Tender For Renovation Work Of Room Ag-02 To Ag-18 In Cautley Bhawan At Iit Roorkee. (Civil Works)
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Jul 2026
4 days left
EMD
70000
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Haridwar → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Work Of Room Ag-02 To Ag-18 In Cautley Bhawan At Iit Roorkee. (Civil Works)
BOQ
| Sl. No. | Item Description |
| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 2 | 1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 5 | Suspended floors, roofs, landings, balconies and access platform |
| 6 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 8 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1 :4 (1 cement : 4 coarse sand) |
| 10 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 11 | Granite stone slab of all colour and texture except black, Cherry/ Ruby red |
| 12 | Area of slab upto 0.50 sqm |
| 13 | Area of slab over 0.50 sqm |
| 14 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 15 | Providing and fixing ISi marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) Size 200x10 mm |
| 16 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 17 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: |
| 18 | Profile C fixing with adjustable lugs with split end tail to each jamb |
| 19 | Profile E fixing with adjustable lugs with split end tail to each jamb |
| 20 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1 :3:6 (1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) |
| 21 | Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 22 | 10 x 60 mm |
| 23 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 24 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4 mm thick glass panes |
| 25 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of sizeSize of Tile 600 x 600 mm |
| 26 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm |
| 27 | Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. |
| 28 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 30 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 31 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 32 | With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litreCode Description |
| 33 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 34 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 35 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 36 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 37 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 38 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 39 | In cement mortar |
| 40 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below |
| 41 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 42 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 43 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 44 | Providing and laying heavy duty tiles in size of Tile 600x600 mm with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including joints grouting of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 45 | Providing and laying heavy duty tiles in size of Tile 600x600 mm with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness. |
| 46 | Providing and fixing 35 mm thick ISI mark ply flush door shutters non-decorative type of century ply make or equivalent approved make complete in all respects as per directions of EIC |
| 47 | Providing and fixing 32 mm thick ISI mark flush door shutters non-decorative type of centuryply make or equivalent approved make complete in all respects as per directions of EIC |
| 48 | Providing, mixing and applying 12 mm thick ready mix cement plaster of approved make as per specifications and directions of Engineer-in-charge. |
| 49 | Providing, mixing and applying 15 mm thick ready mix cement plaster of approved make as per specifications and directions of Engineer-in-charge. |
| 50 | Providing and laying heavy duty tiles in size of Tile 600x600 mm with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness. |
| 51 | Providing and fixing 250x16 mm size Stainless Steel Aldrop of Dorset make model no. ALDSM (250x16) or equivalent approved make with nuts and SS screws etc. complete. |
| 52 | Providing and fixing 300x16 mm size Stainless Steel Aldrop of Dorset make model no. ALDSM (300x16) or equivalent approved make with nuts and SS screws etc. complete. |
| 53 | Providing and fixing Door mounted hanging type Door Stopper of Dorset make model no. DS HT (Z) or equivalent approved make with SS screws etc. complete. |
| 54 | Providing and fixing 10 inch length and 10mm dia square shape Stainless Steel tower bolts of Dorset make model no. TS-1010-10\\" or equivalent approved make with SS screws etc. complete. |
| 55 | Providing and fixing 12 inch length and 10mm dia square shape Stainless Steel tower bolts of Dorset make model no. TS-1210-12\\" or equivalent approved make with SS screws etc. complete. |
| 56 | Providing and fixing 2 x 150 mm size bright /matt finished Stainless Steel cabinet handles of kich make model no. PRCH426C or equivalent approved make with SS screws etc all complete |
| 57 | Providing and fixing 2 x 125 mm size bright /matt finished Stainless Steel Cabinet handles of kich make model no. PRCH425C or equivalent approved make with SS screws etc all complete |
| 58 | For Calculation purpose only |
| 59 | Sub Total (A) |
| 60 | Supplying and Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge with modular type switch, modular plate, suitable GI box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc. as required. |
| 61 | Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable make and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in existing surface/ recessed steel/ PVC conduit including dismantling as required. |
| 62 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. |
| 63 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc. as required.. |
| 64 | Supplying and Wiring for circuit/ submain line with 2x2.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge along with 1 no 2.5 mm² FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 65 | .....do..... but 2x4 mm² + 1x4 mm² earth wire |
| 66 | .....do.....but 2x6 mm² + 1x6 mm² earth wire |
| 67 | do-- but 4 X 16 mm² + 2 X 6 mm² earth wire |
| 68 | Supplying and drawing 3 x 1.5 mm² sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/PVC conduit as required with connection complete. |
| 69 | --do-- but 3 X 2.5 mm² |
| 70 | Supplying and fixing 5/6 amps modular type switch on existingmodular type plate & switch box including connections but excluding modular plate etc. as required. |
| 71 | do-- but 5 pin 5/6 amp socket outlet |
| 72 | do-- but stepped type electronic fan regulator |
| 73 | do-- but modular blanking plate. |
| 74 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 75 | Providing and fixing 125 amp, 16 KA, rating and breaking capacity TP MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. |
| 76 | Supplying and fixing of 12-way, double door prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 77 | Supplying, installation, testing and commissioning of surface/ recess mounting, vertical type, 415 volts, prewired, TPN MCB distribution board of sheet steel, dust protected, duly phosphatized and powder painted, inclusive of 200 amps tinned copper busbar, common neutral link, earth bar, din bar for mounting MCB's , detachable gland / knock out plate and superior make terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/neutral link and ready for installation of 4 ways (4+12) double door(but with out MCB's and incomer MCCB) as required. |
| 78 | Supplying and fixing 5 amps to 32 amps rating single pole, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 79 | do-- but 40 to 63 amp SP MCB |
| 80 | .....do..... but 40 to 63 amp DP MCB |
| 81 | do-- but 40 amps DP RCCB |
| 82 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 83 | Making hole for installation of exhaust fan of size upto 450 mm sweep by demolishing brick work manually/by mechanical means including disposal of malba within 50 meters lead and making good the wall by plastering etc. as required. |
| 84 | SITC of 240 V, 250 MM sweep PVC body exhaust fan in existing opening and making good finish with plaster and all masonary work, connection with 1.5 mm² PVC insulated, copper conductor, single core etc. |
| 85 | Supply, Installation, Testing and Commissioning of 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum), ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply earthing etc. complete as required |
| 86 | Supplying, installation, Testing & Commissioning of 18-22 watt LED surface mounted Batten light (System Lumen efficiency>=105) of Powder coated die cast/ Extruded aluminium body (thickness>=1.20mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 mm² FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender