Tender For Repair/Renewal & Certain Maintenance Of Gi Water Pipe Line At Age B/R-Ii And Age P Area Under Ge Gwalior.
Tender Value
48 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
20 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gwalior → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Renewal & Certain Maintenance Of Gi Water Pipe Line At Age B/R-Ii And Age P Area Under Ge Gwalior.
BOQ
| Sl. No. | Item Description |
| 1 | Supply & Laying as in renewal in trenches galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site of size 100 mm dia complete alongwith fittings from existing connections complete all as specified and directed. Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing and testing of the pipe. |
| 2 | All as per item No.1 above but of size 80mm dia. |
| 3 | All as per item No. 1 above but of size 50mm dia. |
| 4 | All as per item No. 1 above but of size 40 mm dia. |
| 5 | All as per item No. 1 above but of size 25 mm dia. |
| 6 | Supply & Fixing 25mm dia galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. Note:- (i) The rates quoted inclusive of cutting, jointing and testing of the pipe. |
| 7 | All as per item No. 6 above but of size 20 mm dia. |
| 8 | Excavation in trenches not exceeding 1.5M width and not exceeding 1.5M depth and getting out for laying of pipe etc in soft/loose soil complete all as specified and directed. |
| 9 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer in soft/loose soil complete all as specified and directed. |
| 10 | Removing excavated surplus in soft/loose soil to a distance not exceeding 50M and depositing where directed and at a level not exceeding 1.5M above the starting point complete all as specified and directed. |
| 11 | Material & Labour for PCC 1: 3: 6 type C1 (using 20mm graded crushed trap stone aggregate) & grouting in cement mortar 1:4 for making good road cutting complete all as specified and directed. |
| 12 | S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes complete gate valve fixed at any location of Size 50 mm dia complete all as specified and directed. |
| 13 | All as per item No. 12 above but of size 40 mm dia. |
| 14 | All as per item No. 12 above but of size 25 mm dia. |
| 15 | All as per item No. 12 above but of size 20 mm dia. |
| 16 | Material & Labour in renewal for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 200 mm and connected with necessary bolts, nuts & washers, gaskets etc complete all as specified and directed. |
| 17 | Material & Labour in renewal for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 150 mm and connected with necessary bolts, nuts & washers, gaskets etc complete all as specified and directed. |
| 18 | Supply & Fix in renewal for CI Foot Valve ISI marked with Half round Double GM flap of size 200 mm and connected with necessary bolts, nuts & washers, gaskets etc complete all as specified and directed. |
| 19 | Supply and fix in renewal 300mm dia cast iron sluice valve PN-1.6 conforming to IS 14846/2000, ISI Mark with MS spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts fixed at any location of size complete all as specified and directed. |
| 20 | All as per item No. 19 above but of size 250 mm dia. |
| 21 | All as per item No. 19 above but of size 200 mm dia. |
| 22 | All as per item No. 19 above but of size 150 mm dia. |
| 23 | All as per item No. 19 above but of size 100 mm dia. |
| 24 | All as per item No. 19 above but of size 80 mm dia. |
| 25 | M&L for Construction of valve chambers of size 1.5x1.5 x1.2 internal dimentions with 150 mm thick PCC foundation 1:4:8 type D2 (using 40 mm graded trap stone aggregate) 230 mm thick brick masonary wall with sub class 'B' bricks builts in cement mortar 1:4, 10 mm thick plastering to brick masonary in cement mortar internally and externally upto 15 cm below ground level in CM 1:4, 50 mm thick coping with PCC 1:2:4 type B1 (using 20 mm graded crushed trap stone aggregate) valve chamber having coller frame size 1.5x1.5 x1.2 made of mild steel angles of size 50mm x 50mm x 6mm and cover made of 2.5 mm thick mild steel sheet framed by 40x40x5 mm MS angle having 02 nos cross 'X' supprt fixed with coller frame by mild steel hinges - 02 Nos, locking arrangements with provision of locks and painting the steel surfaces with two coats of alluminium enameled paint over a coat of zinc chromate primer including neccessary earth work, excavation complete all as specified and directed. |
| 26 | All as per item No. 25 above but of size 1.5M x 1.5M X 1.5M (Internal Size) |
| 27 | M & L for rectification of joint leakage of CI/DI pipeline incl excavation, return filling, leadwool, lead pig, tyton Joint, 'D' Joint, MS Clamp and short piece of CI/DI pipes as required at site etc of size 300 to 400 mm dia pipe all as required and directed at site.Note:- Contractor will have to make arrangement for T&P, drain out/ pump out water. cutting of road/ path/culvert shall be make good as per original existing without any extra cost. |
| 28 | All as per item No. 27 above but of size 200 to 250 mm dia pipe. |
| 29 | All as per item No. 27 above but of size 100 to 150 mm dia pipe. |
| 30 | All as per item No. 27 above but of size 80 mm dia pipe. |
| 31 | Repair to leakage of existing GI pipe line 15 mm to 20 mm bore in any positions (joints, fittings etc) on wall ,roof, floor etc including renewal of GI fittings such as tee ,sockets elbows,unions nipples,reducers etc incl necessary excavation and earth work complete all as specified and directed. Note:- (i) GI Pipe off size and Earth work for replcement of GI Pipe shall be measured and Paid separately under relevant items of this schedule. |
| 32 | All as per item No 31 above but GI Pipe of dia 25 mm to 50 mm dia |
| 33 | All as per item No 31 above but GI Pipe of dia 80 mm to 100 mm dia |
| 34 | M & L for Taking out Sluice valve of size 300 mm dia for Refacing, Regrinding, Opening all parts at site and renewal of UNSV parts like MS Spindle, U clamp check Nut, Brass Gate, gasket seel, glands, nut, bolts, washer etc and refixing complete after repair at site complete all as specified and directed. Note :- Major parts like Spindle, Brass Gate, U Clamp Chek Nut etc measured & paid separately. |
| 35 | All as per item No. 34 above but Sluice valve of size 250 mm dia. |
| 36 | All as per item No. 34 above but Sluice valve of size 200 mm dia. |
| 37 | All as per item No. 34 above but Sluice valve of size 150 mm dia. |
| 38 | All as per item No. 34 above but Sluice valve of size 100 mm dia. |
| 39 | All as per item No. 34 above but Sluice valve of size 80 mm dia. |
| 40 | Supply only MS Spindle as per existing size and shape for repair to sluice valve of size 300mm dia complete all as specified and directed. |
| 41 | All as per item No. 40 above but of size 250mm dia. |
| 42 | All as per item No. 40 above of size 200 dia . |
| 43 | All as per item No. 40 above of size 150 dia. |
| 44 | All as per item No. 40 above of size 100 dia complete. |
| 45 | All as per item No. 40 above of size 80 dia complete . |
| 46 | Supply only CI Gate as per existing size and shape for repair to sluice valve of size 300mm dia complete all as specified and directed. |
| 47 | All as per item No. 46 above of size 250mm dia complete. |
| 48 | All as per item No. 46 above of size 200 dia complete. |
| 49 | All as per item No. 46 above of size 150mm dia complete. |
| 50 | All as per item No. 46 above of size 100mm dia complete. |
| 51 | All as per item No. 46 above of size 80 dia complete. |
| 52 | Supply only CI U clamp (Gate Clamp) as per existing size and shape for repair to sluice valve of size 250mm to 300mm dia complete all as specified and directed. |
| 53 | All as per item No. 52 above but for repair to sluice valve of size 150mm to 200mm dia complete all as specfied and directed. |
| 54 | All as per item No. 52 above but for repair to sluice valve of size 80mm to 100mm dia complete all as specfied and directed. |
| 55 | Providing JCB Loader to manage the breakdown and otherwise Excavation, shifting of pipes,and balancing work at any time in round the clock complete all as specfied and directed. Note:- Minimum hiring time not less than 3 Hrs |
| 56 | Material & Labour in renewal for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 100 mm and connected with necessary bolts, nuts & washers, gaskets etc complete all as specfied and directed. |
| 57 | Material & Labour for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 80 mm and connected with necessary bolts, nuts & washers, gaskets etc complete all as specfied and directed. |
| 58 | Boring of holes under road, pavement, hard standing by trenches technology up to size 25mm to 100mm complete all as specified and directed |
| 59 | Supply only Calcium Hypochlorite 65% to 70% chlorine content in packed with 45 Kg each drum (calcium based granular disinfectant for water treatment much more stable than chlorine gas and stronger than bleaching powder & sodium hypochlorite complete all as specified and directed. Make : Aquafit or equivalent as approved by NMPT committee of E- in-C's Branch. Note :-The contractor must submit the COC (Certificate of Compliance) in original from manufacturer by All India Authorised MES Distributor for each batch of product delivered indicating and including Chemical Analysis Report by All India Authorised MES Distributor.Note :- 1. The contractor must submit the COC (Certificate of Compliance) in original from manufacturer for each batch of product delivered including chemical analysis report. Contractor has to get delivered including chemical analysis report. Contractor has to get approval of Accepting officer before placing purchase order . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysJul 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender