Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56332980

Tender For Special Repair To Over Head Line Into Under Ground Cable And Connected Work At 73 Armd Regiment Area Under Ge Babina

Issued by Statutory Bodies & Commissions/Committees · Jhansi, Uttar Pradesh
Tender Value
40.77 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
18 days left
EMD
81600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jhansi → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Over Head Line Into Under Ground Cable And Connected Work At 73 Armd Regiment Area Under Ge Babina

BOQ

Name of Work:- Special repair to Over head line into under ground cable and connected work at 73 Armd Regiment area under GE Babina
Sl. No. Item Description
1Dismantling and taking down old existing ACSR or AAC conuctorof any size/type complete all as specified and as directed.
2Dismantling of insulator any size/type complete all as specified and as directed.
3Dismantling of cross arms of MS channel or angle section etc any size/type complete all as specified and as directed.
4Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 185 Sqmm 3.5 core as per IS 7092 Pt -I including suitable size aluminium thimble/lugs for connection of LT cable with panel complete all as specified and directed. Make- Havells, Plaza, Paragon, SCI, KEI
5Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 120Sqmm 3.5 core as per IS 7092 Pt -I including suitable size aluminium thimble/lugs for connection of LT cable with panel complete all as specified and directed. Make- Havells, Plaza, Paragon, SCI, KEI
6Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 70Sqmm 3.5 core as per IS 7092 Pt -I including suitable size aluminium thimble/lugs for connection of LT cable with panel complete all as specified and directed. Make- Havells, Plaza, Paragon, SCI, KEI
7Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 25 Sqmm 4 core as per IS 7092 Pt -I including suitable size aluminium thimble/lugs for connection of LT cable with panel complete all as specified and directed. Make- Havells, Plaza, Paragon, SCI, KEI
8Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 16 Sqmm 4 core as per IS 7092 Pt -I including suitable size aluminium thimble/lugs for connection of LT cable with panel complete all as specified and directed. Make- Havells, Plaza, Paragon, SCI, KEI
9Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 10 Sqmm 4 core as per IS 7092 Pt -I including suitable size aluminium thimble/lugs for connection of LT cable with panel complete all as specified and directed. Make- Havells, Plaza, Paragon, SCI, KEI
10Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for pole / cable / foundation etc including getting out in hard/dense soil complete all as specified and directed.
11Excavation in trenches exc 1.5 mtr wide and n. exc 3.0 mtr depth for pole / cable / foundation etc including getting out in hard/dense soil complete all as specified and directed.
12Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick after cable are laid and tested complete all as specified and directed.
13Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directedat a level not exc. 1.5 mtr above the ground level complete all as specified & directed.
14Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable incl spreading, levelling, watering and consiolidation complete all as specified and directed.
15Supply and laying PCC cable cover of size 250 x150 x 40 mm, laid in trench flat for protection of cable complete all as specified and directed by Engr in charge.
16M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregates) for foundation filling and bed concrete all as specified.
17M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in mass concrete of pole including necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified.
18M&L for PCC 1:2:4 type B-2(using 20mm graded stone aggregates) as in coping etc including form work for poles including taking down of u/s existing HDPE pipes all as specified and directed by Engr-in-Charge.
19Material and labour for Double wall corrugated HDPE pipe,PN-10 ISI marked of outer dia 63mm, inner dia 50 mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-Charge.
20M&L for GI tubing (light grade) with all necessary fittings laid in trenches under road crossing fixed on poles, wall under floor etc. of 80 mm dia bore complete all as specified and directed.
21M&L for GI tubing (light grade) with all necessary fittings laid in trenches under road crossing fixed on poles, wall under floor etc. of 40 mm dia bore complete all as specified and directed.
22Supply and fixing of single phase automatic street light timer switch of capacity 8KW using integrated sensor based NATURE SWITCH for automatic switching of street light based on LUX level of natural light required illuminance for switching on is less than 30Lux and for switching off greater than 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load MCB (s), support terminals should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP 66 degree of ingress three phase 8KW lighting load capacity including mounting bracket, cable glands, openable doors with locking arrangement complete all as specified and as directed. The contactor MCB and circuit wiring should enough to take load of 8KW equally distributed over single phase and street light timer should be comprising of following:-(a) Input MCB rating 63 Amps 230 volst-01 Nos(b) Contactor rating 63 Amps 230 volts- 01 Nos(c) Out put MCB rating 63 Amps 230 vots-01 Nos(d) three phase circuit wiring minimum 16 Sqmm multistranded copper wire.Make: Cat Part No SWADEEP-02EC 8 KW1P, Note :- 01 Year Guarantees+01 year warranty on remaining other item from date of purchase.
23Supply , fix in repairs , commissioning and testing factory made LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated . The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 50x50x5mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement. LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Short Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA.The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following :-Make:- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/s universal switchgear Ltd
24(a) Aluminum bus bar four strips 600 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set.(b) Incoming MCCB, 04 Pole, 400 Amps with ultimate breaking capacity Icu-50 KA at 415 volts, fixed type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%)(c) Outgoing MCCB, 04 Pole, 250 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermal settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%)(d) Outgoing MCCB, 04 Pole, 160 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermal settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 3 Nos (Ics=Icu=100%)(e ) Spare way for 125 Amp, MCCB 4 way-01Nos(f) Digital voltmeter 0-500 Volt with selector switch with MCBs -1 Set(g) Digital Ammeter 0-400 Amps with selector switch with MCBs -1 Set(h) Indication lamps R,Y,B LED type with 3 Nos of 2A MCBs -1 set: (j) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's. Note:- (i) Panel drawing and make of MCCB and connected accessories will be submitted by the contractor for approval of Accepting officer before ordering the panel. (ii) The holes / aprons of cable exit and incoming should be close with suitable size of gland.( iii) The contractor should submit all Certificates before executing the job. (iv) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(v) Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate.
25Supply , fix in repairs , commissioning and testing factory made LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated . The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 50x50x5mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement. LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Short Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA.The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-Make:- M/s Mclayers Bhopal/M/s shalabh(india) Ltd/ M/s universal switchgear Ltd
26(a) Aluminum bus bar four strips 400 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set.(b) Incoming MCCB, 04 Pole, 250 Amps with ultimate breaking capacity Icu-35 KA at 415 volts, fixed type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%)(c) Outgoing MCCB, 04 Pole, 100 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermal settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 04 No (Ics=Icu=100%)(d ) Spare way for 100 Amp, MCCB 4 way-01Nos(e) Digital voltmeter 0-500 Volt -1 Set(f) Digital Ammeter 0-400 Amps -1 Set(g) Indication lamps R,Y,B LED type -1 set: h) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's. Note:- (i) Panel drawing and make of MCCB and connected accessories will be submitted by the contractor for approval of Accepting officer before ordering the panel. (ii) The holes / aprons of cable exit and incoming should be close with suitable size of gland.( iii) The contractor should submit all Certificates before executing the job. (iv) CA No.,Contractor name, item of CA No. to be mentioned on the panel.(v) Suitable Cable glands for incoming cables and outgoing cable to be provided in the panel by the contractors. Cost of provisioning of cable glands deemed to be included in qouted rate.
27M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to galvanised earth lead 32X6mm by means of bolts, nuts, check nuts and washers of galvd iron or steel surronded by charcoal of coke and salt and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 5 of MES schedule Pt I of 2009 and also including making test point for testing of earthing made out of gun metal or phosphorous bronge size 75x75x25 mm complete . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.2. Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit . On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.3. The cost of GI earth lead and GI pipe of 7.50m lenth for protection of GI wire and excavationwork fpr pit shall deemed to be included in this item.
28M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to galvanised earth lead 32X6mm by means of bolts, nuts, check nuts and washers of galvd iron or steel surronded by charcoal of coke and salt and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 5 of MES schedule Pt I of 2009 and also including making test point for testing of earthing made out of gun metal or phosphorous bronge size 75x75x25 mm complete . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.2. Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit . On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.3. The cost of GI earth lead and GI pipe of 7.50m lenth for protection of GI wire and excavationwork fpr pit shall deemed to be included in this item.

AI Tender Summary

OUR REF NO 56332980
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40.77 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Over Head Line Into Under Ground Cable And Connected Work At 73 Armd Regiment Area Under Ge Babina
Basic Detail
Tender No 8549/E8
Bidding Type Tender
Location
City Jhansi
State Uttar Pradesh
Key Dates
Publish Date 06 Jul 2026
Submission Date 27 Jul 2026
Open Date 01 Aug 2026
Finance
Tender Value 40.77 Lakhs
Tender Fee 500
EMD 81600
Exemption Available
Document List
2f995876-04ac-4f5d-b09a-9080bdb9cd2e.html
8549Tenderdoc.pdf
BOQ_869720.xls
Tendernotice_1 (2).pdf
Tender_Acceptance_Letter.pdf
Workdetails.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

2f995876-04ac-4f5d-b09a-9080bdb9cd2e.html

pdf

8549Tenderdoc.pdf

xls

BOQ_869720.xls

pdf

Tendernotice_1 (2).pdf

pdf

Tender_Acceptance_Letter.pdf

pdf

Workdetails.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders