Tender For Upgradation Work Of The Labour Room And Operation Room (Ot) Operated For Pregnant Women In The District Joint Hospital, Chitrakoot
Tender Value
85.35 Lakhs
Estimated cost
Bid Submission
17 Jul 2026
6 days left
EMD
1.70 Lakhs
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chitrakoot → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Upgradation Work Of The Labour Room And Operation Room (Ot) Operated For Pregnant Women In The District Joint Hospital, Chitrakoot
BOQ
| Sl. No. | Item Description |
| 1 | PANELLING WALL Supply installation Testing ,Commissioning of Modular OT wall ,Corner ceilinng panels The Pre-fabricated modular construction should be designed and constructed for exact size of 50 mm wall and 30 mm ceiling puff panel made of 0.8 mm thick GI sheet front side and 0.6 mm thick GI sheet back side panels to provide the seamless operatiing room . The adequate support system by keeping minimum possible cavity gap in between wall & ceiling.The gap between the inside filing by metallic body filer . Make: Tata steel /Jsw |
| 2 | VINYL FLOORING:Flooring seamless with perfectly curved flash-covings, resistance to mechanical stress and dynamic loads and having ESD / EMI (Non -conductive) protection characteristics, 2mm thick, washable vinyl. Should be CE and ASTM ( as per clean room certification) certifiedincluding Self Levelling.- Items Should Be CE Certify with ISo 13485. Make:- Geofloor/Tarkket/Gerfloor/Amrstong |
| 3 | Anti Bacterial Paint: Filling of all Joints and Cavities with Metallic Epoxy filler and sanded flush to provide a jointless finish and then sprayed with a water based liquid plastic aseptic and self - sterilizing wall coating system to a d.f.t of 300 microns with primer. Make: SSK JAPAN |
| 4 | SUPPLY INSTALLATION CASSATE AIR SYSTEM: Celling cassette type air conditioner High efficiency Cassette Type inddoor unit ,four way Air discharge for uniform cooling , Auto swing air louvers ,washable air filter ,low noise operation ,digital display /Remote controle. Make : carrier /Dykin. |
| 5 | CELLING LIGHTS (LED LIGHTS FOR CELLING 2X2)Make : Havels/Pansonic |
| 6 | STORAGE UNIT: Supply,Fabrication and installation of SS304 grade storage unit in labour room with twoshelves ,smooth rounded edges,easy to clean surface finish and proper fixing as per site requirment.Make: Tata steel /Jsw |
| 7 | Surgical Scrub Sink : S.S. 304, wall mounted Scrub sink 30'' with tray .Make: jindal steel |
| 8 | Electrical Distribution For labour roomAll high voltage equipment should be installed in a separate enclosure. Complete electrical wiring work including concealed wiring ,swetch boards ,power shokets,MCB installation & Testing&commissioning Make:-Havells/Anchor. |
| 9 | Curt ton TrackMolded I C CU Relling with curttonEvery bed separated through the curtonSize :- L8’ X B 7’ |
| 10 | MGPS Work Dismantling of existing MGPS line in labour Room and reinstallation of complete MGPS system with testing and commissioning |
| 11 | Civil &Plumbing Renovation Work -Labour Room washroom including :- 1.Removal of existing wall and floor tiles. 2.supply and fixing of new wall and floor tiles. 3.Replacementof existing bathroom door including frame if required. 4.supply and installation of new western commode set . 5.Construction of bathroom water tank /platform with plaster and finishing. 6.supply and installation of water geyser for hot water facility. 7.Providing complete water supply line connections including necessary piping ,fittings,valves and connections. |
| 12 | Civil work in OT area including :- 1.Dismantling of existing wall to create opening for new dor in changing room. 2.Brick masonry work to close 4 existing windows . 3.Construstion of new Brick wall for installation of OT Door. 4.Closing of one existing door opening with brick masonary work. Civil work in OT area including wall dismantling for new door ,brickwork & construction of new wall for ot door installation. |
| 13 | Carpentery work Changing Room (OT Area) :-Providing and fixing of one wooden cupbord in changing room ,made of plywood /bord with laminate finish,including shelves,shutters,handles,hinges and complete finishing. |
| 14 | The air-handling units are of double skin construction,draw-thru type comprising of various sections such as Pre-filter section, coil section. Units must be able to work satisfactorily in exposed atmospheric conditions .Double skinned panels are fabricated with Anodized extruded aluminimum extrusion frame work bolted together with sandwich panel having powder coated 0.70mm sheet for outer skin and plain GP 0.63 mm sheet for inner skin. 43 mm thick PUF insulation material is injected between the two panels .Fan motors are highly efficient and work on 440 ± 10% volts,50 cyles, three phase with explosion proof type with class Finstallation, with IP 55 protection. Motors are easily designed forquiet operation and motor speed does not exceed 1440 rpm. Drive to fan is provided through belt-drive arrangement. Belts are of the oil-resistant type .Cooling coil should be 6 row DX type.Each unit is provided with a factory assembled section containing washable synthetic type air filters having anodized aluminium frame .Supply of AHU of 3600 CFM with 6 RD coil DX Type nicotra blower ABB/ Crompton motor mixing box Al. damper in or out 25mm thick panel fresh air damper ST P125 with heating coil.Supply and installation of 2 Nos. condensing unit with 11 TR Supply installation of AHU and Condensing unit starter panel with volt meter, empire meter related LP/HP controller thermostat sensor on/off light with power coated. Providing and fixing of casual dryer 11TR . |
| 15 | LAMINAR AIR FLOW PLANAIR:The Plan-air ceiling ventilation system should dilute the bacteria generated by the operating team and patient in the theatre and to create an Air flow system pattern that carries contaminated air away from the operating table & entering surgical wounds. It should be designed such that filtered, sterile air flows through the operating zone without an admixture of indoor air. The germs and aerosols released by occupants are displaced into adjacent room zone and removed with the exhaust air.Planair Ceiling constructed out of 1.6 mm thick extruded aluminium sheet of size 2400 x 2400 mm having 6 nos of hepa filters. The hepa filters having dust spot efficiency of 99.99% 0.3 micron. Diffuser will be made out of perforated SS304 sheet. Make:-Asia aitr Filter |
| 16 | SURGEON CONTROLl PANNEL8 Tile membrane type surgeon control panel mounted on flush in the theatre wall along distribution board comprisingof following things. 1-Day Time Clock , 2-Lapse Time Clock , 3-Humidity display , 4-Temprature dispaly , 5-Telephone -hands free 6-Medical Gas alarm , with hepa filter statusand room difrancial prassor -Switch for Peripheral lights & O T light. |
| 17 | X-RAY VIEW BOX LEDSupply, Installation , testing & commissioning of X-RAY viewingscreen - LE D - 1410mm W / 640 mm H/29mmD - LED 30-W , dimable switch , Items Should Be CE Certify with ISo 13485 . Make :Dgline system |
| 18 | VINYL FLOORINGFlooring seamless with perfectly curved flash-covings, resistanceto mechanical stress and dynamic loads and havingESD / EMI (conductive) protection characteristics, 2mm thick, washable vinyl. Should be CE and ASTM ( as per clean room certification) certifiedincluding Self Levelling.- Items Should Be CE Certify with ISo 13485.Make:- Geofloor/Tarkket/Gerfloor/Amrstong |
| 19 | AUTOMATIC HERMETICALLY SEALED DOORSliding, hermetically sealing type of door of size 2110 x 1540 mmhaving high density particle board cores, high pressure laminatedfaced on both sides, viewing window 300 x 300 mm and for smooth effortless sliding, the door runs on nylon wheels within an aluminum extrusion track.Microprocessor based electronic automation for door for controlling the direction of movements, the acceleration and speed of the door, with a low noise level pulse generator motor. It includes a photocell for user's safety. Should be CE approved. Make:Metaflex |
| 20 | PANELLING WALLSupply installation Testing ,Commissioning of Modular OT wall ,Corner ceilinng panels The Pre-fabricated modular constructionshould be designed and constructed for exact size of 50 mm walland 30 mm ceiling puff panel made of 0.8 mm thick GI sheet frontside and 0.6 mm thick GI sheet back side panels to provide the seamless operatiing room . The adequate support system by keeping minimum possible cavity gap in between wall & ceiling.The gap between the inside filing by metallic body filer . Make: Tata steel /Jsw |
| 21 | WRITING LIST BOARDWriting Board of size 840 x 640 mm comprises of a flush mounted,1.50 mm thick, white laminate board, bonded to a 10 mm high density fibreboard sheet for additional rigidity-Items Should BeCE Certify with ISo 13485 . Make :-Dgline system. |
| 22 | STORAGE UNIT Supply and installation of storage unit of SS 304 Sheet of reputedmake and having size 1665 x 865 x 350 mm and having two or more glass shelves of toughened glass 6 mm thick, supported with D type bracket with 8 mm thickness and rubber gasket of 2 -mm and mounted flush on wall.Make: Tata steel /Jsw |
| 23 | Ducting For Clean Air System-Input air and Output Air Alluminium Sheet 22 G ,9/10 mm Insulations (Nitril Rubber Pad ), Joint filler -silicon Leek Tested.Make:-Hidalco |
| 24 | PERIPHERAL LIGHTSPERIPHERAL LED LIGHTS with intensity control Recess mounted,non-hygroscopic peripheral lights having compact fluorescent lamp, dimmableSize;-585mmX245 (around plannum ). Make:Dgline system |
| 25 | ANTI BACTERIAL PAINT Filling of all Joints and Cavities with Metallic Epoxy filler and sanded flush to provide a jointless finish and then sprayed with a water based liquid plastic aseptic and self - sterilizing wall coating system to a d.f.t of 300 microns with primer. Make: SSK JAPAN |
| 26 | ANESTHESIA PENDENT SINGLE ARMThe pendant horizontal&drop tube is of mild steel Powder coated Colour as per customer choice • Gas outlet points –2 oxygen, 2 vacuum, 1N2O, 1 air.• The length of horizontal tube is 1000mm long and vertical tube is as per height of OT.• Pendant carrying capacity of 50 - 80 kg equipment• Encapsulated central pivot bearing system sealed for life and free maintenance.• Electrical Switch & Sockets 6/16 amp 6 nos • Data Point – 1 nos.• Telephone point - 1 nos.• Main cabinet is made up of Aluminium.• Double bearing used (not single) for free movement.• Monitor tray, Infusion pump pole and IV stand combined installed as modular pendants.Make . united surgical |
| 27 | SHED Supply ,Fabrication and erection of 10ft x 15 ft tin shed for housing AHU and outdoor units ,includin MS angle /Pipe structure,GI/tin sheet roofing ,anchoring ,painting and complete installation. |
| 28 | PRESSURE RELIEF DAMPERCascade Pressure Stabilizer having multi 304 graded stainless steel blades to control room air pressure .Pressure relief dampers should be provided in each room (SS)to prevent contamination of air from clean and dirty areas. Suitably sized(325mmx365mm) air pressure relief damper should be strategically placed, enabling differential room pressure to be maintained and ensure that when doors are opened between clean and dirty areas. Cascade pressure stabilizers should be a range of multi bladed units specifically designed to prevent contamination of air from clean and dirty areas also control room air pressures in critical areas, such as operating theatre suites. The PRD should remain closed at pressure below the set pressure and should open fully at pressure and should open fully at pressure only fractionally above the threshold pressure Make:-Jindal steel. |
| 29 | SURGICALl SCRUB SINK S.S. 304, 2 Bay Scrub sink 1600 X 600 mm with sensor and foot paddle with manual option mood. With Hot&Cool Water mixing System made for stainless steel grade 304 polished finished.The scrub sink is provided with front access panel for ease of maintenance and repairs.Make . Jindal steel |
| 30 | ELECTRICAL DISTRIUBUTION BOARD All high voltage equipment should be installed in a separate enclosure. The cabinet should house the operating lamp transformers, mains failure relays, MCB's electrical distributionequipment & circuit protection equipment for all circuits within the operating theatre. All internal wiring should terminate in connectors with screw & clamp spring connections of the clip- on type mounted, on a DIN rail & labeled with clear proprietary labels.Individual fees or miniature circuit breakers should protect allinternal circuits-d-Items. Make:-Havells/Anchor. |
| 31 | PASS BOX Complete in S S 304 hinliner finish Size 600X600 mm , with both side indicator of open and close door , with auto lock one door systems ,& Manual Lock with handle -Double Insulated Fixed Glazing tthoughened glass with silicone - Complete Sealed -d -Items. |
| 32 | GYNECOLOGICAL OBSTETRIC TABLE O. T. TABLEObstetrics operating room table perfect for all kind of gynecological operation.Mod:- BJS 008Make: Balaji SurgicalFeatures:-The cover for base and column is made 304 stainless steel,good performance on anti rust and easy to clean .The full electric table with optional battery backup.Factory sealed - Electro Hydraulic SystemsFive Position , Lithotomy Position , Trendelenburg Position , Flex \ Reflex – Position , Chair Position , Urology Position , Proctology Position, With All Standard Accessories & Including Mattress . |
| 33 | OT Light 2 Doom LED Light ( O. T.GYNEE) Mod:- GLANZA 700+700 TWIN LED 2 Doom.Powder Coated, Ceiling Mounted.Specification :-No of LED : 80+80Intensity : 200000 x 2 lux = 400000 luxSpot Diameter : 100-150 mm Diameter of Light : 700+700 mmColour Temperature : 3800-5200KLED average life > 50000 hrsSpecial Function : 5 Memory Function with Remote.Make:Balaji Surgical |
| 34 | Work Station Anesthesia Machine with Isoflurane Veporizer (Gynee O. T. )Mod :- Spectra Medisys.Specifications Fresh Gas Flow: 0-20 L/Min Backbar : Two Select tec vaporizer with interlock Safety Machanism.Absorber Capacity : 1.5 kg.Ventilation Mode : VCV,PCV,ACV-V ACV-P.LED/TFT Display: 7 inch Touch screenPEEP : Electronicaly Controled .Tidal Voulum : 10-1500 ml.Monitoring Parameter :Ppeak,Vte,RR,Mv,PEEP,.Fio2.Wave form: P-T, F-T, V-T.Power Suply :230Vac/50 HzBattery Backup: 3 Hours. Make :Primer Medical Systems & Devices Pvt. Ltd. |
| 35 | Cautory Machine Model : FASTSEAL PLUS (ESU+VesselSealer 2 in 1)Performance Features:Minimal lateral spread thus better quality white seal.Self test facility,Graphic LCD display. Real time tssue impedance measurement with auto stop. sutable for monopolar under water surgeries.Saline plasma Bipolar ResectionTechnical Specification:Power 400 wOperating Freq:480 khzInput Voltage :230 VAC/50HzProgram 99 Programe Memory Weight : 5.5 kgMake:- ENERTECH |
| 36 | 5 Para Monitor with 12.1” TFT Large bright screen.8 real Time configuration waveforf display .Adult, Pediatric, Neonatal applicationE C GSPO2Pulse RateNIBP TemperatureMake :- CLARITY |
| 37 | Suction Machine ( ISI MARK)Mod: Suc -016 HI Vac. 1/2 HP ELECTRIC MOTAR WITH POLYCARBONATE JAR.Make: Sai life |
| 38 | DEFIBRILLATOR MACHINE VITAL WAVE Portable Biphasic Defibrillator with recoder. Features: 7'' color TFT display. Easy Energy Selation from 2-270 jules. ECG acquisition via paddles,patent cable . Manual & synchronized cardioversion modes. Displays selected & delivery energy . Adult & Pediatric patent compatibility. Make :Maestros Electronic &Telecomunication Systems Ltd. |
| 39 | Fogger Machine with timer |
| 40 | A TYPE N2O CYLINDER |
| 41 | A TYPE O2 CYLINDER |
| 42 | Instruments Trolley Size 2x2.5 feet |
| 43 | Dressing Drum Jointless 12x15 |
| 44 | Instrument tray With cover medium 11*7 |
| 45 | Instrument Tray with cover big 12*18 |
| 46 | EXAMINATION LIGHT FOR LABOUR ROOM |
| 47 | Radiant Heat Warmer Mod:RHW5002B Mobile new born resuscitation table -fixed height . Skin,Manual and Pre-warm control modes . Microprocessor based controller with highly accurate thermistor sensors . LCD for alarm messages.up down timer. Ceramic heater with reflector and seafty grill. Patient examination lamp for extra illumination during procedure. X-Ray cassette holder tray underneath baby bed . Make: Zeal medical. |
| 48 | Syringe Pump Model:SA-PT-Crest syringe pump device. Light weight ,ergonomic& Leak Proof Design. LCD Display, capactive Touch screen key pad. vertical /horizontal mounting make :Plenumtek |
| 49 | Infusion Pump Model :Volux volumetric infusion system. Make: plenumtek |
| 50 | Plus Oxy Meter Model Oxy Plus 240ST. LCD display for pleth ,O2 and HR values . Light waight and portable monitor . 48 hours of grafical trends for SPO2 and HR values. Make:Clarity Medical Pvt.Ltd. |
| 51 | Obstetric Labour Table Teliscopic . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender