Tender For Purchase Of Renewable Energy Lab Equipments For Eee Department
Tender Overview
Project Description
Tender for Purchase Of Renewable Energy Lab Equipments For Eee Department , Strain Guage Characteristics Kit - Ac Mains Power Supply:230 V +10%, 50 Hz, Metal Foil Strain Gauge Mounted On Beam/Cantilever, Strain Measurement Under Applied Load, Wheatstone Bridge Arrangement, Signal Conditioning And Amplification Circuit, Instrumentation Amplifiers With 3 ½ Digit Display For Strain/Output Voltage ,Zero And Gain Adjustment Controls, Provision For Applying Calibrated Loads, Table-Top Trainer With Labelled Panel, Test Points For Signal Measurement, Built-In Dc Power Supplies And Wooden Closed Cabinet, Supplied With Patch Chords , Load Cell Characteristics Kit Input Supply :230 V /50 Hz Ac With Regulated Internal Dc Supply, Sensor: Strain Gauge Load Cell With Suitable Mounting Arrangement , Load Range: 0-10Kg , Display: Digital Display For Load/Output Indication, Cro/Test Points: Test Points Provided For Observing Bridge Output, Amplifier Output, And Signal Conditioning Stages, Controls: Zero Adjustment And Calibration Controls Provided, Protection: Overload And Short -Circuit Protection Provided ,Accessories: Loading Arrangement, Connecting Leads , Measurement Of Tank Level Using Rotometer Input Supply: 230 V/50 Hz With Regulated Internal Dc Supply ,Tank Arrangements: Transparent Tank With 30 Liters Capacity With Suitable Supporting Stand, Rotameter Range: 0-4000 L/ Hr Calibrated Rotameter, Flow System: Pump, Control Valves, And Piping Arrangements Provided For Continuous Flow Operation ,Measurement Facility: Provision For Flow -Based Tank Level Measurement And Observation ,Display/Observation: Calibrated Level Indication With Flow Monitoring Arrangement, Test Points: Output Terminals Provided For Monitoring Sensor /Output Signals , Accessories: Connecting Tubes , Measurement Of Temperature Using Pt 100: Input Supply : 230 V/50Hz Ac With Regulated Internal Dc Power Supply Unit , Sensor: Pt 100 Resistance Temperature Detector (Rtd) Probe With Stainless Steel Sheath, Measurement Principle: Resistance Variation Of Platinum Element With Temperature, Temperature Range : 0 Oc To 150Oc (Or Suitable Laboratory Range ),Display Unit: Digital Temperature Indicator With Direct Oc Display, Accuracy: High Accuracy With Linearized Rtd Signal Conditioning Circuit, Signal Conditioning: Built -In Bridge Circuit With Amplifier And Linearization ,Test Points: Provided For Rtd Input, Bridge Output, Amplifier Output, And Final Display Signal, Controls: Zero And Span Calibration Adjustment For Temperature Calibration , Protection: Over-Voltage And Short Circuit Protection For Electronic Modules , Accessories: Temperature Bath Or Heater Arrangement, Connecting Cables, User Manual, And Circuit Diagram Included. , Temperature Measurement Trainer With Pt 100, Ntc, Tc: Input Supply: 230 V/50Hz Ac With Regulated Internal Dc Power Supply Unit, Sensors Provided: Pt 100 Rtd,Ntc Thermistor, And Thermocouple(Tc-K Type), Measurement Principle: Resistance Variation (Ptc &Ntc) And See Back Effect (Thermocouple), Temperature Range: Suitable For Laboratory Range (0Oc To 150Oc Or Higher Depending On Sensor), Display Unit: Digital Temperature Indicator With Selector Switch For Pt 100/Ntc/Tc, Signal Conditioning: Separate Condition Circuits For Rtd Bridge, Thermistor Network, And Thermocouple Amplifier, Test Points: Provided For Sensor Input ,Conditioned Output, And Final Display Signal, Controls: Sensor Selection Switch, Zero/ Span Calibration , And Temperature Adjustment Control, Protection : Over- Voltage And Short Circuit Protection For Electronic Modules , Accessories: Heating Source Or Temperature Bath Connecting Leads , Bourdon Tube Pressure Gauge: Analog Indicating Type , Measurement Ranges: 0 To 10 Bar , Dial Size: 100Mm Nominal Dial Diameter, Accuracy: + 1.6% Of Full Scale(Fs),Pressure Element: Bourdon Tube Made Of Phosphor Bronze/Stainless Steel-Case Material: Mild Steel Powder Coated /Ss304 Stainless Steel, Window Material: Clear Acrylic/Glass, Connection Type: Bottom Entry/Back Entry,1/2 Bsp Threaded Connection(Or1/4 Bsp As Required), Mounting: Panel Mounting / Direct Mounting , Scale: Dual Scale: Bar, Psi, Pointer: Micrometre Adjustable Aluminium Pointer, Operating Temperature: Ambient: -10°C To +65°C, Process Fluid Temperature: Up To 80°C , Protection Class: Ip54 Minimum , Over Pressure Limit: 130% Of Full Scale Value , Calibration: Factory Calibrated With Calibration Certificate , Differential Pressure Transmitter : Input Supply: 230 V / 50 Hz Ac With Regulated Internal Dc Power Supply Unit, Tank Arrangement: Transparent Tank With Mounting Stand For Real-Time Liquid Level Observation, Tank Capacity: Laboratory-Scale Transparent Tank With Capacity 30 Litres Suitable For 0-100% Level Measurement, Differential Pressure Range: 0-100 Mbar To 0-10 Bar. Accessories: Complete Piping, Control Valves And Pump System For Continuous Water Circulation And Level Variation, Display Unit: Digital Indicator For Real-Time Level Measurement And Monitoring, Output Signal: 4-20 Ma Dc, Two-Wire System, Accuracy: ±0.1% Of Full Scale, Test Points: Provided For Dp Input Ports, Transmitter Output, And Signal Verification., Controls: Zero And Span Calibration Adjustment For Accurate Level Setting, Process Connection: 1/4 Npt / 1/2 Bsp Female Adaptor, Wetted Parts Material: Ss316 Stainless Steel, Enclosure Protection: Ip65 / Ip67, Communication: Hart Protocol Compatible, Operating Temperature: -20°C To +70°C. • Mounting: Wall/Pipe Mounting With Bracket, Protection: Over-Voltage And Short-Circuit Protection For Electronic And Electrical Modules, Over Pressure Protection: 150% Of Rated Pressure. , Solenoid Valve Kit : Type: Electrically Operated Solenoid Valve Trainer / Kit. ,Valve Type: 2/2 Way And 3/2 Way Normally Closed (Nc) Solenoid Valves, Operating Voltage: 12 V Dc / 24 V Dc / 230 V Ac, Port Size: 1/4 Bsp Threaded Connection. ,Body Material: Brass / Stainless Steel, Seal Material: Nitrile (Nbr) / Viton, Operating Pressure: 0-10 Bar, Flow Media: Air, Water, And Non-Corrosive Fluids, Coil Insulation Class: Class F Or Better, Protection Class: Ip65 Minimum, Response Time: Fast Switching Operation, Mounting: Panel/Base Mounting Arrangement, Indicators: Led Indication For Valve On/Off Status. Accessories: Connecting Tubes, Fittings, Power Cord, And Control Switches. , Calorimeter: Vessel Material: Copper / Aluminium Calorimeter Vessel, Capacity: 250 Ml / 500 Ml Minimum, Insulation: Double-Walled Insulated Outer Container, Stirrer: Non-Corrosive Stirrer Provided, Thermometer Provision: Suitable Slot For Thermometer/Temperature Sensor, Lid Arrangement: Insulated Lid With Openings For Stirrer And Thermometer, Temperature Range: Ambient To 100°C, Least Count Compatibility: Suitable For 0.1°C Thermometer, Heating Arrangement: Compatible With External Heater / Immersion Heater, Mounting: Table-Top Laboratory Model, Accessories: Stirrer, Lid, Thermometer, Measuring Cup, And Connecting Accessories. , Solar Water Heater Performance Test Setup : Collector Type: Flat Plate Collector / Evacuated Tube Collector, Collector Area: 1 M² To 2 M² Minimum, Storage Tank Capacity: 50 Litres To 100 Litres, Tank Material: Stainless Steel Insulated Storage Tank, Absorber Material: Copper/Aluminium Absorber Plate With Selective Coating, Glazing Material: Toughened Glass Cover, Insulation: Mineral Wool / Puf Insulation Provided, Circulation Type: Natural Circulation / Forced Circulation System, Temperature Measurement: Digital Temperature Indicators At Inlet And Outlet, Flow Measurement: Rotameter / Flow Meter Provided, Pressure Measurement: Bourdon Pressure Gauge Provided. Heating Backup: Electrical Heater Backup Provision, Mounting Frame: Corrosion-Resistant Inclined Mounting Structure, Data Acquisition: Provision For Performance Analysis And Efficiency Calculation, Power Supply: 230 V Ac For Instrumentation And Heater Backup, Accessories: Connecting Pipes, Valves, Sensors, Control Panel And Experiment Manual
BOQ
| Sl. No. | Item Description |
| 1 | STRAIN GUAGE CHARACTERISTICS KIT – AC mains power supply:230 V +10%, 50 Hz, Metal foil strain gauge mounted on beam/cantilever, Strain measurement under applied load, Wheatstone bridge arrangement, Signal Conditioning and amplification circuit, Instrumentation amplifiers with 3 ½ digit display for strain/output voltage ,Zero and gain adjustment controls, Provision for applying calibrated loads, Table-top trainer with labelled panel, Test points for signal measurement, Built-in DC power supplies and wooden closed cabinet, Supplied with patch chords |
| 2 | LOAD CELL CHARACTERISTICS KITInput supply :230 v /50 Hz ac with regulated internal DC supply, Sensor: strain gauge load cell with suitable mounting arrangement ,Load range: 0-10Kg ,Display: digital display for load/output indication, CRO/test points: Test points provided for observing bridge output, amplifier output, and signal conditioning stages, Controls: Zero adjustment and calibration controls provided, Protection: Overload and short -circuit protection provided ,Accessories: Loading arrangement, connecting leads |
| 3 | MEASUREMENT OF TANK LEVEL USING ROTOMETERInput supply: 230 v/50 Hz with regulated internal DC supply ,Tank Arrangements: Transparent tank with 30 liters capacity with suitable supporting stand, Rotameter range: 0-4000 L/ hr calibrated rotameter, Flow system: pump, control valves, and piping arrangements provided for continuous flow operation ,Measurement facility: provision for flow -based tank level measurement and observation ,Display/observation: calibrated level indication with flow monitoring arrangement, Test points: output terminals provided for monitoring sensor /output signals , Accessories: connecting tubes |
| 4 | MEASUREMENT OF TEMPERATURE USING PT 100:Input supply : 230 v/50Hz ac with regulated internal DC power supply unit , Sensor: PT 100 resistance temperature Detector (RTD) probe with stainless steel sheath, Measurement principle: Resistance variation of platinum element with temperature, Temperature Range : 0 OC to 150OC (or suitable laboratory range ),Display unit: Digital temperature indicator with direct OC display, Accuracy: High accuracy with linearized RTD signal conditioning circuit, Signal conditioning: Built -in bridge circuit with amplifier and linearization ,Test points: Provided for RTD input, bridge output, amplifier output, and final display signal, Controls: Zero and span calibration adjustment for temperature calibration , protection: Over-voltage and short circuit protection for electronic modules , Accessories: Temperature bath or heater arrangement, connecting cables, user manual, and circuit diagram included. |
| 5 | TEMPERATURE MEASUREMENT TRAINER WITH PT 100, NTC, TC:Input supply: 230 v/50Hz ac with regulated internal DC power supply unit, sensors provided: PT 100 RTD,NTC thermistor, and thermocouple(TC-K type), Measurement principle: Resistance variation (PTC &NTC) and see back effect (thermocouple), Temperature Range: suitable for laboratory range (0OC to 150OC or higher depending on sensor), Display unit: Digital temperature indicator with selector switch for PT 100/NTC/TC, Signal conditioning: separate condition circuits for RTD bridge, thermistor network, and thermocouple amplifier, Test points: provided for sensor input ,conditioned output, and final display signal, Controls: sensor selection switch, zero/ span calibration , and temperature adjustment control, Protection : over- voltage and short circuit protection for electronic modules , Accessories: Heating source or temperature bath connecting leads |
| 6 | Bourdon tube pressure gauge: Analog indicating type , Measurement Ranges: 0 to 10 bar , Dial size: 100mm nominal dial diameter, Accuracy: + 1.6% of full scale(FS),Pressure element: bourdon tube made of phosphor bronze/stainless steel-case material: mild steel powder coated /SS304 stainless steel, window material: clear acrylic/glass, connection type: bottom entry/back entry,1/2\\" BSP threaded connection(or1/4\\" BSP as required), Mounting: Panel mounting / direct mounting , Scale: Dual scale: bar, psi, Pointer: Micrometre adjustable aluminium pointer, Operating Temperature: Ambient: –10°C to +65°C, Process fluid temperature: up to 80°C , Protection Class: IP54 minimum , Over Pressure Limit: 130% of full scale value , Calibration: Factory calibrated with calibration certificate |
| 7 | Differential Pressure Transmitter : Input Supply: 230 V / 50 Hz ac with regulated internal DC power supply unit, Tank Arrangement: Transparent tank with mounting stand for real-time liquid level observation, Tank Capacity: Laboratory-scale transparent tank with capacity 30 litres suitable for 0–100% level measurement, Differential pressure range: 0–100 mbar to 0–10 bar. Accessories: Complete piping, control valves and pump system for continuous water circulation and level variation, Display Unit: Digital indicator for real-time level measurement and monitoring, Output signal: 4–20 mA DC, two-wire system, Accuracy: ±0.1% of full scale, Test Points: Provided for DP input ports, transmitter output, and signal verification., Controls: Zero and span calibration adjustment for accurate level setting, Process connection: 1/4\\" NPT / 1/2\\" BSP female adaptor, Wetted parts material: SS316 stainless steel, Enclosure protection: IP65 / IP67, Communication: HART protocol compatible, Operating temperature: –20°C to +70°C. • Mounting: Wall/pipe mounting with bracket, Protection: Over-voltage and short-circuit protection for electronic and electrical modules, Over pressure protection: 150% of rated pressure. |
| 8 | Solenoid Valve Kit : Type: Electrically operated solenoid valve trainer / kit. ,Valve type: 2/2 way and 3/2 way normally closed (NC) solenoid valves, Operating voltage: 12 V DC / 24 V DC / 230 V AC, Port size: 1/4\\" BSP threaded connection. ,Body material: Brass / stainless steel, Seal material: Nitrile (NBR) / Viton, Operating pressure: 0–10 bar, Flow media: Air, water, and non-corrosive fluids, Coil insulation class: Class F or better, Protection class: IP65 minimum, Response time: Fast switching operation, Mounting: Panel/base mounting arrangement, Indicators: LED indication for valve ON/OFF status. Accessories: Connecting tubes, fittings, power cord, and control switches. |
| 9 | CALORIMETER: Vessel material: Copper / aluminium calorimeter vessel, Capacity: 250 ml / 500 ml minimum, Insulation: Double-walled insulated outer container, Stirrer: Non-corrosive stirrer provided, Thermometer provision: Suitable slot for thermometer/temperature sensor, Lid arrangement: Insulated lid with openings for stirrer and thermometer, Temperature range: Ambient to 100°C, Least count compatibility: Suitable for 0.1°C thermometer, Heating arrangement: Compatible with external heater / immersion heater, Mounting: Table-top laboratory model, Accessories: Stirrer, lid, thermometer, measuring cup, and connecting accessories. |
| 10 | SOLAR WATER HEATER PERFORMANCE TEST SETUP : Collector type: Flat plate collector / evacuated tube collector, Collector area: 1 m² to 2 m² minimum, Storage tank capacity: 50 litres to 100 litres, Tank material: Stainless steel insulated storage tank, Absorber material: Copper/aluminium absorber plate with selective coating, Glazing material: Toughened glass cover, Insulation: Mineral wool / PUF insulation provided, Circulation type: Natural circulation / forced circulation system, Temperature measurement: Digital temperature indicators at inlet and outlet, Flow measurement: Rotameter / flow meter provided, Pressure measurement: Bourdon pressure gauge provided. Heating backup: Electrical heater backup provision, Mounting frame: Corrosion-resistant inclined mounting structure, Data acquisition: Provision for performance analysis and efficiency calculation, Power supply: 230 V AC for instrumentation and heater backup, Accessories: Connecting pipes, valves, sensors, control panel and experiment manual Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender