Tender For Miscellaneous Electrical Works For 5Th Stream Refinery Expansion Project At Nalco, Damanjodi
Tender Overview
Project Description
Tender for Miscellaneous Electrical Works For 5Th Stream Refinery Expansion Project At Nalco, Damanjodi
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Jul-2026 | Corrigendum-1 | Date | 03-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | MISCELLANEOUS ELECTRICAL WORKSCable & Cabling:- Laying of cable (horizontal & vertical) of different voltage grades and size of following on existing steel structures in burried trenches, pulling through pipes, clamping on wall/roof(supply of proper clamps & hardware including supply and fixing of aluminium strips, identification tags, supply and spreading of fine river sand and supply and spreading of approved 2nd class bricks of 3\\" thickness in cable trenches in 3 sides of laid cable for cable protection etc, Making of straight through joints (if required). |
| 2 | Above 95 Sqmm and upto 300 Sqmm 1.1KV, PVC insulated and PVC sheathed armoured Aluminium Cable. |
| 3 | Above 25 Sqmm and upto 95 Sqmm 1.1KV, PVC insulated and PVC sheathed armoured Aluminium Cable. |
| 4 | up to 4C X 25 Sqmm cable 1.1KV, PVC insulated and PVC sheathed armoured Aluminim cable. |
| 5 | END TERMINATION:- Termination on switchgear, transformer, feeder piller, street light marshalling boxes, pole top boxes, lighting control panel of following sizes including connection of leads cutting stripping of cable insulation, providing compression type terminals,cripming of cable including supply of double compression cable glands, lugs etc, and all labour . Note-:The quantities mentioned in the BOQ are tentative in nature. However, supply shall be done after obtaining necessary clearance from Enigineer-In-Charge. |
| 6 | Above 95 Sqmm and upto 300 Sqmm 1.1KV, PVC insulated and PVC sheathed armoured Aluminium Cable. |
| 7 | Above 25 Sqmm and upto 95 Sqmm 1.1KV, PVC insulated and PVC sheathed armoured Aluminium Cable. |
| 8 | up to 4C X 25 Sqmm cable 1.1KV, PVC insulated and PVC sheathed armoured Aluminim cable. |
| 9 | Laying of 1.1 KV grade PVC armoured copper cable up to 4C X 6 Sqmm on wall along with supply and laying of single run 16SWG GI running earth wire, supply and fixing with suitable saddles, clamps complete as per direction of Engineer-In-Charge. |
| 10 | Replacement of Lighting Distibution Board up to 400AMP with up to 24 outgoings including fixing the same on wall/structure/ground and as per the direction of the Engineer-In-Charge (Nalco will supply LDB) |
| 11 | Installation of up to 400AMP feerder pillar and erection including transporatation /foundation/glanding & termination also including making of suitable base frame by cutting welding as required & as per the direction of the Eingineer-In-Charge NALCO will supply feeder Pillar. |
| 12 | Replacement/ Dismanlaing of post top lantern. All lighting fixture shall be supplied by Nalco |
| 13 | Post top lantern pole erection (Pole will supplied by Nalco) (fixing) |
| 14 | Dismantling of post top lantern pole. |
| 15 | Repairing of Earth pit chamber with necessary earthworks 500X500 size and 300 mm height up to ground level with concreting work, providing pre cast slab over the chamber including supply of materials. |
| 16 | Laying of HT Cable over any surface, clamping to the wall/pole/structure/Trays os Size 3C X 185-300 Sqmm, upto a height of 20M. All the tools & tackles, consumables, labour required for execution of the job are included in the scope of the contract. The work to be executed as per the direction of EIC. |
| 17 | Excavating of trench & laying/removal of HT Power Cables..supply & spreading of sand and laying of bricks, back filling etc..3C X 185-300 sqmm & as per the direction of Engineer-In-Charge. |
| 18 | Earthing , supply & installation. Testing and commsioning of class \\"B\\" GI earth electrode of 50MM dia and 3000 mm long complete with earth pit with RCC cover with all necessary materials including excavation of earth pit filling with layers of Charcoal & salt, back filling provideing necessary brick work slab cover, connection with GI strips should be interconnected to frame earth grid as per IE rule & as per IS 3043-1987 specification. Funnel is to be provided with wire mesh of suitable size on top of the funnel. All materials are included in the scope of the Party. |
| 19 | Dismantling of structure/Panels by gas cutting, unbolting, etc, shifting the dismantled structure/panles to designated location as per direction of Engineer-In-charge. |
| 20 | Painting of structures, panels, trays, junction boxes, equipment by preparation os surface to be painted by scubbing of surface by suitable tools, painting the same with one coat of primer & two coats of paint of either gray , white, yellow or blue colour including supply of paint of ASIAN PAINT/BERGER/DULEX/NEROLAC/ICI & as per the direction of Engineer in charge. All materials including paint, primer, brush & cleaning tools will be in the scope of contractor. Necessary scafolding should be made by the contractor of painting at height. |
| 21 | Laying of earth flat , supply, and laying of GI earthing strip/GI wire rope of following size including welding, cutting, painting,socketing,connecting the same with earth pit as required as per the direction of EIC. All the consumambles like gas, welding rod,welding machine,material etc are under the scope of party. Note-:The quantities mentioned in the BOQ are tentative in nature. However, supply shall be done after obtaining necessary clearance from Enigineer-In-Charge. |
| 22 | GI earth strip of size 50X6 mm |
| 23 | GI earth strip of size 75X10 mm |
| 24 | Supply and filling of gravels of size 35mm to 45mm in the indoor/outdoor transformer/4-Pole structure pit as per requirement , levelling the gravel taking precution of cables in the pit as per direction of EIC |
| 25 | Excavation of cable trench and removal of cable up to 3.5C X 300 sqmm, size inside Alumina Plant, rolling, measuring and depositing the same at Electrical store complete as requird and as per the direction of the Engineer-in-charge. |
| 26 | Dismantling of damaged street light pole marshalling box after disconnecting street light cables, earth leads, cable gland etc, refixing of same after repair reconnectiong street light cable , reconnecting earth leads and reglanding etc. Complete including supply of clamps and hardwares as per the direction of Engineer-in-charge. This included digging at pole pit to extraxt loop cables as required. |
| 27 | Laying of cables in the trench including supply and spreading sand, supply and laying of bricks, back filling etc. Only cable shall be supplied by Nalco. |
| 28 | Dismantling of damaged street light poles after excavation of earth, breaking of RCC foundation etc, removing of electrical fixture, disconnecting of marshalling box, cables, earth leads and returning the damaged poles to Nalco store, Complete as requird and as per the direction of the Engineer-in-charge. |
| 29 | Erection of street lighting poles after drawing from from stores, making of RCC foundation of 1:3:6, fixing of marshalling box, re-glanding and reconnection at location .Complete as requird and as per the direction of the Engineer-in-charge. |
| 30 | Removal of 1.1KV grade PVC armoured able up to 3.5C X 300 sqmm from cable tray, wall MS structures etc. Inside Alumina plant, measuring, rolling depositing the same at Nalco stores complete as per the direction of Engineer-in-charge. |
| 31 | Providing of temporary light fitting issuing from Nalco store of 24V incandescent lights/500w halogen flood light/ 250wHPSv/400W HPSV/200W LED etc, from nearest available point up to a maximum distance of 100meter, including cable laying, connection etc. |
| 32 | Removal of temporary installed light fitting of 24V incandescent lights/500w halogen flood light/250W HPSV/400W HPSV/200W LED etcc from nearest available point up to a maximum distance of 100mtr, include cable disconnection & removal of fittings & returning to Nalco Stores. |
| 33 | Circuit checking for power supply to luminaries, sockets, rectification of fault by replacing piece of burnt wire/fuse/replacement of MCB/replacement of switch, socket etc to resume power supply. |
| 34 | Excavating of trench & laying/removal of multicore power cable of voltage grade upto 1.1KV including (shifting of cables) with supply & spreading of sand, bricks, back filling etc Upto 3.5 x 70 sqmm. |
| 35 | Excavating of trench & laying/removal of multicore power cables of voltage grade upto 1.1KV including (shifting of cables) with supply & spreading of sand, bricks, back filling etc Above 3.5 X 70 sqmm & upto 3.5 X 300 sqmm. |
| 36 | Maintenance of High Mast Light fittings up to 400W MH/SV/LED including replacement of (if any) Lamp/choke/ignitor/Holder as required,greasing and cleaning of gear box with supply of all labor & as per the dierction of E.I.C. |
| 37 | Supply & Installation of LV Cable straight through jointing kit for 650 / 1100 V (Uo / U) voltage grade, Al / Cu conductor (stranded), XLPE insulated, screened, armoured, extruded PVC (FRLS) power / control / lighting cables. Note-:The quantities mentioned in the BOQ are tentative in nature. However, supply shall be done after obtaining necessary clearance from Enigineer-In-Charge. |
| 38 | From 10 to 16 Sqmm-Raychem/3M (with Supply & Instalation) |
| 39 | From 25 to 95 Sqmm-Raychem/3M (with Supply & Instalation) |
| 40 | From 120 to 185 Sqmm-Raychem/3M (with Supply & Instalation) |
| 41 | From 240 to 300 Sqmm-Raychem/3M (with Supply & Instalation) |
| 42 | Removal of the following damaged lighting fixtures complete from the existing location and refixing the same after repair /the new one drawing from stores and/or returning the damaged one to the stores , testing and re-commsioning the same (For item No 28.1 and 29 to 29.8) |
| 43 | 1 X 20W TUBE LIGHT /LED FIXTURES |
| 44 | 2 X 20W TUBE LIGHT/LED FIXTURES |
| 45 | 1 X 40W TUBE LIGHT/LED FIXTURES |
| 46 | 2 X 40W TUBE LIGHT/LED FIXTURES |
| 47 | 35W LPSV/LED FIXTURES |
| 48 | 80W HPSV/LED FIXTURES |
| 49 | 125W HPMV/LED FIXTURES |
| 50 | 150W HPSV/LED FIXTURES |
| 51 | 250W HPSV/HPMV/LED FIXTURES |
| 52 | 400W HPSV/HPMV/LED FIXTURES |
| 53 | Removal of damaged phase and neutral wires from existing conduit and supply, relaying the new stranded wires of following size of approved make in the same conduit including termination etc. in plant and public buildings, warehouse, complete as per the direction of Engineer-In-Charge. Note-:The quantities mentioned in the BOQ are tentative in nature. However, supply shall be done after obtaining necessary clearance from Enigineer-In-Charge. |
| 54 | 1.50 Sqmm size copper wire PVC insulated (660V) |
| 55 | 1.50 Sqmm size Aluminium wire PVC insulated (660V) |
| 56 | 2.50 Sqmm size copper wire PVC insulated (660V) |
| 57 | 2.50 Sqmm size Aluminium wire PVC insulated (660V) |
| 58 | Temporary laying of cable following sizes on ground, steel structures of any other surface including connection to panel to provide temporary power connection for a period of maximium 30 days or removal/dismantling and depositing the same at Nalco store (if supplied by Nalco) as per the direction Engineer-In-Charge. |
| 59 | Cable of size up to 10 Sqmm |
| 60 | Cable of Size (Above 10 Sqmm and up to 25 Sqmm) |
| 61 | Wiring and commissioning, including supply of following sizes of PVC insulated approved wire with PVC pipe/Casing capping on surface including supply of all materials, (With ISI). Note-:The quantities mentioned in the BOQ are tentative in nature. However, supply shall be done after obtaining necessary clearance from Enigineer-In-Charge. |
| 62 | 1.50 Sqmm size copper wire PVC insulated (660V) |
| 63 | 1.50 Sqmm size Aluminium wire PVC insulated (660V) |
| 64 | 2.50 Sqmm size copper wire PVC insulated (660V) |
| 65 | 2.50 Sqmm size Aluminium wire PVC insulated (660V) |
| 66 | Installation, testing, replacing, repairing and cleaning of following electrical items on switch board (Material shall be supplied by party.)Note-:The quantities mentioned in the BOQ are tentative in nature. However, supply shall be done after obtaining necessary clearance from Enigineer-In-Charge. |
| 67 | 5A Switch |
| 68 | 5A Scoket |
| 69 | 15A Switch |
| 70 | 5/15A Socket (Five pin) |
| 71 | 5/15A Combined Switch socket |
| 72 | Supply & Fixing of PVC switch box with 4nos of 5Amp switch & socket (Supply Box/ switch & socket) |
| 73 | Maintenance of Induction Motors by cleaning of motor body, fan cover, checking & cleaning of motor terminals, checking cable termination, IR value checking of motor, polythene covering of motor terminal box, checking earthing. Checking space heater if exist, checking tightness of pulley/coupling checking motor foundation tightness, checking of cooling system of monitor including removal & refixing of canopy, correction of defects if found during checking, submission of filled in check sheet & as per the direction of Engineer-in-charge. Contractor has to arrange cleaning material like cloth, CRC, blower, vaccum cleaner, all tools tackles required for the job etc. |
| 74 | Up to 15KW Motor |
| 75 | above 15KW upto 75KW motor |
| 76 | above 75KW upto 315KW motor |
| 77 | Installation of cable tray of size up to 600mm width with MS Clit and support welded to the structure members. The party shall supply all other material like arrangement of welding mechine, welding rods, gas cutter required for cutting & welding along with other materials etc, as required for installation & as per direction of Engineer-in-charge. |
| 78 | The below mentioned quantities in the BOQ are tentative in nature. However, supply shall be done after obtaining necessary clearance from Enigineer-In-Charge. |
| 79 | Supply & Installtion of End Termination in 11KV cable ..By heat shinkable cable jointing kit of Raychem/3M make as per direction of Engineer-In-Charge. |
| 80 | Supply & making straight through joint in 11KV cable ..By heat shinkable cable jointing kit of Raychem/3M make as per direction of Engineer-In-Charge. |
| 81 | Supply of Optical fibre Jointing Kit Outdoor type: GROUND BURIAL OPTICAL FIBRE CABLE JOINTING KIT SUITABLE FOR 48-CORE SINGLE MODE FIBRE. DETAIL DESCRIPTION JOINT CLOSURES SHALL BE A FIBRE SPLICE CLOSURE WITH INTEGRATED ORGANISER HAVING FOUR NOS ENTRY,DUST PROOF, PROTECTED AGAINST WATER WHILE IMMMERSE THE SAME IN WATER (SUITABLE FOR CONTINUOUS IMMERSION IN SALINE WATER, REUSABLE TYPE. THE JOINT CLOSURE SHOULD BE COMPLETE IN ALL RESPECT WITH ACCESSORIES SUCH AS SPLICE TRAY/ CASSETTES,ENOUGH STANDARD SPLICE PROTECTION SLEEVES, NUMBER MARKER, CLEANING SOLUTION,HEAT SHRINKABLE SLEEVES, TISSUE PAPERS ETC AND OTHER MATERIALS WHICH ARE NOT NENTIONED BUT NECESSARY DURING SPLICING. MAKE-KRONE,TYCO,RAYCHEM,3M ONLY |
| 82 | Supply of Telephone Cable straight through jointinng KIT/ JB Straight joint T.S.F-3/100 Pairs THERMO SHRINK TELEPHONE CABLE JOINTING KIT FOR 100 PAIR/0.5MM PIJF CABLE DIA (TYPE TSF 3) WITH FOLLOWING ACESSORIES.WIRE CONNECTORS:200 NOS HEAT SHRINKABLE SLEEVE:1 NO ALUMINIUM CANISTER:1NO BRANCH OFF CLIP (SMALL):1 NO SEATH CONNECTOR ASSY: 1NO ADHESIVE ALUMINIUM STRIP: 1NO ADSHIVE PVC TAPE: 20M CLEANING LIQUID KIT A: 1 NO SEALANT TAPE: 1 NO TRANSPARENT PE SHEET: 1NO FILLING COMPOUND: 2NO CLEANING TISSUE: 2NOS EMARY STRIP: 2NOS ARMOUR CONTINUTITY WIRE: 1NO ADHESIVE POLYESTER TAPE: 5 M INSTALLATION INSTRUCTION: 1NO KIT PACKAGE: 1NO MAKE WESTERN CABLEX |
| 83 | TELEPHONE CABLE LAYING: Handling, shifting of cable drums from site-store / yard to the installation location, unpacking, laying of cables / wires in cable trays (either located above ground or inside RCC cable trenches) / directly buried underground / in sand filled cable trenches (excavation for trench will be paid separately)/ through above ground conduits (PVC / GI) clamped on wall or structure or through floor conduits as recommended by MANUFACTURER / applicable construction documents and other associated work so as to ensure the completeness of installation work. Testing, precommissioning and commissioning activities are included in the scope. Supply and installation spacer bars and saddles, dressing of cables using Stainless Steel cable ties, cable tags and ferrules (including all fixing hardware) as per the site requirement are included in the scope. Supply of water / fireproof compound (of reputed make) and sealing of openings for cable entries by applying the same (whether spare openings or openings with cables passing through) is included in the scope. Minor civil work such as chipping / drilling of through-holes / cutouts in floor / walls, replastering and making area good after work done, providing sleeves during the cable laying as per the site requirement and replastering the same (including appropriate voltage grade for cable protection, ordinary bricks, warning tapes, cable markers (including steel)the supply of consumable material for the same) is included in the scope. Installation of cable route markers (as applicable) shall be as per 'Installation Details - Power' and applicable construction documents. |
| 84 | Laying of Jelly filled Underground telecom Cable 100 P X 0.5 sq mm Telephone Cable |
| 85 | Laying of OPTICAL FIBRE CABLE in GI Pipe |
| 86 | COMMUNICATION CABLE JOINTING: Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembly and installation of straight through joint kits, installation of components supplied separately - as recommended by MANUFACTURER / applicable construction documents, and other associated work so as to ensure the completeness of installation work. Civil work such as construction of concrete chamber with cover (for cables directly buried underground) as per the site requirement (including the supply of consumable material for the same) is included in the scope. |
| 87 | GROUND BURIAL OPTICAL FIBRE CABLE JOINTING KIT SUITABLE FOR 48-CORE SINGLE MODE FIBRE. |
| 88 | Jointing of armoured/Unarmoured jelly filled Telecom cable. 100 P X 0.5 Sqmm Telephone cable(T.S.F-3/100 Pairs) |
| 89 | Installation and Fixing of DP Boxes and termination of Cable For M.S. CABINET FIR 500 Pair TELECOM D.P.BOX |
| 90 | PIPE FOR OFC & Telephone CABLE LAYING / PROTECTION : Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembly and installation of heavy duty rigid GI / PVC conduits on wall / concrete / steel structure (with edge protection grommet at either ends for GI conduits), cutting, bending of conduits and other associated work so as to ensure the completeness of installation work. Installation of GI clamps, reducers / adaptors for the conduits, tees, pull boxes as per the site requirement and the associated work is included in the scope. Supply of waterproof compound (of reputed make) and sealing of conduit openings after laying of cable by applying the same is included in the scope. Civil work such as chipping / drilling of through-holes / cutouts in floor / walls (as per the site requirement) and replastering and making area good after installation of conduits as per the site requirement (including the supply of consumable material for the same) is included in the scope. Supply of all fixing hardware as per the site requirement is included in the scope. Installation of GI Pipes Both on Surface as well as underground and laying of armoured underground jelly filled cables upto 100Pair /OFC Cable |
| 91 | 2\\" size GI Pipe |
| 92 | 4\\" size GI Pipe |
| 93 | DISMANTLING ACTIVITIES: Removal / Dismantling of existing electrical installations, shifting it to lay down area within NALCO premises as per instructions from engineer in charge. Dismantling of equipment, structure steel includes removal by flame cutting (wherever permissible), grinding/ finishing/ painting the surface after cutting. Supply of consumables tools and tackles, safety items, scaffolding , crane of suitable capacity etc. Contractor shall use suitable vehicles for transportation, loading/ unloading. Contractor shall visit to site to check requirement tools, crane, truck etc. and consider necessary cost in offer. Following activities may contain minor civil works like excavation, chipping, removal & handling of structural steels used for electrical items |
| 94 | Perforated Cable Tray up sizes 300 mm width |
| 95 | Ladder Cable Tray sizes up to 300 mm width |
| 96 | Ladder Cable Tray up to sizes from 300 mm up to 600 mm width |
| 97 | GI / PVC Conduit of sizes up to 50 mm dia |
| 98 | Removal of armoured / unarmoured Cables from cable tray, conduit, built up trenches of following sizes |
| 99 | Cables of overall dia up to 23 mm |
| 100 | Cables of overall dia from 23.1 mm up to 37 mm |
| 101 | Cables of overall dia from 37.1 mm up to 48mm |
| 102 | Cables of overall dia from 48.1 mm up to 61 mm |
| 103 | Cables of overall dia above 61.1 mm |
| 104 | Removal of pipe / plate electrodes (Scope includes breaking of chamber, excavation of soil, removal of electrode, backfilling / compacting the area) |
| 105 | Removal of earthing strip of various sizes. |
| 106 | Removal of GI earth wires up to 16 mm dia |
| 107 | Dismantling of boards shall be as per applicable documents. |
| 108 | Shipping section / Unit weight upto 100 kgs |
| 109 | Shipping section / Unit weight from 101 kgs to 500kgs |
| 110 | Shipping section / Unit weight from 501 kgs to 1000kgs |
| 111 | Shipping section / Unit weight from 1001 kgs to 1500kgs |
| 112 | Shipping section / Unit weight from 1501 kgs to 3000kgs |
| 113 | Dismantling of boards shall be as per applicable documents.Floor Mounted Auxiliary Boards/ Equipment |
| 114 | Panel / Unit weight upto 5 kgs |
| 115 | Panel / Unit weight from 6 kgs to 20 kgs |
| 116 | Panel / Unit weight from 21 kgs to 100 kgs |
| 117 | Panel / Unit weight from 101 kgs to 200 kgs |
| 118 | Installation of earth conductor laid underground, Excavation of soil up to the required depth, installation of earth conductor (GI strip), back filling and compacting of soil and disposing the excess soil, termination as required .For GI earthing conductors, laying of conductor including bending, drilling, welding / jointing as required is included in the scope.For GI earthing conductors, supply and application of coal tar bituminous paint or cold galvanising paint on welded joints is included in the scope. |
| 119 | 25 x 3 mm GI strip |
| 120 | 40 x 5 mm GI strip |
| 121 | 50 x 10 mm GI strip |
| 122 | 75 x 12 mm GI strip |
| 123 | Installation of earth conductor laid on wall / concrete / steel structure / cable trays.Installation of earth conductor (GI strip) on wall / concrete / steel structure / cable trays by cleating at every 500mm, termination as requied.For GI earthing conductors, laying of conductor including bending, drilling, welding / jointing as required is included in the scope.For GI earthing conductors, supply and application of coal tar bituminous paint or cold galvanising paint on welded joints is included in the scope.Supply of all fixing hardware as per the site requirement is included in the scope.Earthing cables laid aboveground is considered separately in SECTION - B. |
| 124 | 25 x 3 mm GI strip |
| 125 | 40 x 5 mm GI strip |
| 126 | 50 x 10 mm GI strip |
| 127 | 75 x 12 mm GI strip |
| 128 | Installation of earth conductor to be embedded in finished concrete floors.Installation of earth conductor (GI strip / bare copper) on concrete floors.For GI earthing conductors, laying of conductor including bending, drilling, welding / jointing as required is included in the scope.For GI earthing conductors, supply and application of coal tar bituminous paint or cold galvanising paint on welded joints is included in the scope.Civil work such as chipping / drilling of through-holes / cutouts in floor and replastering and making area good after installation of conductor as per the site requirement (including the supply of consumable material for the same) is included in the scope. |
| 129 | 25 x 3 mm GI strip |
| 130 | 40 x 5 mm GI strip |
| 131 | 50 x 10 mm GI strip |
| 132 | 75 x 12 mm GI strip |
| 133 | AUXILLIARY BOARDS (Wall mounted) excluding panels listed under. Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of equipment, assembling and installation of components / devices supplied separately - as recommended by MANUFACTURER / applicable construction documents, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Minor civil work such as chipping, grouting for fixing of equipment / assemblies and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope. Supply of all fixing hardware as per the site requirement is included in the scope.Installation of boards shall be as per applicable construction documents. |
| 134 | Shipping section / Unit weight upto 100 kgs |
| 135 | Shipping section / Unit weight from 101 kgs to 500kgs |
| 136 | Shipping section / Unit weight from 501 kgs to 1000kgs |
| 137 | Shipping section / Unit weight from 1001 kgs to 1500kgs |
| 138 | Shipping section / Unit weight from 1501 kgs to 3000kgs |
| 139 | AUXILLIARY BOARDS (Wall mounted) excluding panels listed under.Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of equipment, assembling and installation of components / devices supplied separately - as recommended by MANUFACTURER / applicable construction documents, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Minor civil work such as chipping, grouting for fixing of equipment / assemblies and replastering the same as per the site requirement (including the supply of consumable material for the same) is included in the scope. Supply of all fixing hardware as per the site requirement is included in the scope.Installation of boards shall be as per applicable construction documents. |
| 140 | Panel / Unit weight upto 5 kgs |
| 141 | Panel / Unit weight from 6 kgs to 20 kgs |
| 142 | Panel / Unit weight from 21 kgs to 100 kgs |
| 143 | Panel / Unit weight from 101 kgs to 200 kgs |
| 144 | Anchor fasteners Supply & Installation of heavy duty Galvanised steel/SS anchor fasteners for supporting various equipment, in brick work / concrete workInstallation of anchor fasteners indicated below excludes those already considered in various applicable 'Installation Details'. |
| 145 | Anchor fasteners M8 type x 60mm |
| 146 | Anchor fasteners M10 type x 75 mm |
| 147 | Anchor fasteners M12 type x 100 mm |
| 148 | LIGHTING WORKS: Handling, shifting from site-store / yard to the installation location, unpacking, erection, alignment, assembling and installation of lighting fixtures, assembling and installation of components / accessories such as lamps, chokes, condensers, reflectors, control gear box for non-integral ffixtures etc. supplied separately - as recommended by MANUFACTURER / applicable construction documents, checking of internal wiring, stenciling with paint on equipment enclosures as required and other associated work so as to ensure the completeness of installation work.Testing, precommissioning and commissioning activities are included in the scope. |
| 149 | Fabrication and installation of steel support structure / supporting frames for equipment as per the site requirement, is considered separately in SECTION - F.Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F.Installation of lighting fixtures shall be as per 'Installation Details - Lighting' and applicable construction documents.Supply of all the Installation Material for lighting fixtures (and lighting poles as applicable) as per 'Installation Details - Lighting' and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work is included in the scopeControl gear boxes for non-integral type lighting fixtures are a separate item, and installation type designation for the same is indicated as separate line item below.Industrial / For Explosive Atmospheres type lighting fixtures (Integral type / Non-Integral type with control gear box) |
| 150 | Fluorescent lighting fixtures |
| 151 | Installation Type : LFLC1 |
| 152 | Installation Type : LFLC2 |
| 153 | Installation Type : LFLC3 |
| 154 | Installation Type : LFLC4 |
| 155 | Installation Type : LFLF2 |
| 156 | Installation Type : LFLT1 |
| 157 | Well glass lighting fixtures |
| 158 | Installation Type : LWGC1 |
| 159 | Installation Type : LWGC2 |
| 160 | Installation Type : LWGC3 |
| 161 | Installation Type : LWGR1 |
| 162 | Installation Type : LWGS1 |
| 163 | Installation Type : LWGS2 |
| 164 | Installation Type : LWGS3 |
| 165 | Medium bay / high bay lighting fixtures |
| 166 | Installation Type : LHBS1 |
| 167 | Flood lighting fixtures |
| 168 | Installation Type : LFDC1 |
| 169 | Installation Type : LFDC2 |
| 170 | Installation Type : LFDR1 |
| 171 | Installation Type : LFDS1 |
| 172 | Installation Type : LFDS2 |
| 173 | Street lighting fixtures-Civil work such as excavation of soil, making of foundation of lighting pole, backfilling and making area good etc. as per the site requirement (including the supply of consumable material and including supply of street lighting pole for the same) is included in the scope. |
| 174 | Installation Type : LSTP1 |
| 175 | Installation , Testing of all type of lighting Fixture with all hardwares excluding supply of materials. |
| 176 | Steel Structure Fabrication & erection of supports(Material shall be free issued from NALCO) .All the tools & tackles, consumamable, labour required for execution of the job are included in the scope of contract. The work to be executed as per the direction of the EIC. |
| 177 | Supply of structural steel-Fabrication, erection (by welding / fixing by anchor fastners), surface preparation and painting of structural steel as per the applicable construction documents so as to ensure the completeness of installation work for all the electrical equipment / items mentioned in Section A to E above, and chequered plates as per the applicable construction documents .Supply of all consumables such as welding electrodes (Advani Oerlikon or equivalent), gas for cutting etc. are included in the scope. |
| 178 | Miscellaneous civil work-The below mentioned rates shall be applicable only if specifically agreed & approved by OWNER / CONSULTANT. |
| 179 | Chipping / drilling of through-holes / cutouts in concrete floor / beam, replastering and finishing the same |
| 180 | Chipping / drilling of through-holes / cutouts in brick walls and replastering the same. |
| 181 | Manual excavation of all types of soil and backfilling the excavated area, consolidation after backfilling and disposing the surplus earth at a point outside the site |
| 182 | The below mentioned quantities in the BOQ are tentative in nature. However, supply shall be done after obtaining necessary clearance from Enigineer-In-Charge. |
| 183 | Supply and Laying of RCC NP 2 hume pipes of dia 150mm for road crossing including excavation of road upto a depth of 1500 mm back filling and consolidating the surface. |
| 184 | Supply of RCC hume pipes of reputed make as required, and civil work such as excavation, installation of hume pipes (including the supply of consumable material for the same), backfilling is included in the scope.Installation of certified soft sand of 150 degC.cm/w resistivity in the concrete trenches build by others after laying of cables, compacting the same |
| 185 | Supply of 4CX2.5 MM2 MULTISTRAND ARMOURED COPPER CABLE MULTISTRAND ARMOURED COPPER CABLEFor detailed technical specification refer Annexure 'A'. |
| 186 | Supply of 3CX2.5 MM2 MULTISTRAND ARMOURED COPPER CABLE MULTISTRAND ARMOURED COPPER CABLEFor detailed technical specification refer Annexure 'B'. |
| 187 | Supply 3C x 300 Sq mm PVC insulated XLPE heavy duty cable suitable for 11 KV (UE)For detailed technical specification refer Annexure 'C'. |
| 188 | Supply Of 3.5C X 300 sq.mm (Stranded).AL.Power 1100V grade, Al conductor XLPE, Insulated armoured FRLS power cable.For detailed technical specification refer Annexure 'D'. |
| 189 | Supply Of 4 C X 16 sq.mm (Stranded) AL Power 1100V grade, Al conductor XLPE, Insulated armoured FRLS power cable.For detailed technical specification refer Annexure 'E'. |
| 190 | Prefabricated Cable Trays (GI and Epoxy painted)Supply of prefabricated GI perforated and ladder type cable tray / covers, tray separators along with all the associated consumable material for assembly and apprpriate installation of the same. |
| 191 | 300 mm wide For detailed technical specification refer Annexure 'F'. |
| 192 | 600 mm wide For detailed technical specification refer Annexure 'G'. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender