Housing Urban and Rular Development Government Departments Closing in 16 days TDR #56331006

Tender For Construction Of Dilapidated Building At Govt Middle School Mindrana Edu Zone Drabshalla District Kishtwar Under Samagra Head

Issued by Government Departments · Kishtwar, Jammu and Kashmir
Tender Value
45.77 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
16 days left
EMD
91540
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kishtwar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Dilapidated Building At Govt Middle School Mindrana Edu Zone Drabshalla District Kishtwar Under Samagra Head

BOQ

Name of Work:- CONSTRUCTION OF DILAPIDATED BUILDING AT GOVT MIDDLE SCHOOL MINDRANA EDU ZONE DRABSHALLA DISTRICT KISHTWAR UNDER SAMAGRA HEAD
Sl. No. Item Description
1Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet
2Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 meters lead.
3Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead :Of sectional area 40 sqcm. and above.
4Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and below
5Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In lime mortar
6Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead :Of area of 3 sqm. and below
7Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil :
8Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge:Ordinary Rock
9Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:. Ordinary Rock.1 meter from cutting edge
10Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:. Ordinary Rock.1 meter from cutting edge
11Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
12Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. Allworks upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
13Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with:Cement mortar 1:6 (1 Cement : 6 coarse sand) Nallah Labour rate
14Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
15Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
16Random Rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including levelling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) and curing complete at window sills, ceiling level and the like: Cement mortar 1:6 (1 Cement : 6 coarse sand) Nallah
17Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Second class Kail wood
18Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
19Providing 40x5 mm flat iron hold fast 40 in long including fixing to frame with 1Omm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size )
20Providing and fixing 35 mm thick panelled or panelled and glazed shutters for doors, windows and clerestory windows including lSI marked M.S. pressed Butt hinges bright finished of required size with necessary screws excluding panelling which will be paid for separately,all complete as per direction of engineer- in charge. Second class Kail wood
21Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.coir veneer board (conforming to IS 14842) (12 mm thick)
22Providing and fixing 35mm glazed shutters for doors, windowsand clerestory windows using 1Okg/sqm (4mm thick) float for glass panes including lSI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class Kail wood
23Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:Budloo/ Fir wood 50x12mm
24Centering and Shuttering including strutting, popping and removal of form work for Foundations: footings, bases of columns
25Centering and Shuttering including strutting, popping and removal of form work for Lintels, beams, plinth beams, girders, bressumers and centilevers.
26Centering and Shuttering including strutting, popping and removal of form work for Columns, pillars, piers, abutments, posts and struts.
2720 mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand)
2815mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand)
296 mm cement plaster to ceiling of mix 1 : 3 (1 cement: 3 fine sand)
30Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 25mm thick with 12.5 mm nominal size stone aggregate.
31Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigmentsetc. complete Size of tile 600x600 mm
32Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) :Natural colour insulating board. 12mm thick
33Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position : Badloo /far wood
34Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
35Providing corrugated G. S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whereever required. 0.50 mm thick with zinc coating not less than 275gm/m2
36Providing ridges or hips of width 60cm overall width plain G.S.sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G. I. limpet and bitumen washers complete 0.63 mm thick with zinc coating not less than 275gm/m2
37Providing and fixing plained eaves boarding 2nd class kail wood 250x32 mm (nominal size)
38Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
39Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
40Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
41Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm
42Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to steel windows by welding
43Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
44Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggreagate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. Aggregates.
45Providing and fixing aluminium sliding door bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300x16 mm
46Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :100 x 10 mm
47Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :200 x 10 mm
48Providing and fixing aluminium hanging floor door stopper lSI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete
49Providing and fixing Aluminium handels ISI marked anidized (anodic coating) not less than grade AC 10 per IS 1868) transpaent or dyed to required colour or shade with nuts and screw etc complete 125mm
50Providing and fixing Aluminium handels ISI marked anidized (anodic coating) not less than grade AC 10 per IS 1868) transpaent or dyed to required colour or shade with nuts and screw etc complete 100mm
51Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, mo suitable size M.S box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
52Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, mo suitable size M.S box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
53Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in Existing surface/Recessed medium class PVC conduit as required.2X2.5 SQ.MM +1X2.5 SQ. MM EARTH WORK
54Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in Existing surface/Recessed medium class PVC conduit as required.2X6 SQ. MM + 1X6 SQ. MM EARTH WORK
55Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in Existing surface/Recessed medium class PVC conduit as required.2X1.5 SQ.MM + 1X1.5 SQ.MM
56Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in Existing surface/Recessed medium class PVC conduit as required.10 Amps
57Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in Existing surface/Recessed medium class PVC conduit as required.16 Amps
58Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in Existing surface/Recessed medium class PVC conduit as required.25 Amps
59Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required.
60Supplying and fixing two module Stepped Type Electronic Fan Regulator on the existing Modular Plate Switch Box including Connections but Excluding Modular Plate etc. as Required
61Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.
62Supplying,Installation ,Testing and Commissioning of Single Pole 415V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required.25 Amps
63Supplying,Installation ,Testing and Commissioning of Single Pole 415V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required.16 Amps
64Supplying,Installation ,Testing and Commissioning of Single Pole 415V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required.10 Amps
65Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc as required. (But without MCB/RCCB/Isolator)12 way, Double door
66Supplying and Laying of B-Class 100 mm Dia size G.I Pipe under the Road/Floor not less than 1 mtr. Below the Ground level including cutting the road/floor and making good the same as required.
67Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THO less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
689 Watt LED light havells LED 6600K
69Under Ground Cables and AccessoriesSupplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conformingto IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refillingthe trench but excluding sand cushioning and protective covering etc.,complete as required. 160mm/135mm
70Carriage of cement by Mechanical Transport & manual labour including loading , unloading & stacking complete lead upto 10 km & 500 mtr
71Carriage of sand by Mechanical Transport & manual labour including loading , unloading & stacking complete lead upto 25 km & 500 mtr
72Carriage of stone aggregates by Mechanical Transport & manual labour including loading , unloading & stacking complete lead upto 20 km & 500 mtr
73Carriage of Stones above 40mm size by manual labour including loading , unloading & stacking complete lead upto 300 mtr
74Carriage of Steel by Mechanical Transport & manual labour including loading , unloading & stacking complete lead upto 10 km & 500 mtr
75Carriage of good earth/mulba by manual labour including loading , unloading & stacking complete lead upto 400 mtr
76The Contractor shall submit soil bearing capacity, Analysis, Structural Design and vetting of Structural Drawing from IIT/NIT/Design Directorate well before the execution of works. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56331006
AUTHORITY Government Departments
TENDER VALUE 45.77 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Dilapidated Building At Govt Middle School Mindrana Edu Zone Drabshalla District Kishtwar Under Samagra Head
Basic Detail
Tender No e-NIT No. 30 of 2026-27 Dated 06-07-2026
Bidding Type Tender
Location
City Kishtwar
State Jammu and Kashmir
Key Dates
Publish Date 06 Jul 2026
Submission Date 28 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 45.77 Lakhs
Tender Fee 600
EMD 91540
Exemption Not Available
Document List
5d2df6a7-213c-48e6-81e2-4e30c681641c.html
BOQ_1019690.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

5d2df6a7-213c-48e6-81e2-4e30c681641c.html

xls

BOQ_1019690.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender