all as specified and directed.
8Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified.
9M&L for Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified. (Water proofing compound to be measured and paid for separately).
10M&L for Rendering 10mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified.
11Material and labour for 5 mm thick rendering in CM 1:3 on concrete ceiling surfaces including finishing even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
12M&L for preparation of new plastered surfaces on ceiling and applying three coats of white wash.complete all as specified and directed.
13M&L for applying two coats of cement base paint on walls after preparation of newly plastered surfaces complete all as specified.
14M&L three coats of white wash on newly plaster surfaces incl preparation of surfaces
15Roughing surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @3kg/Sqm mixed with water proofing compound including 10mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound complete all as specified and directed. (WPC shall be measured and paid separatley) Note : No extra cost shall be paid to contractor in r/o any removal of existing roof treatment.
16Material and labour for 3mm thick APP based polymeric membrane minimum weighing 3 kg/sqm non-woven polyester reinforcement polymeric water proofing membrane (wt not less than 150 gms/sqm) laid on primed surfaces by gas flame torch application and apply one coat of industrial bitumen 85/25 grade at the rate of 1.20 Kg/Sqm over APP Memberence complete all as specified and as directed by the Engineer-in-Charge.Note :- Water proofing treatment will be done by IWL or through a specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed by engaging local labour.
17Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 Square Metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt ), complete all as specified and directed by Engineer-in Charge.
18S&F solid PVC door frame of size 50mm x 47mm made out of 5mm both side Prelam PVC sheet used instead of plain colour PVC Sheet and edge will be painted to match with prelam sheet. reinforced with M.S. Square tube, in opening as per specifiecation and drawings complete all as specified and as directed.
19S&F factory made solid panel PVC door shutter 28 to 30mm thick style ,with 2,4 or 6 raised panel design with 2mm thick Moulded prelam PVC sheet on the front face & 2mm Prelam PVC sheet on back face all as specified and as directed.
20S&F Factory made mild steel ventilators box type with upper top hung with glazed and gauzed shutters and bottom openable,locking arrangements type shutters including pintol hinges,steel peg stay and one shop coat of red oxide primer complete all specified.Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3 ii) , Glazing, wire gauge and Glass shall be measured and paid for separately.
21Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks,cup Board etc and similar work conforming to Fe 290 Gd E-165 complete all as specified.
22M&L for preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of zink chrome primer complete all as specified.
23S&F 4 mm thick figured glass (frosted) ,pin head type and glazing with oil putty not exc 0.50 Sqm in each pane fixing to window/ventilator complete all as specified and as directed.
24S&F galvanised Mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
25S&F 150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
26S&F 150 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
27S&F stainless steel cold rolled butt hinges medium weight 100 mm long complete all as specified.
28Demolition of brick/stone masonry built in CM. complete all as specified.
29M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 bricks all complete all as specified.
30M&L brick work with sub class B bricks(except bricks) straight or curved on plan to any radius built in CM 1:6 bricks all complete all as specified.
31M&L Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 complete all as specified.
32M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement complete all as specified.
33S&F in repairs 600mmx450mm beveled edge mirror of selected quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified.
34Supply & Fixed as in repairs vitreous china wash basin, white, flat back, size 550x400 mm excluding taps, waste, chain and plug and porcelin stopper but including breckets , waste pipe , waste coupling ,cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed.
35S&F vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe ) but including PVC waste pipe , providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement and fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern trap and waste pipe) fixed in repair complete all as specified.
36S&F water closet (Orissa pattern) including lime concrete bedding, vitreous china long pan orissa pattern 580x440mm, white with integral foot rests (excluding flushing cistern & flush pipe) fixed in repairs complete all as specified.
37S&F 10 ltr capacity PVC valveless, syphonic action type flushing cistern low level white with inlet, ball valve, float and handle including connetion to pipe but fixed in repair complete all as specified and directed.
38Supply Only Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified.
39S&F aluminium tubular towel rail, 20mm dia, D type, 60cm long between flanges aluminium anodized, fixed with rawl plugs. complete all as specified in repairs. (ISI Mark)
40Dismantling water tanks capacity exc 500 ltrs & n'exc 1000 ltrs capacity
41S & F 1000 ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) triple layer hoisted and fixed in position all as specified in SSR Part I
42S&F in repair PVC waste Pipe 32/40mm dia and fixed complete all as specified and directed
43S&F SS grating 100mm dia fixed to floor trap in repair.
44S&F 15mm bore pillar tap cast copper alloy with capstan head chromium plated screwed down under high pressure with or without lettered hot or cold with long shank and fly nuts screwed for iron pipe.(Make Johnson /Cera or equivalent )
45S&F Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms)
46S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms)
47S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long
48S&F in repair PVC connection 15mm bore with ptmt nuts of length 450mm
49S&F in repair 15 mm bore bib taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified
50S&F fancy type chromium plated concealed stop valve cast copper alloy, screwed down, high pressure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions chromium plated of size 15 mm with long shank and cup (concealed type).
51S&F in repairs 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
52S&F in repairs 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
53S&F in repairs 20mm bore brass valve high pressure with polythene float and fly nuts complete screwed for iron pipe or brass ferrule.
54S& F Angle valves, cast copper alloy,screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair, for 15mm dia of pipe complete all as specified.
55S&F in repairs CP Soap dish as specified and directed
56S&F in repairs for Shower roses 15 mm chromium plated with or without swivel joints, any size, including 125 mm long arm and fixing to steel pipe or union, complete all as specified.
57S&F in repair Waste coupling of PTMT for 32mm dia discharge pipe (half or full threaded) (Minimum weight 32mm 45gms/ 40mm-60 gms) complete all as specified.
58Taking up or down steel tubing with connections for cleaning for refixing or removing to store yard complete all as specified of the following description :-
59(a) 15mm Bore
60(b) 20mm bore
61M & L galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
62(a) 15 mm dia
63(b) 20 mm dia
64M/L for PCC 1:5:10 TY E-2 as in Sunken floor /foundation filling and mass concrete
65M&L for 75mm thick Plain cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) finishing cement concrete surface even and smooth by using extra cement etc complete
66Chequered coloured cement concrete tiles 30 cm x 30 cm x (20-25) mm thick, machine pressed, factory made, set jointed and pointed in neat cement slurry, laid in floor with gray cement and pigment complete all as specified and directed.
67Screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
68M&L Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-1 complete all as specified.
69Excavation in trenches, n exc 1.5 m wide and n exc 1.5m in depth for foundations, etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in any type of soil
70Removing excavated material(soil) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed
71M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified.
72M & L for PCC type C 2 1:3:6 (20mm graded stone aggregate) as in surface channels and drains etc incl.necessary form works.
73Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/ stop ends etc complete all as speicified and directed by Engr-in-Charge
74Demolition and breaking up SGSW/ AC/PVC or reinforced conerete pipes set in cement mortar and taking out of trenches complete all as specified and directed.
75S&F for PVC (SWR) floor trap with dia of outlet 75mm with grating including jointing to waste pipe fixed in cement concrete PCC 1:2:4 type B-1 complete all as specified.
76S&F for PVC (SWR) floor 'P' trap with dia of outlet 100mm with including jointing to waste pipe fixed in cement concrete PCC 1:2:4 type B-1 complete all as specified.
77S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
78S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
79S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls
80S&F 75 mm PVC (SWR) bends any radius
81S& F 110 mm bore PVC SWR bends and fixed with joint sealent etc complete all specified and as directed
82S&F stack clamps out of 50mm by 5mm flat iron and 6mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof 100mm bore of pipe complete all as specified and as directed.
83S&F 110 mm PVC (SWR) junction single, (Single T) equal or unequal
84S&F 75 mm PVC (SWR) junction double, (double T), equal or unequal
85S&F for PVC (SWR) reducers
86S&F for 75 mm PVC (SWR) vent cowl
87M & L for cement concrete 1: 4 :8 type D 2 using 40 mm graded stone aggregate as in foundation filling and mass concrete etc complete all as specified and directed.
88M & L brick work with sub class 'B' bricks, straight or curved on plan exc. 6 mtr mean radius built in cement mortar 1:6 but (except bricks) complete all as specified and directed.
89Supply only integral water proofing compound complete all as specified and directed.
90Returning, filling incl spreading leveling watering and well ramming in layers not exceeding 25mm in any type of soil.
91Removing excavated material (soils) exceeding 250 m but n.exc. 500m and depositing where directed at a level not exceeding 1.5m above the starting point.
92M&L for cement concrete 1:3:6 type C1 (20mm graded aggregate) as in surface channels and drains including necessary formwork etc all as specified.
93S&F for 150 mm bore Salt-glazed stoneware drain pipes laid in trenches and jointed as specified.
94M&L for cement concrete 1:4:8 type D2 (40mm graded aggregate) in bed to 150 mm dia pipes including packing under, and haunching against the sides of pipes after they are laid and tested for complete all as specified.
95Demolition of cement concrete (reinforced) as in roof, floors (other than ground floor), beams, staircase, landing, chajjas and similar suspended work,complete all as specified.
96Providing Precast cement concrete 1:2:4 type B-1 (20mm graded aggregate ) as in manholes cover slab etc all as specified and directed by Engr-in-charge.
97M&L for TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
98Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
99M&L for point wiring for one light/fan point controlled by one switch concealed type with PVC insulated unsheathed copper cable FRLSH 1.5 sqmm multi stranded two single copper conductor in and including suitable size PVC conduit pipe complete with all accessories and with 1.5 sqmm PVC insulated copper cable FRLSH continous earth wire, re-recessed mounting pressed steel GI sheet box 2 mm thick suitable for modular switch/socket of adequate size including iner and outer white cover plate of modular complete all as specified and directed for light/Fan/exhaust/call bell points.
100All as per item No. 2 above but with 2.5 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 2.5 Sqmm PVC insulated unsheathed continuous earth wire and connecting to common earth dolly.
101Supply and fixing of modular switch single pole one way 6 Amps 1 module complete all as specified and directed
102Supply and fixing of modular switch single pole one way 16 Amps 1 module complete all as specified and directed
103Supply and fixing of modular socket 6 A/16 amp -2/3 pin combined 2 module complete all as specified and directed.
104Supply and fixing of ceiling rose 65X50 mm two to three terminals complete all as specified.
105Supply and fixing MCB DB 8 way double door SPN, 240 Volts all as specified and directed.
106Supply and fixing MCB SP 6 to 32 Amps 'B' curve, 240 Volts all as specified and directed.
107Supply and fixing MCB SPN 6 to 32 Amps 'B' curve, 240 Volts all as specified and directed.
108Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 2 core. All as per specified and directed.
109Supply and fix Exhaust Fan heavy duty, metal body complete with frame and louvers shutter, voltage 230V, 50 Hz, Copper winding of sweep 450 mm inluding making fixing arrangements including cutting of wall/surface for fixing of exhaust fan and making good the disturbed surface shall be part of job at no extra cost.
110Supply and Fixing LED light fittings 1 x 20 Watt, 220 V, AC decorative box type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of size from ceiling rose complete.
111Supply and fixing LED light fitting with high out put diffuser 2 feet, 10 watt 220 Volt, AC decorative type with driver holder and LED lampincluding connecting up with three core flexible copper conductor cable of suitable size complete
112M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4.0 mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frame 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. All as specified and directed.
113Excavation in trenches, in any type of soil not exc 1.5 mtr wide and not exc 1.5 m in depth for foundation, etc or not exceeding 10sqm on plan and not exceeding 1.5m in depth for pole, shafts, cesspits, manholes, pier holes, etc. and getting out of any type of soil for laying UG cables of various sizes complete all as specified and directed.
114Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm in any type of soil.
115Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
116Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed
117Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed.
118S&F in replacement of GI pipe light grade 40 mm complete for laying under PCC/bitumonus road or critical narrow trench, under floors and mechanical protection of UG cable.
119Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 17,070.00 during AOCNote:- Tenderers shall not quote for this Schedule Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56335278
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9.68 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Addition Alteration Of Goc Guard Living Bathroom Of Bldg No. P-162 At Hq Cif (R) Under Age (I) Cif (R)
Basic Detail
Tender No AGE(I)/R-44/2026-27
Bidding Type Tender
Location
City Rajouri
State Jammu and Kashmir
Key Dates
Publish Date 06 Jul 2026
Submission Date 27 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value 9.68 Lakhs
Tender Fee 500
EMD 19360
Exemption Available
Document List
24968285-9e8c-4769-bd18-c032cb1547a8.html
BOQ_869817.xls
TenderDocuments442627.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

24968285-9e8c-4769-bd18-c032cb1547a8.html

xls

BOQ_869817.xls

pdf

TenderDocuments442627.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender