Science and Technology Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56332730

Tender For Providing And Fixing Partition For Accommodating Sophisticated Analytical Equipment In Room No.Mb-001 At Ground Floor Of Main Building And Gas Shed For Nmr Facility At Caters Division, Csir-Clri, Adyar, Chennai - 600020

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
20.95 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
18 days left
EMD
41900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing And Fixing Partition For Accommodating Sophisticated Analytical Equipment In Room No.Mb-001 At Ground Floor Of Main Building And Gas Shed For Nmr Facility At Caters Division, Csir-Clri, Adyar, Chennai - 600020

BOQ

Name of Work:- Providing and Fixing Partition for Accommodating Sophisticated Analytical Equipment in Room No.MB-001 at Ground Floor of Main Building and GAS Shed for NMR Facility at CATERS Division, CSIR-CLRI, Adyar, Chennai - 600020
Sl. No. Item Description
1Civil Items
2EARTH WORKEarth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lif upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
4CEMENT CONCRETE (CAST IN SITU)Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5MASONRY WORKBrick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6(1 cement :6 coarse sand)
6WOOD AND P. V. C. WORKProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
7Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378)300x16 mm
8Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378)250x10 mm
9Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
10Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
11Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
12Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
13Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
14Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 2nd class teak wood beading 62X19 mm
15Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speedsCasement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre).
16Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m).
17STEEL WORKStructural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
18FLOORINGCement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
19ROOFINGProviding and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like difusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
20FINISHING15 mm cement plaster on the rough side of single or half brick wall of mix:1:6 (1 cement: 6 fine sand)
21Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
22Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
23Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
24Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
25Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
26REPAIRS TO BUILDINGRenewing glass panes, with wooden fillets wherever necessary:Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm)
27Dismantling and DemolishingDemolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
28Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
29Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area beyond 3 sq. metres
30ROAD WORKProviding and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer- in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
31Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
32DRAINAGERaising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Raising depth of manhole to be paid separately) :Rectangular manhole 120x90 cm with circular cover 500 mm dia of grade MD - 10
33ALUMINIUM WORKProviding and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
34Powder coated aluminium (minimum thickness of powder coating 50 micron)
35Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge:With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) [Rate including 3m glass stickering]
36Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/ structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600Upto 10 mm depth and 10 mm width
37NEW TECHNOLOGIES AND MATERIALSProviding and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 65 x 100 mm
38Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: Including stainless steel butt hinges cutting for glass and necessary S.S screws etc)30 mm thick
39Providing, supplying and fixing factory made insulated PUF sandwich roof panels consisting of 0.40 mm thick pre-coated profiled outer steel sheet and 0.40 mm thick pre-coated inner liner sheet of minimum 240 MPa yield strength with AZ120 Al-Zn coating, overall insulation thickness 30 mm plus 35 mm trapezoidal profile, filled with CFC-free, self-extinguishing rigid Polyurethane Foam insulation of density 40 ±2 kg/m³, in approved shade (Sky Blue/Off White), including self-drilling/self-tapping fasteners, corroshield stitching screws, sealant tapes, ridge flashing, barge flashing, end closures, laps and weatherproofing arrangements, PU/Silicon sealent putty for exposed corner sponge/Foam area throughout the lenght of 50mm wide , sealing joint between wall and puff panel etc complete for watertight roofing system as per approved drawings and manufacturer’s recommendations. Panels shall be designed and fixed to withstand wind uplift loads as per IS 875 (Part-3). The roofing system shall be handed over completely watertight, and rectification of any leakage occurring during defect liability period shall be carried out by the contractor at no additional cost. Rates quoted shall be inclusive of all labour, scaffolding, staging, lifting arrangements, safety measures, temporary supports, tools, tackles and access equipment required for execution at all heights and locations. Roofing and cladding area shall be measured on slope area basis only and no extra payment shall be made for laps, overlaps, cut-outs, corner PU/silicon sealent putty and wastage.30mm Puff Panel: Make: Kingspan Jindal / BNAL / Metecno/TATA or equivalent approved.[ Note: profiled polycarbonate skylight sheets area measurement will be deduct from the puff panel area for payment]
40Providing and fixing color coated galvalume/ prepainted galvalume profile sheets roofing accessories approved by Engineer-in-charge) 0.45 to 0.7 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277/ASTMA792M, in 550 mpa grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self driving/ self tapping (coroshields make) screws complete :L-Flashing 600mm.
41Dismantling Existing pipes of any diameter inlet and outlet pipes for GI/Pvc/SWR all complete as per direction of site incharge (external work)including removal of clamps , making holes, fittings etc.,complete taking out the pipes of any diameter of size, manually/ by mechanical means including stacking of pipes in departmental stores as per direction of Engineer-in-charge
42Providing and fixing uPVC- SWR (sewage waste & Rain water) pipes for sewer lines - Type:B of \ISI : 13592 of approved make and quality with all necessary specials such as collars, elbows, shoe,bends, tees, doors Y's cowl cap, G.I coated special clamps at the interval of 1m etc., using jointing ring with solutions for necessary scaffolding etc., complete with all lead lift and as directed by the Engineer-in-Charge. 150mm dia.
43Providing and fixing fluted vinyl matt finish PVC wall panelling using multi-chambered hollow PVC sections of size 314 mm × 12 mm, interlocked with each other by means of lap joints and fixed over aluminium grid partition using suitable SS screws (aluminium grid partition shall be measured and paid separately). The panelling shall also be fixed on both sides of WPC door shutters (WPC shutters shall be measured and paid separately), including making necessary cut-outs for electrical connections, switch boards, fixtures, fans, lights, air-conditioning, etc.The work includes finishing with PVC beadings, horizontal powder-coated aluminium joint beading, and covering all exposed edges, corners, and junctions with extruded PVC corner beadings fixed using cyanoacrylate adhesive, complete as per manufacturer’s specifications and as directed by the Engineer-in-charge.Note: Measurement shall be taken for both sides together; no separate payment shall be made for each side.Make: Qute/Duroplast or equivalent.
44Providing and fixing of Zebra Blind for Windows Dual Layer Zebra Roller Shades Light Filtering Sheer Window Treatments Privacy Light Control for Day and night including required curtains, frame, operating mechanism, fixing SS screws and removing of existing blinds and making good the wall etc complete. For any colors, patterns, quality and design as per the approval of Eneering-In-Charge.Make:Vista or equivalent
45Electrical Items
46MODULAR LIGHT/FAN PT: Wiring for light / fan / exhaust fan / call bell point with 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size GI. box and earthing the point with 1.5sqmm. FRLS PVC insulated copper conductor single core cable etc., as required.
47CIRCUIT WIRING : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
48CIRCUIT WIRING : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
49CIRCUIT WIRING : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
50CIRCUIT WIRING IN EXISTING: Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
51CIRCUIT WIRING IN EXISTING: Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
52MODULAR 5A SWITCH : Supplying and fixing following modular switch on the existing modular plate & switch box including connections but modular plate etc. as required.5/6 amp switch
53MODULAR 5A SOCKET : Supplying and fixing following modular socket on the existing modular plate & switch box including connections but modular plate etc. as required.3 pin 5/6 amp socket outlet
54MODULAR 15A SWITCH : Supplying and fixing following modular switch on the existing modular plate & switch box including connections but modular plate etc. as required.15/16 amp switch
55MODULAR 15A SOCKET : Supplying and fixing following modular socket on the existing modular plate & switch box including connections but modular plate etc. as required.6 pin 5/16 amp socket outlet
56GI Box alongwith modular base & cover plate : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches & sockets and junction box in recess etc as required. 6 Module (200mm x 75mm )
57GI Box alongwith modular base & cover plate : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches & sockets and junction box in recess etc as required. 12 Module (200mm x 150mm )
58CABLE END TERMINATION: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Upto 4 X 10 sq. mm
59Copper wire: Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
60EARTH BUS: Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface alongwith insulator for earthing connections etc. as required.
61Plate Earthing: Earthing with copper earth plate 600 x 600 x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arragement and watering pipe of 2.7 metre long with charcoal/coke and salt, testing earth resistivity of the Electrode and provision of 2'x2'x1' brick & cement chamber with 2'x2' RCC cover etc. as required.
62MV Cable Laying: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 35 sqmm size on wall surface/recessed as required. Upto 35sqmm (clamped with 1mm thick saddle)
63CABLE END BOX: Supplying and fixing of cable end box ( Loose wire box) suitable for following single pole and neutral, sheet steel,MCB distribution board, 230V on surface/recess,complete with testing and commissioning etc.as required. For 8 way,Double door SPN MCB DB
64DOUBLE POLE MCB WITH METAL ENCLOSURE:Supplying and fixing DP sheet steel enclosure on surface/recess along with 32A 240V \\"C\\" curve, DP miniature circuit breaker complete with connections, testing and commissioning etc. as required.
65MCB:Supplying and fixing 16 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
66MCB:Supplying and fixing 16 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A Double pole
67SINGLE PHASE DB : Supplying and fixing of following way surface/recess mounting, horizontal type single pole and neutral, sheet steel, MCB distribution board, 230V, on surface/recess, dust protected, duly powder painted with tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs incomer and outgoings) as required. 8 way, Double door
68SPLIT AC (1.5TR) : Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 1.5 TR with 5 Star BEE Rating
69LED Panel light 2x2 ft (36Watts) (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) 36Watts
70CABLE MANEGMENT SYSTEM: Supply and laying of following upvc drawing cable manegment system with the necessary straight cover, end cab etc.,as required.105 mm x 50 mm
71SUPPLY OF 4 CORE, 6 SQ MM, COPPER UG CABLE:Supply of 4 core, 6 sq mm, PVC insulated, Sheathed and armored Copper cable 1100 V grade as per IS 1554 Standard UG cable, produce with necessary test certificate etc. as required.
72Supply & Fixing of Copper Refrigerant piping (5/8\\" & 1/4\\") with insulation (IDU to ODU) in surface / CMS along with water drain pipe from IDU for high wall split AC units with neat finishing as required.
73WALL MOUNTING BLDC FAN:Supply, installation and testing of 400mm sweep wall mounting bldc fan 230V suitable wall colour with necessary oscillation control, fixing of suitable clamps, remote etc., as required400MM Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56332730
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20.95 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender for Providing And Fixing Partition For Accommodating Sophisticated Analytical Equipment In Room No.Mb-001 At Ground Floor Of Main Building And Gas Shed For Nmr Facility At Caters Division, Csir-Clri, Adyar, Chennai - 600020
Basic Detail
Tender No CLRI/03(01)/2026-27/Wks
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 06 Jul 2026
Submission Date 27 Jul 2026
Open Date 28 Jul 2026
Finance
Tender Value 20.95 Lakhs
Tender Fee Ref. Documents
EMD 41900
Exemption Not Available
Document List
BOQ_330207.xls
f1948ad8-398f-4736-b47e-db24686bb3d0.html
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Jul 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_330207.xls

html

f1948ad8-398f-4736-b47e-db24686bb3d0.html

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders