Tender For special Repair To Bldg No. P-72/2A B Coy Cook House At 4/8 Gr Under Ge (North) Bangalore
Tender Overview
Project Description
Tender for special Repair To Bldg No. P-72/2A B Coy Cook House At 4/8 Gr Under Ge (North) Bangalore
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Jul-2026 | 8352Corrigendum | BOQ | 21-Jul-2026 |
| 2 | 21-Jul-2026 | 8352Corrigendum | Date | 24-Jul-2026 |
| 3 | 24-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 31-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of Cement Concrete (Un-reinforced) of any description and in any position not otherwise specifically provided for etc complete all as specified and as directed |
| 2 | Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for etc complete all as specified and as directed |
| 3 | Taking down chowkhats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each etc complete all as specified and as directed |
| 4 | Taking down chowkhats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4.0 Sqm each etc complete all as specified and as directed |
| 5 | M&L for 100 mm thick cement concrete 1:4:8, type B2 (using 40mm graded stone aggregate) as in sub base for path etc finished even and smooth w/o using extra cement. |
| 6 | M&L for 25 mm thick Cement concrete type B-0,1:2:4 (12.5mm graded stone aggregate) as in levelling course of flooing etc complete all as specified and as directed |
| 7 | M&L for 75 mm thick PCC 1:3:6, type C-1, using 20 mm graded stone aggregate as in plinth protection etc, finished even and smooth without using extra cement complete all as specified including joints filling with sealing compound Grade \\"A\\" complete all as specified and directed. |
| 8 | M & L for vitrified ceramic tiles dark shade double charged 10 mm thick (square / rectangular) area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 20 mm thick screed bed in CM 1:6 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 9 | All as per item No 8 above but as in skirting / dado incl chemical adhesive glue 10 mm thick in CM 1:3 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 10 | M & L for Non - skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in CM 1:6 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 11 | M&L' for Sand filling under floors or in foundations including watering and consolidation complate all as specified and directed . |
| 12 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified and as directed . |
| 13 | M&L Glazed ceramic coloured tiles 350x250x7mm / 450x350x7mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match incl backing coat 10 mm thick in CM 1:4 incl dismantling floor, hearth or wall tiling etc complete all as specified and as directed |
| 14 | M & L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, walls, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl 15 mm thick screed bed in CM 1:6 |
| 15 | M&L Pre-cast Cement concrete Type 1:3:6 using (20 mm graded stone aggregates) with solid blocks, exc 10 cm in width and setting in CM 1:6 incl demolition of brick Work / Stone Masonry/PCC block masonry built in cement mortar of any description all as specified and directed. |
| 16 | M&L for Pre-cast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 etc complete all as specified and directed. |
| 17 | M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed |
| 18 | Taking down cement plaster of any description hacking for key or raking out joint on old brick work/stone/concrete surface etc complete all as specified and as directed |
| 19 | M&L for rendering 10 mm thick in CM (1:6) on other than fair faces of brick work or concrete/stone masonry surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed |
| 20 | M&L for rendering 10 mm thick in CM (1:6) first layer and rendering 5 mm thick second layer in CM(1:4) on fair faces of brick work or concrete surface mixed with water proofing compound as per manufacture instruction finished even and smooth without using extra cement etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately |
| 21 | M&L for rendering for ceiling 5 mm thick in CM 1:3 on fair faces of brick work or concrete surface finished even and smooth without using extra cement etc complete all as specified and as directed |
| 22 | M&L providing cement concrete type B0 1:2:4 (12.50mm graded stone aggregate) in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs/Chajjas and the like including weathering, slightly rounded or chamfered angles and throating as directed |
| 23 | M&L for screed bed 10mm thick in CM 1:3 over concrete surface mixed with and incl water proofing compound incl taking down existing roof treatment etc along with cement plasartering etc complete all as specified and as directed. |
| 24 | M & L for removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017, 3mm thick and weighing not less than 3.00kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over compatible primer @ 0.30 Ltr/Sqm and torch applications of membrane with 100mm side overlap and 150mm end lap after necessary preparation of surface complete as per manufacture's instruction and applying a coat of aluminum paint on top @ 0.10 litre/Sqm complete all as specified and directed . |
| 25 | Supply only water proofing compound (Liquid) complete all as specified and as directed. |
| 26 | S&F 1.25 mm thick pressed steel frame of size 125 X 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed |
| 27 | S&F 1.25 mm thick pressed steel frame of size 105 X 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed |
| 28 | M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in hold fast and filling of pressed steel chowkat etc complete all as specified and as directed |
| 29 | S&F 35mm thick flush shutter solid core construction with decorative choice lamination both sides of shutter, kiln seasoned and chemically pressure treated complete all as specified and as directed |
| 30 | S & F 35 mm Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed |
| 31 | S&F Steel window Box type double side shutters (Windows side hung type , Ventilators top hung) pressed steel frames made out CRC Sheet of 80x60x1.25mm double rebated, Shutters box type made out of CRC Sheet of 40x20x1.0mm , windows & ventilator shutter fixed made of glass and gauge fixed with box type hinges, Aluminium die cast handles for glass shutters, Iron flat type handles for mesh shutters, Telescopic stays, etc complete all as specified incl 12mm square guard bars/grill welded with steel frame (100c/c horizontically) all as specified and directed by Engineer-in-Charge. NOTE: (i) Payment under this item will be make combined for steel frames, steel shutters and Guard bard/Grill, However unit rate quoted shall deemed to include cost of beading, fittings such as handles, hinges,Telescopic stays, locking arrangements and fixing of glass and wiremesh etc. (ii) Supply only 4 mm thick sheet glass and stainless steel wire mesh . (iii) Weight of Grill/Guard Bars, handle,hinges and locking arrangements shall not be accounted for payment purpose .(Note : All Windows/Vent design as per CECZ TD drg No 539) |
| 32 | S & F in repairs 18/19MM thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work,fixed in kitchen Cabinet or cupboards all as specified. |
| 33 | M&L for Plain fillets square, rectangular or triangular in section clean sawn , secured with nails or brads of second class hard wood fixed to cupboard shutter Not Exc 3 sqcm cross section area all as specified and directed. |
| 34 | M&L for Plain fillets square, rectangular or triangular in section clean sawn , secured with nails or brads of second class hard wood fixed to cupboard shutter exc 6 sqcm but Not Exc 13 sqcm cross section area all as specified and directed. |
| 35 | S & F in repairs 40 mm dia cupboard knobs fixed with nut, screw and washer of Brass, polished complete all as specified and as directed. |
| 36 | S & F in repairs 30 mm width of flap (when open) Continuous (piano) hinges, mild steel, bright finish or electro galvanised etc complete all as specified and as directed |
| 37 | S & F for solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete as sepecified and directed (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) |
| 38 | S&F factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick (Stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm plain colour PVC sheet on back face etc. complete all as specified and as directed. |
| 39 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed |
| 40 | S&F Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed |
| 41 | S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed |
| 42 | S&F 100 mm thick butt hinges, medium weight, Stainless steel and fixed etc complete all as specified and as directed |
| 43 | S&F 150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed |
| 44 | S&F 150 mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor etc complete all as specified and as directed |
| 45 | S&F Aluminium 100 mm Hasp and staple, safety type, mild steel hinge pin including bolt to hinge plate and fixed with screws etc complete all as specified and as directed |
| 46 | S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mmetc complete all as specified and as directed |
| 47 | S & F in repair vitreous china wash down water closet pan (Pedestal Pan) including fixing bolts, flush pipe anti syphonage pipe, plastic water closet seat , black closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device etc complete of cera model cat pt no. 2008 incl plastic EWC seat cover, coloured closed pattern with flat bottom and cover of cera model cat pt 2308 and mild steel chromium plated or aluminised hinging device etc complete all as specified and as directed |
| 48 | S&F in repairs vitreous china wash basin white, flat back, size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopper but including brackets, 32 mm bore waste stainless steel coupling and LDPE pipe 600 mm long complete all as specified and directed. |
| 49 | S&F in repair PVC flushing cistern with flush out valve low level of 10 Ltr capacity white with inlet ball valve, float, flushing bend & handle including brackets, etc complete all as specified and as directed |
| 50 | S&F in repair 15mm Bib taps Fancy type, Chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule etc complete all as specified and as directed |
| 51 | S&F in repair 15mm bore dia of pipe CP Mixer for mixing hot and cold water screwed down for iron pipe etc complete all as specified and as directed |
| 52 | S&F in repair 15mm dia Angle / Stop / Concealed cock, Fancy type cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed etc complete all as specified and as directed |
| 53 | S & F in repairs 15 mm Centre hole Basin mixture W/o Pop Up all as specified and as directed.(Cat No 6850 Marcus series of Prayag or equivalent make as specified in CA) |
| 54 | S&F in repairs 100 mm overhead shower ABS with brass Arm (225mm) & flange including fixing to steel pipe or union complete all as specified and as directed. (Cat No BS-67 of Prayag or equivalent make as specified in CA) |
| 55 | S&F in repairs Health faucet, brass body with 1mtr SS braided tube & wall hook complete all as specified and as directed (Cat No-BEA-41 of Prayag or equivalent make as specified in CA) |
| 56 | S & F in repairs Mirror 600x450 x 5-6mm thick with frame cat No BLM-01F of PRAYAG or equivalent make complete all as specified and directed |
| 57 | S&F in repairs SS Grab bar Towel rail 450 mm long incl fixing arrangement etc complete all as specified and as directed (Make Cat no GM-04 of Prayag of equivalent make of CA) |
| 58 | S & F 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors incl taking down existing GI/CPVC pipe line etc complete all as specified. |
| 59 | S & F 25mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors incl taking down existing GI/CPVC pipe line etc complete all as specified. |
| 60 | S&F in repairs rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I capacity of tank 1000 ltrs incl 25 mm dia of bore ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic etc complete all as specified and directed |
| 61 | S & F in repairs 25 mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and including taking down old gate valve all as specified and as directed. |
| 62 | S&F PVC connection 600mm long 15mm dia complete all as specified. |
| 63 | S&F in repairs 75 mm dia of PVC (SWR) Multi floor trap, plain with grating including jointing with solvent cement etc complete all as specified and as directed |
| 64 | S&F 110 mm PVC, SWR pipes, single socketed in any length with rubber ring joint laid in trenches or in floor etc incl dismantling of existing pipe line and fittings etc complete all as specified and directed |
| 65 | S&F 110 mm PVC, SWR pipes, single socketed in any length with rubber ring joint fixed on walls etc incl dismantling of existing pipe line and fittings etc complete all as specified and directed |
| 66 | S&F 75 mm PVC, SWR pipes, single socketed in any length with rubber ring joint laid in trenches or in floors incl dismantling of existing pipe line and fittings etc complete all as specified and directed |
| 67 | S&F 75 mm PVC, SWR pipes, single socketed in any length with rubber ring joint fixed on walls incl dismantling of existing pipe line and fittings etc complete all as specified and directed |
| 68 | S&F 110 mm dia PVC (SWR) bends (any radius) etc complete all as specified and as directed |
| 69 | S&F 110 mm dia PVC (SWR) bends (any radius) with acess door etc complete all as specified and as directed |
| 70 | S&F 75mm PVC (SWR) bends (any radius) etc complete all as specified and as directed |
| 71 | S&F 75mm PVC (SWR) bends (any radius) with acess door etc complete all as specified and as directed |
| 72 | S&F in repairs 110 mm dia bore PVC (SWR) vent cowls |
| 73 | Complete removal of existing treatment of wall surface (Internal and External) by means of wire brushing, sand paper, manually or mechanically up to visible of plastered surface incl rubbing and washing etc complete all as specified and as directed |
| 74 | M&L for 1mm thick wall care putty on wall including preparation of surface with sand paper etc to obtain smooth surface etc complete all as specified and as directed |
| 75 | M&L for Preparing new plastered suface of walls and applying two coats distemper oil emulsion, white or tinted over a coat of alkali resistance primer complete all as specified and as directed |
| 76 | M&L for Preparing old plastered suface of walls and applying two coats distemper oil emulsion, white or tinted over a coat of alkali resistance primer complete all as specified and as directed |
| 77 | M&L Preparing new /Old Previously untreated plastered surface of wall and Applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm including filling the cracks etc with crack filling material as per manufacturers instructions complete all as specified and as directed. |
| 78 | M&L for preparing newly plastered surface of ceiling and applying three coat of white wash etc complete all as specified and as directed |
| 79 | M&L for Preparing Old ceiling surface and applying one coat of white wash etc complete all as specified and as directed |
| 80 | M&L for Preparation of old painted wooden surfaces of any description, over 10 cm in width or girth , and applying one coats of synthetic enamel paint etc complete all as specified and as directed |
| 81 | M&L for Preparation of old or previously un-treated steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint etc complete all as specified and as directed |
| 82 | S&F in repairs stainless steel decorative curtain rod (including bracket) of 25 mm bore with wood finishes (weight not less 400 gms per running meter) incl fancy finale caps cap (02 nos in each curtain rod) etc complete all as specified and as directed |
| 83 | S&F in repair Brass Chromium Plated designer Bracket for curtain rod of dia 25 mm dia made out of SS Flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with Rawl Plug of size not less than 50 mm long etc complete all as specified and as directed |
| 84 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth and getting outin hard/dence soil type of soil |
| 85 | Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundations,filling and mass concrete. |
| 86 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc |
| 87 | Material and labour for pre-cast cement concrete block masonry with solid blocks,in PCC 1:3:6,Type C1,using 20mm graded stone aggregate,exc 10cm in width and setting in CM 1:4 |
| 88 | Demolition and breaking up drain pipes 150mm dia (salt glazed ware, AC or reinforced concrete ) set in cement mortar complete all as specified and directed |
| 89 | Material and Labour for laying of DWCPE Sewage pipes line 150 mm Inner dia bore of pipe class SN-8 incl sealing of joints, fittings etc complete with collars complete all as specified and directed |
| 90 | Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of 150mm bore after they are laid and tested . |
| 91 | All as per item No. 90 above here-in-fore but 12mm dia bars for handles conforming to Fe290Gde E-165 |
| 92 | M & L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed |
| 93 | Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as directed. |
| 94 | Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge. |
| 95 | Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit incl accessories concealed on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.One light / fan point controlled by one switch |
| 96 | All as per item No. 95 above but forOne 3 pin socket out let 5 Amps on independent board |
| 97 | Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit incl accessories s concealed on walls walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 2 & 3 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. |
| 98 | S&F in repairs LED batten suitable for indoor applications 20 Watts, 4 feet with extruded aluminium housing & integrated LED channel complete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No. equivalent Makes & model in Havells/Phillips/CG |
| 99 | S&F in repairs 2 x 2 Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. |
| 100 | Supply and Fix in repair Modular switch 1 way 6A,1 module |
| 101 | Supply and fix in repair modular type Fan step regulator, 120W - 2 module |
| 102 | Supply and fix in repair modular Socket, 6A - 2/3 pin combined 2 module |
| 103 | Supply and fix in repair Modular switch 1 way 16A, 1 module |
| 104 | Supply and fix in repair modular Socket 6A/16A - 2/3 pin combined 2 module, |
| 105 | S&F in replacement of MCB SPN 240 volts 32/40 Amps complete all as specified and as directed |
| 106 | S&F in replacement of MCB single pole 240 volts 10/16/20/32 Amps complete all as specified and as directed |
| 107 | S&F in replacement of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 108 | S&F in replacement of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 109 | S&F in replacement of MCB DB TPN 4 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 110 | S&F in replacement of MCB TPN 415 volts 10 KA 'C' 63 Amps complete all as specified and as directed |
| 111 | S&F in replacement of MCB TPN 415 volts 10 KA 'C' 100 Amps complete all as specified and as directed |
| 112 | S&F in replacement of ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 113 | S&F wall mounted fans complete with complete accessories, 230V, SP 400 mm Sweep with BEE 4 Star rating complete with all accessories and fixing the fan on wall with necessary items, etc all as specified and as directed .Make Havells, Model Swing and equivalent in Bajaj/CG/ USHA. |
| 114 | S&F Storage type water heater 25 Ltrs BEE 5 star rated complete incl steel wired pipe for hot/cold water connection for inlet and out let water etc complete all as specified and directed at site . |
| 115 | Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with suitable size of PVC conduit all as specified and as directed |
| 116 | Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, four runs of single core 10 Sqmm along with 10 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with suitable size of PVC conduit all as specified and as directed |
| 117 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed including dismantaling old unsv earthing. |
| 118 | Supply and fixing in repairs 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings and GI Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed. |
| 119 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete including necessary core cutting arrangement for installation all as specified and directed |
| 120 | S&F fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers complete including necessary core cutting arrangement for installation all as specified and directed |
| 121 | M & L for sand cushioning with a layer of M-sand 23 cm thick under and above the cable complete all as specified and as directed |
| 122 | S&L sub class 'B' burnt bricks for cable protection complete as specified as directed |
| 123 | S&L cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including taking out the existing unserviceable cable for following size4 C x 25 Sqmm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender