Public Administrative Department Local Bodies Closing in 4 days TDR #56332740

Tender For Provision Of Lighting Arrangement And Other Allied Work In Ward No. 215 Under Shahdara South Zone.

Issued by Local Bodies · Delhi, Delhi
Tender Value
4.76 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
4 days left
EMD
10000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Lighting Arrangement And Other Allied Work In Ward No. 215 Under Shahdara South Zone.

BOQ

Name of Work:- Provision of lighting arrangement and other allied work in ward no. 215 under Shahdara South Zone.
Sl. No. Item Description
1Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable Gi box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
2Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit as required.2 X 2.5 sq. mm 1X2.5 sq. mm earth wire
3Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole and neutral
4Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
5Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, power painted including earthing etc. as requird (but without MCBIRCCB/Isolator 8 way, Double door.
6Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
7Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required on wall surface as required
8Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required
9Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/coke and salt) as required
10Providing and laying earth connection from earth electrode with 6 SWG dia G.l. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.l. thimble excavation and re-filling as required.
11Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
12Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of Insulation: 8, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
13Supplying , Installation, Testing and Commissioning of Window typeAir conditioners complete with copper power cable upto 3 Mtr,wireless Remote, suitable for working between 180- 260V with low &high voltage cutoff and 50 hz ,1 phase AC supply capable ofperforming, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 yearOriginal Equipment Manufacturer (OEM) warranty both compressorand Printed Circuit Board (PCB), antifreeze thermostat on the coil asa safety feature, complete with fixing including T&P &labouretc asrequired complete in all respect as specified of following capacity.Sound level of up to 50dB inside the room is acceptable. The unit shallbe in confirmation with IS 1391 Part-I 2023 and CPWD Specification.The system shall be able to deliver 100% of the rated capacity upto 42°C. The system shall be able to operate up to 50 °C (out door ambienttemperature).
14SITC of 30W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as read with IP 66 protection (a) Total system wattage 30 watt +/-5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class-IP-66
15Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
16Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required. Upto 450 mm sweep
17Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per 15: 10322 with Idriver (Replaceable) as per the requirement with Driver efficiency >85% operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD 10%, P. F.20.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K/4000K/5700K/6000K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name ngraved/Embossing/Screen printing on housing, complete in all respect i/c mark certificate (T.C Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing, complete in all respect i/c connections with 1.5 sq mim FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/Extruded aluminium Body (Thickness a 1.20 mm)18-22 Watt
18SITC of LED tube type luminary 10 watt rating complete with poly carbonate housing batten integrated electronics driver pre-wired with high efficient LEDs with following a) Total system wattage 10 watt +/-5% Im b) Efficiency lumens/watt >=95, c) Power factor >=,95
19SITC of single phase monoblock pump set complete with all accessories workable on 240/415V,50HZ ac supply(a) 1HP(0.75KW)single phase pump set head from 12-30 meter suction and delivery 25*25mm
20SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color
21Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand)at all level
22Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources 4 graded stone aggregate 20 mm nominal size derived from natural sources
23Supply of illuminated signage Board made of 3 mm thick ACP sheet on MS Pipe frame of 1\\" ACP Sheet CNC cut as per requirement & Bakelite with 3 mm acrylic from back covered with GI Sheet, Led module suitable led with 2 year warranty & suitable adopter with 1 year warranty Size of Board (15.5 x5)'
24Supply of C Channel 40x75x40 required for fixing of illuminated signage board etc complete as regd.
25Supply, instalianon, testing and commissioning of 50mmx50mmx5mm angle von mounting stand for ACP sign board and painting with primer and finished paint as required
26Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to 15-7098 of following size -3x6 sqmm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56332740
AUTHORITY Local Bodies
TENDER VALUE 4.76 Lakhs
LAST DATE 13-07-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Provision Of Lighting Arrangement And Other Allied Work In Ward No. 215 Under Shahdara South Zone.
Basic Detail
Tender No EEE-II/2026-27/12.2
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 06 Jul 2026
Submission Date 13 Jul 2026
Open Date 13 Jul 2026
Finance
Tender Value 4.76 Lakhs
Tender Fee 590
EMD 10000
Exemption Not Available
Document List
BOQ_330321.xls
c12d903f-22b7-4d32-826b-dbc1be87113f.html
Circular.pdf
condition2.pdf
Tendernotice_1 (2).pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Jul 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_330321.xls

html

c12d903f-22b7-4d32-826b-dbc1be87113f.html

pdf

Circular.pdf

pdf

condition2.pdf

pdf

Tendernotice_1 (2).pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders