Tender For Remodelling Of Hss Pogal Under Capex Budget 2025-26 (Ut Sector)
Tender Value
4.02 Crore
Estimated cost
Bid Submission
27 Jul 2026
14 days left
EMD
8.04 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ramban → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Remodelling Of Hss Pogal Under Capex Budget 2025-26 (Ut Sector)
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 2 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet |
| 3 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead : Of sectional area 40 sqcm. and above. |
| 4 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and below |
| 6 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm indepth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 7 | Providing and laying Stone soling hand packed incl ramming, watering etc cjob |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) |
| 9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. (Back filling) |
| 10 | Back filling of GSB / RBM in layers including rolling / compacting / ramming and watering incl all carriage upto site of work complete Job |
| 11 | Supply and filling of stone dust including laying, watering, compaction complete Job |
| 12 | Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand) Quarry |
| 13 | Dry random rubble masonry with hard stone in foundation and plinth: With bond stone. Quarry |
| 14 | Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete. |
| 15 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto Plinth Level |
| 16 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level |
| 17 | Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein |
| 18 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 19 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in- charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 20 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colou r& pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 16.93.1 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations: footings, bases of columns etc. for mass concrete. |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform. |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, pillars, piers, abutments, posts, and struts. |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for : Stairs (excluding landings) except spiral staircases. |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 28 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 29 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation/ plinth & superstructure above plinth level upto floor five level including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 30 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 31 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): second class kail wood |
| 32 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 33 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. second class kail wood (35mm Thick) |
| 34 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick second class kail wood |
| 35 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.second class kail wood 35 mm thick |
| 36 | Providing and fixing 35mm thick wire guaze shutter using galvanized M.S wire gauze of average width for aperture 1.4m in both directions of wire dia 0.63mm for door,windows and clerestory windows with ISI marked M.S pressed butt hinges bright finish of required size mecessary screws as per directions of EIC second kail wood |
| 37 | Providing and fixing 3.5mm including cost and fixing wooden fillets/ beeding of required size and shape with nail incl all carriage complete |
| 38 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm |
| 39 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 200 x 10 mm |
| 40 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 100 x 10 mm |
| 41 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125mm |
| 42 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 100mm |
| 43 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Single rubber stopper |
| 44 | Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive and other allied fixing material to fix it properly on base complete job |
| 45 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600 mm x 600 mm |
| 46 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600 mm x 600 mm (anti-Skid) |
| 47 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes reparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 48 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 49 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (18mm Thick) |
| 50 | Providing edge moulding to 18 mm marble stone /granite stone counters, Vanities etc.including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge (Granite Work) Double moulding |
| 51 | 6 mm cement plaster of mix :1:3 (1 cement: 3 fine sand) |
| 52 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 53 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand). |
| 54 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. ( 2mm Thick) |
| 55 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 56 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (Two Coats) |
| 57 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 58 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). |
| 59 | Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade. Two or more coats on new work. |
| 60 | Finishing with epoxy Paint (Two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc complete on concerte work (Kerb stone) |
| 61 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 62 | Making plinth protection with common burnt clay bricks of class designation 7.5 laid on edge in cement mortar 1:6 (1 cement : 6 coarse sand) with 12 mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) over 75 mm bed of dry brick aggregate 40mm nominal size rammed, consolidated and grouted with fine sand. The top of bricks pointed with cement mortar 1:3 (1cement: 3 fine sand) and curing complete |
| 63 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position including welding etc and applying a priming coat of approved steel primer all complete. Welded |
| 64 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 65 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including all lifts,leads and carriages complete job |
| 66 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 67 | Providing valleys of 90cm wide overall in plains G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G I. limpet and bitumen washers complete.1.25mm thick with zinc coating not less than 350gm/m2 |
| 68 | Providing and fixing plained eaves boarding. wood 2nd class Deodar wood 300x40 mm (nominal size) complete job 300X40mm |
| 69 | P/F 12mm thick imported wood as soffit including cost of frame work of KD wood underneath of required size as per directions of EIC including cost of primer and paint one or more coats involving all cost of labour,carriage, material , scraffolding cjob (Item to be executed as per directions of EIC) |
| 70 | Construction of soakage pit of ready made RCC rings having 6'-0\\" diameter and 10'-0\\" depth including cost of material, labour, excavation, incl cost of RCC slab 0'-6\\" thick all complete job |
| 71 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. W.C. pan with ISI marked white solid plastic seat and lid |
| 72 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 73 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 74 | providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer-in-charge |
| 75 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia |
| 76 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40mm C.P. brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the walls wherever required :Size 450x300x150 mm |
| 77 | Providing and fixing uplasticized PVC connection pipe with brass unions 45 cm length 15 mm nominal bore |
| 78 | Providing and fixing toilet paper holder : CP Brass |
| 79 | Providing,Fixing,testing and commissioning of CP brass twin coat hook with concealed screws. |
| 80 | Providing and Fixing Health Faucet 15mmdia with CP flush pipe, CP nozzel hook complete including CP flange etc. |
| 81 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 82 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 83 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 84 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 85 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 86 | Providing and fixing UV stabilised UPVC pipes, Type B as per IS:13592 for soil, waste, rain water and vent, including all fittings with or without access i.e Clean out plug,bends, junctions, cowls, offsets, couplers, connectors, heavy duty Metal pipe clamps with rubber seal/clips//holders etc. and jointing with heavy duty solvent cement, complete as per manufacturer's specifications and making good the same, complete as directed by the Engineer-in-Charge. (vertical pipes can be jointed through rubber O rings) Inclouding cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate, 20 mm down gauge) 75 mm in bed and all around soil and waste pipes under floor, including shuttering and centering for: 75mm outer dia. |
| 87 | Providing and fixing UV stabilised UPVC pipes, Type B as per IS:13592 for soil, waste, rain water and vent, including all fittings with or without access i.e Clean out plug,bends, junctions, cowls, offsets, couplers, connectors, heavy duty Metal pipe clamps with rubber seal/clips//holders etc. and jointing with heavy duty solvent cement, complete as per manufacturer's specifications and making good the same, complete as directed by the Engineer-in-Charge. (vertical pipes can be jointed through rubber O rings) Inclouding cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate, 20 mm down gauge) 75 mm in bed and all around soil and waste pipes under floor, including shuttering and centering for: 110mm outer dia. |
| 88 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. for 100mm dia pipe |
| 89 | Providing and fixing multi inlet uPVC floor trap with minimum 50mm water seal of self cleaning design with 110 mm outlet consisting of all necessary fittings and provding strainer of 150 x 150 mm square stainless steel 2 mm thk frame with slotted lockable grating on top of the trap level matching the level of floor finish etc, complete including cost of cutting and making good the walls and floors wherever required and as directed by Engineer in charge. (The inlet diameter shall be 32mm, 40mm or 50mm as per site requirements) |
| 90 | Providing and fixing uPVC pipe as per IS 4985, Class-3, 6Kg/cm2 with cement solvent joint, complete with all fittings and clamps etc including cutting and making good the walls and floors for waste pipes from wash basins, urinals, sinks & balcony drainage, as directed by the Engineer-in-charge. 32 mm OD |
| 91 | Providing and fixing uPVC pipe as per IS 4985, Class-3, 6Kg/cm2 with cement solvent joint, complete with all fittings and clamps etc including cutting and making good the walls and floors for waste pipes from wash basins, urinals, sinks & balcony drainage, as directed by the Engineer-in-charge. 40 mm OD |
| 92 | Providing and fixing uPVC pipe as per IS 4985, Class-3, 6Kg/cm2 with cement solvent joint, complete with all fittings and clamps etc including cutting and making good the walls and floors for waste pipes from wash basins, urinals, sinks & balcony drainage, as directed by the Engineer-in-charge. 50 mm OD |
| 93 | Providing and fixing SS grating with frame including fixing to the floor with cement mortar. 100 mm dia |
| 94 | Providing and fixing 110mmx50mm outlet. UPVC floor drain consisting of all necessary fittings and provding strainer of 150 x 150 mm square stainless steel 2 mm thk frame with slotted lockable grating on top of the trap level matching the level of floor finish etc all complete as per specifications and direction of Engineer-In-Charge. |
| 95 | Providing & fixing of cast brass clean out plug(floor/ceilling) with suitable insert keys for opening in: brass cap, male threaded joint with threaded G.I socket fixed to HCI soil pipe or C.I.(LA) pipe joints as required complete in all respects 110mm outer dia. |
| 96 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in charge Internal work-exposed on wall with clamps at 1.00 meter spacing |
| 97 | PN-16 pipe, 16mm OD(SDR-7.4) |
| 98 | PN-16 pipe, 20mm OD(SDR-7.4) |
| 99 | PN-16 pipe, 25mm OD(SDR-7.4) |
| 100 | PN-16 pipe, 32mm OD(SDR-7.4) |
| 101 | PN-16 pipe, 40mm OD(SDR-7.4) |
| 102 | PN-10 pipe, 50mm OD(SDR-11) |
| 103 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in chargeInternal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 104 | PN-16 pipe, PN-16 pipe, 25mm OD(SDR-7.4) |
| 105 | PN-16 pipe, 32mm OD(SDR-7.4) |
| 106 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 107 | 15 mm nominal bore |
| 108 | 20 mm nominal bore |
| 109 | 25 mm nominal bore |
| 110 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) |
| 111 | 32 mm nominal bore |
| 112 | 40 mm nominal bore |
| 113 | 50 mm nominal bore |
| 114 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 115 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. Metre |
| 116 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete |
| 117 | 150 mm dia. R.C.C. pipe |
| 118 | 250 mm dia. R.C.C. pipe |
| 119 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating Brick block masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180x150 mm size P type With Sewer Brick block conforming to IS : 4885 |
| 120 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885 |
| 121 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated asper IS: 10910 on 12mm dia steel bar conforming to IS :1786 having minimun cross section as 23 mm x 25 mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and heaving manufacture\\"s permanent identification mark to be visible even after fixing \\" incluting fixing in manholes with 30x20x15 cm cement concrete block 1:3:6: (1 cement :3 coarse sand :6 graded stone aggregate 20mm nominal size )complete as per design. |
| 122 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc complete. For pipes 250 to 300 mm diameter |
| 123 | Constructing brick masonry road gully chamber of specified size with common burnt clay(non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including precast R.C.C. horizontal grating with frame complete as per standard design: Chamber size 50x45x60 cm including precast R.C.C grating with frame 500x450 mm horizontal grating. |
| 124 | Supply and installation of following types of extinguisher with provision of wall bracket (fixed with anchor fastner) ABC Stored Pressure type Fire Extinguisher 6 Kgs. capacity bearing ISI Mark for Fighting ABC Class of Fire. The Extinguisher will be Manufactured Strictly as per BIS: 15683:2006 bearing ISI. mark. EN3 615 Approved Powder. ABC 87% MAP. Complete with all accessories 6 Kg |
| 125 | Co2 type Fire Extinguisher 4.5Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Squeeze Grip type valve with initial Charge as per IS: 15683:2006 specification, bearing ISI Mark . 4.5 Kg |
| 126 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 127 | Wiring for Light / Power Plug with 2X4 Sq.mm FRLS / HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 No 4 Sq. mm FRLS / HFFR PVC insulated copper conductor single core cable for loop earthing as required |
| 128 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 129 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 130 | 2 X 6 sq. mm +1 X 6 sq. mm earth wire |
| 131 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 132 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 133 | Supplying and drawing of following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 1 X 1.5 Sq.mm |
| 134 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 135 | Supplying and fixing of following sizes of medium switch / socket on the existing modular plate & Switch box including connecitons but excluding modular plate etc as required 5/6 A Switch |
| 136 | 3 pin 5/6 A socket outlet |
| 137 | 15/16 A switch |
| 138 | 6 pin 15/16 A socket outlet |
| 139 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 140 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 141 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 142 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 143 | Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 144 | 1 or 2 Module (75mm × 75mm) |
| 145 | 4 Module (125mm × 75mm) |
| 146 | 6 Module (200mm × 75mm) |
| 147 | 8 Module (125mm × 125mm) |
| 148 | Supply and erection of sheet metal Double Door Distribution Boards IP 43–IK09 metal door (dust protected) as per IS 8623-1 & 3, IEC 61439-1 & 3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/RCBOs/RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/RCCB's/RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/FP MCB's/RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc. 6 way (4+18), (Double door) (TPN type) |
| 149 | 8 way (4 + 24), Double door |
| 150 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, DIN bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door |
| 151 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement), 4 kV impulse withstand voltage, ISI marked IS 8828 (1996) / conforming to IEC 60898-1:2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35 sq.mm conductor, line load reversibility, IP20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 up to 20 A rating and 10,000 up to 63 A, 5,000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submitted NABL/CPRI/ERDA accredited lab type test reports & all as pre-approved by Engineer-in-Charge. |
| 152 | Single pole 6/10/16/32 Amp |
| 153 | Single pole and neutral 63 Amp |
| 154 | TPN 63 Amp |
| 155 | Supplying & fixing of LED Batten Tube fitting 600 mm size 10/11 watt Aluminium housing with 1000 Lumens and minimum luminous efficiency 100 lumens/watt, P.F. > 0.90. |
| 156 | Supplying, installation, Testing & Commissioning of 18–22 watt LED surface mounted Batten Light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver Efficiency >85%, Operating voltage AC 140–270 Volt, frequency 50/60 Hz, Operating temperature range -15°C to 40°C, internal surge protection of 2.5 kV with Short & Open circuit protection, THD <10%, P.F. ≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry) of minimum 50,000 Burning Hours with 70% of initial lumen maintained till life ends, CCT 3000K/4000K/5700K/6000K/6500K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3. Maximum power consumption should not be more than the specified rating and fixture shall be of relevant BIS standard and bear trade mark certificate (T.C.). Manufacturers Word Mark/Name Engraved/Embossing/Screen printing on housing. Complete in all respect including connections with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/W output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape, size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/Extruded aluminium Body (Thickness ≥1.20 mm). |
| 157 | LED Down lighter (SMD Type) (System lumen efficiency ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/Surface Down lighter (Round/Square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%. Operating voltage AC 140–270 Volt, Frequency 50/60 Hz, Operating temperature range -5°C to 40°C, internal surge protection of 2.5 kV with Short & Open circuit protection, THD <10%, P.F. ≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (Flicker should be below 5%), life time (LED, Driver & electrical circuitry), life of minimum 50,000 Burning Hours with 70% of initial lumen maintained till life ends. CCT 3000K/4000K/5700K/6500K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3. Maximum power consumption should not be more than the specified rating and fixture shall be of relevant BIS standard. Manufacturers Word Mark/Name Engraved/Embossing/Screen printing on housing. Complete in all respect including external connections with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 year OEM warranty. System lumen efficiency ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape, size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/Extruded aluminium 18 Watt |
| 158 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 159 | Supply, installation, testing and commissioning of Ceiling Fan 3 Star Rated with voltage range 90 V to 300 V, minimum air delivery 212 CMM, service value 5.3 Cu.m/min/Watt, aluminium blades, including wiring the down rods of standard length (up to 45 cm) with 1.5 sq.mm FR PVC insulated copper conductor single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1200 mm |
| 160 | Exhaust Fan 300 mm size (Metallic) |
| 161 | LED Street Light Fixture, powder coated pressure die-cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt).Supplying, installation, testing & commissioning of Street Light LED Fixture, powder coated pressure die-cast aluminium body with driver as per the requirement with driver efficiency >85%. Input voltage: 140–270 Volt AC, frequency 50/60 Hz. Operating temperature range: -5°C to 50°C, internal surge protection of 5 kV L, N, E as per IEC 61000-4-5. Driver efficiency >85%, THD <10% as per IEC 61000-3-2, P.F. ≥0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI/EMC as per CISPR-15, lenses for beam angle as per IESNA Type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65 mm dia pipe. Lifetime (LED, Driver & electrical circuitry) of minimum 50,000 burning hours with 70% of initial lumen maintained till life ends as per LM80 extrapolation/IES TM-21-11 report. CCT 3000K / 4000K / 5700K / 6500K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5. Maximum power consumption shall not be more than the specified rating and fixture shall be of relevant BIS standard, complete in all respects including external connections with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5-year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test Reports and all testing required for LED fixtures as per BIS shall be submitted. Shape, size and CCT shall be as approved by Engineer-in-Charge as per requirement. Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C.) 100 Watt |
| 162 | Earthing with copper earth plate 600 mm × 600 mm × 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. |
| 163 | Providing and fixing of 25 mm × 5 mm copper strip on surface or in recess for connections etc. as required. |
| 164 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 165 | SITC of wall/Free Standing Floor Mounted Dust and Vermin Proof Compartmentalized Cubicle Panel for Electrical Works, made out of CRCA sheet. Other parameters required as per point:(a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment having bolted type doors with/without detachable extension type structure.(b) Panel shall be duly treated for derusting in 7 tank process with de-phosphating and with powder coating of minimum 70 microns on both sides of panel in desired shade. The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness, required hardware, separate detachable gland plate, M.S. base channel (minimum 75 mm), hinged door with locking arrangement for equipment/switchgear.(c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (up to 125 Amp) and by solid bus bar (>125 Amp).(d) Only outer area on all sides shall be measured and panel to be fabricated only from CPRI approved fabricator. CPRI Test Certificates to be submitted. All as per pre-approved by Engineer-in-Charge. |
| 166 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) 200 Amp, 36 KA, FP MCCB, ICU = 100% ICS |
| 167 | ON Load Change Over Switch FP 100 Amp. (Front operated) |
| 168 | Aluminium Bus Bar 200 Amp set of 4 strips 18\\" |
| 169 | Aluminium Bus Bar 300 Amp set of 4 strips 18\\" |
| 170 | Digital Metering Devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 171 | Supplying & laying of PVC insulated and PVC sheathed/XLPE Aluminium power cable of 1.1 KV grade of following size on surface/direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Armoured cable) 95 sq. mm, 3.5 Core |
| 172 | Online UPS –Input Supply: Single PhaseOutput Supply: Single PhaseSupplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, Inverter, battery bank suitable for 30 minutes backup (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per hour backup time) on full load. Battery shall be VRLA, SMF in ABS Container and Static Bypass Switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS system shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBTs) both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. |
| 173 | The quality of design, manufacturing and inspection process should conform to the relevant International standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current Total Harmonic Distortion (ITHD) / Total Demand Distortion (TDD) on the input grid shall be <5% at 100% load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be included to limit the input P.F. to 0.99 and output power factor shall be unity (i.e., kVA rating of the UPS shall be kVA rating × 1). However, UPS shall be suitable to take load at 0.7 lagging to 0.7 leading power factor loads.UPS shall be suitable for incoming supply AC single phase 160–270 V, 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volts, 50 Hz ±0.2 Hz. Overload capacity of 120% for 10 minutes and 150% for 1 minute. Operating temperature 0°C to 40°C, Relative Humidity 0–95% non-condensing, noise level less than 60 dB at 1 meter distance. Protection for under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge, 10 kV surge.Display for Watt/VA, Amp and Voltage power parameters etc. |
| 174 | UPS shall comply with low voltage Electromagnetic Compatibility (EMC) achieved as per EN 62040, EN 62040 Part 1 and Part 2. It shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3). The UPS should be with IGBT Based Inverter Technology. Communication RS232 / RS485 / SNMP port open protocol for BMS integration as approved by Engineer-in-Charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories shall be inclusive in the cost. The UPS should have QR Code which should contain drawing, test report, OEM manual, Geo-Tag of manufacturing location etc. 10 KVA |
| 175 | Supplying, Installation, Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc.:-1. Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB. Camera should display Camera title, Date & Time in live & recorded video. 2. Image Sensor: 1/2.8\\" or better Progressive Scan CMOS to get colour image even at night condition (Minimum Illumination: 0.006 Lux @ F1.4, AGC ON, 0 lux with IR or better). True Day & Night, High Performance Mechanical IR Cut Filter with auto switch, Integrated IR Source (Auto, Manual), Inbuilt IR LEDs with effective distance up to 50 metre or better and 30 metre for colour view in night. Imaging: 1/3 s to 1/30000 s electronic shutter support, Auto Gain Control, White Balance: Auto, Back Light Compensation, Multi-zone Privacy Masking, HLC, Digital Watermarking. 3.Compression (Minimum): Video: H.265 or better, H.264H, H.264 Audio: G.711U/A, G.711Mu, G.726, AAC, G.723 4. Wide Dynamic Range: WDR (120 dB or more). 5. Digital Noise Reduction: DNR (3D) On/Off. 6. Video Streaming & Frame Rates: Triple streaming, configurable. Main stream: 2 MP (1920 × 1080) @ 25/30 fps. Sub streams minimum: 720P @ 25/30 fps. 7. Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser. Edge Analytics: Tripwire, Intrusion, Motion Detection. |
| 176 | 8. Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot.9. Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot up to 512 GB. It should be supplied with minimum 128 GB memory card.10. Recording Management: Format SD, event/video, storage management, video to NAS device. |
| 177 | 11) Alarm Trigger: Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection.12)Network Protocol: SFTP, IPv6, IPv4, DNS, RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast.13)System Capability: ONVIF, Camera shall support open source VMS.14)Ethernet: 1 RJ45 10/100 Ethernet port.15)Audio: It should support 1 × Built-In Mic and 1/1 Alarm In/Out for External Mic. and Speakers as per site requirement.16)Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.17)Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE.18)Housing/Enclosure: IP67 weather proof, IK10, Metallic body.19)Operating Condition: Ambient Temperature: (-)05°C to 50°C, humidity 95% (max) (non-condensing).20)IR life: 40000 hours or higher.21)Video Bit rate: 32 KBPS - 8 MBPS or better.22)Standards: BIS with ER, STQC Certified, CE, FCC and RoHS.2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/3.6mm fixed lens |
| 178 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc. as mentioned below:1)Network Video Recorder: Embedded/Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth. |
| 179 | 2)NVR should support H.265 or better, H.264, MJPEG, MPEG4 support.3)Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk.4)Intelligent auto power on when power resumes after power outage.5)Storage: It should support minimum 2 SATA Slots with 20TB capacity/Slot.6)Connectivity Interface: 1 Nos. × 10/100/1000 Mbps Ethernet Port, 1× RS485, 1× RS232.7)Backup Interface: It should have 2 Nos × USB port (1× USB3.0, 1× USB2.0).8)Video Output Ports: 1× HDMI and 1 VGA.9)Alarm Ports: It should have 4/1 Ch In/Out ports to connect various types of external sensors and output devices like hooter/siren etc.10)Email & SMS Alert options: Option for SMS/Email Alerts to minimum 5 designated mobile numbers for power failure, HDD failure, vandalism, tampering, network disconnection and panic. |
| 180 | 11)Web & Mobile Application: Web, Mobile app (For iPhone, iPad, Android Phone) for alerts and viewing.12)Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13)Standards: CE, FCC, RoHS and BIS Certified.14)Power Supply: Should support 12VDC, 4Amp or AC100–240V, 50/60Hz Power supply.15)Operating Condition: Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing).16)The VMS, NVR application shall support all the features & functionalities of the offered cameras.17)VMS should consist of Base License and Channel Licenses. VMS should be provided with camera Licenses, with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18)The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. |
| 181 | 19)The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20)Must support Resolution: 7680×4320 (8K), 3840×2160, 1920×1080, 1280×1024, 1280×720, 1024×768.21)Must support recording resolution up to 32MP.22)Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode.23)When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page.24)The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm.25)It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one AVI/MP4 file.26)General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection). |
| 182 | 27)Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, Face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan.28) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. |
| 183 | 29) Built-In Artificial Intelligence: NVR should have built-in AI:2 Channel face detection and recognition.Minimum 4 Channel perimeter protection.Minimum 8 Channel Smart Motion Detection.30)Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec.31)Face & Human Attributes Search: Search Pictures/Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.32)ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc. vehicle attributes. |
| 184 | 33)Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception.34)Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.35)General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection).36)Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency.VCA (Video Content Analytic): Should support multiple video content analytics based on camera analytics.16 Channel Network Video Recorder (NVR) having display split:Main screen: 1/4/8/9/162nd screen: 1/4/8/9/16 |
| 185 | Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under:Minimum 8 × RJ-45 Gigabit Ethernet Ports and additional 2 × 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher.8K MAC table. Internal dual AC Power supply with operating temperature of -5°C to +50°C. Jumbo frame: 10KB or higher. IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave. Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping & MLD Snooping Fast Leave. STP, RSTP, MSTP. Loopback detection, Multicast filtering, VLAN Tagging. QoS: 8 Queue per port, WRR. IPv4/IPv6 Interface: Minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries. 700 Access Control entries. SSH, SSL for IPv4 and IPv6. 802.1x. ARP Spoofing, DHCP Snooping and server screening. IP+MAC+Port Binding. Per Port Bandwidth Control. 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support). Cable Diagnostic feature. LLDP, LLDP-MED. SNTP/NTP. RMON. SNMP v1, v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE. OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India, etc., complete as required. 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+. |
| 186 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/on surface, U/FTP, LSZH, Non-Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy identification should have FLAME PROPERTIES, i.e.:Flammability Test – IEC 60332-1Smoke Density – IEC 61034LSZH standards complianceANSI/TIA-568 C.2ISO/IEC 11801IEEE 802.3anRoHSDelay Skew should be < 45NS.The outer Cable Diameter should be 7.5 ± 2 mm.Cable should have been tested and verified by UL/ETL etc., complete as required.1 Run of cable |
| 187 | RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color. Use for 24–26 AWG stranded wires. |
| 188 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with \\"U\\" Marking.Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color – RAL-7035, complied with UL & RoHS, 2 × 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 × 1 number, etc. complete as required. 6U Rack |
| 189 | Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D, etc. complete as required.Copper Patch Cords of length 1 m (3 ft) |
| 190 | Copper Patch Cords of Length 3 m (10ft) |
| 191 | Supplying of LED TV (Smart TV) UHD 4K 43\\" |
| 192 | Carriage of Material by Mechnical Transport including loading, unloading and stacking at site complete:a. Sand for an avg lead of 85 Km |
| 193 | b. Stone Aggregate below 40 mm for an avg lead of 35 Km |
| 194 | c. Bricks for an avg lead of 100 Kms |
| 195 | d. stones for an avg lead of 35 kms |
| 196 | Carriage of Material by Manual including loading, unloading and stacking at site complete:a. Sand for an avg lead of 300 meter |
| 197 | b. Stone Aggregate below 40 mm for an avg lead of 300 meter |
| 198 | c. Bricks for an avg lead of 300 meter |
| 199 | d. stones for an avg lead of 300 meters |
| 200 | e. Lime Moorum Building Rubbish for an avg lead of 500 mtr |
| 201 | f. Carriage of Mulba for an avg lead of 500 Mtr Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender