Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56332940

Tender For Repair / Maintenance Of Apfc Panels, Capacitor Banks And Connected Accessories And Other Allied Works And Outdoor Lt Panels And Connected Accessories And Other Allied Works At installation Kalinga, installation Karna And Nad Bheemunipatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
42.50 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
15 days left
EMD
85000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Apfc Panels, Capacitor Banks And Connected Accessories And Other Allied Works And Outdoor Lt Panels And Connected Accessories And Other Allied Works At installation Kalinga, installation Karna And Nad Bheemunipatnam, Visakhapatnam

BOQ

Name of Work:- Repair / Maintenance of APFC Panels, Capacitor Banks and Connected Accessories and Other Allied Works and Outdoor LT Panels and Connected Accessories and Other Allied Works at INS Kalinga, INS Karna and NAD Bheemunipatnam, Visakhapatnam
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Soft / Loose soil complete all as specified and as directed.
2Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
3Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
4M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
5Supplying and laying un–reinforced Precast Concrete Cable Cover, Class LV, Type 1, Flat, of size 250mm x 150mm x 40mm complete all as specified and as directed.
6M & L for Cutting Bituminous Road / Hardstanding etc. as required for Jointing / Laying Cables and Pipeline of width not exceeding 300mm and depth not exceeding 600mm and refilling after laying and making good with PCC 1:2:4, Type B1 using 20mm graded stone aggregate, 100mm thick complete all as specified and as directed.
7Supplying and laying in repairs GI pipe, 50mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete including taking down or up GI Pipe and connections of any description all as specified and as directed.
8Supplying and laying in repairs GI pipe, 80mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete including taking down or up GI Pipe and connections of any description all as specified and as directed.
9Supplying and laying in repairs GI pipe, 100mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete including taking down or up GI Pipe and connections of any description all as specified and as directed.
10Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 16 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
11Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 50 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
12Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 70 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
13Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 95 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
14Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 120 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
15Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 185 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
16M & L for Cable Straight Through Joint, Heat Shrinkable, Outdoor type suitable for 1100 Volts Grade, 2/4 Core, 10 to 16 Sq.mm, LT, XLPE Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
17M & L for Cable Straight Through Joint, Heat Shrinkable, Outdoor type suitable for 1100 Volts Grade, 3½/4 Core, 25 to 50 Sq.mm, LT, XLPE Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
18M & L for Cable Straight Through Joint, Heat Shrinkable, Outdoor type suitable for 1100 Volts Grade, 3½/4 Core, 70 to 120 Sq.mm, LT, XLPE Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
19M & L for Cable Straight Through Joint, Heat Shrinkable, Outdoor type suitable for 1100 Volts Grade, 3½/4 Core, 150 to 185 Sq.mm, LT, XLPE Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
20M & L for Cable Straight Through Joint, Heat Shrinkable, Outdoor type suitable for 1100 Volts Grade, 3½/4 Core, 240 to 400 Sq.mm, LT, XLPE Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
21S & F in repairs MCCB, FP, 400 Amps, 50 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
22S & F in repairs MCCB, FP, 250 Amps, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
23S & F in repairs MCCB, FP, 200 Amps, 25 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
24S & F in repairs MCCB, FP, 125 Amps, 25 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
25S & F in repairs MCCB, FP, 63 Amps, 25 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
26S & F in repairs MCCB, TP, 400 Amps, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
27S & F in repairs MCCB, TP, 250 Amps, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
28S & F in repairs MCCB, TP, 200 Amps, 25 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
29S & F in repairs MCCB, TP, 125 Amps, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
30S & F in repairs MCCB, TP, 63 Amps, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
31S & F in repairs MCCB, TP, 25 Amps, 25 KA, 415 Volts, 3 Phase, AC, 50 Hz, Ics = 100% Icu, Thermal Adjustable – 0.8 to 1 In complete with Thermal Magnetic Protection Unit complete all as specified and as directed.
32S & F in repairs and Testing Digital Ampere Meters of Range 0 – 500 Amps with inbuilt Selector Switch, Accuracy Class – 1, Flush Pattern, Square Type, 415 Volts including wiring complete all as specified and as directed. Make: Havells / L & T / AE / Schneider / BCH
33S & F in repairs and Testing Digital Volt Meters of Range 0 – 500 Volts with inbuilt Selector Switch, Accuracy Class – 1, Flush Pattern, Square Type,415 Volts including wiring complete all as specified and as directed. Make: Havells / L & T / AE / Schneider / BCH
34S & F in repairs and Testing Digital Power Factor Meters with inbuilt Selector Switch, Accuracy Class – 1, Flush Pattern, Square Type, 415 Volts including wiring complete all as specified and as directed. Make: Havells / L & T / AE / Schneider / BCH
35S & F in repairs Resin Cast Wound / Ring Type CT 400A / 5A Class 1.0 in 433 Volts, in existing LT Panel Boards complete as specified and as directed. Make: AE / IMP / MECO / MEI / HPL / Crompton
36S & F in repairs Rotating Phase Selector Switch for Voltmeter and Ammeter complete as specified and as directed. Make: C & S / HPL / AE / L & T
37S & F in repairs and Testing Copper Lugs, suitable for 2.5 Sq.mm Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
38S & F in repairs and Testing Copper Lugs, suitable for 6 Sq.mm Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
39S & F in repairs and Testing Copper Lugs, suitable for 16 Sq.mm Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
40S & F in repairs and Testing Copper Lugs, Heavy Duty suitable for 25 Sq.mm Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
41S & F in repairs and Testing Copper Lugs, suitable for 35 Sq.mm Cable including Nuts, Bolts and Washers complete all as specified and as directed. Make: Sona Cable Sockets / Swastic / Dowells
42S & F in repairs and Testing Control Wiring with 1 Core, 2.5 Sq.mm, Copper Cable including suitable Ferrules & Lugs complete all as specified and as directed. Make: Havells / Finolex / Nicco / KEI / Polycab / RR Kabel Ltd / Gloster
43S & F in repairs and Testing Control Wiring with 1 Core, 6 Sq.mm, Copper Cable including suitable Ferrules & Lugs complete all as specified and as directed. Make: Havells / Finolex / Nicco / KEI / Polycab / RR Kabel Ltd / Gloster
44S & F in repairs and Testing Control Wiring with 1 Core, 16 Sq.mm, Copper Cable including suitable Ferrules & Lugs complete all as specified and as directed. Make: Havells / Finolex / Nicco / KEI / Polycab / RR Kabel Ltd / Gloster
45S & F in repairs and Testing Control Wiring 1 Core, 25 Sq.mm, Copper Cable including suitable Ferrules & Lugs complete all as specified and as directed. Make: Havells / Finolex / Nicco / KEI / Polycab / RR Kabel Ltd / Gloster
46S & F in repairs and Testing Control Wiring 1 Core, 35 Sq.mm, Copper Cable including suitable Ferrules & Lugs complete all as specified and as directed. Make: Havells / Finolex / Nicco / KEI / Polycab / RR Kabel Ltd / Gloster
47M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
48M & L for taking out the loose or separated Door / Canopy / Front & Back Sheet covers from existing LT Panel and refixing the same after welding, provision of Nut / Bolts / Hinges if required as per site, proper Locking Arrangement and fixing of proper earth connection etc. complete all as specified and as directed.
49M & L for painting of LT Panels at site by applying Two coats of Synthetic Enamel Paint [Grey Tint] [Paint shall confirm to IS – 2032] after removing all Dust & Rust including preparation of surfaces complete all as specified and as directed.
50Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 600 Amps rating TPN bus bars of high conductivity Aluminium Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 75 X 75 X 8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and disconnecting and taking down existing LT Panel of any description and comprising the following:
51[a] MCCB, 400 Amps, FP, 36 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Incoming][b] MCCB, 100 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 3 Nos [Outgoing][c] MCCB, 63 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Outgoing][d] MCCB, 32 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 2 Nos [Outgoing][e] On-Load Changeover Switch, FP, 400 Amps, 415 Volts, 50 Hz, AC, Front Operated Handle with Advance Neutral – 1 Nos[f] Multi Function Meter, Digital Type [Displaying A, V, Hz, Kw etc. Class 0.5] with CTs & Selector Switch – 4 Nos [1 Set].[g] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set.
52Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 600 Amps rating TPN bus bars of high conductivity Aluminium Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 75 X 75 X 8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and disconnecting and taking down existing LT Panel of any description and comprising the following:
53[a] MCCB, 250 Amps, FP, 36 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Incoming][b] MCCB, 100 Amps, FP, 25 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Outgoing][c] MCCB, 63 Amps, FP, 25 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 5 Nos [Outgoing][d] MCCB, 32 Amps, FP, 25 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Outgoing][e] On-Load Changeover Switch, FP, 400 Amps, 415 Volts, 50 Hz, AC, Front Operated Handle with Advance Neutral – 1 Nos[f] Multi Function Meter, Digital Type [Displaying A, V, Hz, Kw etc. Class 0.5] with CTs & Selector Switch – 4 Nos [1 Set].[g] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set.
54Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 600 Amps rating TPN bus bars of high conductivity Aluminium Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 75 X 75 X 8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and disconnecting and taking down existing LT Panel of any description and comprising the following:
55[a] MCCB, 250 Amps, FP, 36 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Incoming][b] MCCB, 100 Amps, FP, 36 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 2 Nos [Outgoing][c] MCCB, 63 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Outgoing] [d] MCCB, 125 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Outgoing] [Spare][e] Multi Function Meter, Digital Type [Displaying A, V, Hz, Kw etc. Class 0.5] with CTs & Selector Switch – 4 Nos [1 Set].[f] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set.
56Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 500 Amps rating TPN bus bars of high conductivity Aluminium Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 10KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 75 X 75 X 8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and disconnecting and taking down existing LT Panel of any description and comprising the following:
57[a] MCCB, 250Amps, FP, 36 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Incoming][b] MCCB, 100 Amps, FP, 25 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 2 Nos [Outgoing][c] MCCB, 63 Amps, FP, 25 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 2 Nos [Outgoing][d] MCCB, 32 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Outgoing][e] Multi Function Meter, Digital Type [Displaying A, V, Hz, Kw etc. Class 0.5] with CTs & Selector Switch – 4 Nos [1 Set].[f] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set.
58Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 500 Amps rating TPN bus bars of high conductivity Aluminium Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 10KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 75 X 75 X 8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and disconnecting and taking down existing LT Panel of any description and comprising the following:
59[a] MCCB, 400 Amps, FP, 36 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Incoming][b] MCCB, 250 Amps, FP, 25 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 2 Nos [Outgoing][c] MCCB, 100 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Outgoing][d] On-Load Changeover Switch, FP, 160 Amps, 415 Volts, 50 Hz, AC, Front Operated Handle with Advance Neutral – 1 Nos[e] Multi Function Meter, Digital Type [Displaying A, V, Hz, Kw etc. Class 0.5] with CTs & Selector Switch – 4 Nos [1 Set].[f] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set.
60Supply, Install, Testing & Commissioning including taking down of Busbar Chamber of Capacity 400 Amps, TPN with Copper Busbar with IP 54 Protection for Safe Power Distribution Board with all connected fittings and fixtures including Internal Connections and fixed on raised PCC Platform made of PCC 1:2:4, type B1, using 20 mm graded aggregate complete all as specified and as directed. Make: Indo Asian Cat No. CPPI1021 or any CPRI approved manufacturer.
61Taking Down LT Panel / Distribution Boxes of any type, any size and any capacity from their existing place and further disposal complete all as specified and as directed.
62Taking Down LT Panel of any description from their existing location and refixing the same in other place including making good the disturbed surface to match with the existing complete all as specified and as directed. Note: Connecting item like Cables, Lugs, Joints shall be measured and paid separately under respective Items of this Schedule.
63Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 600 Amps rating TPN bus bars of high conductivity Aluminium Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 75 X 75 X 8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and disconnecting and taking down existing LT Panel of any description and comprising the following:
64[a] MCCB, 400 Amps, FP, 36 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 Nos [Outgoing][b] MCCB, 200 Amps, FP, 25 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 2 Nos [Outgoing][c] MCCB, 100 Amps, FP, 25 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 2 Nos [Outgoing][d] Multi Function Meter, Digital Type [Displaying A, V, Hz, Kw etc. Class 0.5] with CTs & Selector Switch – 4 Nos [1 Set].[e] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set.
65S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
66S & F in repairs Aluminium Conductor, Steel Reinforced for Two Pole Structure / Overhead Stretching, fixing and binding with 14 SWG Aluminium wire to Cross Arms, Insulators, Jumper complete all as specified and as directed.
67M & L for Calibration, Testing & Commissioning of APFC Panel, Microprocessor Based Automatic Power Factor Controller of any capacity with Aux Supply of 100 – 440 Volts, AC, 50 Hz, CT input range of 1 Amps / 5 Amps, Voltage input Range of 100 – 600 Volts, 50 Hz, Minimum 8 Analog Outputs and consisting of following Salient Features including replacement of all the Fittings and Fixtures as per OEM for smooth and efficient operation complete all as specified and as directed:[a] 3 CT Input for Current & Voltage Measurement[b] Provision for Dual PF Settings for Mains & DG Application[c] Manual & Automatic Operation [d] Accuracy of +0.8% for Reactive Power, +0.5% for Current, 6 or 12 Steps to operate Capacitor Circuits.[e] 2 & 4 Quadrant Operation for Sites with / without Solar Plants[f] Option of LIFO, FIFO & Intelligent Control Mode to choose the best combination of Capacitor Bank for compensation with minimum switching to achieve the desired Power Factor[g] Power Quality Information such as Total & Individual I-THD & V-THD up to 31st Order[h] Current & Voltage Angles displayed for ease of Troubleshooting[i] PF Display – 3 Steps after Decimal[j] Capacitor Health Check Monitoring[k] Record of Capacitor Step Switching for scheduling of maintenance of Panel[l] Ambient Temperature Monitoring[m] Timestamping of latest 32 Alarms Controller with LCD display.Make of APFC Panel : L & T etaSMART / C & S / ABB / Schnieder / Siemens / EPCOS
68S & F in repairs Power Factor Correction [PFC] Capacitors of Rating 10 KVAR, 440 Volts, 50 Hz, 3 Phase Capacitor of any type [Cylindrical / Rectangular] designed for High-Voltage On-Load Tap-Changer [OLTC] applications with Low Energy Consumption, Capable of withstanding High Inrush Current, Dry-type, Free from Oil Leakage, Explosion Proof Feature, Compact size and light weight complete all as specified and as directed. Make: L & T / Havells / Epcos / Schneider / ABB
69S & F in repairs Power Factor Correction [PFC] Capacitors of Rating 12.5 KVAR, 440 Volts, 50 Hz, 3 Phase Capacitor of any type [Cylindrical / Rectangular] designed for High-Voltage On-Load Tap-Changer [OLTC] applications with Low Energy Consumption, Capable of withstanding High Inrush Current, Dry-type, Free from Oil Leakage, Explosion Proof Feature, Compact size and light weight complete all as specified and as directed. Make: L & T / Havells / Epcos / Schneider / ABB
70S & F in repairs Power Factor Correction [PFC] Capacitors of Rating 25 KVAR, 440 Volts, 50 Hz, 3 Phase Capacitor of any type [Cylindrical / Rectangular] designed for High-Voltage On-Load Tap-Changer [OLTC] applications with Low Energy Consumption, Capable of withstanding High Inrush Current, Dry-type, Free from Oil Leakage, Explosion Proof Feature, Compact size and light weight complete all as specified and as directed. Make: L & T / Havells / Epcos / Schneider / ABB
71S & F in repairs Power Factor Correction [PFC] Capacitors of Rating 50 KVAR, 440 Volts, 50 Hz, 3 Phase Capacitor of any type [Cylindrical / Rectangular] designed for High-Voltage On-Load Tap-Changer [OLTC] applications with Low Energy Consumption, Capable of withstanding High Inrush Current, Dry-type, Free from Oil Leakage, Explosion Proof Feature, Compact size and light weight complete all as specified and as directed. Make: L & T / Havells / Epcos / Schneider / ABB
72S & F in repairs Auto / Manual Selector Switch and Control Wiring with 1 Core, 2.5 Sq.mm Copper Cable with proper Ferules & appropriate Lugs complete all as specified and as directed.
73S & F in repairs Start / Stop Selector Switch and Control Wiring with 1 Core, 2.5 Sq.mm Copper Cable with suitable Ferules & Lugs complete all as specified and as directed.
74S & F in repairs 3 Pole Power Contactor, 25 Amps, TP 1NO+1NC, 220 Volts, AC with Add-on Blocks, Conforming to IS/IEC 60947-4-1 & IEC 60947-4-1 complete all as specified and as directed. Make: GE / L & T / Havells / Indoasian / Schneider / ABB
75S & F in repairs 3 Pole Power Contactor, 50 Amps, TP 1NO+1NC, 220 Volts, AC with Add-on Blocks, Conforming to IS/IEC 60947-4-1 & IEC 60947-4-1 complete all as specified and as directed. Make: GE / L & T / Havells / Indoasian / Schneider / ABB
76S & F in repairs 3 Pole Power Contactor, 110 Amps, TP 1NO+1NC, 220 Volts, AC with Add-on Blocks, Conforming to IS/IEC 60947-4-1 & IEC 60947-4-1 complete all as specified and as directed. Make: GE / L & T / Havells / Indoasian / Schneider / ABB
77S & F in repairs Indication Lamp, 230 Volts, AC, LED type, of Colour Red, Yellow, Blue, Green, White, Amber complete all as specified and as directed. Make: Kaycee / Technik / L & T
78Supply, Install, Testing & Commissioning of CT with Primary Current 30 Amps – 120 Amps or as per existing Panel Ratings, Class of Accuracy, Class 1 up to 5 VA, including disconnecting old U/S Meter, removing from Busbar, fixing new CT to Busbar with suitable clearance, Secondary Wiring with FRLS insulated Copper Conductor and Lugs of suitable size complete all as specified and as directed. Make: Alsthom / Crompton Greaves / Kappa / AE / Siemens
79S & F in repairs HT Danger Notice Plate of 250 mm X 200 mm, made of Mild Steel, at least 1.6 mm thick, and Vitreous Enamelled White on both sides, and with inscription with Letters, Figures and Conventional Skull and Bones in Signal Red Colour on Front Side as required and fixed with M.S. Clamps, Bolts and Nuts of approved size complete all as specified and as directed.
80M & L for 2mm thick Fibre Reinforced Plastic Coating with Epoxy Paint of approved colour on the surfaces of Panel Boards, RMUs including preparation of existing surfaces thoroughly complete all as specified and as directed.
81M & L for Decarburizing / Cleaning complete 1.1 KV, 415 Volts, 3 Phase, LT Panel / Busbar Chamber of size not less than 1700 X 1500 X 500mm with electrical connections, complete busbar from the busbar chamber, Cleaning with CTC to ensure proper decarburizing up to proper megger value, refixing the same after applying Backtol Red solution to the Busbar Insulator, applying Backtol Red Paint for both Busbar Spouts, Circuit Spouts, checking all connections, tightening the Nuts, Bolts, Thimbles of In-Coming / Out-Going System complete including replacement of defective Rusted GI Bolts & Nuts, Washers, Checknuts etc. complete all as specified and as directed.
82Supplying, Installing, Commissioning and Testing CPRI Prototype Tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof, Compartmentalised, Indoor type, Automatic Power Factor Correction [APFC] Panel comprising of Low Loss MD-XL Heavy Duty Hermetically Sealed Capacitor Bank of 60 KVAR, connected in 4 Steps with Capacitor rating [2 X 5 + 2 X 25] KVAR complete with Step Contactor suitable for Capacitor switching with HRC Fuses, Backup Protection, APFC Relay 10 Stage Microprocessor based combinational switching type, fabricated with 2mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces with minimum IP 43 Ingress Protection suitable for 3 Phase, 415 V & 50 Hz System with MD-XL Capacitor including suitable rated TPN, MCCB, 415 V, 35 KA rupturing capacity as incomer duly controlled by Auto and Manual option including instrumentation such as Digital Power Factor Meter – 1 Nos, Digital type Ammeter of Range 0 to 300 Amps with CTs & Selector Switch – 1 Nos, Digital type Volt Meter of Range 0 – 500 V – 1 Nos, Relay, Auxiliary Contacts, CTS, Phase Indicating LED Lamps [RYB], Selector switches etc., suitable internal wiring with copper cable of suitable size, double stud hinged door, front openable with locking arrangement including interlocking with switch gears complete and panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level including connecting up with existing incoming and outgoing cables etc. complete all as specified and as directed and comprising following items and of make Legrand / L & T / Siemens / Neptune as approved by GE:
83Incoming:[a] MCCB, 160 Amps, 4 Pole, 25 KA with thermal magnetic release with rotary handle & 400 Amps rating TPN bus bars of high conductivity Aluminium Alloy[b] CBCT[c] Earth Leakage Relay[d] Over Voltage and Under Voltage Relay[e] Phase Indicating LED Lamps. [RYB][f] Control Fuse Base with 2 Amps HRC Link[g] 4 Stage APFC Relay[h] Timer[i] Aux Contractor[j] Exhaust FanOutgoing:[a][2 X 5 + 2 X 25] Capacitor Bank - 2 Nos[b] Blank[c] Suitable KVAR MPP Heavy Duty Capacitor Cylinder Type, 415 Volts.[d] Suitable KVAR Capacitor duty contractor[e] Indicating LED Lamp. [ON/OFF][f] Push Button. [Start/ Stop][g] Control Fuse Base with 2 Amps HRC Link. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56332940
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.50 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Apfc Panels, Capacitor Banks And Connected Accessories And Other Allied Works And Outdoor Lt Panels And Connected Accessories And Other Allied Works At installation Kalinga, installation Karna And Nad Bheemunipatnam, Visakhapatnam
Basic Detail
Tender No 8272 / E8
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 06 Jul 2026
Submission Date 27 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value 42.50 Lakhs
Tender Fee 500
EMD 85000
Exemption Available
Document List
8272Tender.pdf
b315fdff-f7a9-4cb7-9c3c-c2131009c38f.html
BOQ_869755.xls
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
pdf

8272Tender.pdf

html

b315fdff-f7a9-4cb7-9c3c-c2131009c38f.html

xls

BOQ_869755.xls

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender