Housing Urban and Rular Development Government Departments Closing in 10 days TDR #56331911

Tender For Construction Of Multiutility Sports Complex (Badminton Court, Open Swimming Pool, Toilet, Change Room, cement concrete Road, Cinder Track And Cricket Ground With Lighting) At Lucknow Cantt District -Lucknow (U.P.) (Notice No. -55/Uppcl/Gm-

Issued by Government Departments · Lucknow, Uttar Pradesh
Tender Value
7.62 Crore
Estimated cost
Bid Submission
18 Jul 2026
10 days left
EMD
15.25 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Multiutility Sports Complex (Badminton Court, Open Swimming Pool, Toilet, Change Room, cement concrete Road, Cinder Track And Cricket Ground With Lighting) At Lucknow Cantt District -Lucknow (U.P.) (Notice No. -55/Uppcl/Gm-7/E-Tender/2026-27 Dated: 03.07.2026)

BOQ

Name of Work:- Construction of Multiutility Sports Complex (Badminton Court, Open Swimming Pool, Toilet, Change Room, C.C. Road, Cinder Track and Cricket Ground with Lighting) at Lucknow Cantt District –Lucknow (U.P.) (Notice No. -55/UPPCL/GM-7/E-TENDER/2026-27 Dated: 03.07.2026)
Sl. No. Item Description
1Construction of Multiutility Sports Complex (Badminton Court, Open Swimming Pool, Toilet, Change Room, C.C. Road, Cinder Track and Cricket Ground with Lighting) at Lucknow Cantt District –Lucknow (U.P.)
2BADMINTON COURT
3UP TO PLINTH LEVEL
4Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
5Carted earth filling By Mechanical Transport including loading, unloading and stacking earth lead up to 5 km.excavation with cost of earth.
6Supply and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
7Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
8Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
9With Chlorpyriphos/Lindane E.C. 20% with 1%
10concentration
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size
12Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from
13natural sources)
14Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
15Providing and laying in position ready mixed or site batched design mix cement concrete for
16reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works upto plinth level5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum
17COLUMN
18Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
19Thermo-Mechanically Treated bars of grade Fe-500D or more.
20Centering and shuttering including strutting, propping etc. and removal of form for
21Lintels, beams, plinth beams, girders, bressumers and cantilevers
22Column
23Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation M-150 .
24Cement mortar 1:4 (1 cement : 4 coarse sand)
2515 mm cement plaster of mix :
261:4 (1 cement: 4coarse sand)
27Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
2840 mm thick with 20 mm nominal size stone aggregate
29APPRON DRAIN ALONG APPRON 150X150
30BADMINTON COURT
31SUPER STRUCTURE
32Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete.
33All works above plinth level upto floor V level
345.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum
35COLUMN
36LINTEL
37Centering and shuttering including strutting, propping etc. and removal of form for
38COLUMNS
39LINTEL
40Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
41Thermo-Mechanically Treated bars of grade Fe-500D or more.
42Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :
43Cement mortar 1:6 (1 cement : 6 coarse sand)
44Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level.
45Cement mortar 1:4 (1 cement :4 coarse sand)
46Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
47Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :
4820 mm dia
49Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixingapproved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
50Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)
51For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
52Powder coated aluminium (minimum thickness of powder coating 50 micron)
53Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
54With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
55Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
56Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,
57handles, including applying a priming coat of approved steel primer.
58Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
59With 12 mm mild steel U beading
6012 mm cement plaster of mix :
611:6 (1 cement: 6 coarse sand)
62Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
6325 mm thick with 20 mm nominal size stone aggregate
64Supply and laying of Badminton court indoor mate 4.5mm thick including cost of materials ,labour etc complete
65Court area
66Providing and fixing of 20mm thick Imported Hard Maple wood Tongue and grooved planks MFMA Certified supported by sleepers pine/spruce/fir padded runners duly treated with Woodlife anti termite treatment of section 63.5mm x 38mm placed with distance between the runner to be 10” along the width of the court. Imported SafeSleeper shock absorption pads of 11mm thick will be provided under the runners for shock absorption. A vapor barrier be of 0.2mm thick will also be introduced between sub floor and frame work. The frame will be duly fastened to the sub floor with theaid of clamps. The floor will be duly leveled with threephase machine grinding, followed by MFMA recommended coating.
67Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
68Granite stone slab of colour black, Cherry/Ruby red
69Area of slab over 0.50 sqm
70Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
7125 mm thick
72Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
73Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
74Finishing walls with Acrylic Smooth exterior paint of required shade :
75New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
76Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :
77New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
78Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
79Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
80Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
81Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
82Providing and fixing Ozone Glass Door Lock With Strike Box OPL-4A/4B-N-STD-SSS with nuts and screws etc. complete
83Providing and fixing Ozone 25 mm x 450 mm SSS Glass Door Handle OGH-55, ISI marked, with necessary screws etc. complete
84Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm ofcement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the
85(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. * All above operations to be done in order and as directed and specified by the Engineer-In-charge:
86With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
87Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in truehorizontal level, suspended on inter locking metal grid of hot dipped galvanized steelsections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runnerwith suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mmthick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mmmade of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middleof the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectorsetc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall bepre-painted with polyester paint, all complete for all heights as per pecifications, drawings and as directed by Engineer-in-charge.
88GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.
89Providing and fixing false ceiling at all height including providing and fixing of frame work
90made of special sections, power pressed from M.S. sheets and galvanized with zinc coatingof 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre,one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm diabolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length
91with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I.channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which theceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm eachhaving lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicularto G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high havingflanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the helpof rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including
92fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall
93screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish oftapered and square edges of the board with recommended jointing compound , jointing tapesfinishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint
94and two coats of primer suitable for board, all as per manufacturer’s specification and also
95including the cost of making openings for light fittings, grills, diffusers, cutouts made with
96frame of perimeter channels suitably fixed, all complete as per drawings, specification and
97direction of the Engineer in Charge but excluding the cost of painting with :
9812.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
99Supplying and fixing 50 mm thick aluminium foil faced resin bonded fibre glass insulation Under profile sheet of density 24 kg/cu.m or mineral wool insulation(non combustible) of density 44 kg/cum sealing all joints with self adhesive aluminium tape & covering with 0.63mmx19mm GI wire mesh netting butting all joints and laced with GI wire complete as per specifications and as required.
100BADMINTON COURT
101Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding an bolted with special shaped washers etc. complete.
102Electric resistance or induction butt welded tubes
103Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
1041.00 mm thick precoated galvanised iron profile sheets
105Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes
106complete.
1070.80 mm thick with zinc coating not less than 275 gm/m
108Extra for providing and fixing wind ties of 40x6 mm flat iron section.
109Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
1100.63 mm thick with zinc coating not less than 275 gm/m²
111Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal &
112vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc.and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting withthe building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete
113as per directions and approval of Engineer-in-charge.
114Note:- (1) The elevational area of the scaffolding shall be measured for paymentpurpose. (2) The payment will be made once only for execution of all items forsuch works.
115BADMINTON COURT
116INTERNAL SANITARY W/S INTALLATION WORKS
117SANITARY INSTALLATIONS & FITTINGS
118INTERNAL SOIL /WASTE PIPE LINE
119Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
120110mm (Rainwater+soil+waste)
121Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
122(i) Single socketed pipes.
123110 mm diameter*2
124Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
125Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for
126unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
127Bend 87.5°
128110 mm bend
129Shoe (Plain)
130110 mm Shoe
131INTERNAL ELECTRICAL WORK (WIRING AND FIXTURE INSTALLATION )
132W I R I N G
133Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
134Group C
135Wiring for group controlled(looped) light point/fan point/exhaust fan point/call bell point(without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
136Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
1372 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1382 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1392 X 4 sq. mm + 1 X 4 sq. mm earth wire
1404 X 6 sq. mm + 2 X 6 sq. mm earth wire
1414 X 10 sq. mm + 2 X 10 sq. mm earth wire
1424 X 16 sq. mm + 2 X 16 sq. mm earth wire
143Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1442 x 2.5 sq. mm
145Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
14620 mm
14725 mm
148Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
149Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
150Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required
1511 or 2 Module (75mmX75mm)
1526 Module (200mmX75mm)
153Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1545/6 amps switch
1553 pin 5/6 amp socket outlet
156Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
157Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
158Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
159Upto 450 mm sweep
160MCCB, MCB & DB'S
161Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
1624 way (4 + 12), Double door
163Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
16412 way, Double door
165Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
166Single pole
167Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
16840 amps
169Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
17063 amps
171Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
17225 amps
17340 amps
17463 amps
175Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
176E A R T H I N G
177Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt ) as required.
178Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
179Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
180Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
18170 sqmm 3.5 core
182Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire
18370 sqmm 3.5 core
184Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
18570 sqmm 3.5 core
186Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
18763 mm dia (OD-63 mm & ID-51 mm nominal)
188Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only
189Main L.T. Panel
190Incoming :
191125 Amp. MCCB-1 Nos.
192Outgoing :
19332 Amp MCCB-2 No ,63AMP MCCB-2 No
194Cat. B. Pannel Cubicle Type
195Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules.
196Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.
197Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects.
198LED Down lighter (SMD Type) (System lumen
199efficacy ≥ 105 < 120 lm/Watt )
200Supplying, Installation, Testing & Commissioning of
201LED Recessed/ surface Down lighter (Round/
202square/ Rectangular) SMD type of following body
203material with PMMA and prismatic diffuser and
204construction as per IS : 10322 with driver as per the
205requirement with Driver efficiency >85%, Operating
206voltage AC 140-270 Volt, frequency 50/60 hz,
207Operating temp range -50C to 400C, internal surge
208protection of 2.5 KV with Short & Open circuit
209protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,
210UGR (Unified Glare Rating) < 19, Flicker free (flicker
211should be below 5%), life time (LED, Driver &
212electrical circuitry), of minimum 50000 Burning
213Hours with 70% of initial Lumen maintained till
214life ends, CCT 3000°K /4000°K / 5700°K /
2156500°K (As per ANSI Bin), SDCM (Standard
216Deviation Colour Matching) <3, Maximum power
217consumption should not more than the specified
218rating and Fixture shall be confirming to relevant BIS
219standards. Manufactures Word Mark/ Name
220Engraved/ Embossing/ Screen printing on housing
221Complete in all respect i/c external connections
222with 1.5 sq.mm FRLS/HFFR, PVC insulated
223copper conductor single core cable and earthing etc.
224as required with Minimum 5 year OEM warranty.
225System lumen efficacy ≥105 and <120 lm/Watt
226output . LM79 & LM80 Test report and all testing
227required for LED fixtures as per BIS shall be
228submitted. Shape size and CCT shall be as
229approved by Engineer-in-Charge as per
230requirement. (Thermal management: heat sink of
231aluminium housing such that LED junction
232temperature shall not rise above 90°C)
233Powder coated die cast /Extruded aluminium
234Body including trim
23512 -15 watt
236Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 200 Watt. Confirming to IP 66 protection complete in all respect.
237Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.
238Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required
239Industrial Exhaust Fan
240Supply and erection of AC 230/250 Volts, 50 Hz Wall fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required
241Wall Fan
242FIRE FIGHTING SYSTEM
243FIRE ALARM ELE DSR-2025
244FIRE EXTINGUISHER
245Supply and fixing of fire extinguiser ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work
246Supply and fixing of fire extinguiser ,CO2 Type 4.5 kg capacity (ISI Marked IS : 2878 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work.
247Supply and fixing of fire extinguiser ,CO2 Type 9 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work.
248Supply and fixing of fire bucket 9-11 litres capacity with river sand fill supply of all materials and labour for proper completion of work.
249SWIMMING POOL (25X12.50)
250BILL OF QUANTITY
251Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
252All kinds of soil
253Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
2541:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
255Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
2561:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
257Centering and shuttering including strutting, propping etc. and removal of form for
258Columns, Pillars, Piers, Abutments, Posts and Struts
259Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
260Thermo-Mechanically Treated bars of grade Fe-500D or more.
261Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge:
262Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Light shade pigment using white cement
263Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing
264cement compound @ 0.253 kg/sqm.
265(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to
266air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
267Providing and fixing of R.C.C. overflow drain (300X300) Internal size and Top M.S.Grill Cover from Swimming pool to Filter plant including matreials and labour etc as directed by Engineer-in-charge
268Carted earth filling By Mechanical Transport including loading, unloading and stacking earth lead up to 5 km.excavation with cost of earth.
269SEATING- 27.445X3.830
270BILL OF QUANTITY
271Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
272All kinds of soil
273Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
2741:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
275Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation 7.5 in foundation and linth in:
276Cement mortar 1:6 (1 cement : 6 coarse sand)
277Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
2781:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
279COLUMN
280GRADE BEAM
281Centering and shuttering including strutting, propping etc. and removal of form for
282Column
283Lintels, beams, plinth beams, girders, bressumers and cantilevers
284Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
285Thermo-Mechanically Treated bars of grade Fe-500D or more.
286Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
287All works above plinth level upto floor V level
288Column
289Ground floor
290Ground floor
291Ground floor
292Centering and shuttering including strutting, propping etc. and removal of form for
293shuttering work in Column
294Ground floor
295shuttering work in Slab
296Ground floor
297shuttering work in Beam
298Ground floor
299Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
300Thermo-Mechanically Treated bars of grade Fe-500D or more.
301Ground floor
302Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey
303cement slurry mixed with pigment to match the shade of the slab, including rubbing and
304polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
30525 mm thick
306Swimming Pool Equipments
307Filtration Equipment
308Bobbin Wound Side Mount Filter Dia 900 MM With 02\\" MPV & 03 Pcs Unions
309Flow = 30 m3/hr
310Filtration Velocity = 27 m3/hr/m2
311Max. Working Pressure = 2.5 Kg/cm2
312Filter media- sand (In Killograms)
313Aquanomics/ Zodiac / Jandy / Solrite India/ Hayward
314OEM Certification Required With Performance Certificate
315Dosing Equipment
316Dosing Pump 0-6 LPH NSL Series (Offline Dosing Pump- 4 Kg)
317Dosing Tank 100 Ltrs with Manual Agitator
318Emaux/ Aquanomics/ Zodiac / Jandy / Solrite India/ Hayward
319Flow Fittings
320Floor Inlet ABS (Main Pool-34 Kids Pool-6)
321Main Drain Frame 300 mm * 300 mm Stainless Steel
322Suction Inlet (Main Pool-4 Kids Pool-2)
32325 m3 UV -C Disinfection Nano Tech With Timer
324Emaux/ Aquanomics/ Zodiac / Jandy / Solrite India/ Hayward
325Overflow Grating
326Overflow Grating 250- 300 mm (110 Mtr)
327Aquanomics/ Zodiac USA / Jandy USA/ Solrite India
328Ladders
329SS Ladder 2 Step AISI 304 Handrails Dia 42 mm
330SS Ladder 3 Step AISI 304 Handrails Dia 42 mm
331SS Ladder 4 Step AISI 304 Handrails Dia 42 mm
332Aquanomics/ Zodiac / Jandy / Solrite India/ Hayward
333Control & Regulation Equipment
334Ball Valve 50 mm Dia
335Ball Valve 63 mm dia
336Ball Valve 75 mm Dia
337Non Returning Valve Dia 63 mm
338Non Returning Valve Dia 75 mm
339Cepex/ Aquanomics/ Hidroten / Hayward
340OEM Certification Required With Performance Certificate
341Cleaning Accessories
342Vaccum Head 18\\" Alumuniam Vacuum Head With 04 Wheels
343Vaccum Hose 1.5\\" - 15m
344Telescopic Pole 4.8M Long
345Curved Brush
346Deep Leaf Net
347Test Kit
348Chemical -Tri Chloroisocyanuric Acid TCCA 90
349Aquanomics/ Harvia Group/ Hayward/ Zodiac / Jandy
350OEM Certification Required With Performance Certificate
351Selfpriming Pump 3 HP /Single Phase (04)-Re circulation
352Thermal Protector 2900 RPM.
353Motor : IPX5
354Insulation class : F
355Flowrate : 25 m3/hr
356Head : 12 Mtr
357Voltage : 220/240 V
358Power : 2.2 kW / 3 HP
359Aquanomics/ Zodiac / Jandy / Harvia Group/ Hayward
360OEM Certification Required With Performance Certificate
361Quotation for Allied Equipment
362Supply & Installation of u-PVC Pipes & Fittings
363Supreme / Finolex / Prince UPVC Pipe for PVC-U Agriculture 10 kg/cm² (Grey Colour)
36450 mm dia
36563 mm dia
36675 mm dia
36790 mm dia
368110 mm dia
369160 mm dia
370Supreme / Finolex / Prince
371Supply & Installation of Control Panel and Cables
37203 Core 2.5 sq mm /
37332-A TP MCCB Outgoing Feeder Suitable For 3 HP Pump DOL Starter
3746 A TPN MCB PH Dosing Pumps & LED Lights
375100 Amps TP Incoming MCCB
376Reputed Brand, L&T, Havells
377Quotation for Installation
378Installation, Testing & Commissioning Of Swimming Pool Eqipment
379Under Water Illumination
380Underwater RGB LED Light 54 W/12V In Steel/ PVC (18 * 3W) Pool
381Aquanomics/ Zodiac / Jandy / Solrite India/ Hayward
382Cable Conduit
383Junction Box in ABS/ Deck Box
384SMPS Including RGB Remote & Pannel
385FILTER PLANT
386Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
387All kinds of soil
388Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
389Supply and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
390Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
3911:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
392Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
393Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
394Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Foundation and Plinth in:
395Cement Mortar 1:6 (1 Cement : 6 Coarse sand
396Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
3971:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
398COLUMN
399GRADE BEAM
400Centering and shuttering including strutting, propping etc. and removal of form for
401Column
402Lintels, beams, plinth beams, girders, bressumers and cantilevers
403Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
404Thermo-Mechanically Treated bars of grade Fe-500D or more.
405Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment(excluding the cost of chemical emulsion) :
406Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart.
407APPRON DRAIN ALONG APPRON 150X150
408Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40940 mm thick with 20 mm nominal size stone aggregate
410FILTER PLANT
411Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
412All works above plinth level upto floor V level
413Column
414Ground floor
415Lintle Band
416Ground floor
417Ground floor
418Ground floor
419Centering and shuttering including strutting, propping etc. and removal of form for
420shuttering work in Column
421Ground floor
422shuttering work in Lintel Band
423Ground floor
424shuttering work in Slab
425Ground floor
426shuttering work in Beam
427Ground floor
428Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
429Thermo-Mechanically Treated bars of grade Fe-500D or more.
430Ground floor+first floor
431Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:
432Cement mortar 1:4 (1 cement : 4 coarse sand)
433Ground Floor
434Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
435Cement mortar 1:4 (1 cement :4 coarse sand)
436Ground floor
437Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
4384.0 mm thick glass panes
439Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete..Fixed to steel windows by welding
440Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators,
441side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B
442etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash
443bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of
444approved steel primer, but excluding the cost of other fittings,glass panes complete all as per
445approved design, (sectional weight of only steel members shall be measured for payment).
446Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.
4471:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
448Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6
449mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,
450handles, including applying a priming coat of approved steel primer.
45115 mm cement plaster on rough side of single or half brick wall of mix of 1:4 cement & coarse sand of 2.25 F.M.
452Ground Floor
45312 mm cement plaster of mix
4541:6 (1 cement: 6 coarse sand)
455OUTER PLASTER
45612 mm cement plaster of mix
4571:6 (1 cement: 6 coarse sand)
458Ground Floor
4596 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In- Charge.
460Ground Floor
461Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
462Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
463b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs
464c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin- Charge :
465With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
466Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
46740 mm thick with 20 mm nominal size stone aggregate
468Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
469Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
470Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
471New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
472Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete, as per manufacturer's specification.
473New work ( two or more coats ) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.
474Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete, as per manufacturer's specification.
475New work ( two or more coats ) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre.
476Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
477FILTER PLANT
478SANITARY INSTALLATIONS & C.P FITTINGS
479RAIN WATER PIPES
480Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
481110mm
482Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.
483110 mm
484Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
485Bend 87.5 degree
486110 mm Bend
487Shoe (Plain)
488110 mm Shoe
489Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
490Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
491FILTER PLANT
492INTERNAL ELECTRICAL WORK (WIRING AND FIXTURE INSTALLATION )
493W I R I N G
494Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
495Group C
496Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
4972 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4982 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4992 X 4 sq. mm + 1 X 4 sq. mm earth wire
5004 X 6 sq. mm + 2 X 6 sq. mm earth wire
5014 X 10 sq. mm + 2 X 10 sq. mm earth wire
502Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
503Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
504Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
505Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
506Upto 450 mm sweep
507MCCB, MCB & DB'S
508Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
5094 way (4 + 12), Double door
510Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
511Single pole
512Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
51363 amps
514Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
51525 amps
51640 amps
51763 amps
518Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
519E A R T H I N G
520Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (with charcoal/ coke and salt ) as required.
521Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
522Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
523Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
524185 sqmm 3.5 core
52570 sqmm 3.5 core
52635 sqmm 3.5 core
527Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire
528185 sqmm 3.5 core
52970 sqmm 3.5 core
53035 sqmm 3.5 core
531Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
532185 sqmm
53370 sqmm 3.5 core
53435 sqmm 3.5 core
535Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only
536Main L.T. Panel
537Incoming :
538200 Amp. MCCB-1 Nos.
539Outgoing :
54063 Amp MCCB-3 No
541Cat. B. Pannel Cubicle Type
542Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules.
543Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.
544Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects.
545LED Down lighter (SMD Type) (System lumen
546efficacy ≥ 105 < 120 lm/Watt )
547Supplying, Installation, Testing & Commissioning of
548LED Recessed/ surface Down lighter (Round/
549square/ Rectangular) SMD type of following body
550material with PMMA and prismatic diffuser and
551construction as per IS : 10322 with driver as per the
552requirement with Driver efficiency >85%, Operating
553voltage AC 140-270 Volt, frequency 50/60 hz,
554Operating temp range -50C to 400C, internal surge
555protection of 2.5 KV with Short & Open circuit
556protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,
557UGR (Unified Glare Rating) < 19, Flicker free (flicker
558should be below 5%), life time (LED, Driver &
559electrical circuitry), of minimum 50000 Burning
560Hours with 70% of initial Lumen maintained till
561life ends, CCT 3000°K /4000°K / 5700°K /
5626500°K (As per ANSI Bin), SDCM (Standard
563Deviation Colour Matching) <3, Maximum power
564consumption should not more than the specified
565rating and Fixture shall be confirming to relevant BIS
566standards. Manufactures Word Mark/ Name
567Engraved/ Embossing/ Screen printing on housing
568Complete in all respect i/c external connections
569with 1.5 sq.mm FRLS/HFFR, PVC insulated
570as required with Minimum 5 year OEM warranty.
571System lumen efficacy ≥105 and <120 lm/Watt
572output . LM79 & LM80 Test report and all testing
573required for LED fixtures as per BIS shall be
574submitted. Shape size and CCT shall be as
575approved by Engineer-in-Charge as per
576requirement. (Thermal management: heat sink of
577aluminium housing such that LED junction
578temperature shall not rise above 90°C)
579Powder coated die cast /Extruded aluminium
580Body including trim
58112 -15 watt
582Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting
583including tube on Surface complete in all respect.
584Cat. AAA
585Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required
586Industrial Exhaust Fan
587FILTER PLANT
588FIRE EXTINGUISHER
589Supply and fixing of fire extinguiser ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work
590Supply and fixing of fire extinguiser ,CO2 Type 4.5 kg capacity (ISI Marked IS : 2878 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work.
591Supply and fixing of fire bucket 9-11 litres capacity with river sand fill supply of all materials and labour for proper completion of work.
592SWIMMING POOL EXTERNAL ELECTRICAL WORKS
593CABLES
594Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc.
59510 sq. mm 2 core
596Supply and fixing of brass nickle plated compression gland for PVC insulated and armoured served sheathed, under ground cable including rubber ring etc. complete in all respects, the armouring of the cable shall be properly connected with earth as per direction of Engineer-in-charge.
59710 sqmm 2.0 core
598Supply and fixing of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape, and making connections etc. complete in all respects as per directions of the Engineer-in-charge.
59910 sqmm
600EXTERNAL WORK
601Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
602Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 250Watt. Confirming to IP 66 protection complete in all respect.
603Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
6042 x 2.5 sq. mm
605BILL OF QUANTITY
606BOUNDARYWALL 3.6*3+.30=11.10 METRE LENGTH , 1.8 METRE HEIGHT+.60 AND 4PANEL
607Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
608All kinds of soil
609Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
6101:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40
611mm nominal size)
612Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from
613natural sources)
614Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
615Providing and laying in position specified grade of reinforced cement concrete, excluding the
616cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :l
6171:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone
618aggregate 20 mm nominal size derived from natural sources)
619COLUMN
620Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°
621landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral
622stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,
623finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from
624natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
625COLUMN
626Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
627Thermo-Mechanically Treated bars of grade Fe-500D or more.
628Centering and shuttering including strutting, propping etc. and removal of form for
629Lintels, beams, plinth beams, girders, bressumers and
630cantilevers
631Column
632Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :
633Cement mortar 1:4 (1 cement :4 coarse sand)
63412 mm cement plaster of mix :
6351:6 (1 cement: 6 coarse sand)
636Finishing walls with Acrylic Smooth exterior paint of required shade :
637New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
638Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle
639sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm
640flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of
641necessary butt hinges and screws and applying a priming coat of approved steel primer, all
642complete as per the direction of Engineer-In-charge.
643Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
644Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
645Providing and fixing concertina coil fencing with punched tape concertina
646coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain
647horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre
648(cost of M.S. angle, C.C. blocks shall be paid separately)
649GATE 4.5 METRE WIDE
650Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
651All kinds of soil
652Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
6531:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
654Providing and laying in position specified grade of reinforced cement concrete, excluding thecost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
6551:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stoneaggregate 20 mm nominal size derived from natural sources)
656COLUMN
657Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
658COLUMN
659Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
660Thermo-Mechanically Treated bars of grade Fe-500D or more.
661Centering and shuttering including strutting, propping etc. and removal of form for
662Column
663Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
66420MM THICK
665Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing inposition and applying a priming coat of approved steel primer using structural steel etc. asrequired.
666In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
667Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
668Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
669Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :
670Cement mortar 1:6 (1 cement :6 coarse sand)
671TUBE WELL BORING WITH PUMPING SYSTEM (150 RM)
672Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
673All types of soil
674400 mm dia
675Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depthbelow ground level.
676400 mm dia
677Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
678200 mm nominal size dia having minimum wall thickness 5.40 mm (Casing pipe )
679150 mm nominal size dia having minimum wall thickness 5.00 mm (Lowring )
680Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per directionof Engineer -in-charge..
681150 mm nominal size dia (Slotted)
682Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity air compressor,running the compressor for required time till well is fully developed,measuring yield of well by “V” notch method or any other approved method,measuring static level & draw down etc. by step draw down method,collecting water samples & getting tested in approved laboratory, i/cdisinfection of tubewell, all complete, including hire & labour charges ofair compressor, tools & accessories etc., all as per requirement anddirection of Engineer-in-charge.
683Providing and fixing suitable size threaded mild steel cap or spot weldedplate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
684200 mm nominal size dia
685Providing and fixing M.S. clamp of required dia to the top of casing/housingpipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts required size complete.
686200 mm nominal size dia
687Providing and fixing Bail plug/ Bottom plug of required dia to the bottomof pipe assembly of tubewell as per IS:2800 (part I).
688200mm nominal size dia
689Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work
69080 mm dia nominal bore
691Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
692125 mm
693100 mm
694Supply and fixing of KSB Make 5 hp Submirssible pump.
695Supply and fixing of nylon jali around the slotted pipes complete as required. Up to 30 meter
696Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete asper direction of Engineer-in-charge.
6973.14*(.200*.200-.100*.100)*60
6983.14*(.200*.200-.075*.075)*90
699Supplying,and fixing of AIR Compressor and clorinator system all complete as per direction of Engineer -in-charge.(For pump room clorinator)
700Lab water Testing
701Electrical work
702Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
703100 Amp, 16 KA, TPMCCB
704Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
70510 SQMM 4 CORE
706Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
7074 x 6 sq. mm
708TOILET BLOCK
709UP TO PLINTH LEVEL
710Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
711All kinds of soil
712Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
713Supply and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
714Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
715Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
716With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
717Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
7181:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
719Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources)
720Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
721Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttring, finishing and reinforcement- All work up to plinth level
7221:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
723COLUMN
724Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
725Thermo-Mechanically Treated bars of grade Fe-500D or more.
726Centering and shuttering including strutting, propping etc. and removal of form for
727Lintels, beams, plinth beams, girders, bressumers and cantilevers
728Column
729Brick work with common burnt clay F.P.S. (non modular brick) bricks of class designation M-150 .
730Cement mortar 1:4 (1 cement : 4 coarse sand)
73115 mm cement plaster of mix :
7321:4 (1 cement: 4coarse sand)
733Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
73440 mm thick with 20 mm nominal size stone aggregate
735APPRON DRAIN ALONG APPRON 150X150
736TOILET BLOCK
737SUPER STRUCTURE
738RCC WORK
739Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
7401:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
741COLUMN
742R.C.C. work in beams, suspended floors, roofs having slope up to 15 ° landings, balconies, shelves, chajjas, lintles, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centring, shuttering, finishing and rainforcement with 1:1.5:3 (1 cement : 1.5 coarce sand including manufactured sand derived from recycled concrete Aggregate (RCA) upto 20% 3 graded stone aggregate 20 mm nominal size derived from natural source).
743LINTEL
744Centering and shuttering including strutting, propping etc. and removal of form for
745COLUMNS
746LINTEL
747STeel reinforcement
748Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
749Thermo-Mechanically Treated bars of grade Fe-500D or more.
750BRICKWORK
751Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :
752Cement mortar 1:4 (1 cement : 4 coarse sand)
753Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :
754Cement mortar 1:4 (1 cement :4 coarse sand)
755Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
756WOOD WORK
757Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
75835 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
759Providing and fixing factory made panel PVC door shutter consisting of frame made out ofM.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top &bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture.M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness,70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angleon both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shallbe flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom railand 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered onboth sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel.10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail &bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading oninner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVCstrip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solventadhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification& drawing.
76030 mm thick plain PVC door shutters
761Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :
76220 mm dia
763M.S.WORK
764Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
76540X40X5
766Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete..Fixed to steel windows by welding
767Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat ofapproved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
768Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
769Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. asrequired.
770In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
771Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestorywindows, all complete with :
7724.0 mm thick glass panes
773FITTING
774Providing and fixing SS sliding door bolts, ISI marked anodised with nuts and screws etc. complete
775300x16 mm
776Providing and fixing SS handles, ISI marked, with necessary screws etc. complete
777125 mm
778FLOORING
779Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
780Granite stone slab of colour black, Cherry/Ruby red
781Area of slab over 0.50 sqm
782Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
783Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand)and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
784Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
78525 mm thick
786Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
787FINISHING WORK
78812 mm cement plaster of mix :
7891:6 (1 cement: 6 coarse sand)
79015 mm cement plaster on rough side of single or half brick wall of mix:
7911:6 (1 cement: 6 coarse sand)
792Finishing walls with Acrylic Smooth exterior paint of required shade :
793New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
794Outerside
795Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :
796New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
797Innerside
798Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :
799New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
800Ceiling
801Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
802Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
803Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
804Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
805Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm ofcement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-incharge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the
806(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. * All above operations to be done in order and as directed and specified by the Engineer-In-charge:
807With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
808TOILET BLOCK
809INTERNAL SANITARY W/S INTALLATION WORKS
810Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
811White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
812Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
813W.C. pan with ISI marked black solid plastic seat and lid
814Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
815One urinal basin with 5 litre white P.V.C. automatic flushing cistern
816Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
817Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
818a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
819Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
820Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
821Kitchen sink with drain board
822510x1040 mm bowl depth 250 mm
823Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
824Semi rigid pipe
82532 mm dia
826Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
827Providing and fixing PTMT Bottle Trap for Wash basin and sink
828Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
829Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
830Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
831600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
832C.P. BRASS FITTINGS
833Providing and fixing unplasticised PVC connection pipe with brass unions
83445 cm length
83515 mm nominal bore
836Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
83715 mm nominal bore
838Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
83915 mm nominal bore
840INTERNAL SOIL /WASTE PIPE LINE
841Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
842110mm (Rainwater+soil+waste)
843Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.
844110 mm diameter
845Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
846Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
847Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories forunplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
848Bend 87.5°
849110 mm bend
850Shoe (Plain)
851110 mm Shoe
852Providing and fixing of UPVC SWR pipe type -B confirming to IS -13592 including jointing the pipe with rubbing ring ,lubricant and UPVC SWR cupler confirming to IS -14735 ,ALSO Including excavation of trenches cutting of walls and holes and repairing the walls ,floors and refiling the trenches as before but excluding supply and cost of other fitting such as elbow bead ,tee and Y -tee including supply of all materials labour and t&p .Required for proper completion of the work .
853a) 110mm dia P.V.C. pipe
854b) 75mm dia P.V.C. pipe
855Providing and fixing of UPVC SWR door bend confirming to IS-14735.
856110MM
857Providing and fixing of UPVC Nahani trap size 100/75mm ,100/90 mm confirming to IS -14735 self cleaning design fixed in pcc 1:2:4 and supply and fixing of 125mm dia heavt duty cp brass jali.
858Providing and fixing of UPVC SWR cowl confirming to IS-14735.
859110MM
860Providing and fixing of UPVC Plain TEE confirming to IS-14735.
86175X75X75MM
862110X110X110MM
863Providing and fixing of UPVC SWR door y confirming to IS-14735.
864110MM
865INTERNAL WATER SUPPLY WORKS
866Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
867Concealed work including cutting chases and making good the walls etc.
86815mm dia nominal outer dia pipes
86920mm dia nominal outer dia pipes
870Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
871Internal work-Exposed on wall
87225mm dia nominal bore
87332mm dia nominal bore
874Providing and fixing gun metal gate valve with wheel of approved quality.
87525mm dia nominal bore
87632mm dia nominal bore
877Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
878Capcity in Per Liters
879Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete
88025 mm nominal bore
881TOILET BLOCK
882INTERNAL ELECTRICAL WORK (WIRING AND FIXTURE INSTALLATION )
883W I R I N G
884Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
885Group C
886Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
8872 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
8882 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
8892 X 4 sq. mm + 1 X 4 sq. mm earth wire
8904 X 6 sq. mm + 2 X 6 sq. mm earth wire
891Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
892Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
893Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
894Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
895Upto 450 mm sweep
896MCCB, MCB & DB'S
897Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8984 way (4 + 12), Double door
899Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
900Single pole
901Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
90225 amps
903Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
904E A R T H I N G
905Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt ) as required.
906Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
907Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
908Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
90910 sqmm 2 core
910LED Down lighter (SMD Type) (System lumenefficacy ≥ 105 < 120 lm/Watt )
911Supplying, Installation, Testing & Commissioning ofLED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following bodymaterial with PMMA and prismatic diffuser andconstruction as per IS : 10322 with driver as per therequirement with Driver efficiency >85%, Operatingvoltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -50C to 400C, internal surgeprotection of 2.5 KV with Short & Open circuitprotection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free (flickershould be below 5%), life time (LED, Driver &electrical circuitry), of minimum 50000 BurningHours with 70% of initial Lumen maintained tilllife ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (StandardDeviation Colour Matching) <3, Maximum powerconsumption should not more than the specifiedrating and Fixture shall be confirming to relevant BISstandards. Manufactures Word Mark/ NameEngraved/ Embossing/ Screen printing on housingComplete in all respect i/c external connectionswith 1.5 sq.mm FRLS/HFFR, PVC insulated
912copper conductor single core cable and earthing etc.as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Wattoutput . LM79 & LM80 Test report and all testingrequired for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be asapproved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink ofaluminium housing such that LED junctiontemperature shall not rise above 90°C)Powder coated die cast /Extruded aluminiumBody including trim
91312 -15 watt
914Supply and fixing of LED Tube Light with batten suitable for up to 2 X 22 watt LED tube light fittingincluding tube on Surface complete in all respect.
915Cat. AAA
916Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required
917Exhaust Fan
918TOILET BLOCK
919SCHEDULE OF QUANTITIES FOR EXTERNAL SEWERAGE &WASTE SYSTEM - I
920Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.
921Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia
922Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) up to haunches of S.W.pipes including bed concrete as per standard design
923150 mm diameter S.W. pipe
924Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.
925150 mm dia. R.C.C. pipe
926Providing and fixing square-mouth S.W. gully trap class SP-1 completewith C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be notless than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
927150x100 mm size P type
928With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
929Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix
930(1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4
931(1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
932a) Inside size 90x80 cm & 500cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg.
933Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.
934EXTERNAL WATER SUPPLY SYSTEM -II
935Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply including all CPVC plain &brass threaded fittings This includes jointing of pipes & fittings with onestep CPVC solvent cement, trenching, refilling & testing of joints completeas per direction of Engineer in Charge.
93632 mm dia nominal bore
937Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.
938Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design
939With common burnt clay M-150.(non modular) bricks of class designation.
940TOILET BLOCK
941SEPTIC TANK -50 USERS -2YEARS
942COST OF EXTERNAL SEWERAGE (SEPTIC TANK) WORKS
943Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality).
944From 0.00 mt to 1.50 mt
9451.50mt to 3.0 mt
946Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
9471:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
948Brick work common burnt clay F.P.S.(non modular) bricks of class designationM-150 in foundation and plinth in:
949Cement mortar 1 : 4(1 cement : 4 coarse sand)
950Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttring, finishing and reinforcement- All work up to plinth level
9511:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
952Suspended floors, roofs, landings, balconies and accessplatform
953Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:
954Thermo-Mechanically Treated bars of grade Fe-500D or more.
95515 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neatcement on the rough side of single or half brick wall.
956Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
957Providing & fixing 75mm dia vent pipes.
958Providing & fixing of 75mm dia cast iron terminal guard.
959Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
960M.D. -10- Circular shape 500mm internal diameter
961SOAKPIT
962Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality).
963From 0.00 mt to 1.50 mt
9641.50mt to 3.0 mt
965Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
9661:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
967Brick work common burnt clay F.P.S.(non modular) bricks of class designationM-150 in foundation and plinth in:
968Cement mortar 1 : 4(1 cement : 4 coarse sand)
969Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttring, finishing and reinforcement- All work up to plinth level
9701:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
971Suspended floors, roofs, landings, balconies and accessplatform
972Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:
973Thermo-Mechanically Treated bars of grade Fe-500D or more.
97415 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.
975Providing & fixing 75mm dia vent pipes.
976Providing & fixing 100mm dia Drain pipes.
977Providing & fixing of 75mm dia cast iron terminal guard.
978Supplying and stacking at site.
979Over burnt (Jhama) brick aggregate 120 mm to 40 mm
980LOCKER ROOM
981FURNITURE
982Technical Specification of the Steel Clothes Lockers Conforming to BIS specification IS:3314-1984(with latest amendment) Type of Steel Clothes Lockers 12 - Locker type Lock type 5-lever lock conforming to IS 729(latest) Locking arrangement (with duplicate Key) Fitted with a hasp and staple arrangement (for 12 and 18 - locker type)Provision of Name plate/Card holders in each door YesAssembly type WeldingInstallation Free standingSteel Cloth Locker with Pedestal YesPedestal fitted with 3 mm Teflon bushPedestal height (± 5 mm) 125 mmCorners Not roundedThe specification has been seen and understood Yes
983Steel sheet material (Hint: For component manufacturing) Hot rolled carbon steel sheet conforming to HR0 grade of IS 1079:2017 (with latest amendment)Minimum thickness of steel sheet for sides 0.8 mmMinimum thickness of steel sheet for back 0.8 mmMinimum thickness of steel sheet For top 0.8 mmMinimum thickness of steel sheet For bottom 0.8 mmMinimum thickness of steel sheet for partition 0.8 mmMinimum thickness of steel sheet for shelves 0.8 mmMinimum thickness of steel sheet for doors 0.8 mmMinimum thickness of steel sheet for pedestal 0.8 mm Hinges Plain butt type made from M.S sheet of minimum 1.6 mm thick Handle of each door made up of Anodized Aluminium andle fixed to door by Machine screwsCoated hooks made up of No coated hooks Hanging rod made up of Mild steel tubular pipe conforming to IS 7138 (latest)Material of number plates NAMaterial of name tag holder NA
984Overall height of cloth lockers (excluding pedestal height) ± 5 mm 1855 mmOverall width of cloth lockers 910 mmOverall depth of cloth lockers 480 mmSize (W x H) of Name plate/Card holder NA
985Type of Steel Clothes Lockers 12 - Locker type
986INETRLOCKING LAYING
987BILL OF QUANTITY
988Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
989With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
990Providing and laying 80 mm thick faciory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as perthe direction of Engineer-in-charge.
991DISMANTLING BOUNDARYWALL
992BILL OF QUANTITY
993Demolishing brick work manually/ by mechanical means including stacking of serviceable
994material and disposal of unserviceable material within 50 metres lead as per direction of
995Engineer-in-charge.
996In cement mortar
997Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials
998by mechanical means, including loading, transporting, unloading to approved municipal
999dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads
1000including all lifts involved..
1001GROUND PREPARATION
1002ABSTRACT OF COST
1003DEVELOPMENT OF SITE
1004Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
1005Extra for levelling & neatly dressing of disposed soil completely as directed by Engineerin- charge.
1006GROUND PREPARATION
1007CINDER RUNNING TRACK
1008Excavation in foundations in ordinary soil (Loam clay or Sand) including lift upto 1.5 m. lead upto 30m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the engineer I/C within a lead of 30 m.
1009Supply of stone Ballast 53mm size from shankargarh to site
1010Supply of stone Ballast 22.4 mm size from shankargarh to site
1011Supply of stone Dust shankargarh to site
1012Providing and laying Cinder with hard stone aggregate of quality, size and grading as specified, with suitable penetration grade, including required key aggregate as specified, spreading coarse aggregatewith the help of self propelled/ tipper tail mounted aggregate spreader and applying by a pressure distributor and then spreading key aggregate with the help of aggregate spreader complete, including consolidation with road roller ofminimum 8 to 10 tonne capacity to achieve specified values of compaction andsurface accuracy
1013Providing and laying of PU LAYER above cinder to finished top layer of track including cost of materials and labour etc complete.
1014Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacityafter excavating earth to an average of 22.5 cm depth, dressing to camber and consolidatingwith road roller including making good the undulations etc. and re-rolling the sub grade anddisposal of surplus earthwith lead upto 50 metres.
1015Track Marking
1016Brick edging in full brick width and half brick depth including excavation, refilling and disposalof surplus earth lead upto 50 metres.
1017With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1018Cricket Ground horticulture preparation
1019Cricket Practice net
1020TENNIS COURT
1021Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
1022All kinds of soil
1023Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
10241:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40
1025mm nominal size)
102652 mm thick cement concrete flooring with concrete hardener topping, under layer 40
1027mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
102820 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1
1029cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening
1030compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This
1031includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
1032Fencing Around court up to 3.0 m height
1033Providing and laying of ACRYLIC TENNIS COURT SURFACE finish
1034LANDSCAPING LAWN& HORTICULTURE WORK-300 SQM
1035Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
1036Add cartage 15 km
1037Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for
1038payment).
1039Add cartage 15 km
1040Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks
1041will be reduced by 8% for payment)
1042Add cartage 15 km
1043Fine dressing of the ground.
1044Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
1045Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from
1046weeds and fit for mowing including supplying good earth, if needed (the grass and earth shall be paid for separately).
1047In rows 5 cm apart in both directions
1048Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.
1049300 sqm cost
1050C.C.ROAD
10516.0 WIDE 1.0 METRE LENGTH=6.0SQM
1052Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
1053Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
1054Providing and laying design mix cement concrete of M-30 grade, in roads/taxi tracks/ runways, using cement content as per design mix, using coarsesand and graded stone aggregate of 40 mm nominal size in appropriateproportions as per approved & specified design criteria, providing dowelbars with sleeve/ tie bars wherever required, laying at site, spreading andcompacting mechanically by using needle and surface vibrators, levellingto required slope/ camber, finishing with required texture, including steelform work with sturdy M.S. channel sections, curing, making provision forcontraction/ expansion, construction & longitudinal joints (10 mm wide x50 mm deep) by groove cutting machine, providing and filling joints withapproved joint filler and sealants, complete all as per direction of Engineerin-charge
1055Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
1056Providing and filling in position rubberized bitumen hot sealing compound for sealing ofexpansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.
1057Using grade ‘A’ sealing compound conforming to IS: 1834.
1058INTERLOCKING PATHWAY
10591.5 METRE WIDE 10.0 METRE LENGTH=15.0SQM
1060BILL OF QUANTITY
1061Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.
1062Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
1063Providing and laying 80 mm thick faciory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as perthe direction of Engineer-in-charge.
1064Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
1065S.S.RAILING
1066BILL OF QUANTITY
1067Supply and Fixing of Hand rail and balustrade modular system passive ss-304 grade decorative railing system comprising of hand rail 50mm and 1.5 mm thick and 3 no .horizontal steel pipe of 19 mm dia and 1.5 mm thick of equal spacing with balustrade for ss pipe of 38nn and 1.5mm thick @ 1200mm c/c of passivated ss304 rade and fix duly on the floor with specially rivet expansion bolt and finish the surface food and covering with steel shoe ,with all visible stainless metal of 304 grade in satin finish high of railing is 900 mm as per detailed specification.
1068S.S.Railing
1069BOUNDARYWALL PAINTING
1070BILL OF QUANTITY
10713.0 METRE LENGTH AND 1.8 METRE HEIGHT
1072Removing white or colour wash by scrapping and sand papering and preparing the surfacesmooth including necessary repairs to scratches etc. complete
1073Finishing walls with Acrylic Smooth exterior paint of required shade :
1074New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
1075EXTERNAL ELECTRICAL WORKS
1076BILL OF QUANTITY
1077CABLES
1078Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc.
107916 sq. mm 4 core
108025 sq. mm 3-1/2 core
1081Supply and fixing of brass nickle plated compression gland for PVC insulated and armoured served sheathed, under ground cable including rubber ring etc. complete in all respects, the armouring of the cable shall be properly connected with earth as per direction of Engineer-in-charge.
108216 sqmm 4.0 core
108325sqmm 4.0 core
1084Supply and fixing of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape, and making connections etc. complete in all respects as per directions of the Engineer-in-charge.
108516 sqmm
108625 sqmm
1087Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
108863 mm dia (OD-63 mm & ID-51 mm nominal)
1089EXTERNAL WORK
1090Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
1091FOR TENNIS
1092Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 250Watt. Confirming to IP 66 protection complete in all respect.
1093FOR TENNIS
1094Supply and laying aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade .
109510 sqmm x2 core
1096Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules.
1097Supply & fixing of 12.50 mtr High mast shaft of approvedmake with rising system hot dip glavanized inside & outside dip,heaving pole sheet thickness 4 mm. Top diaminium 150 mm, Bottom dia 410 mm base plate 32 mmthick suitable for wind velocity as per IS 875 part 3 &having no circumferential weld, with accessories forhigh mast such as head frame suitable for 6 to 12luminaries & its control gear boxes 1.5 HP power toolmoter, 3 point suspension system with steel wire rope 8mm dia, double drum winch, including making suitablefoundation as per manufature drawing/ site reuimentalong with foundation bolts nuts, washers, anchor platesetc completee in all respect.
1098Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 250Watt. Confirming to IP 66 protection complete in allrespect.
1099FOR STADIUM (6X5)
1100Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
11014 X 2.5 sq. mm
1102Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
11034 way (4 + 12), Double door
1104Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1105Single pole
1106Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
110763 amps
1108HIGHMAST FOUNDATION 12.50 MTR HEIGHT 5 nos
1109UP TO PLINTH LEVEL
1110Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
1111All kinds of soil
1112Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
11131:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1114Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttring, finishing and reinforcement- All work up to plinth level
11151:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
1116R.C.C WORK IN FOOTING
1117Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
1118Thermo-Mechanically Treated bars of grade Fe-500D or more.
1119Centering and shuttering including strutting, propping etc. and removal of form for
1120Foundations, footings, bases of columns, etc. for mass concrete
1121Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
1122In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
1123FENCHING AROUND TENNIS 23 METRE LENGTH 3.0 METRE HEIGHT
1124Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 30m.
1125Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
1126Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
11271:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
1128As in item 3 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20.
1129P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
1130Fe 500 TMT Bars
1131Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
1132Hot finished welded type tubes
1133Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colourand shade.
1134Painting one coat over of ready mixed priming paint &one coat of approved superior mixed paint of clear synthetic varnish including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.
1135EQUIPMENT
1136Supplying and fixing of Badminton Net
1137Supplying and fixing of Badminton Net Poles
1138Supplying and fixing of Tennis Net
1139Supplying and fixing of Tennis Net Poles
1140GST Extra as applicable Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56331911
AUTHORITY Government Departments
TENDER VALUE 7.62 Crore
LAST DATE 18-07-2026
Authority
Authority Name Uttar Pradesh Projects Corporation Limited
Work Description Tender for Construction Of Multiutility Sports Complex (Badminton Court, Open Swimming Pool, Toilet, Change Room, cement concrete Road, Cinder Track And Cricket Ground With Lighting) At Lucknow Cantt District -Lucknow (U.P.) (Notice No. -55/Uppcl/Gm-7/E-Tender/2026-27 Dated: 03.07.2026)
Basic Detail
Tender No 55/UPPCL/GM-7/E-TENDER/2026-27 Dated-03.07.2026
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 06 Jul 2026
Submission Date 18 Jul 2026
Open Date 18 Jul 2026
Finance
Tender Value 7.62 Crore
Tender Fee 17700
EMD 15.25 Lakhs
Exemption Not Available
Document List
65d0b523-9c44-4cab-aee4-1197efb83cb6.html
BIDDOC55.pdf
BOQ_2188829.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

65d0b523-9c44-4cab-aee4-1197efb83cb6.html

pdf

BIDDOC55.pdf

xls

BOQ_2188829.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail