Drinking Water Supply and Sanitation Government Departments Closing in 16 days TDR #56326737

Tender For Survey, Supply, Installation Testing And Commissioning (Sitc) Of Grid Connected On Ground Or Suitable Location In The Premises Of Schemesolar Pv Power Plant Including All Associated Electrical, Civil And Mechanicalworks In Jeevangarh W/S S

Issued by Government Departments · Dehradun, Uttarakhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Jul 2026
16 days left
EMD
4.45 Lakhs
Bank guarantee accepted
Document Fee
4720
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Survey, Supply, Installation Testing And Commissioning (Sitc) Of Grid Connected On Ground Or Suitable Location In The Premises Of Schemesolar Pv Power Plant Including All Associated Electrical, Civil And Mechanicalworks In Jeevangarh W/S Scheme (Constructed Under Uwsp-Peri Urban Programme) At Bolck-Vikas Nagar Dist. Dehradun

BOQ

Name of Work:- Survey, Supply, Installation Testing And Commissioning (SITC) Of Grid Connected On Ground Or Suitable Location In The Premises Of SchemeSolar PV Power Plant Including All Associated Electrical, Civil And MechanicalWorks In Jeevangarh W/s scheme (Constructed Under UWSP-Peri Urban Programme) At Bolck-Vikas Nagar Dist. Dehradun
Sl. No. Item Description
1SITC OF ON GRID SOLAR PLANTS UNDER JEEWANGARH W/S SCHEME
2JAMANKHATA Solar Monocrystalline PV module minimum 535 Wp each
3String invertor with power exporting facility to the grid having out put shall be 415VAC, 50H3, 3 Phase degree of protection IP65 with self protective and self diagnositic features such as over voltage over current (both input and out put) over/under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage.
4Hot dipped Galvanised structure including SS nut bolts from the ground level to five to six Meter height including CC foundation complete
5DCDB box between solar panels and the invertor containing DCSPD and DC MCB with fuse set complete
6ACDB box with protective devices for overload and short circuit in between invertpr and AC side
7Copper bonded Lightening arrestor
803 Nos.Chemical earthing complete with earth wire PVC pits etc as per IE rules
9Cabling work by copper two core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor
10Miscellenious works i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable
11SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data.
1211KV bidirectional net metering complete as per UPCL guideline (connection 25 KW-75 KW) with meter box (suitable for fixing of solar meter with CT ) and all accessories
13PRITHAVIPUR Solar Monocrystalline PV module minimum 535 Wp each
14String invertor with power exporting facility to the grid having out put shall be 415VAC, 50H3, 3 Phase degree of protection IP65 with self protective and self diagnositic features such as over voltage over current (both input and out put) over/under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage.
15Hot dipped Galvanised structure including SS nut bolts from the ground level to five to six Meter height including CC foundation complete
16DCDB box between solar panels and the invertor containing DCSPD and DC MCB with fuse set complete
17ACDB box with protective devices for overload and short circuit in between invertpr and AC side
18Copper bonded Lightening arrestor
1903 Nos.Chemical earthing complete with earth wire PVC pits etc as per IE rules
20Cabling work by copper two core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor
21Miscellenious works i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable
22SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data.
2311KV bidirectional net metering complete as per UPCL guideline (connection 25 KW-75 KW) with meter box (suitable for fixing of solar meter with CT ) and all accessories
24BAHADURGARH Solar Monocrystalline PV module minimum 535 Wp each
25String invertor with power exporting facility to the grid having out put shall be 415VAC, 50H3, 3 Phase degree of protection IP65 with self protective and self diagnositic features such as over voltage over current (both input and out put) over/under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage.
26Hot dipped Galvanised structure including SS nut bolts from the ground level to five to six Meter height including CC foundation complete
27DCDB box between solar panels and the invertor containing DCSPD and DC MCB with fuse set complete
28ACDB box with protective devices for overload and short circuit in between invertpr and AC side
29Copper bonded Lightening arrestor
3003 Nos.Chemical earthing complete with earth wire PVC pits etc as per IE rules
31Cabling work by copper two core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor
32Miscellenious works i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable
33SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data.
3411KV bidirectional net metering complete as per UPCL guideline (connection 25 KW-75 KW) with meter box (suitable for fixing of solar meter with CT ) and all accessories
35BHOJAWALA Solar Monocrystalline PV module minimum 535 Wp each
36String invertor with power exporting facility to the grid having out put shall be 415VAC, 50H3, 3 Phase degree of protection IP65 with self protective and self diagnositic features such as over voltage over current (both input and out put) over/under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage.
37Hot dipped Galvanised structure including SS nut bolts from the ground level to five to six Meter height including CC foundation complete
38DCDB box between solar panels and the invertor containing DCSPD and DC MCB with fuse set complete
39ACDB box with protective devices for overload and short circuit in between invertpr and AC side
40Copper bonded Lightening arrestor
4103 Nos.Chemical earthing complete with earth wire PVC pits etc as per IE rules
42Cabling work by copper two core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor
43Miscellenious works i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable
44SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data.
4511KV bidirectional net metering complete as per UPCL guideline (connection 25 KW-75 KW) with meter box (suitable for fixing of solar meter with CT ) and all accessories
46MEHUWALA KHALSA Solar Monocrystalline PV module minimum 535 Wp each
47String invertor with power exporting facility to the grid having out put shall be 415VAC, 50H3, 3 Phase degree of protection IP65 with self protective and self diagnositic features such as over voltage over current (both input and out put) over/under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage.
48Hot dipped Galvanised structure including SS nut bolts from the ground level to five to six Meter height including CC foundation complete
49DCDB box between solar panels and the invertor containing DCSPD and DC MCB with fuse set complete
50ACDB box with protective devices for overload and short circuit in between invertpr and AC side
51Copper bonded Lightening arrestor
5203 Nos.Chemical earthing complete with earth wire PVC pits etc as per IE rules
53Cabling work by copper two core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor
54Miscellenious works i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable
55SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data.
5611KV bidirectional net metering complete as per UPCL guideline (connection 25 KW-75 KW) with meter box (suitable for fixing of solar meter with CT ) and all accessories
57MEHUWALA GOSHALA Solar Monocrystalline PV module minimum 535 Wp each
58String invertor with power exporting facility to the grid having out put shall be 415VAC, 50H3, 3 Phase degree of protection IP65 with self protective and self diagnositic features such as over voltage over current (both input and out put) over/under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage.
59Hot dipped Galvanised structure including SS nut bolts from the ground level to five to six Meter height including CC foundation complete
60DCDB box between solar panels and the invertor containing DCSPD and DC MCB with fuse set complete
61ACDB box with protective devices for overload and short circuit in between invertpr and AC side
62Copper bonded Lightening arrestor
6303 Nos.Chemical earthing complete with earth wire PVC pits etc as per IE rules
64Cabling work by copper two core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor
65Miscellenious works i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable
66SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data.
6711KV bidirectional net metering complete as per UPCL guideline (connection 25 KW-75 KW) with meter box (suitable for fixing of solar meter with CT ) and all accessories
68AMBADI Solar Monocrystalline PV module minimum 535 Wp each
69String invertor with power exporting facility to the grid having out put shall be 415VAC, 50H3, 3 Phase degree of protection IP65 with self protective and self diagnositic features such as over voltage over current (both input and out put) over/under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage.
70Hot dipped Galvanised structure including SS nut bolts from the ground level to five to six Meter height including CC foundation complete
71DCDB box between solar panels and the invertor containing DCSPD and DC MCB with fuse set complete
72ACDB box with protective devices for overload and short circuit in between invertpr and AC side
73Copper bonded Lightening arrestor
7403 Nos.Chemical earthing complete with earth wire PVC pits etc as per IE rules
75Cabling work by copper two core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor
76Miscellenious works i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable
77SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data.
7811KV bidirectional net metering complete as per UPCL guideline (connection 25 KW-75 KW) with meter box (suitable for fixing of solar meter with CT ) and all accessories
79BADAMWALASolar Monocrystalline PV module minimum 535 Wp each
80String invertor with power exporting facility to the grid having out put shall be 415VAC, 50H3, 3 Phase degree of protection IP65 with self protective and self diagnositic features such as over voltage over current (both input and out put) over/under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage.
81Hot dipped Galvanised structure including SS nut bolts from the ground level to five to six Meter height including CC foundation complete
82DCDB box between solar panels and the invertor containing DCSPD and DC MCB with fuse set complete
83ACDB box with protective devices for overload and short circuit in between invertpr and AC side
84Copper bonded Lightening arrestor
8503 Nos.Chemical earthing complete with earth wire PVC pits etc as per IE rules
86Cabling work by copper two core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor
87Miscellenious works i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable
88SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data.
8911KV bidirectional net metering complete as per UPCL guideline (connection 25 KW-75 KW) with meter box (suitable for fixing of solar meter with CT ) and all accessories
90LINE JEEVANGARH Solar Monocrystalline PV module minimum 535 Wp each
91String invertor with power exporting facility to the grid having out put shall be 415VAC, 50H3, 3 Phase degree of protection IP65 with self protective and self diagnositic features such as over voltage over current (both input and out put) over/under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage.
92Hot dipped Galvanised structure including SS nut bolts from the ground level to five to six Meter height including CC foundation complete
93DCDB box between solar panels and the invertor containing DCSPD and DC MCB with fuse set complete
94ACDB box with protective devices for overload and short circuit in between invertpr and AC side
95Copper bonded Lightening arrestor
9603 Nos.Chemical earthing complete with earth wire PVC pits etc as per IE rules
97Cabling work by copper two core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor
98Miscellenious works i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable
99SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data.
10011KV bidirectional net metering complete as per UPCL guideline (connection 25 KW-75 KW) with meter box (suitable for fixing of solar meter with CT ) and all accessories
101GOKULWALA Solar Monocrystalline PV module minimum 535 Wp each
102String invertor with power exporting facility to the grid having out put shall be 415VAC, 50H3, 3 Phase degree of protection IP65 with self protective and self diagnositic features such as over voltage over current (both input and out put) over/under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage.
103Hot dipped Galvanised structure including SS nut bolts from the ground level to five to six Meter height including CC foundation complete
104DCDB box between solar panels and the invertor containing DCSPD and DC MCB with fuse set complete
105ACDB box with protective devices for overload and short circuit in between invertpr and AC side
106Copper bonded Lightening arrestor
10703 Nos.Chemical earthing complete with earth wire PVC pits etc as per IE rules
108Cabling work by copper two core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor
109Miscellenious works i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable
110SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data.
11111KV bidirectional net metering complete as per UPCL guideline (connection 25 KW-75 KW) with meter box (suitable for fixing of solar meter with CT ) and all accessories Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56326737
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 23-07-2026
Authority
Authority Name Drinking Water And Sanitation Department
Work Description Tender for Survey, Supply, Installation Testing And Commissioning (Sitc) Of Grid Connected On Ground Or Suitable Location In The Premises Of Schemesolar Pv Power Plant Including All Associated Electrical, Civil And Mechanicalworks In Jeevangarh W/S Scheme (Constructed Under Uwsp-Peri Urban Programme) At Bolck-Vikas Nagar Dist. Dehradun
Basic Detail
Tender No 439/E-Tender Notice 2026-27 Dt 04.07.2026
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 06 Jul 2026
Submission Date 23 Jul 2026
Open Date 24 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 4720
EMD 4.45 Lakhs
Exemption Not Available
Document List
32ed1ac1-129c-4a05-81b1-9a4a2a068cd8.html
BOQ_114884.xls
ETD.pdf
Tendernotice_1 (12).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Jul 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

32ed1ac1-129c-4a05-81b1-9a4a2a068cd8.html

xls

BOQ_114884.xls

pdf

ETD.pdf

pdf

Tendernotice_1 (12).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders