Educational and Research Institute Statutory Bodies & Commissions/Committees Closing in 12 days TDR #56333808

Tender For Purchase Of Renewable Energy Lab Equipments For Eee Department

Issued by Statutory Bodies & Commissions/Committees · Tirunelveli, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Jul 2026
12 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tirunelveli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Purchase Of Renewable Energy Lab Equipments For Eee Department , Strain Guage Characteristics Kit - Ac Mains Power Supply:230 V +10%, 50 Hz, Metal Foil Strain Gauge Mounted On Beam/Cantilever, Strain Measurement Under Applied Load, Wheatstone Bridge Arrangement, Signal Conditioning And Amplification Circuit, Instrumentation Amplifiers With 3 ½ Digit Display For Strain/Output Voltage ,Zero And Gain Adjustment Controls, Provision For Applying Calibrated Loads, Table-Top Trainer With Labelled Panel, Test Points For Signal Measurement, Built-In Dc Power Supplies And Wooden Closed Cabinet, Supplied With Patch Chords , Load Cell Characteristics Kit Input Supply :230 V /50 Hz Ac With Regulated Internal Dc Supply, Sensor: Strain Gauge Load Cell With Suitable Mounting Arrangement , Load Range: 0-10Kg , Display: Digital Display For Load/Output Indication, Cro/Test Points: Test Points Provided For Observing Bridge Output, Amplifier Output, And Signal Conditioning Stages, Controls: Zero Adjustment And Calibration Controls Provided, Protection: Overload And Short -Circuit Protection Provided ,Accessories: Loading Arrangement, Connecting Leads , Measurement Of Tank Level Using Rotometer Input Supply: 230 V/50 Hz With Regulated Internal Dc Supply ,Tank Arrangements: Transparent Tank With 30 Liters Capacity With Suitable Supporting Stand, Rotameter Range: 0-4000 L/ Hr Calibrated Rotameter, Flow System: Pump, Control Valves, And Piping Arrangements Provided For Continuous Flow Operation ,Measurement Facility: Provision For Flow -Based Tank Level Measurement And Observation ,Display/Observation: Calibrated Level Indication With Flow Monitoring Arrangement, Test Points: Output Terminals Provided For Monitoring Sensor /Output Signals , Accessories: Connecting Tubes , Measurement Of Temperature Using Pt 100: Input Supply : 230 V/50Hz Ac With Regulated Internal Dc Power Supply Unit , Sensor: Pt 100 Resistance Temperature Detector (Rtd) Probe With Stainless Steel Sheath, Measurement Principle: Resistance Variation Of Platinum Element With Temperature, Temperature Range : 0 Oc To 150Oc (Or Suitable Laboratory Range ),Display Unit: Digital Temperature Indicator With Direct Oc Display, Accuracy: High Accuracy With Linearized Rtd Signal Conditioning Circuit, Signal Conditioning: Built -In Bridge Circuit With Amplifier And Linearization ,Test Points: Provided For Rtd Input, Bridge Output, Amplifier Output, And Final Display Signal, Controls: Zero And Span Calibration Adjustment For Temperature Calibration , Protection: Over-Voltage And Short Circuit Protection For Electronic Modules , Accessories: Temperature Bath Or Heater Arrangement, Connecting Cables, User Manual, And Circuit Diagram Included. , Temperature Measurement Trainer With Pt 100, Ntc, Tc: Input Supply: 230 V/50Hz Ac With Regulated Internal Dc Power Supply Unit, Sensors Provided: Pt 100 Rtd,Ntc Thermistor, And Thermocouple(Tc-K Type), Measurement Principle: Resistance Variation (Ptc &Ntc) And See Back Effect (Thermocouple), Temperature Range: Suitable For Laboratory Range (0Oc To 150Oc Or Higher Depending On Sensor), Display Unit: Digital Temperature Indicator With Selector Switch For Pt 100/Ntc/Tc, Signal Conditioning: Separate Condition Circuits For Rtd Bridge, Thermistor Network, And Thermocouple Amplifier, Test Points: Provided For Sensor Input ,Conditioned Output, And Final Display Signal, Controls: Sensor Selection Switch, Zero/ Span Calibration , And Temperature Adjustment Control, Protection : Over- Voltage And Short Circuit Protection For Electronic Modules , Accessories: Heating Source Or Temperature Bath Connecting Leads , Bourdon Tube Pressure Gauge: Analog Indicating Type , Measurement Ranges: 0 To 10 Bar , Dial Size: 100Mm Nominal Dial Diameter, Accuracy: + 1.6% Of Full Scale(Fs),Pressure Element: Bourdon Tube Made Of Phosphor Bronze/Stainless Steel-Case Material: Mild Steel Powder Coated /Ss304 Stainless Steel, Window Material: Clear Acrylic/Glass, Connection Type: Bottom Entry/Back Entry,1/2 Bsp Threaded Connection(Or1/4 Bsp As Required), Mounting: Panel Mounting / Direct Mounting , Scale: Dual Scale: Bar, Psi, Pointer: Micrometre Adjustable Aluminium Pointer, Operating Temperature: Ambient: -10°C To +65°C, Process Fluid Temperature: Up To 80°C , Protection Class: Ip54 Minimum , Over Pressure Limit: 130% Of Full Scale Value , Calibration: Factory Calibrated With Calibration Certificate , Differential Pressure Transmitter : Input Supply: 230 V / 50 Hz Ac With Regulated Internal Dc Power Supply Unit, Tank Arrangement: Transparent Tank With Mounting Stand For Real-Time Liquid Level Observation, Tank Capacity: Laboratory-Scale Transparent Tank With Capacity 30 Litres Suitable For 0-100% Level Measurement, Differential Pressure Range: 0-100 Mbar To 0-10 Bar. Accessories: Complete Piping, Control Valves And Pump System For Continuous Water Circulation And Level Variation, Display Unit: Digital Indicator For Real-Time Level Measurement And Monitoring, Output Signal: 4-20 Ma Dc, Two-Wire System, Accuracy: ±0.1% Of Full Scale, Test Points: Provided For Dp Input Ports, Transmitter Output, And Signal Verification., Controls: Zero And Span Calibration Adjustment For Accurate Level Setting, Process Connection: 1/4 Npt / 1/2 Bsp Female Adaptor, Wetted Parts Material: Ss316 Stainless Steel, Enclosure Protection: Ip65 / Ip67, Communication: Hart Protocol Compatible, Operating Temperature: -20°C To +70°C. • Mounting: Wall/Pipe Mounting With Bracket, Protection: Over-Voltage And Short-Circuit Protection For Electronic And Electrical Modules, Over Pressure Protection: 150% Of Rated Pressure. , Solenoid Valve Kit : Type: Electrically Operated Solenoid Valve Trainer / Kit. ,Valve Type: 2/2 Way And 3/2 Way Normally Closed (Nc) Solenoid Valves, Operating Voltage: 12 V Dc / 24 V Dc / 230 V Ac, Port Size: 1/4 Bsp Threaded Connection. ,Body Material: Brass / Stainless Steel, Seal Material: Nitrile (Nbr) / Viton, Operating Pressure: 0-10 Bar, Flow Media: Air, Water, And Non-Corrosive Fluids, Coil Insulation Class: Class F Or Better, Protection Class: Ip65 Minimum, Response Time: Fast Switching Operation, Mounting: Panel/Base Mounting Arrangement, Indicators: Led Indication For Valve On/Off Status. Accessories: Connecting Tubes, Fittings, Power Cord, And Control Switches. , Calorimeter: Vessel Material: Copper / Aluminium Calorimeter Vessel, Capacity: 250 Ml / 500 Ml Minimum, Insulation: Double-Walled Insulated Outer Container, Stirrer: Non-Corrosive Stirrer Provided, Thermometer Provision: Suitable Slot For Thermometer/Temperature Sensor, Lid Arrangement: Insulated Lid With Openings For Stirrer And Thermometer, Temperature Range: Ambient To 100°C, Least Count Compatibility: Suitable For 0.1°C Thermometer, Heating Arrangement: Compatible With External Heater / Immersion Heater, Mounting: Table-Top Laboratory Model, Accessories: Stirrer, Lid, Thermometer, Measuring Cup, And Connecting Accessories. , Solar Water Heater Performance Test Setup : Collector Type: Flat Plate Collector / Evacuated Tube Collector, Collector Area: 1 M² To 2 M² Minimum, Storage Tank Capacity: 50 Litres To 100 Litres, Tank Material: Stainless Steel Insulated Storage Tank, Absorber Material: Copper/Aluminium Absorber Plate With Selective Coating, Glazing Material: Toughened Glass Cover, Insulation: Mineral Wool / Puf Insulation Provided, Circulation Type: Natural Circulation / Forced Circulation System, Temperature Measurement: Digital Temperature Indicators At Inlet And Outlet, Flow Measurement: Rotameter / Flow Meter Provided, Pressure Measurement: Bourdon Pressure Gauge Provided. Heating Backup: Electrical Heater Backup Provision, Mounting Frame: Corrosion-Resistant Inclined Mounting Structure, Data Acquisition: Provision For Performance Analysis And Efficiency Calculation, Power Supply: 230 V Ac For Instrumentation And Heater Backup, Accessories: Connecting Pipes, Valves, Sensors, Control Panel And Experiment Manual

BOQ

Name of Work:- PURCHASE OF RENEWABLE ENERGY LAB EQUIPMENTS FOR EEE DEPARTMENT
Sl. No. Item Description
1STRAIN GUAGE CHARACTERISTICS KIT – AC mains power supply:230 V +10%, 50 Hz, Metal foil strain gauge mounted on beam/cantilever, Strain measurement under applied load, Wheatstone bridge arrangement, Signal Conditioning and amplification circuit, Instrumentation amplifiers with 3 ½ digit display for strain/output voltage ,Zero and gain adjustment controls, Provision for applying calibrated loads, Table-top trainer with labelled panel, Test points for signal measurement, Built-in DC power supplies and wooden closed cabinet, Supplied with patch chords
2LOAD CELL CHARACTERISTICS KITInput supply :230 v /50 Hz ac with regulated internal DC supply, Sensor: strain gauge load cell with suitable mounting arrangement ,Load range: 0-10Kg ,Display: digital display for load/output indication, CRO/test points: Test points provided for observing bridge output, amplifier output, and signal conditioning stages, Controls: Zero adjustment and calibration controls provided, Protection: Overload and short -circuit protection provided ,Accessories: Loading arrangement, connecting leads
3MEASUREMENT OF TANK LEVEL USING ROTOMETERInput supply: 230 v/50 Hz with regulated internal DC supply ,Tank Arrangements: Transparent tank with 30 liters capacity with suitable supporting stand, Rotameter range: 0-4000 L/ hr calibrated rotameter, Flow system: pump, control valves, and piping arrangements provided for continuous flow operation ,Measurement facility: provision for flow -based tank level measurement and observation ,Display/observation: calibrated level indication with flow monitoring arrangement, Test points: output terminals provided for monitoring sensor /output signals , Accessories: connecting tubes
4MEASUREMENT OF TEMPERATURE USING PT 100:Input supply : 230 v/50Hz ac with regulated internal DC power supply unit , Sensor: PT 100 resistance temperature Detector (RTD) probe with stainless steel sheath, Measurement principle: Resistance variation of platinum element with temperature, Temperature Range : 0 OC to 150OC (or suitable laboratory range ),Display unit: Digital temperature indicator with direct OC display, Accuracy: High accuracy with linearized RTD signal conditioning circuit, Signal conditioning: Built -in bridge circuit with amplifier and linearization ,Test points: Provided for RTD input, bridge output, amplifier output, and final display signal, Controls: Zero and span calibration adjustment for temperature calibration , protection: Over-voltage and short circuit protection for electronic modules , Accessories: Temperature bath or heater arrangement, connecting cables, user manual, and circuit diagram included.
5TEMPERATURE MEASUREMENT TRAINER WITH PT 100, NTC, TC:Input supply: 230 v/50Hz ac with regulated internal DC power supply unit, sensors provided: PT 100 RTD,NTC thermistor, and thermocouple(TC-K type), Measurement principle: Resistance variation (PTC &NTC) and see back effect (thermocouple), Temperature Range: suitable for laboratory range (0OC to 150OC or higher depending on sensor), Display unit: Digital temperature indicator with selector switch for PT 100/NTC/TC, Signal conditioning: separate condition circuits for RTD bridge, thermistor network, and thermocouple amplifier, Test points: provided for sensor input ,conditioned output, and final display signal, Controls: sensor selection switch, zero/ span calibration , and temperature adjustment control, Protection : over- voltage and short circuit protection for electronic modules , Accessories: Heating source or temperature bath connecting leads
6Bourdon tube pressure gauge: Analog indicating type , Measurement Ranges: 0 to 10 bar , Dial size: 100mm nominal dial diameter, Accuracy: + 1.6% of full scale(FS),Pressure element: bourdon tube made of phosphor bronze/stainless steel-case material: mild steel powder coated /SS304 stainless steel, window material: clear acrylic/glass, connection type: bottom entry/back entry,1/2\\" BSP threaded connection(or1/4\\" BSP as required), Mounting: Panel mounting / direct mounting , Scale: Dual scale: bar, psi, Pointer: Micrometre adjustable aluminium pointer, Operating Temperature: Ambient: –10°C to +65°C, Process fluid temperature: up to 80°C , Protection Class: IP54 minimum , Over Pressure Limit: 130% of full scale value , Calibration: Factory calibrated with calibration certificate
7Differential Pressure Transmitter : Input Supply: 230 V / 50 Hz ac with regulated internal DC power supply unit, Tank Arrangement: Transparent tank with mounting stand for real-time liquid level observation, Tank Capacity: Laboratory-scale transparent tank with capacity 30 litres suitable for 0–100% level measurement, Differential pressure range: 0–100 mbar to 0–10 bar. Accessories: Complete piping, control valves and pump system for continuous water circulation and level variation, Display Unit: Digital indicator for real-time level measurement and monitoring, Output signal: 4–20 mA DC, two-wire system, Accuracy: ±0.1% of full scale, Test Points: Provided for DP input ports, transmitter output, and signal verification., Controls: Zero and span calibration adjustment for accurate level setting, Process connection: 1/4\\" NPT / 1/2\\" BSP female adaptor, Wetted parts material: SS316 stainless steel, Enclosure protection: IP65 / IP67, Communication: HART protocol compatible, Operating temperature: –20°C to +70°C. • Mounting: Wall/pipe mounting with bracket, Protection: Over-voltage and short-circuit protection for electronic and electrical modules, Over pressure protection: 150% of rated pressure.
8Solenoid Valve Kit : Type: Electrically operated solenoid valve trainer / kit. ,Valve type: 2/2 way and 3/2 way normally closed (NC) solenoid valves, Operating voltage: 12 V DC / 24 V DC / 230 V AC, Port size: 1/4\\" BSP threaded connection. ,Body material: Brass / stainless steel, Seal material: Nitrile (NBR) / Viton, Operating pressure: 0–10 bar, Flow media: Air, water, and non-corrosive fluids, Coil insulation class: Class F or better, Protection class: IP65 minimum, Response time: Fast switching operation, Mounting: Panel/base mounting arrangement, Indicators: LED indication for valve ON/OFF status. Accessories: Connecting tubes, fittings, power cord, and control switches.
9CALORIMETER: Vessel material: Copper / aluminium calorimeter vessel, Capacity: 250 ml / 500 ml minimum, Insulation: Double-walled insulated outer container, Stirrer: Non-corrosive stirrer provided, Thermometer provision: Suitable slot for thermometer/temperature sensor, Lid arrangement: Insulated lid with openings for stirrer and thermometer, Temperature range: Ambient to 100°C, Least count compatibility: Suitable for 0.1°C thermometer, Heating arrangement: Compatible with external heater / immersion heater, Mounting: Table-top laboratory model, Accessories: Stirrer, lid, thermometer, measuring cup, and connecting accessories.
10SOLAR WATER HEATER PERFORMANCE TEST SETUP : Collector type: Flat plate collector / evacuated tube collector, Collector area: 1 m² to 2 m² minimum, Storage tank capacity: 50 litres to 100 litres, Tank material: Stainless steel insulated storage tank, Absorber material: Copper/aluminium absorber plate with selective coating, Glazing material: Toughened glass cover, Insulation: Mineral wool / PUF insulation provided, Circulation type: Natural circulation / forced circulation system, Temperature measurement: Digital temperature indicators at inlet and outlet, Flow measurement: Rotameter / flow meter provided, Pressure measurement: Bourdon pressure gauge provided. Heating backup: Electrical heater backup provision, Mounting frame: Corrosion-resistant inclined mounting structure, Data acquisition: Provision for performance analysis and efficiency calculation, Power supply: 230 V AC for instrumentation and heater backup, Accessories: Connecting pipes, valves, sensors, control panel and experiment manual Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56333808
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 20-07-2026
Authority
Authority Name Directorate Of Technical Education
Work Description Tender for Purchase Of Renewable Energy Lab Equipments For Eee Department , Strain Guage Characteristics Kit - Ac Mains Power Supply:230 V +10%, 50 Hz, Metal Foil Strain Gauge Mounted On Beam/Cantilever, Strain Measurement Under Applied Load, Wheatstone Bridge Arrangement, Signal Conditioning And Amplification Circuit, Instrumentation Amplifiers With 3 ½ Digit Display For Strain/Output Voltage ,Zero And Gain Adjustment Controls, Provision For Applying Calibrated Loads, Table-Top Trainer With Labelled Panel, Test Points For Signal Measurement, Built-In Dc Power Supplies And Wooden Closed Cabinet, Supplied With Patch Chords , Load Cell Characteristics Kit Input Supply :230 V /50 Hz Ac With Regulated Internal Dc Supply, Sensor: Strain Gauge Load Cell With Suitable Mounting Arrangement , Load Range: 0-10Kg , Display: Digital Display For Load/Output Indication, Cro/Test Points: Test Points Provided For Observing Bridge Output, Amplifier Output, And Signal Conditioning Stages, Controls: Zero Adjustment And Calibration Controls Provided, Protection: Overload And Short -Circuit Protection Provided ,Accessories: Loading Arrangement, Connecting Leads , Measurement Of Tank Level Using Rotometer Input Supply: 230 V/50 Hz With Regulated Internal Dc Supply ,Tank Arrangements: Transparent Tank With 30 Liters Capacity With Suitable Supporting Stand, Rotameter Range: 0-4000 L/ Hr Calibrated Rotameter, Flow System: Pump, Control Valves, And Piping Arrangements Provided For Continuous Flow Operation ,Measurement Facility: Provision For Flow -Based Tank Level Measurement And Observation ,Display/Observation: Calibrated Level Indication With Flow Monitoring Arrangement, Test Points: Output Terminals Provided For Monitoring Sensor /Output Signals , Accessories: Connecting Tubes , Measurement Of Temperature Using Pt 100: Input Supply : 230 V/50Hz Ac With Regulated Internal Dc Power Supply Unit , Sensor: Pt 100 Resistance Temperature Detector (Rtd) Probe With Stainless Steel Sheath, Measurement Principle: Resistance Variation Of Platinum Element With Temperature, Temperature Range : 0 Oc To 150Oc (Or Suitable Laboratory Range ),Display Unit: Digital Temperature Indicator With Direct Oc Display, Accuracy: High Accuracy With Linearized Rtd Signal Conditioning Circuit, Signal Conditioning: Built -In Bridge Circuit With Amplifier And Linearization ,Test Points: Provided For Rtd Input, Bridge Output, Amplifier Output, And Final Display Signal, Controls: Zero And Span Calibration Adjustment For Temperature Calibration , Protection: Over-Voltage And Short Circuit Protection For Electronic Modules , Accessories: Temperature Bath Or Heater Arrangement, Connecting Cables, User Manual, And Circuit Diagram Included. , Temperature Measurement Trainer With Pt 100, Ntc, Tc: Input Supply: 230 V/50Hz Ac With Regulated Internal Dc Power Supply Unit, Sensors Provided: Pt 100 Rtd,Ntc Thermistor, And Thermocouple(Tc-K Type), Measurement Principle: Resistance Variation (Ptc &Ntc) And See Back Effect (Thermocouple), Temperature Range: Suitable For Laboratory Range (0Oc To 150Oc Or Higher Depending On Sensor), Display Unit: Digital Temperature Indicator With Selector Switch For Pt 100/Ntc/Tc, Signal Conditioning: Separate Condition Circuits For Rtd Bridge, Thermistor Network, And Thermocouple Amplifier, Test Points: Provided For Sensor Input ,Conditioned Output, And Final Display Signal, Controls: Sensor Selection Switch, Zero/ Span Calibration , And Temperature Adjustment Control, Protection : Over- Voltage And Short Circuit Protection For Electronic Modules , Accessories: Heating Source Or Temperature Bath Connecting Leads , Bourdon Tube Pressure Gauge: Analog Indicating Type , Measurement Ranges: 0 To 10 Bar , Dial Size: 100Mm Nominal Dial Diameter, Accuracy: + 1.6% Of Full Scale(Fs),Pressure Element: Bourdon Tube Made Of Phosphor Bronze/Stainless Steel-Case Material: Mild Steel Powder Coated /Ss304 Stainless Steel, Window Material: Clear Acrylic/Glass, Connection Type: Bottom Entry/Back Entry,1/2 Bsp Threaded Connection(Or1/4 Bsp As Required), Mounting: Panel Mounting / Direct Mounting , Scale: Dual Scale: Bar, Psi, Pointer: Micrometre Adjustable Aluminium Pointer, Operating Temperature: Ambient: -10°C To +65°C, Process Fluid Temperature: Up To 80°C , Protection Class: Ip54 Minimum , Over Pressure Limit: 130% Of Full Scale Value , Calibration: Factory Calibrated With Calibration Certificate , Differential Pressure Transmitter : Input Supply: 230 V / 50 Hz Ac With Regulated Internal Dc Power Supply Unit, Tank Arrangement: Transparent Tank With Mounting Stand For Real-Time Liquid Level Observation, Tank Capacity: Laboratory-Scale Transparent Tank With Capacity 30 Litres Suitable For 0-100% Level Measurement, Differential Pressure Range: 0-100 Mbar To 0-10 Bar. Accessories: Complete Piping, Control Valves And Pump System For Continuous Water Circulation And Level Variation, Display Unit: Digital Indicator For Real-Time Level Measurement And Monitoring, Output Signal: 4-20 Ma Dc, Two-Wire System, Accuracy: ±0.1% Of Full Scale, Test Points: Provided For Dp Input Ports, Transmitter Output, And Signal Verification., Controls: Zero And Span Calibration Adjustment For Accurate Level Setting, Process Connection: 1/4 Npt / 1/2 Bsp Female Adaptor, Wetted Parts Material: Ss316 Stainless Steel, Enclosure Protection: Ip65 / Ip67, Communication: Hart Protocol Compatible, Operating Temperature: -20°C To +70°C. • Mounting: Wall/Pipe Mounting With Bracket, Protection: Over-Voltage And Short-Circuit Protection For Electronic And Electrical Modules, Over Pressure Protection: 150% Of Rated Pressure. , Solenoid Valve Kit : Type: Electrically Operated Solenoid Valve Trainer / Kit. ,Valve Type: 2/2 Way And 3/2 Way Normally Closed (Nc) Solenoid Valves, Operating Voltage: 12 V Dc / 24 V Dc / 230 V Ac, Port Size: 1/4 Bsp Threaded Connection. ,Body Material: Brass / Stainless Steel, Seal Material: Nitrile (Nbr) / Viton, Operating Pressure: 0-10 Bar, Flow Media: Air, Water, And Non-Corrosive Fluids, Coil Insulation Class: Class F Or Better, Protection Class: Ip65 Minimum, Response Time: Fast Switching Operation, Mounting: Panel/Base Mounting Arrangement, Indicators: Led Indication For Valve On/Off Status. Accessories: Connecting Tubes, Fittings, Power Cord, And Control Switches. , Calorimeter: Vessel Material: Copper / Aluminium Calorimeter Vessel, Capacity: 250 Ml / 500 Ml Minimum, Insulation: Double-Walled Insulated Outer Container, Stirrer: Non-Corrosive Stirrer Provided, Thermometer Provision: Suitable Slot For Thermometer/Temperature Sensor, Lid Arrangement: Insulated Lid With Openings For Stirrer And Thermometer, Temperature Range: Ambient To 100°C, Least Count Compatibility: Suitable For 0.1°C Thermometer, Heating Arrangement: Compatible With External Heater / Immersion Heater, Mounting: Table-Top Laboratory Model, Accessories: Stirrer, Lid, Thermometer, Measuring Cup, And Connecting Accessories. , Solar Water Heater Performance Test Setup : Collector Type: Flat Plate Collector / Evacuated Tube Collector, Collector Area: 1 M² To 2 M² Minimum, Storage Tank Capacity: 50 Litres To 100 Litres, Tank Material: Stainless Steel Insulated Storage Tank, Absorber Material: Copper/Aluminium Absorber Plate With Selective Coating, Glazing Material: Toughened Glass Cover, Insulation: Mineral Wool / Puf Insulation Provided, Circulation Type: Natural Circulation / Forced Circulation System, Temperature Measurement: Digital Temperature Indicators At Inlet And Outlet, Flow Measurement: Rotameter / Flow Meter Provided, Pressure Measurement: Bourdon Pressure Gauge Provided. Heating Backup: Electrical Heater Backup Provision, Mounting Frame: Corrosion-Resistant Inclined Mounting Structure, Data Acquisition: Provision For Performance Analysis And Efficiency Calculation, Power Supply: 230 V Ac For Instrumentation And Heater Backup, Accessories: Connecting Pipes, Valves, Sensors, Control Panel And Experiment Manual
Basic Detail
Tender No 9/A3/2026
Bidding Type Tender
Location
City Tirunelveli
State Tamil Nadu
Key Dates
Publish Date 06 Jul 2026
Submission Date 20 Jul 2026
Open Date 21 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
BOQ_822440.xls
d2ea2086-4f14-4bb0-a57a-ab0b8e6b5a61.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Jul 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_822440.xls

html

d2ea2086-4f14-4bb0-a57a-ab0b8e6b5a61.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders