Tender For Repair/ Renovation Of Guest House At Nigeen Club.(Adv. Cost Rs. 166.95 Lacs) (Incl Cost Of Material+Gst)
Tender Value
1.66 Crore
Estimated cost
Bid Submission
13 Jul 2026
1 days left
EMD
3.33 Lakhs
Bank guarantee accepted
Document Fee
2600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Renovation Of Guest House At Nigeen Club.(Adv. Cost Rs. 166.95 Lacs) (Incl Cost Of Material+Gst)
BOQ
| Sl. No. | Item Description |
| 1 | Civil Part |
| 2 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m. (stacks of cleaned bricks shall be measured) : From brick work in cement mortar |
| 4 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead :Of area of 3 sqm. and below |
| 6 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead : Of sectional area 40 sqcm. and above. |
| 7 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet |
| 8 | DIMANTLING WOODEN SCANTLING MEMBER IN FLOORS AND CEILING ANDSTACKINGSERVICABLE MATERIAL AT SITE WITHIN LEAD OF 50M |
| 9 | DISMANTLING WOODEN WALL PANELLING BY EMPLOYING MANUAL LABOUR I/C FRAME WORK AND BOARD , I/C STACKING OF SERVICABLE MATERIAL AT SITE WITHIN LEAD OF 50M |
| 10 | DISMANTLING KHATAMBUND CEILING BY EMPLOYING SKILLED KHATAMBUNDLABOUR I/C FRAME WORK AND BOARD , I/C STACKING OF SERVICABLE MATERIAL AT SITE WITHIN LEAD OF 50M |
| 11 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 12 | SUPPLY AND LAYING STONE SOLLING GRADED MATERIAL ( QUARRY) I/C CONSOLIDATION IN LAYERS , I/C COST AND CARRIAGES OF MATERIAL FROM SOURCE TO SITE. |
| 13 | Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete. |
| 14 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 15 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 17 | FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for:Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Suspended floors, roofs, landings, balconies and access platforms. |
| 19 | Stairs (excluding landings) except spiral staircases. Add 40% for Riser sides and tread sides |
| 20 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50mm thk |
| 21 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in 1:4 cement mortar up to level 5 |
| 22 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or withdash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): DEODAR WOOD 2ND CLASS |
| 23 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). 35MM THICKIIND DEODAR WOOD |
| 24 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.DEIODAR WOOD |
| 25 | 12mm Cement plaster on the rough side of single or half brick wall of mix: 1:4 cm |
| 26 | Pointing on brick work or brick flooring with LIME: SURKHI & WHITE CEMENT IN APPROPRIATE PROPORTION I/ C GRINDING THE SURFACE, GROOVING THE BRICK JOINTS AND FILLING SAME WITH RULED POINTING Flush/Ruled/Struck or weathered Pointing |
| 27 | Painting with SATIN paint of approved brand and manufacture to give an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint/ PRIMER of approved brand and manufacture. |
| 28 | Finishing walls with 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/10 sqm. Over & including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 29 | Providing and laying GLAZED vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades,laid WITH POLYMER CHEMICAL WHITE LATICRETE 315 GRADE etc. complete 1200X600 WITH 3MM SPACER FILLED WITH EPOXY RESIN BASED GROUT |
| 30 | Providing and laying GLAZED vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) etc. complete 600X600 WITH 3MM SPACER FILLED WITH EPOXY RESIN BASED GROUT |
| 31 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels 18MM THICK AREA OVER 0.5 SQM Granite of any colour or shade |
| 32 | Providing hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. complete First class Budloo/Fir wood |
| 33 | Labour charges for hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. complete available serviceable material at site after dismantling the wooden trusses |
| 34 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles dulyreinforcedwith 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension,EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) 9.149A.4Casement window single panel with S.S. friction hinges (400 x 19 x1.9 mm) made of (big series)frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) TWIN SASH WINDOWS |
| 35 | Providing and fixing double glazed hermetically sealed glazing in aluminum windows/UPVC , ventilators and partition etc. with 6mm thick clear float glass both side having 12mm air gap including providing EPDM gasket, perforated aluminum spacers, desiccants, silicon sealant (both primary and secondary sealant) etc. as per specifications, drawings and directions of Engineer-in-charge complete. |
| 36 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately. |
| 37 | LABOUR CHARGES FOR FIXING SERVICABLE KHATAMBUND CEILING |
| 38 | P/F 12MM MR GRADE PLY OVER KD WOOD JIOST 2\\"X1.5\\" SPACED AS PER PLY SIZE I/C COST OF NAILS ALL COMPLETE JOB |
| 39 | P/F MR GRADE 12MM PLAY TO PLY FIXED OVER WALLS WITH RAWL PLUG AND SCREWS |
| 40 | WALL PANELLING IN WAINSCOTING USING 18MM HDHMR I/C BEEDING AND FIXING IN POSITION OVER PLUG WITH DRY WALL SCREWS ALL COMPLETE JOB |
| 41 | P/F WOODEN DEODAR 2ND CLASS WAINSCOTING/PANEL OVER WALLS USING 25MM THICK DEODAR IN RAILS AND PANELLS I/C FEVICOL MARINE AND NAILS ALL COMPLETE. BEEDING 25MMX19MM OVER REBATES OF DILLA /PANELL ALL COMLETE AS BY DIRECTIONS BY EIC |
| 42 | P/F 12MM BUDLOO WOODEN PANELLING IST QUALITY ( KASHMIRI BUDLOO WHITE COLOUR ) 4\\", 5\\",6\\" WIDTH WITH V GROOVE ALL COMPLETE JOB |
| 43 | Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineerin-charge. 12.53.1 With Type N-Normal 50 mm thick |
| 44 | P/A POLYURETHANE ( PU) DUCO COATING IN PLALLETE SHADES OVER HDHMR WITH EPOXY INSULATOR UNDER COAT, SURFACER COAT IN 2 COATS, TOP COAT IN 2 COATS WITH SUBSEQUENT SANDING WITH SANDING GRIT NO 80,120,220,400,600 GLASS FINISH. ALL JOINTS TO BE FILLED WITH DUCO PUTTY AND WOODEN FILLER |
| 45 | WOODEN POLISH WITH POLYURETHANE ( PU) WOODEN SEALER, SEMI GLOSS PU TOP COAT WITH SURFACE PREPARATION BY SANDING WITH SAND PAPER GRIT 80,120,220,320,400,600 WITH FILLING WITH WOOD FILLER ALL COMPLETE JOB I/C WOOD STAINER WALNUT DILUTED IN THINNER AND APPLYING ON WOODEN SURFACE |
| 46 | P/A MELAMINE WOODEN POLISH I/C MELAMINE SELAER IN 3 COATS AND MELAMINE TOP COAT IN 3 COATS I/C SURFACE PREPARATION WITH SANDING PAER GRIT 80,120,220,320,400 |
| 47 | French spirit polishing, Two or more coats on new works including a coat of wood filler |
| 48 | Providing, fixing and applying Plaster of Paris (POP) false ceiling consisting of frame work made with 50mm sq M.S. tubes of 18 G thickness as main runner at 600 mm c/c both ways, suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab, finished smooth to line and level including necessary supports, scaffolding etc. as required and also including applying a coat of red oxide zinc chromate primer over the M.S. frame work and suspenders complete. Including providing and fixing expanded metal of size 5.25 mm x 1.25 mm thickness welded to main runners and applying POP (calcium sulphate semi hydrate variety) to the expanded metal of thickness not less than 10 mm |
| 49 | P/F PRECOATED COLOUR COATED CGI TILE PROFILE SHEETING FIXED WITH SELF DRIVEN SCREWS WITH CAP ALL COMPLETE JOB 0.50 MM THICK ( JSW, TATA, INDIAN STEEL) |
| 50 | Providing ridges or hips of width 30cm overall width plain COLOUR COATE sheets fixed with SELF DRIVEN SCREWS 0.50MM THK |
| 51 | Providing valleys of 40cm wide overall inPRECOATED COLOUR CGI SHEETING 0.50MM THK FIXED WITH SELF DRIVEN SCREWS |
| 52 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 53 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in charge. 19.2.2 Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. i/c all fittings PN-16 pipe , 20mm OD(SDR-7.4) |
| 54 | PN-16 pipe , 25mm OD(SDR-7.4) |
| 55 | PN-16 pipe , 32mm OD (SDR-7.4) |
| 56 | PN-10 pipe , 50mm OD (SDR-11) |
| 57 | Providing and fixing PPR Unions PPR Union 20mm |
| 58 | PPR Union 25mm |
| 59 | P/L SWR pipes PVC B- type i/c all fittings and accessories all complete job 150mm I/C COLLARS |
| 60 | 110mm I/C COLLARS |
| 61 | 75 mm I/C COLLARS |
| 62 | p trap |
| 63 | DOOR BEND 110MM |
| 64 | DOOR BEND 75MM |
| 65 | PVC FLOOR TRAP |
| 66 | Constructing masonry Chamber of specified size, in brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 (1cement :4 coarse sand) and R.C.C. top slab 1:1.5:3mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design Chamber 60x60x75 cm |
| 67 | P/F WASH BASIN BELOW COUNTER , OF SIZE 400X600, I/C CP BRASS WASTE COUPLING, SPOUT, BASIN DIVERTOR , BOTTLE TRAP ALL COMPLETE JOB OF SD MAKE JAQUAR |
| 68 | SUPPLY, INSTALLATION , TESTING AND COMMISIONING HOT WATER GEYSER 50 L CAPACITY , RACOLD/VENUS/JAQUAR AO SMITH |
| 69 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 ( JAQUAR MAKE) |
| 70 | P/F SHOWER DIVERTOR WITH TOP PLATE ALL COMPLETE JOB ( JAQUAR) |
| 71 | P/F OVERHEAD SHOWER WITH SHOWER ARM 450TO 600MM LONG ( RAIN SHOWER) JAQUAR MAKE |
| 72 | P/F FLOOR JALLI SS 304 GRADE MATT FINSH 150 MM |
| 73 | P/F pvc connection 24\\"/18\\" |
| 74 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: 32mm dia |
| 75 | P/F WALL HUNG WC 550X380 JAQUAR MAKE ( SQUARE SHAPE) I/C RAKE BOLTS , SEAT ALL COMPLETE JOB |
| 76 | P/F CONCEAL CISTERN FOR WALL HUNG WC ALL COMPLETE JOB ( JAQUAR MAKE)I/C TOP CONTROL PLATE |
| 77 | P/F THERMOSTAT DUECE MIXER FOR CONTROLLED WATER SUPPLY IN HEALTH FAUCET FITTED OVER W/C LEDGER WALL ( JAQUAR) |
| 78 | P/F HEALTH FAUCET I/C SPARY, PIPE AND SPOUT ALL COMPLETE JOB ( JAQUAR) |
| 79 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing rectangular |
| 80 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete15 mm nominal bore |
| 81 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-incharge. |
| 82 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 83 | P/F CP BATH ACCESSORIES ( JAQUAR MAKE)TOWEL RAIL 600MM( JAQUAR) |
| 84 | TOWEL RING 450MM |
| 85 | SOAP CASE SUPEIOR |
| 86 | SOAP DISPENSER |
| 87 | ROBE HOOK |
| 88 | CRAB HANDLE 450MM |
| 89 | P/F WOODEN HAND RAIL ( 75X100) KAIL WOOD WITH WALNUT BALUSTRADES 35\\" HEIGHT 3\\" DIA ALL COMPLETE JOB |
| 90 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. : 200x10 mm |
| 91 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) |
| 92 | Providing and fixing CYLINDRICAL LOCK ( GODREJ/DORSET) |
| 93 | P/F CYLINDRICAL BATH LOCK LATCH ( HETTIC/DORSET) |
| 94 | Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete |
| 95 | Providing and fixing bright finished brass door latch with necessary screws etc. complete. : 9.76.1 300x16x5 mm |
| 96 | Providing and fixing plained eaves boarding. 2ndFIR wood 300x30 mm (nominal size) |
| 97 | P/F of 12mm thick T&G planks made of imported wood (New zealand pine or equivalent) for roof soffits & Ceiling on wood work in false ceiling, partitions sawn and putup in position in budloo wood (Ceiling Joists). including cost of necessary adhesive & cost of nails etc. with necessary cornice of required size complete job. incl cost of nails / screws all complete as approved by Engineer-in-charge (including cost of all material, leads, lifts and carriages etc upto site of work complete). |
| 98 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 99 | Providing and fixing CP Brass Single lever KITCHEN SINK MIXER (a) 15 mm nominal dia |
| 100 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 101 | PROVIDING AND APPLYING BITUFIX DR FIXIT MEMBRANE BY BRUSH OR ROLLER IN 2 COATS FOR DAMPPROOFING/ WATER PROOFING OF WALLS AND FLOOR |
| 102 | P/A DEVRI STONE CLADDING TILE 40MM X 300MMX200MM FIXED OVER CEMENT MORTAR BED 20MM I/C POINTING IN GROOVES 12MM ALL COMLETE JOB |
| 103 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 104 | DISMANTLING OF EXISTING BATHROOM POINTS I/C WC WASHBASIN, GI PIPES, CI PIPES ALL COMPLETE JOB |
| 105 | Providing bricks band 10cm / 7.0 cm thick 5 cm / 5.7 cm projected from wall face, in bricks of class designation 7.5 laid in cement mortar 1:4 (1 cement : 4 coarse sand) and curing complete I/C LIME SURKHI POINTING |
| 106 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2MM THK |
| 107 | P/F LAMINATED WOODEN FLOORING 12 MM OVER 1.5 MM POLY FOAM ( AC4 GRADE) |
| 108 | P/F UNDERPINNING VERTICAL JACKS AND HORIZONTAL RUNNERS FOR SUPPORTING THE TOP STRUCTURE ALL COST COMPLETE JOB AND REMOVAL OF SAME |
| 109 | Carriage of material by Mechanical Transport for average lead of 20 kmStone aggregate 40 mm nominal size and above |
| 110 | Sand, stone aggregate below 40 mm nominal sizeSand |
| 111 | AGGREGATE BELOW 40MM |
| 112 | Bricks |
| 113 | Carriage of material by Manual Labour for average lead of 150mtrsStone aggregate 40 mm nominal size and above |
| 114 | Sand, |
| 115 | Stone aggregate below 40 mm nominal size |
| 116 | Bricks |
| 117 | Steel/CGI Sheets |
| 118 | TIMBER |
| 119 | CEMENT |
| 120 | Electric Part |
| 121 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC Insulated copper conductor (Polycab green/Fenolex/ Havell lifeguard/Salzer/equivalent as directed by engineer incharge.) single core cable in surface / recessed (cutting the wall and making good the same in case of recessed conduit) medium class PVC conduit/ duct( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer Incharge.), with modular switch (Legrand Mylinc /Siemens Marq/schneider Zencelo /Crabtree athena make.), modular plate, sultable Gl box as required. |
| 122 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without Independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor (Polycab green/ Fenolex/Havell lifeguard/Salzer/equivalent as directed by engineer Incharge.) single core cable in surface/ recessed PVC conduit, as required. |
| 123 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire, FRLS PVC insulated copper conductor (Polycab green/Fenolex/Havell lifeguard/Salzer/equivalent as directed by engineer incharge.) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit) medium class PVC conduit (Anchor/Polycab/Ravindra/equivalent make as directed by engineer incharge.) |
| 124 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Modular Switch & Socket:- (Legrand Mylinc/Siemens Marq/schneider Zencelo/Crabtree athena make |
| 125 | Wiring for 6-10 amp power plug/lighting ckt with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Polycab green/ Fenolex/ Havell lifeguard/Salzer/equivalent as directed by engineer Incharge.) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit) medium class PVC conduit ( Anchor/ Polycab/Ravindra/equivalent make as directed by engineer incharge.) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 126 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, Including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc /Siemens Marq/schneider Zencelo/Crabtree athena make.) |
| 127 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, Including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 128 | Supplying & fixing suitable size Gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP M.C.B, \\"C\\" curve including connections painting etc as required |
| 129 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor (Polycab green/ Fenolex/ Havell lifeguard/ Salzer/ equivalent as directed by engineer incharge.), single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit) medium class PVC conduit as required.(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 130 | (b)2 X 6 sq. mm +1 X 6 sq. mm earth wire |
| 131 | (c)2 x 10 sq. mm + 1 X 6 sq. mm earth wire |
| 132 | D)4 X 10 sq. mm +2 X 6 sq. mm earth wire |
| 133 | Supplying and fixing of following sizes of medium class PVC conduitt Anchor/Ravindra/Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, complete25mm |
| 134 | Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends. |
| 135 | Supply installation testing and commissioning of 12-15 W+ LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95 THD<10%, CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved in-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/Havell/Trilux/Wipro/Crompton make/sample to be approved before installation... |
| 136 | Supply installation testing and commissioning of decorative LED wall bracket Philips/TRulux/Wipro make/sample to be approved before installation.. |
| 137 | S/F testing and comm. Of 36 W + 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with minimum system lumen efficacy of 100 lm/W with THD<10%. (commercial series) CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/Havell/Trilux/Wipro/Crompton make/sample to be approved before installation.. |
| 138 | Supply Installation testing and comm. of flood light 100 W (warm, white ), Epoxy powder coated die-cast aluminlum housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07,, with high power LED's as light source with Built-in Potted IP67 electronic LED driver with APFC, lower THD, toughned glass and secondary lens, Open Circult Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Bulit in SPD & other safety test as per I5 15885 Part-Z/Sec 13, IEC60598-1. Preferred make: Philips/ Havell /Wipro/Crompton make, the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job. |
| 139 | S/F testing and comm. Of MCB's of the below mentioned capacities in sub main controls legrand C curve/Schinider/L&T /equivalent make les directed by engineer Incharge.a) 6-32 Amp SP MCB |
| 140 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 nos, blades, 30 cm long down rod, 2 nos, canoples, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per 15: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), Insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 141 | Supply and fixing of 6 amp/250 V AC fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB Tiysha/schneider Lida Havell Coral make |
| 142 | Supply installation testing and comm. Of 200mm -250mm sweep exhaust fan Shutter type of havell /USHA/Crompton/equivalent make as directed by engineer Incharge, including making of space in wall/window as per site requirement and necessary connections. |
| 143 | Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates |
| 144 | Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board, (legrand/ Shinider/Hager/ABB make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, Interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)6 way (4+24), Double door TPN |
| 145 | Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block |
| 146 | Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode, 80mm dia. connecting the plate with main control board by 10 SWG copper wire with 1/2\\" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound. |
| 147 | Supply laying, testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.c) 50 sq.mm 3.5core |
| 148 | Earth work excavation for cable trench, 2 ft deep with an average breadth of 1.5ft and refilling of trench with excavated earth after laying of cable and ramming It properly excluding cost of cable |
| 149 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 150 | Supplying, Installation, Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683) suitable for '8' and 'C\\" class fires-inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical. Ceasefire/equivalent make as desired by engineer incharge. |
| 151 | S/L testing and comm. Of three phase 15 KVA 50HZ oil cooled (Transformer oil is to be provided with stabilizer conforming to 15 335,JEC296)) unbalanced type servo voltage stabilizer(A.E/Cosca/Chinar/ Electricfield make) having an input voltage ranging from 156V to 415 VI phase to phase) and balanced output voltage of 415V, +/-1% (Test certificate to be provided by the manufacturer)a)0-500V moving iron type voltmeter with selector switch.b) A three phase change over switch to read voltage on incoming and output sidec) indicating lights 6 No two numbers for each of the motorised units, one for lower limit and other for higher limit.d) six push button control for movement operation of three motorised dimmer units two for each unit le one for raise operation and one for lower operation under the conditions of adjustment of auto/mannual selector switch (DPDMe) Single phase Preventer (contactor Switch of required rating) Legrand make.f )six potential meter resistance with lock meter two for each phase control, one for sensitivity and other for level control.g) two sets of indication lamps three numbers each to indicate output land input Indicationh) 20% over load bearing capacity for one hour |
| 152 | Supply installation testing and comm.of invertor battery 150 AH/12 V Exide invatubular/ eq. standard make as directed by engineer incharge. |
| 153 | Supply installation testing and commissioning of Sine Wave Inverter, Capacity SKVA, Supporting 4 no. batteries, 24 Month Warranty Safe for sensitive appliances with Sine wave out-put, Auto over-load handling capacity Installation and maintenance friendly Offers high quality and reliable power back-up solution for office and homes, MCB for pretection from Input mains, Bypass switch for supplying output directly from grid in case of Home UPS fault. Noiseless Operations with the help of low harmonic distortion, Intuitive Display to easily understand status of mains availability, battery status. etc.Comprehensive protection against short-circuit, reverse polarity. battery over-charge, deep-discharge etc.Adaptive Battery charging control system technology (ABCC) ensures faster battery charging and enhances battery life by around 70% Supports a wide battery range, Le. Flat Plate, Tubular & VRLA (SMF) praffered make Luminous/Microtek/Exide make. The job also includes the angle iron stand of suitable size to hold 4 No. Battries and the inverter. (Complete job) |
| 154 | Supply installation testing and commissioning of 1.5 Ton energy efficient, inverter type, split, hot and cold, Air Conditioning system suitable for operation on AC supply single phase 220 V. The indoor unit fitted on wall by employing suitable clamps and the outdoor unit fitted on the wall by using suitable angle iron stand fitted with nuts/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 sheathed/ pvc insulated coper cable and a battery operated wireless remote unit. the job also includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning.(Mitsubishi/Toshiba/Hitachi/ Panasonic/ Eq. standard make as directed by the engineer incharge. ) |
| 155 | Supply, Installation, testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton AC operating from input voltage 90-260 Volts thereby producing output voltage of 230 volts +/-3% (Vguard/Livgaurd/LG make) |
| 156 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel, floor/wall mounted, vermin and dust proof, Indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears,, Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required. (As per approved design, size may vary as per site requirement) |
| 157 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc, as required. Normal INCOMING:(a) 160 amp TPN MCCB 36 K including spreader links including spreader links, Icu=ics=100% (Adjustable thermal and Adjustable magnetic release) Legrand/Shinider/Semiens/ABB make. |
| 158 | b) 4 No. of Aluminium Bus Bar of 300 Amp. |
| 159 | c) Digital meters and phase indicators 1 - Set |
| 160 | d) Onload change over switch 100 Amp for generator Front operated |
| 161 | e) 4 No. of aluminium Bus bas of 200 AMP |
| 162 | c) Digital meters and phase indicators 1 - Set |
| 163 | Invertor Incommer(a) 100 amp DP MCCB 16 K including spreader links including spreader links, Icu=ics=100% (Adjustable thermal and Adjustable magnetic release) Legrand/Shinider/Semiens/ABB make. |
| 164 | b) 200 Amp 2 Strip Bus bar |
| 165 | c) Digital meters and phase indicators 1 - Set |
| 166 | Outgoing c) 40-63 amp DP MCB |
| 167 | c) Space for 16 way MCB's Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayJul 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender