Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56333029

Tender For Provn Of Cooling Appliances With Walk-In Cooler Along With Necessary Electrification Work For Medical Store In Military Hospital Under Ge (Mh & Rh) Khadki

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
21.86 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
16 days left
EMD
43720
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provn Of Cooling Appliances With Walk-In Cooler Along With Necessary Electrification Work For Medical Store In Military Hospital Under Ge (Mh & Rh) Khadki

BOQ

Name of Work:- PROVN OF COOLING APPLIANCES WITH WALK-IN COOLER ALONG WITH NECESSARY ELECTRIFICATION WORK FOR MEDICAL STORE IN MILITARY HOSPITAL UNDER GE (MH & RH) KHADKI
Sl. No. Item Description
1Supply, installation testing and commisioning of inverter based wall mounted typed split Air Conditionar of capacity 1.5 Ton, 5 Star rating (Copper coil), electric driven single phase, 240 volts, 50 Hz supply, complete with indoor and outdoor unit, remote control, including all accessories like brackets, MS stand made out from suitable size of MS angle iron, copper tubbing nitrile rubber insulation including brazing, suitable size of PVC drain pipe, PVC insulation multistranded copper cable of suitable size from indoor unit to outdoor unit, and making good distrurbed surface to mach with the existing surface complete all as per specified and directed(Make: HITACHI/CARRIER/VOLTAS/ BLUE STAR 'O' general) Note: 1. All cooling and conditioning coil should be copper material.2. Mounting braket for outdoor unit is included in Quotated rates
2Supply, installation testing and commisioning of inverter based wall mounted typed split Air Conditionar of capacity 02 Ton, 5 Star rating (Copper coil) three star rating, electric driven single phase, 240 volts, 50 Hz supply, complete with indoor and outdoor unit, remote control, including all accessories like brakets, MS stand made out from suitable size of MS angle iron, copper tubbing nitrile rubber insulation including brazing, suitable size of PVC drain pipe, PVC insulation multistranded copper cable of suitable size from indoor unit to outdoor unit, and making good distrurbed surface to mach with the existing surface complete all as per specified and directed (Make: HITACHI/CARRIER/VOLTAS/ BLUE STAR 'O' general) Note: 1. All cooling and conditioning coil should be copper material.2. Mounting braket for outdoor unit is included in Quotated rates
3Supply, installation, testing and commissioning of Walk in chiller temprerature range + 2 Degree Celsius to + 8 Degree Celsius of size 96''x 96''x 96'' consisting of wall and ceiling PUFF panels of 60mm thick, Material PPGI/ PPGI with density 60 KG/M3 + -3, Flooring 60mm thick P P outer -18 GGI + Anti skid, Door : PUF-Flush in type swing door with 34\\" x 78\\" clear opening with accessories: Anti-condensation door Heater, Pad lock system, Posi seal closure, Human Safety release knob, Evaporator Unit & condenser unit: BLUE STAR LIMITED/ Carrier or equivalent make Split type - Air - cooled, 230/1/50 Regrigration Capacity offiered : 10,000 BTU/Hr x 2 Nos @ 4 Degree celsius room tempreture and 35 Degree celsius ambient split type - Air - cooled refigerant : R404A, 1 Working + 1 Standby, Fully SS indoor body, Hooter for rise in tempreture indication, lights inside the cold room 2 Nos, with necessary civil work required at site, stand for outdoor units complete as all specified and directed.
4Material and Labour for submain wiring in PVC casing & caping with two runs of 4 sq mm and one runs of 4 sqmm for earth continuity 1100 v grade PVC insulated unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS 694) drawn through and including 25 mm dia PVC rigid conduit heavy grade ISI marked (IS 9537 Part III) includung accessories such as bends, supports etc Note: Two runs of 4 sq mm and one runs of 4 sqmm cable along with conduit shall be measured as one length complete all as per specified and directed.
5Supply and fix in repair sheet metal enclosures with socket plug top and MCB 20 amp double pole factory made duly painted 240 ,AC concealed in wall suitable for fixing gyser /AC complete all as specified and directed.Make:L & T/legrand/Standard
6Supply and fix Heavy duty rust proof Mounting Bracket for Air conditioner outdoor unit which supports upto 150kg weight Air Conditioner with Necessary Wall Fittings complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56333029
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 21.86 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Cooling Appliances With Walk-In Cooler Along With Necessary Electrification Work For Medical Store In Military Hospital Under Ge (Mh & Rh) Khadki
Basic Detail
Tender No 8887/E8
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 06 Jul 2026
Submission Date 27 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 21.86 Lakhs
Tender Fee 500
EMD 43720
Exemption Not Available
Document List
31d8623a-928a-44d3-b779-db2340bedbfe.html
BOQ_869897.xls
Tender8887R.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

31d8623a-928a-44d3-b779-db2340bedbfe.html

xls

BOQ_869897.xls

pdf

Tender8887R.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders