Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #56332971

Tender For Repair / Maintenance To Certain Substations, Lt Distribution System, Capacitor Banks And Other Allied Works At Tp & Non-Tp Area At installation Kalinga, Nad Bheemunipatnam & installation Karna, Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
46.50 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
17 days left
EMD
93000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance To Certain Substations, Lt Distribution System, Capacitor Banks And Other Allied Works At Tp & Non-Tp Area At installation Kalinga, Nad Bheemunipatnam & installation Karna, Visakhapatnam

BOQ

Name of Work:- Repair / Maintenance to Certain Substations, LT Distribution System, Capacitor Banks and Other Allied Works at TP & Non-TP Area at INS Kalinga, NAD Bheemunipatnam & INS Karna, Visakhapatnam
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Soft / Loose soil complete all as specified and as directed.
2Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
3Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
4M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
5Supplying and laying un–reinforced Precast Concrete Cable Cover, Class LV, Type 1, Flat, of size 250mm x 150mm x 40mm complete all as specified and as directed.
6Re-laying serviceable bricks for cable protection complete all as specified and as directed. Note: serviceable bricks obtained during taking down of cable shall be reused.
7M & L for Cutting Bituminous Road / Hardstanding etc. as required for Jointing / Laying Cables and Pipeline of width not exceeding 300mm and depth not exceeding 600mm and refilling after laying and making good with PCC 1:2:4, Type B1 using 20mm graded stone aggregate, 100mm thick complete all as specified and as directed.
8Supplying and laying GI pipe, 50mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete including taking down or up GI Pipe and connections of any description all as specified and as directed.
9Supplying and laying GI pipe, 80mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete including taking down or up GI Pipe and connections of any description all as specified and as directed.
10Re-laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 2 / 3½ / 4 Core, 10 Sq.mm to 70 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
11Re-laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ / 4 Core, 95 Sq.mm to 240 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
12Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 16 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
13Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 10 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
14Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 25 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
15Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 35 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
16Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 50 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
17Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 70 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
18Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 95 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
19Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 120 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
20Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 150 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
21Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 185 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
22Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 240 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
23M & L for Cable Straight Through Joint, Heat Shrinkable, Outdoor type suitable for 1100 Volts Grade, 2/4 Core, 10 to 16 Sq.mm, LT, XLPE Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
24M & L for Cable Straight Through Joint, Heat Shrinkable, Outdoor type suitable for 1100 Volts Grade, 3½/4 Core, 25 to 50 Sq.mm, LT, XLPE Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
25M & L for Cable Straight Through Joint, Heat Shrinkable, Outdoor type suitable for 1100 Volts Grade, 3½/4 Core, 70 to 120 Sq.mm, LT, XLPE Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
26M & L for Cable Straight Through Joint, Heat Shrinkable, Outdoor type suitable for 1100 Volts Grade, 3½/4 Core, 150 to 185 Sq.mm, LT, XLPE Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
27M & L for Cable Straight Through Joint, Heat Shrinkable, Outdoor type suitable for 1100 Volts Grade, 3½/4 Core, 240 to 300 Sq.mm, LT, XLPE Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
28S & F in repairs MCCB, FP, 400 Amps, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
29S & F in repairs MCCB, FP, 250 Amps, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
30S & F in repairs MCCB, FP, 200 Amps, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
31S & F in repairs MCCB, FP, 125 Amps, 25 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
32S & F in repairs MCCB, FP, 63 Amps, 25 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
33S & F in repairs and Testing Digital Ampere Meters of Range 0 – 500 Amps, 415 Volts with inbuilt Selector Switch, Accuracy Class – 1, Flush Pattern, Square Type, Flush Mounted including wiring complete all as specified and as directed. Make: Havells / L & T / AE / Schneider / BCH
34S & F in repairs and Testing Digital Volt Meters of Range 0 – 500 Volts, 415 Volts with inbuilt Selector Switch, Accuracy Class – 1, Flush Pattern, Square Type, Flush Mounted including wiring complete all as specified and as directed. Make: Havells / L & T / AE / Schneider / BCH
35S & F in repairs of CT's, Epoxy Cast Resin with Primary Current of 400 Amps – 650 Amps or as per existing Panel ratings suitable for Relays and Secondary Current of 5 Amps, Dual Core, Dual Ratio. Protection Core – Class 5P10 & Metering Core – Class 0.5, 2.5 VA. Suitable for LT, 415V Panel incoming feeders complete all as specified and as directed.
36S & F in repairs and Testing Aluminium Lugs, suitable for 240 Sq.mm LT UG XLPE Aluminium Conductor Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
37S & F in repairs and Testing Aluminium Lugs, suitable for 185 Sq.mm LT UG XLPE Aluminium Conductor Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
38S & F in repairs and Testing Aluminium Lugs, suitable for 120 Sq.mm LT UG XLPE Aluminium Conductor Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
39S & F in repairs and Testing Aluminium Lugs, suitable for 95 Sq.mm LT UG XLPE Aluminium Conductor Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
40S & F in repairs and Testing Aluminium Lugs, suitable for 70 Sq.mm LT UG XLPE Aluminium Conductor Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
41S & F in repairs and Testing Aluminium Lugs, suitable for 50 Sq.mm LT UG XLPE Aluminium Conductor Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
42S & F in repairs and Testing Aluminium Lugs, suitable for 25 Sq.mm LT UG XLPE Aluminium Conductor Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
43S & F in repairs and Testing Aluminium Lugs, suitable for 16 Sq.mm LT UG XLPE Aluminium Conductor Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
44M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
45S & F On-Load Changeover Switch, FP, 630 Amps, 50 KA, 415 Volts, 50 Hz, AC, I – O – II Operation, Manual type, Front Operated Handle, Adjustable type of Thermal & Magnetic Setting in Sheet Steel Enclosure made of 2mm thick CRCA Sheet, with Advance Neutral and conforming to IS - 13947 [Part - 3] & IEC: 60947-3 including taking down old Change Over Switch of any description complete all as specified and as directed.
46S & F On-Load Changeover Switch, FP, 400 Amps, 50 KA, 415 Volts, 50 Hz, AC, I – O – II Operation, Manual type, Front Operated Handle, Adjustable type of Thermal & Magnetic Setting in Sheet Steel Enclosure made of 2mm thick CRCA Sheet, with Advance Neutral and conforming to IS - 13947 [Part - 3] & IEC: 60947-3 including taking down old Change Over Switch of any description complete all as specified and as directed.
47S & F On-Load Changeover Switch, FP, 250 Amps, 50 KA, 415 Volts, 50 Hz, AC, I – O – II Operation, Manual type, Front Operated Handle, Adjustable type of Thermal & Magnetic Setting in Sheet Steel Enclosure made of 2mm thick CRCA Sheet, with Advance Neutral and conforming to IS - 13947 [Part - 3] & IEC: 60947-3 including taking down old Change Over Switch of any description complete all as specified and as directed.
48S & F On-Load Changeover Switch, FP, 100/125 Amps, 50 KA, 415 Volts, 50 Hz, AC, I – O – II Operation, Manual type, Front Operated Handle, Adjustable type of Thermal & Magnetic Setting in Sheet Steel Enclosure made of 2mm thick CRCA Sheet, with Advance Neutral and conforming to IS - 13947 [Part - 3] & IEC: 60947-3 including taking down old Change Over Switch of any description complete all as specified and as directed. Please Enable Macros to View BoQ information
49S & F On-Load Changeover Switch, FP, 100/125 Amps, 50 KA, 415 Volts, 50 Hz, AC, I – O – II Operation, Manual type, Front Operated Handle, Adjustable type of Thermal & Magnetic Setting in Sheet Steel Enclosure made of 2mm thick CRCA Sheet, with Advance Neutral and conforming to IS - 13947 [Part - 3] & IEC: 60947-3 including taking down old Change Over Switch of any description complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56332971
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46.50 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance To Certain Substations, Lt Distribution System, Capacitor Banks And Other Allied Works At Tp & Non-Tp Area At installation Kalinga, Nad Bheemunipatnam & installation Karna, Visakhapatnam
Basic Detail
Tender No 8271 / E8
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 06 Jul 2026
Submission Date 27 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value 46.50 Lakhs
Tender Fee 500
EMD 93000
Exemption Available
Document List
62288e2a-9cbe-4652-98e2-0d3d8f5ef996.html
8271Tender.pdf
BOQ_869749.xls
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

62288e2a-9cbe-4652-98e2-0d3d8f5ef996.html

pdf

8271Tender.pdf

xls

BOQ_869749.xls

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders