Tender For Repair/Renovation Of Cafeteria At Razdan Top, Gurez Including Electric Part
Tender Value
3.50 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
2 days left
EMD
7000
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bandipora → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Renovation Of Cafeteria At Razdan Top, Gurez Including Electric Part
BOQ
| Sl. No. | Item Description |
| 1 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 2 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns etc.for mass concrete. |
| 3 | Providing hosting and fixing trusses/purlins/raters/posts/post-plates or like components including cost of screws etc.kd wood incl.carriage complete job. |
| 4 | 12mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand). |
| 5 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 6 | Providing /Fixing 4mm thick float glass panes,including beading,nails and cost of carriage complete job. |
| 7 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications:Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture |
| 8 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm). |
| 9 | Supply/laying of 16mm dia HDPE 100mtr pipe roll of standard make,designed for efficient water distribution in agricultural and gardening puposes and drip irrigation with nominal wall thickness of 1.2mm. |
| 10 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete. |
| 11 | Dismantling tile work in floors/Walls and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm. |
| 12 | Providing and laying Ceramic glazed anti skid floor tiles 600x600mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS:15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 13 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. |
| 14 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality Jaguar/hindware make conforming to IS : 8931. |
| 15 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. Rectangular shape 453x357 mm. |
| 16 | Engagment of Carpenter for repairment of Roof Truss, old furniture beds, chairs, tables, kitchen wadroom all complete job. |
| 17 | Engagment of plumber and labour for reparing of drinking water supply pipes and procurement of necessary required fittings all complete job. |
| 18 | Supplying and installation of window crewel curtains of premium quality with all fittings hooks, steel rod all complete job (size: 7.5' x 4'). |
| 19 | Carriage of materials by way of mechanical means including loading, unloading and stacking of materials at site.Sand/aggregate 20mm Avg.lead of 45km. |
| 20 | Cement Avg.lead of 45km. |
| 21 | ElectrificationSupply/Fixing of lighting point wth wiring of (P+N)2x 1.5 sq.mm FRLS-HPVC insulated multi strand copper conductor single core cable (of Polycab / Havells / Anchor or equivalent make) with 01 No. of 6 Amp. Modular Switch, Modular plate, cover in front and suitable Gl box of ISO/EC certified of Polycab/ Havells/Anchor or equivalent make as approved before execution of work, incl cost of required conduits/channeis (Polycab /Havells /Anchor make) either recessed in slab/wall of surface mounted Point taken to Distribution board duly tested and commisioned etc.all complete as directed by EIC. Note- All items included like conduits, GI box,Wire,switches, modular plate and cover etc. |
| 22 | Wiring for Power Plug with (P+N+E) 3 x4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Anchor/Eq Make). |
| 23 | Supply/Fixing of Heating point with wiring for power plugs of (P+N) 2 x4.0 sq.mm FRLS-H PVC insulated multi strand copper conductor single core cable (of Polycab / Havells / Anchor or equivalent make) including providing and fixing of 6 pin 5/6 & 15/16 A moduar socket and 15/16A modular switch, Modular plate, cover in front, suitable Gl box ISO/IEC Certifed and necessaryconnections etc. as required, of Polycab / Havells / Anchor or equivalent Make & shall be approved before execution of work, incl cost of required conduits/channels(Polycab/Havells/Anchor make) either recessed/surface mounted. Point taken to Distribution board duty tested and commisioned etc all complete as directed by EIC.Note- All items included like conduits, GI box,Wire,switches, modular plate and cover etc |
| 24 | Providing/fixing/Testing and Commissioning of 6Amp to Amp Rating SP.240v,C Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections. (L&T/Siemens/Lcgrand/Havells/ABB/Eq.Make). |
| 25 | Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V,C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections.(L&T/Siemens /Legrand/Havells/ABB/Eq Make).63 Amp. |
| 26 | 40 Amp. |
| 27 | 100 Amp. For Main Supply. |
| 28 | Supplying and Fixing of MCB way 12 way, horizontal typed, sheet steel, Double Door Distribution Board, SPN 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc, as required.(L&T/Siemens/Legrand/ Schneider/ABB/Eq Make) |
| 29 | Supply/installation/Testing and Commissioning of 18W LED Conceal (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 Im/W with Pressure Die cast Aluminium Heat Sink & P.F>0.95, THD<10%, CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V.The Fixture should have In-built Surge Protection of 2kV.Certification:-LM79 & LM80 teste pont should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/Havel's/Wipro/Halonix/Eq Make. |
| 30 | Fixing of IKO8 IP-66 protected high power LED 50 Watt flood system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 walt each. Integrted potted driver as a unique BIS R number having efTicieney more than 85% and in compliance to BIS certified and Trade mark certiliente.The System level Luminaire efficacy >=125 Imwt. LED driver Input Vollage AC 120 to 270V AC with High voltage CutofY @>-300 V AC and Auto resetting Safety Power Factor >0.95.THD()<10%,driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs.Electrical Conneclor, Surge Protection Min >=4KV intemal and 10KV external but inside drive for compartment, System life of 50000 Buming hours with 70% of Initial Lumens maintained,CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures.(LM79/LM80) Certificate/ report with liable warranty of producv/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Anncxure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning Mhanding over of site to intending department. Havells/Philips/Wipro/Halonix/Eq.make |
| 31 | Supply/Laying/Connecting and Commissioning of 35 sq.mm 2-Core XLPE/PVC insulated and un-armoured 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to 1S: 14930 Part-I and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution) |
| 32 | ENVIRONMENTALLY SAFE MAINTENANCE FREEPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve earth Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man-hole cover for the above. Ineluding cost of 20MM wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job. |
| 33 | Supply and fixing of Hylum sheet (phenolic laminated sheet), 3 mm/ 6 mm/ 10 mm thick (as specified), duly cut into required size and shape, fixed with necessary nuts, bolts, 200 screws,washers, spacers etc., including finishing and making good the surface, complete as required. |
| 34 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H PVC insulated copper conductor, single core Cable in surface /Recessed medium tlass PVC conduit (Havells/Anchor/ Eq.Make)& shall be approved before execution of work (Including Cost of ConduivChannel) 2X10 sq.mm+1 X 6 sq. mm earth wire. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysJul 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender