Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #56326808

Tender For Repair/Renewal And Certain Maintenance Of Gi Water Pipe Line At Age B/R-I Area Under Ge Gwalior.

Issued by Statutory Bodies & Commissions/Committees · Gwalior, Madhya Pradesh
Tender Value
48 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
11 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gwalior → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Renewal And Certain Maintenance Of Gi Water Pipe Line At Age B/R-I Area Under Ge Gwalior.

BOQ

Name of Work:- REPAIR/RENEWAL AND CERTAIN MAINTENANCE OF GI WATER PIPE LINE AT AGE B/R-I AREA UNDER GE GWALIOR.
Sl. No. Item Description
1Taking out old unserviceable pipe line alongwith fittings from existing connections of size 100 mm dia complete all as specified and directed.
2All as per item No. 1 above but of size 80mm dia.
3All as per item No. 1 above but of size 50mm dia.
4All as per item No. 1 above but of size 40 mm dia.
5All as per item No. 1 above but of size 25 mm dia.
6All as per item No. 1 above but of size 20 mm dia.
7Supply & Laying in trenches galvanised steel water tubing of size 100 mm dia of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site complete all as specified and directed. Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing and testing of the pipe.
8All as per item No. 7 above but of size 80mm dia.
9All as per item No. 7 above but of size 50mm dia.
10All as per item No. 7 above but of size 40 mm dia.
11All as per item No. 7 above but of size 25 mm dia.
12Supply & Fixing 25mm dia galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc and fixed complete to walls and ceilings or laid in floors all as directed complete all as specified and directed.Note:- (i) The rates quoted inclusive of cutting, jointing and testing of the pipe.
13All as per item No. 12 above but of size 20 mm dia.
14Excavation in trenches not exceeding 1.5M width and not exceeding 1.5M depth and getting out for laying of pipe etc in soft/loose soil complete all as specified and directed.
15Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer in soft/loose soil complete all as specified and directed.
16Removing excavated surplus in soft/loose soil to a distance not exceeding 50M and depositing where directed and at a level not exceeding 1.5M above the starting point complete all as specified and directed.
17Material & Labour for PCC 1: 3: 6 type C1 (using 20mm graded crushed trap stone aggregate) for making good road cutting complete all as specified and directed.
18S&F 50 mm dia gun metal gate valves with iron wheel head screwed at both ends for iron pipes complete including dismantling of old unserviceable gate valve fixed at any location complete all as specified and directed.
19All as per item No. 18 above but of size 40 mm dia.
20All as per item No. 18 above but of size 25 mm dia.
21All as per item No. 18 above but of size 20 mm dia.
22Supply and fix 300mm dia cast iron sluice valve PN-1.6 conforming to IS 14846/2000, ISI Mark with MS spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts including dismantling of old unserviceable sluice valve fixed at any location complete all as specified and directed.
23All as per item No. 22 above but of size 250 mm dia.
24All as per item No. 22 above but of size 200 mm dia.
25All as per item No. 22 above but of size 150 mm dia.
26All as per item No. 22 above but of size 100 mm dia.
27All as per item No. 22 above but of size 80 mm dia.
28M&L for Construction of valve chambers of size 1.5mx1.5mx1.2m internal dimentions with 150 mm thick PCC foundation of PCC 1:4:8 type D2 (using 40 mm graded trap stone aggregate) 230 mm thick brick masonary wall with sub class 'B' bricks builts in cement mortar 1:4, 10 mm thick plastering to brick masonary in cement mortar 1:4 internally and externally upto 15 cm below ground level, 50 mm thick coping with PCC 1:2:4 type B1 (using 20 mm graded crushed trap stone aggregate) valve chamber having coller frame size 1.5mx1.5m x1.2m made of mild steel angles of size 50mm x 50mm x 6mm and cover made of 2.5 mm thick mild steel sheet framed by 40x40x5mm, MS angle having 02 nos cross 'X' supprt fixed with coller frame by mild steel hinges - 02 Nos, locking arrangements with provision of locks and painting the steel surfaces with two coats of alluminium enameled paint over a coat of zinc chromate primer including neccessary earth work, excavation complete all as specified and directed.
29All as per item No. 28 above but of size 1.5M x 1.5M X 1.5M (Internal Size)
30M & L for rectification of joint leakage of CI/DI pipeline incl excavation, return filling, leadwool, lead pig, tyton Joint, 'D' Joint of size 300 to 400 mm, MS Clamp and short piece of CI/DI pipes as required at site etc complete all as specified and directed.Note:- Contractor will have to make arrangement for T&P, drain out/ pump out water. cutting of road/ path/culvert shall be make good as per original existing without any extra cost.
31All as per item No. 30 above but of size 200 to 250 mm dia pipe.
32All as per item No. 30 above but of size 100 to 150 mm dia pipe.
33All as per item No. 30 above but of size 80 mm dia pipe.
34Repair to leakage of existing GI pipe line 15 mm to 20 mm bore in any positions (joints, fittings etc) on wall ,roof, floor etc including renewal of GI fittings such as tee ,sockets elbows,unions nipples,reducers etc incl necessary excavation and earth work complete all as specified and directed. Note:- (i) GI Pipe off size and Earth work for replcement of GI Pipe shall be measured and Paid separately under relevant items of this schedule.
35All as per item No 34 above but GI Pipe of dia 25 mm to 50 mm dia
36All as per item No 34 above but GI Pipe of dia 80 mm to 100 mm dia
37Supply and testing to maintain water quality CHLORINATION GRANULES. 65-70% CHLORINE CONCENTRATION PACKAGING: 45 KG. HDPE DRUM complete all as specified and directed.
38M & L for Taking out Sluice valve of size 300 mm dia for Refacing, Regrinding, Opening all parts at site and renewal of UNSV parts like MS Spindle, U clamp check Nut, Brass Gate, gasket seel, glands, nut, bolts, washer etc and refixing complete after repair at site complete all as specfied and directed. Note :- Major parts like Spindle, Brass Gate, U Clamp Chek Nut etc measured & paid separately.
39All as per item No. 38 above but Sluice valve of size 250 mm dia.
40All as per item No. 38 above but Sluice valve of size 200 mm dia.
41All as per item No. 38 above but Sluice valve of size 150 mm dia.
42All as per item No. 38 above but Sluice valve of size 100 mm dia.
43All as per item No. 38 above but Sluice valve of size 80 mm dia.
44Supply only MS Spindle as per existing size and shape for repair to sluice valve of size 250mm to 300mm dia complete all as specified and directed.
45All as per item No. 44 above but for sluice valve of size 150mm to 200mm dia complete all as specified and directed.
46All as per item No. 44 above but for sluice valve of size 80mm to 100mm dia complete all as specified and directed.
47Supply only CI Gate as per existing size and shape for repair to sluice valve of size 250mm to 300mm dia complete all as specified and directed.
48All as per item No. 47 above but for repair to sluice valve of size 150mm to 200mm dia complete all as specified and directed.
49All as per item No. 47 above but for repair to sluice valve of size 80mm to 100mm dia complete all as specified and directed.
50Supply only CI U clamp (Gate Clamp) as per existing size and shape for repair to sluice valve of size 250mm to 300mm dia complete all as specified and directed.
51All as per item No. 50 above but for repair to sluice valve of size 150mm to 200mm dia complete all as specified and directed.
52All as per item No. 50 above but for repair to sluice valve of size 80mm to 100mm dia complete all as specified and directed.
53Providing JCB Loader to manage the breakdown and otherwise Excavation, shifting of pipes,and balancing work at any time in round the clock complete all as specified and directed. Note:- Minimum hiring time not less than 3 Hrs
54Boring of holes under road, pavement, hard standing by trenches technology up to size 25mm to 100mm complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56326808
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Renewal And Certain Maintenance Of Gi Water Pipe Line At Age B/R-I Area Under Ge Gwalior.
Basic Detail
Tender No 8370/GWL/E8
Bidding Type Tender
Location
City Gwalior
State Madhya Pradesh
Key Dates
Publish Date 06 Jul 2026
Submission Date 27 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 48 Lakhs
Tender Fee 500
EMD 96000
Exemption Available
Document List
7b4a4dfc-c1a7-4458-bb00-aa84596181ec.html
8370tenderdocuments.pdf
BOQ_869811.xls
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

7b4a4dfc-c1a7-4458-bb00-aa84596181ec.html

pdf

8370tenderdocuments.pdf

xls

BOQ_869811.xls

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders