Tender For Repair And Maintenance Work Of Traffic Light Installed At Keer Kheda Chouraha And Pratap Nagar Chouraha In Chittorgarh Area. (Annual Rate Contract)
Tender Value
14.32 Lakhs
Estimated cost
Bid Submission
15 Jul 2026
3 days left
EMD
28658
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chittorgarh → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Work Of Traffic Light Installed At Keer Kheda Chouraha And Pratap Nagar Chouraha In Chittorgarh Area. (Annual Rate Contract)
BOQ
| Sl. No. | Item Description |
| 1 | S.I.T.C. of programmable three digit digital countdown timer with 5mm dia. Red colored LEDs of high intensity (visible clearly at day time) of reputed make with digit size 150mm x 300mm approx. and quantity of LEDs be approx. 800 no.s including interconnection with traffic signal controller and housing the LED assembly in sheet metal box of size approx. 750mm x 550mm with detachable pole arms clamps etc. as required. |
| 2 | S.I.T.C. of following colour retrofit LED matrices traffic light of modular size 300 mm dia, Covered with front clear acrylic sheet and back with aluminum body, InP/InGaN based 5mm dia. Coloured LEDs of ultra bright. Super intensity (visible clearly at day time up to distance 300-600 meter, viewing angle of 30 degree). The unit shall be suitable for working on A.C. supply (160-240 V) and life cycle approx. 10 yrs with power consumption below 24 watts, suitable for fast switching. Red/Amber Round (unit of 200-220 Nos LEDs) |
| 3 | S.I.T.C. of following colour retrofit LED matrices traffic light of modular size 300 mm dia, Covered with front clear acrylic sheet and back with aluminum body, InP/InGaN based 5mm dia. Coloured LEDs of ultra bright. Super intensity (visible clearly at day time up to distance 300-600 meter, viewing angle of 30 degree). The unit shall be suitable for working on A.C. supply (160-240 V) and life cycle approx. 10 yrs with power consumption below 24 watts, suitable for fast switching. Green Arrow (Unit of 120-130 Nos LEDs) |
| 4 | All in all maintenance to keep up of complete traffic signal system in working order at a crossing including controller, posts, head assembly, bulbs/LED reflector, material (Consumables / Software of OEM of traffic signal to be used only) T&P etc. as required. With UTCS controller & LED Signal Heads |
| 5 | All in all maintenance to keep up of complete traffic signal system in working order at a crossing including controller, posts, head assembly, bulbs/LED reflector, material (Consumables / Software of OEM of traffic signal to be used only) T&P etc. as required. Programmable Three Digit Countdown timer Big/ Small |
| 6 | Supply & Fixing of Spare cards for UTCS microprocessor controller Microprocessor mother board Card-Bottom |
| 7 | Supply & Fixing of Spare cards for UTCS microprocessor controller Microprocessor mother board Card-Top |
| 8 | P/Laying P.V.C/XLPE insulated & P.V.C sheathed cable of 1.1 KV grade with Copper conductor of IS: 1554 P-I/IS: 7098 P-I in ground as per IS: 1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 2.5sq mm. Armored 4 core |
| 9 | Pipe Ear thing as per IS: 3043 with perforated 3.0 Mtr. Long, 40 mm dia. ‘B’ class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance as required. |
| 10 | P&FM.S. Cantilever swaged pole suitable for mounting signal head assembly of overall height 9.0 Mtr. (1.5 meter. Below ground level) with M.S. based plate of size 400mm x 400mm x 7mm including excavation of pit and grouting with P.C.C. of Ratio 1:3:6 from the bottom of the pole and up to 50cm above the ground level of 40 cm dia. Including painting with rubber coat below ground level and red oxide on exposed surface and finishing with two coats of traffic yellow enamel paint complete in all respect as required. The pole shall confirm following specifications as per IS:(1239 P-I) Top, middle, bottom length 1.80 Mtr, 3.60 Mtr., 6.0 Mtr. Respectively, outer dia. 88.9 mm, 114.3 mm, 139.7 mm respectively, thickness 4.05 mm, 4.5mm, respectively. |
| 11 | P & F 4.5 mm thick M.S. traffic post with outer dia. 114.3mm, medium class and confirming to IS:1239(P-I) 5Mtr. Long (0.8 Mtr. Below ground level) suitable for fiber cap and M.S. base plate 300 mm x 300 mm x 6 mm including excavation of pit and grouting with P.C.C. of ratio 1:3:6 from bottom of the pole and up to 30 cm. above the ground level and 40 cm. dia. Including painting with rubber paint below ground level and red oxide on exposed surface and finishing with traffic yellow enamel paint in two coats compete as required. |
| 12 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc. for following size of armored PVC insulated & PVC sheathed/ XLPE aluminum conductor cable of 1100 Volt grade as required of size. 4 X 2.5 sq.mm. |
| 13 | P &F in position frame made out of M.S. angle (riveted or welded) finished with two coat of red oxide and enamel paint including cutting, welding, holes etc. of following sizes as required. 40mm X 40mm X 5mm |
| 14 | P & Fixing Powder coated CRCA sheet enclosures on existing angle iron frame by means of nuts and bolts and making holes , Din rail etc. as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1.6 mm thick |
| 15 | SITC of microprocessor based logic type automatic electronic controller conforming to IS:7537 for traffic signals complete with electronic timer , control board, blinker unit for night operation and slip lane, day time peak hour operation, The controller shall have 12 Signal phases, 25 Signal plan, 24 cycle plan, 24 Signal split/ cycle, 4 Day plan, 32 Cycle switching/ day, 20 Selective Day plan/ annum, 16 Conflicting condition, 28 Signal Line, Solid-state relay switching, RS 422 Communication interphase, Manual override facility, up gradable vehicle actuated system, also have method of traffic control with fixed time isolated intersection and cable less/ cabled interlinking for synchronised operation. The controller unit shall be totally enclosed in 1.6 mm thick metal box including making connection. |
| 16 | Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Four pole 100/300 mA sensitivity 6A-32 A rating |
| 17 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 16.0 Sq. mm 4 core |
| 18 | Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 19 | Add Extra in Item no.60.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 20 | 32 mm dia HDPE pipe PN 6 (class PE-80) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender