Tender For special Rep To Bldg No P-27 (Squash Court), special Rep To Compound Wall Near Et Block (01 To 05) Of Aom Area, Provn Of Toilet Block At Nanjangud And Provn Of Artificial Recharge For Rwh With Micro Borewell At Asc Centre (North) Under Ge (
Tender Overview
Project Description
Tender for special Rep To Bldg No P-27 (Squash Court), special Rep To Compound Wall Near Et Block (01 To 05) Of Aom Area, Provn Of Toilet Block At Nanjangud And Provn Of Artificial Recharge For Rwh With Micro Borewell At Asc Centre (North) Under Ge (Central) Bangalore
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in Soft/loose soil complete all as specified and directed |
| 2 | Excavation in trenches in any type of soil n.exc 1.5m wide and n.exc 1.5m depth in foundations etc for manholes, sewage line, laying electric cables and and getting out complete all as specifed and directed. |
| 3 | Excavation over areas n.exc. 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc., and and getting out in hard /dense soil complete all as specified and directed. |
| 4 | Excavation over areas exc. 1.5 mtr but n.exc. 3.00 mtr in in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc., and getting out in hard /dense soil complete all as specified and directed. |
| 5 | Excavation in post holes each n. exc. 0.50Cum, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25cm, watering and removing surplus soil to a distance n. exc. 50m and making good surface. |
| 6 | M&L for PCC 1:4:8 type D2 (40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specifed and directed. |
| 7 | M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in fdn filling and mass concrete complete all as specified and directed. |
| 8 | M&L for hardcore of broken stone or boulders of gauge n.exc 63mm, deposited spread, and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 9 | M&L for 75 mm thick PCC type D2 1:4:8 (40 mm graded stone aggr) in sub base or sub floor etc complete all as specified and directed. |
| 10 | M&L PCC 1:3:6 type C2 75 mm thick (using 40mm graded aggregate) as in Plinth protection finshed the concrete surface even and smooth W/O using extra cement complete. |
| 11 | Demolition of brick work or stone/ boulder masonary, bult in cement mortor incl all quoins, arches, pillars etcincluding depositing unservicable brick and stacking for reuse including cleaning of bricks and deposting off all debries & rubbish off permises to a distance not exceeding 100 mtr complete all as specifed and directed. |
| 12 | M&L for Pre-cast cement concrete block masonry type C1, 1:3:6 using 20mm stone aggreage with solid blocks, exc. 10 cm in width and setting in mortar in CM 1:6, complete all specified and directed. |
| 13 | M&L for Walling of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and as directed. |
| 14 | Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specifed and directed. |
| 15 | Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed and directed. |
| 16 | Removal of excavated material (soil) to a distance exc 250m and not exc 1.5 KM and depositing where directed complete all as specifed and directed. |
| 17 | M&L for Rendering 15mm thick on brick or block masonry surfaces in cement mortar 1:4 mixed with water proofing compound where required finished even and smooth without using extra cement complete all as specified.Note : WPC will be measured and paid separately for the qty only where WPC will be used. |
| 18 | M&L for Rendering 15mm thick on brick or block masonry surfaces in cement mortar 1:6 finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for Rendering 5mm thick on fair faces of concrete surfaces as in ceiling in cement mortar 1:3 finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 20 | M & L for 40 mm thick damp proof course to horizontal or vertical surface including necessary form work in PCC 1:2:4 type B (using 12.5 mm graded stone aggregate) mixed with WPC complete all as specified and directed.Note : WPC will be measured and paid separately. |
| 21 | Supply only integral water proofing compound complete all as specified and directed |
| 22 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 23 | M & L for coloured Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 300X 7mm thick to 8mm mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl rendering 10 mm thick as backing coat in Cm 1:4 complte all as specified and directed |
| 24 | S&F TMT steel bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 25 | S&F TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending etc and securing as in stirrups complete all as specified and directed. |
| 26 | M&L for Cement concrete 1:3:6, type C1 (20mm graded stone aggregate) for lintels upto 1.5m span, cills, steps, coping, kneelers, apex stone, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specfied and directed |
| 27 | M&L for Cement concrete 1:2:4, type B1 (20mm graded stone aggregate) as in coping benching and surface channel finished fair and even incl necessary form work complete all as specified and as directed |
| 28 | M&L for use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, dirders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams complete all as specified and directed. |
| 29 | M&L for RCC nominal mix type B1, 1:2:4 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span and similar works complete all as specified and directed. |
| 30 | M&L for providing precast RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in Drain cover slabs, man holes cover, chullah hoods, chajjas, shelves set in cement mortar 1:4 complete all as specified and directed. |
| 31 | M&L for precast cement concrete louvres and jallies, 25mm thick (measured soilid), including all mouldings but excl frame type B0 1:2:4 (12.5mm graded aggregate) set in cement mortar 1:4 complete all as specified and directed. |
| 32 | S&F for precast RCC Collar rings NP-3, 1.5m dia, 50mm thick, each ring of height 0.45m having weep holes from the side of the ring laying in excavated tranches for soak pit or rain water harvesting percolation pit of any depth complete all as specified and directed by Engr-in-Charge(Note: Excavation and filling will be meaasured and paid sepratly) |
| 33 | M&L for loose filling with broken stone or boulder aggregates of gauge 80 to 150mm in bore well recharge well complete all as specified and directed |
| 34 | M&L for loose filling with broken stone or boulder aggregates of gauge 40 to 80mm in bore well recharge well complete all as specified and directed |
| 35 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches to connect the pond and recharge well, the mouth PVC pipe at the side of pnd has to be covered with HDPE woven fabric/textile for filtration all as specified and directed by engr-in-charge.Note : HDPE woven fabric/textile for filtration shall be measured and paid as supplied only item separately. |
| 36 | Spply only HDPE woven fabric/textile complete all as specified and directed |
| 37 | M&L HDPE pond liner Blue or Black in colour having thickness of 500 micron or above without joints and if jointed as per manufacturers instructions complete all as specified and as directed |
| 38 | M&L for trial bore of 50 mm dia upto 60 mtr depth below the ground level in any type of soil strat incl electric logging, MS Cap, MS flat iron clamps, reducing socket etc complete all as specfified and directed. |
| 39 | M&L for reaming upto 525mm from depth exceeding 60 mtr to 200 mtr incl casing pipe of 150 mm dia and thickness 6mm and pea gravel complete all as specified and directed |
| 40 | M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gms/Ltr and UV resistance as per IS 15489:2004, alkali & fungal resistance dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre/10 sqm over and inclduing priming coat of exterior primer applied @ 0.90 ltrs/10 sqm over new surfaces complete all as specified and directed. |
| 41 | M&L for complete removal of existing Maple Hard Wood from the existing surface and cleaning the court with skilled man power and tools complete all as specified and directed. |
| 42 | Supply, Installation and testing of wooden flooring for squash court consisting of the following :-Surface Board : surface board will be of Approved Standard Maple Hard Wood Sports Flooring with Tested and Seasioned Treated Hardwood of Size 20 MM Thick x 57 MM Wide and in random length in tongue and groove shape. The edges of the boards will have a finger lock groove and the bottom side with air pass groove and treated with special anti termite and water resistant lacquer. Under Frame : under frame will consisting of 45MM x 70 MM x 1.22 Meter Treated Sleepers Installed at 9\\" (23CM) Distance with 10 MM Thick Power Pads. Finishing : After laying the flooring, the floor boards will be levelled to a uniform surface and Sanding of court by 60 x 120 grid paper and termite treated. Note : Specifications of the above Squash Court wooden flooring will be as under :-(a) 6 mil Polyethylene shall be laid on the IPS Surface as vapour barrier(b) Sleepers - 40 MM x 57 MM x 1.22 M Fir / Spruce or Pine, Treated with Borate shall be installed at 9\\" Distance(c) These sleepers have 19mm Power Pads properly stapled at 10\\" distance. These Power Pads are three/four conical Thermal Rubber (TPR) with reverse cavity.(d) Strips in size 20mm x 57mm/83mm, in Random Lengths of 300mm - 1830mm, tongue & groove, Kiln & Dried and Treated shall be installed over the sleepers.(e) The floor thus laid shall be machine sanded with drum sander - one time - i.e. coarse grade (60grit) sandpaper to leave a \\"nap\\" on the floor for non slipperiness. The floor shall not be sealed(f) Thereafter game lines painting/marking shall be applied (g) Game lines painting/marking will be measured and paid separately. |
| 43 | M&L for cleaning of surfaces to remove dust, grease, laitance and loose particles making surface even & ready for coating and painting/marking of game line of complete squash court of size 65 Sqm as per WSF approved standered by applying two or more coates of high impact resistance, non reflective finish washable and durable coating complete all as per manufacturer's instruction and WSF directions.. |
| 44 | Demolition of cement concrete (unreinforced) as in floors and paving n exc 15cm thickness (below or above ground level) including deposal off rubbish to a distance not exc 100 mtr all as specified and directed. |
| 45 | M&L for 25mm thick Cement concrete 1:2:4, type B0 (12.50mm graded stone aggregate) as in sub base for flooring or levelling course complete all as specified and directed. |
| 46 | Taking down cement plaster of any description on brick or block wall ceiling and concrete surface etc including rackimg out joints,hacking for keys all as specifed and as directed by Engineer-in- Charge. |
| 47 | Cutting/chipping the spalling concrete surfaces of columns, beams, facias, slabs, Chajjas & cartilevers etc., and trimming cleaning the surfaces of any thickness all as specified and directed. M/L for applying epoxy treatment for bonding old demolished concrete surfaces incl application of one coat of notozinc primer to the exposed reinforcement and over plastering in CM 1:4 average 20mm thick finishied even and smooth without using extra cement to level the surface etc incl necessary scafolding as required at site and where required complete all as specified and directed |
| 48 | Taking down shutters of any description exc 2.00 Sqm each complete all as specified and directed |
| 49 | S&F 40mm thick shutters, solid core construction with block core and plywood face panels commercial type on both sides complete all as specified and directed. |
| 50 | Taking down and refixing of toughened glass 12 mm thick clear to standing glass back wall system at site complete all as specified and directed. |
| 51 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube all as per specification & drawing shown in SSR Part - II (2020) complete as specified and directed. |
| 52 | S&F Factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing shown in SSR Part II (2020). |
| 53 | S&F MS butt hinges medium weight, cold rolled 100mm size complete all as specified and directed. |
| 54 | S&F Aluminium anodised barrel tower bolt 150 mm long of extruded section etc complete all as specified and directed. |
| 55 | S&F Extruded Aluminium anodised alloy handles fabricated type 150mm long complete all as specified and directed. |
| 56 | S&F 300mm aluminium alloy, anodized, sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 57 | S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with aluminium wire staples with wodden beading on wooden shutter or with screws to steel / aluminium shutter complete all as specified and directed. |
| 58 | M&L for preparing of newly plastered surfaces of wall and applying two coats of distemper oil bound over a coat of wall care putty 1.5mm (average) thick over a coat of chalk whiting priming coat complete all as specified and directed. |
| 59 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 60 | M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. |
| 61 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 62 | M & L for preparation of old distempered and painted surfaces including washing, rubbing down and stopping by brooming down , scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of oil distemper emulsion on wall surfaces over one coat of chalk whiting primer over 3 mm thick wall care putty in 2 coats to achieve smooth surfaces complete all as specified and directed. |
| 63 | M & L for preparation of old decorated surface and applying one coat of white wash on Walls complete all as specified and as directed. |
| 64 | M & L for preparation of old plastered surfaces and applying two Coats of cement base paint on Walls complete all as specified and as directed. |
| 65 | M & L for preparation of Old decorated surface and applying two coat of white wash on ceiling complete all as specified and as directed. |
| 66 | M&L for preparation of New Wood surface and applying two coats of synthetic enamel paint over a coat of pink primer over 10cm width or girth complete all as specified and directed. |
| 67 | M&L for preparation of old steel surface over 10cm with or girth. applying two coats of synthetic enamel paint complete all as specified and directed. |
| 68 | S&F steel window or ventilators fixed type with glazing bars complete all as specified and directed. |
| 69 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 70 | S & F 4 mm thick, sheet glass, ordinary quality and glazing with oil putty/timber beads in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 71 | S& F Vitreous china urinal partition white of size 310x700 mm including cutting for and pinning in ends of bracets or erecting stand complete all as specified and directed by engr in charge |
| 72 | S&F Rotational moulded polyethene water storage tanks 1000 lit capacity (cylindrical vertical with closed top) tripple layered hoisted and fixed in position all as specified in SSR part-I including 25mm Ball Valves, 25mm Union, 25mm gate valves, complete all as specified and directed |
| 73 | S&F 20mm outer dia CPVC Pipe (ISI Marked) SDR II & plain CPVC SDR II fittings fixed on wall, celing or laid in floors complete all as specified and directed. |
| 74 | S&F 25mm outer dia CPVC Pipe (ISI Marked) SDR II & plain CPVC SDR II fittings fixed on wall, celing or laid in floors complete all as specified and directed. |
| 75 | S&F Vitreous China Wash hand basin, white flat back size 550x400 mm including brackets, Pillar Tap 15 mm bore Chromium plated fancy type with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts & PVC waste pipe and bedded in cement morter and fixed on CP cantilever brackets complete all as specified & directed |
| 76 | S&F water closet vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe), including connection to trap and flushing pipe, anti-syphonage pipe etc including making good to floor complete all as specified and directed. |
| 77 | S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including making good to disturbed area complete all as specified and directed |
| 78 | S&F 10 ltr capacity PVC Low level flushing cistern including 32mm dia PVC flush pipe, fixing in position with PVC connection pipe of 15mm x 600mm long complete all as specified and directed. |
| 79 | S&F 600mm x 450mm beveled edge mirror of selected quality, glass 5mm thick, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 80 | S&F 15mm Bib taps chromium plated fancy type cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for union complete all as specified and directed |
| 81 | S&F 15mm Bore Stop Valves / Angle Cock Fancy Type Chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends complete all as specified and directed. |
| 82 | S&F Brass chromiun plated tubular towel rail, 20mm dia ‘D’ type, 60CM long between flanges complete all as specified and directed. |
| 83 | S&F CP Soap dish 150mm, fixed to wall with chromium plated brass screws complete all as specified and directed. |
| 84 | M&Lfor PVC (SWR) floor trap 75mm dia plain with steel grating including jointing with solvent cement etc complete complete all as sepcified and directed. |
| 85 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed. |
| 86 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc complete all as specified and directed. |
| 87 | S&F PVC (SWR) bends 110mm dia any radius with access door complete all as specified and directed. |
| 88 | S&F PVC (SWR) bends 75 mm dia any radius with access door complete all as specified and directed. |
| 89 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc), conforming to Fe 410 -W (Gde E- 250) quality-A, complete all as specified and directed. |
| 90 | S&F framed work such as grills, gratings, etc. with ends of bars shoulders and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290, Gde-E-165, complete all as specified and directed. |
| 91 | M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying 2 coats of Synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 92 | S&F pre-painted galvalume aluminium zinc coating (AZ 150) GI based corrugated steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 93 | S&F pre-painted galvalume aluminium zinc coating (AZ 150) GI based plain sheet steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, eaves board fixed with self tapping screws complete as specified and directed. |
| 94 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete all as specified and directed. |
| 95 | M&L for Point wiring for One light/Fan/Bell point controlled by one 5 Amps switch one way switch with 1.5 sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade with multistranded copper conductor conforming to IS-694 1990 with ISI marked (for phase ,neutral and earth) drawn in and including non metalic rigid PVC conduit medium gradewith ISI mark of minimum 20mm dia and all conduit accessories Concealed including cutting / chases in wall /ceiling /fixed to roof /truss/columns etc and including factory made branded make embossed galavanised steel pressed terminal boxes alongwith size modular cover plates with frames fixing modular switches, sockets, regulators etc.of suitable size modules and earth wire to be connected to common earth dolly complete all as specified and directed for the following : Note:Location of light points, socket points and light fittings may be decided by Engr-in-charge as per site/user requirment. |
| 96 | All as per item No 95 above but for One 3 pin socket point 5 Amp on independent board complete all as specified and directed. |
| 97 | All as per item No 95 above but for One 3 pin socket point 5 Amp on same board with other switches complete all as specified and directed. |
| 98 | All as per item No. 95 above but with 2.5sqmm ( Nominal area ) cable with 2.5 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed. |
| 99 | S&F modular switch 1 way 6A,1 module all as specified and directed by Engr-in-charge. |
| 100 | S&F modular switch 1 way 16A,1 module all as specified and directed by Engr-in-charge. |
| 101 | S&F socket, 6A-2/3 pin combined 2 modules all as specified and directed by Engr-in-charge. |
| 102 | S&F socket, 6A/16A-2/3 pin combined 2 modules all as specified and directed by Engr-in-charge. |
| 103 | S&F moduler fan Requlator, 120 W-2 modules all as specified and directed by Engr-in-charge. |
| 104 | S&F switch piano, flush button single pole, 5 Amps one way complete all as specified and directed. |
| 105 | S&F Ceiling rose surface bakelite 65x50mm three terminals including S&F PVC blocks complete all as specified and directed. |
| 106 | S&F in replacement LED tube light fitting of 10 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. |
| 107 | S&F LED tube light fitting of 10 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. |
| 108 | S&F in replacement LED tube light fitting of 20 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as directed by Engr-in-charge. |
| 109 | S&F LED tube light fitting of 20 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as directed by Engr-in-charge. |
| 110 | S&F 40 watt LED Light 4' x 1' LED luminare Surface mounted with polymer diffuser complete with accessories suitable for armstrong/Grid ceiling with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 111 | S&F bldg security light fittings 1x 35 Watt Ac 230v out door type LED street light with high pressure die cast aluminium and heat ressistent complete with driver ,lamp bracket with impact and corrosion resistent including thermal managment in multiple optics complete , IP65/66 and wired with all accessories and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size complete all as specified and directed. |
| 112 | S&F street light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 113 | M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable FRLS conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit fixed on wall with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note : two run of 6.0 sqmm and 01 run of 4.0 sqmm and one run of PVC conduit will be measured as one unit. |
| 114 | S&F in replacement Sheet metal enclosure (ISI marked) distribution board for 415 volts, TPN 4 way Vertical type, double door, Tripal pole and neutral with 200 Amps rated copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as specified and directed. |
| 115 | S&F in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 8 way horizontal type, Double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as specified and directed. |
| 116 | S&F Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 8 way horizontal type, Double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as specified and directed. |
| 117 | S&F in replacement MCB single pole 6 to 32 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified and directed by Engr-in-charge. |
| 118 | S&F MCB single pole 6 to 32 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified and directed by Engr-in-charge. |
| 119 | S&F in repair MCB Tripple pole & neutral 40 to 100 Amps 415 volts, C series,10 kA rupturing capacity providing in DB complete all as specified. |
| 120 | S & F MCB single pole & neutral 32 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified and directed. |
| 121 | S & F in replacement MCB single pole & neutral 40 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified and directed. |
| 122 | Taking down ceiling fan dismantling and painting of ceiling fan complete at site with synthetic enamel paint by spraying incl (fittings with filler) one coat after cleaning all dust etc incl connecting up. Provn of twin core cable of suitable size for ceiling rose to connector connecting of earth wire incl replacement of fan capacitor 2.5/3.15 MFD,canopy, bearing/bush, rubber bushes minor nuts bolts screws washers greassing in fan bearing & refix same complete all as specified and directed |
| 123 | M&L for Rewinding of ceiling fan with appropriate size of copper enamelled wire including varnishing, heating with proper insulation complete and testing complete all as specified and directed. |
| 124 | S & F exhaust fan, single phase, 300 mm (12\\") sweep with blades, frame and Louvers with Metal body,Heavy Duty, 1500 RPM including fixing of mounting frame in the round/square hole cutting in the wall/ventilator etc, by means of rugged bolts, nuts and washers etc,including connecting with three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of the exhaust fan, complete all as specified and directed by Engr-in-charge. |
| 125 | Supply and spread river sand to required width at bottom and top for cable cushioning complete all as specified and directed. |
| 126 | Supply and laying common burnt bricks size(230mmx115mmx75mm/ .230x.115x.075mtrs) bricks of sub class B, laid at right angle on the cable complete in trenches for cable protection complete all as directed by Engr-in-charge. |
| 127 | S&F of 50mm bore dia mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site complete all as specified and directed |
| 128 | S&F of 40mm bore dia mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site complete all as specified and directed |
| 129 | Supply, fixing in replacement, Testing and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade on walls with fixing acessories of 16 sqmm x 4 core complete all as specified and directed. |
| 130 | Supply, fixing, Testing and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade on walls with fixing acessories of 10 sqmm x 4 core complete all as specified and directed. |
| 131 | M&L, Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 4 mm dia by means of of nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender