Tender For Infrastructure Development At Chausathi Yogini Temple At Hirapur In Khordha Dist.
Tender Value
11.39 Crore
Estimated cost
Bid Submission
20 Jul 2026
11 days left
EMD
11.39 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Infrastructure Development At Chausathi Yogini Temple At Hirapur In Khordha Dist.
BOQ
| Sl. No. | Item Description |
| 1 | Single under reamed pile foundation of 6.0mtr long with RCC M25 using 12mm size black hard granite crusher broken chips of approved quality from approved quarry including .including cost of borringmixing and compacting to proper shape and size, smooth, scaffolding, watering and curing for the required period including cost of all materials with taxes, royalties transportation, loading and unloading, all labour, sundries, T&P including hire & running charges of concrete mixer and vibrator for the work etc but excluding cost of M.S./Tor steel and labour charges for cutting, bending and binding of steel. completed as per direction of the Engineer-in-charge. 375 mm dia and 6.0M long |
| 2 | Boundary wall |
| 3 | Interpretation center |
| 4 | For each additional depth of 0.5m beyond initial depth of 6.0m. (375 mm dia 7.0M long |
| 5 | Interpretation center |
| 6 | Earth work in ordinary soil with initial lead and lift including rough dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with all leads and lifts, T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, designing including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge.upto 1.5mtrs |
| 7 | Boundary wall |
| 8 | Interpretation center |
| 9 | Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.5metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
| 10 | Boundary wall |
| 11 | Parking |
| 12 | Pathway near Interpretation Centre. |
| 13 | Interpretation center |
| 14 | Seating Benches & Dustbin. |
| 15 | Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc.complete as directed by the Engineer-In-charge. (Used for site Development) |
| 16 | Boundary wall |
| 17 | Parking |
| 18 | Interpretation center |
| 19 | Seating Benches & Dustbin. |
| 20 | Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
| 21 | Pathway near Interpretation Centre. |
| 22 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,labour cess, sundries, T&P required for the work etc.complete in all respect as per direction by the Engineer in charge. (Measurement will be taken on finished compacted section only). |
| 23 | Boundary wall |
| 24 | Parking |
| 25 | Pathway near Interpretation Centre. |
| 26 | Interpretation center |
| 27 | Seating Benches & Dustbin. |
| 28 | Construction of granular sub-base by providing close graded granular sub base Grading-ivmaterial as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, & compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT & H Specifications for Road & Bridge works (4th Revision) A.R.Page-160 & Item no.39 as per direction of the Engineer-in-charge. |
| 29 | Parking |
| 30 | Providing & laying spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in sub base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works. (4th Revision) A.R.Page-166 & Item no.42 as per direction of the Engineer-in-charge. |
| 31 | Parking |
| 32 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge. |
| 33 | Boundary wall |
| 34 | Parking |
| 35 | Pathway near Interpretation Centre. |
| 36 | Dola Mandap |
| 37 | Dola Pindi |
| 38 | Interpretation center |
| 39 | Seating Benches & Dustbin. |
| 40 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 41 | Interpretation center |
| 42 | Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade as per direction of the Engineer-in-charge. Both face dressed : White sand stone Jodhpur. (CPWD-2023/7.12.2.2) |
| 43 | Interpretation center |
| 44 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position as per direction of the Engineer-in-charge. |
| 45 | a) Pile Cap |
| 46 | Boundary wall |
| 47 | Interpretation center |
| 48 | b) Columns. |
| 49 | Boundary wall |
| 50 | Interpretation center |
| 51 | c) GB/PB Beams |
| 52 | Boundary wall |
| 53 | Interpretation center |
| 54 | d) Lintel beam . |
| 55 | Interpretation center |
| 56 | e) Chajja. |
| 57 | Interpretation center |
| 58 | f) Roof Beams. |
| 59 | Interpretation center |
| 60 | g) RCC Slab . |
| 61 | Interpretation center |
| 62 | h) Staircase |
| 63 | Interpretation center |
| 64 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. |
| 65 | Boundary wall |
| 66 | Interpretation center |
| 67 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 68 | Interpretation center |
| 69 | Dola Mandap |
| 70 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 71 | Interpretation center |
| 72 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 73 | Interpretation center |
| 74 | Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 1200mm Color / Printed series (Homogenous) of approved make (JOHNSON /OASIS / SOMANY/ KAJARIA/ RAK) in floors on 20mm thick bed of C.M. (1:4)(1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge. |
| 75 | Interpretation center |
| 76 | Providing and laying Vitrified skirting tiles 600x1200 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, SOMANY, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 12mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. |
| 77 | Interpretation center |
| 78 | Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by Engineer-In-Charge) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 79 | Interpretation center |
| 80 | Providing and fixing 20mm thick Granite stone Skirting (sample of Granite stone should be approved by Engineer-In-Charge) for stair case trade, riser, Toilet wall/dado and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 81 | Interpretation center |
| 82 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-Charge) |
| 83 | Interpretation center |
| 84 | Painting two coats with approved antifungal weather seal paints (ISI) of approved colour, shade on wall surface including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour,labour cess with T&P etc, complete as per specification & direction of Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-Charge) |
| 85 | Interpretation center |
| 86 | Finishing plastered wall surface with acrylic wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. |
| 87 | Interpretation center |
| 88 | Painting two coats with plastic emulsion paint \\"Royal Shyne\\" to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-Charge) |
| 89 | Interpretation center |
| 90 | Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete. as per direction of Engineer-in-Charge. |
| 91 | Interpretation center |
| 92 | Providing and fixing of factory made ((Make-FENESTA/ Koemmerling/ DURAPLAST/ Rajshri). or equivalent )of colour UPVC sliding window or openable (approved colour of Frame ) complete with U value=1.9-1.3 W/m 2k/3k, flame resistance, self extinguishing, lead free comprising colour UPVC multi chambered frame having in built UPVC roller track on top and UPVC sash with wall thickness of 2.3mm duly reinforced with G.I section 2.6 mm where ever required. All corners of frame and sash will be fusion welded. After placing12.5mm laminate glass (6mm clear toughtened +1.5 pvg laminate+5mm clear glass) Annealed glass in the sash, with suppord of hurricane bar for high wind support. uPVC glazing bead, interlock, EPDM gasket brush shall be provided including multi lock and rollers & proper drainage system shall be provided. window frame will be fixed to the wall with 100mm long and 8mm dia.Fasteners and after fixing the gap between frame and adjucent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per approved drawing & direction of the Engineer -In-Charge. |
| 93 | Interpretation center |
| 94 | Supply and fixing of uPVC Ventilator glazed Louvers made out of hollow multi-chambered uPVC sections having isolated drainage system with the design Movable Louvers with Exhaust Provision. The frame of the window having over all size of 45 x 45 mm having internal wall thickness of 2.25 mm. The glass holding made out of Aluminum square sections with white powder coating with over all size of 45 x 25 with internal wall thickness 2.25 mm. Reinforcement of galvonised mild steel with thickness of 1.20 mm has put throughout the frame. Glass will be frosted 5 mm. .The rates shall be inclusive of all cost of materials,labour,T&P etc. complete. Rates are inclussive of all cost of materials, labour, conveyance, loading & unloading, taxes and T&P etc. complete as per the direction of EIC. ((Make-FENESTA/ Koemmerling/ DURAPLAST/ Rajshri) |
| 95 | Interpretation center |
| 96 | Providing and fixing M.S grill of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification as per direction of the Engineer-in-charge. . (All steel sections contractor's own supply). |
| 97 | Boundary wall |
| 98 | Interpretation center |
| 99 | Boundary wall |
| 100 | Parking |
| 101 | Interpretation center |
| 102 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL or equivalent ) |
| 103 | Interpretation center |
| 104 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 105 | Interpretation center |
| 106 | Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect confirming to IS 5758:1984 as per direction of Engineer-in-charge. |
| 107 | Parking |
| 108 | Providing and fixing 50 mm thick Khandolite stone flooring (sample of Sand stone should be approved by Engineer-In- Charge) for Floor area and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 109 | Pathway near Interpretation Centre. |
| 110 | Dola Mandap |
| 111 | Dola Pindi |
| 112 | Providing and fixing neatly carved and finished Best quality Khandolite Stone/Jodhpur Sand stone sculptures/ Murals/ Decorative pieces of required shape & sizes, in all heights & floors & Locations, for foundation/ Superstructure/ Clading/ Flooring/ Skirting etc. works as given below, inlcuding all necessary materials like Stone, M.S. clamps, dowels, Chemicals for fixing, Grout materials, cement mortar etc all complete with propoer grouting, rubbing, grinding and finishing as per approved drawings, specifications and directions of the Engineer-In-Charge/Architect (The Agency should take approval of the stone and the final sketch of the work to be executed in accordance with the drawings and specifications provided, from the concerned Architect & Engineer-in-charge) |
| 113 | Dressed & Carved Pieces in required sizes of Minimum Thickness of 150mm with carving work up to a depth of 100mm as per direction of the Engineer-in-charge. |
| 114 | Interpretation center |
| 115 | Signages, Seating Benches & Dustbin. |
| 116 | Dressed & Carved Pieces in required sizes of Minimum Thickness of 150mm with carving work up to a depth of 75mm as per direction of the Engineer-in-charge. |
| 117 | Interpretation center |
| 118 | Dressed & Carved Pieces in required sizes of Minimum Thickness of 150mm with carving work up to a depth of 50mm as per direction of the Engineer-in-charge. |
| 119 | Interpretation center |
| 120 | Dressed & Carved Pieces in required sizes of Minimum Thickness of 150mm with carving work up to a depth of 25mm as per direction of the Engineer-in-charge. |
| 121 | Interpretation center |
| 122 | Dressed & Carved Pieces in required sizes of Minimum Thickness of 100mm with carving work up to a depth of 75mm as per direction of the Engineer-in-charge. |
| 123 | Interpretation center |
| 124 | Dressed & Carved Pieces in required sizes of Minimum Thickness of 100mm with carving work up to a depth of 50mm as per direction of the Engineer-in-charge. |
| 125 | Interpretation center |
| 126 | Dressed & Carved Pieces in required sizes of Minimum Thickness of 100mm with carving work up to a depth of 25mm as per direction of the Engineer-in-charge. |
| 127 | Interpretation center |
| 128 | Dressed & Carved Pieces in required sizes of Minimum Thickness of 75mm with carving work up to a depth of 50mm as per direction of the Engineer-in-charge. |
| 129 | Interpretation center |
| 130 | Pathway near Interpretation Centre. |
| 131 | Dressed & Carved Pieces in required sizes of Minimum Thickness of 75mm with carving work up to a depth of 25mm as per direction of the Engineer-in-charge. |
| 132 | Interpretation center |
| 133 | Dola Mandap |
| 134 | Dola Pindi |
| 135 | Carving over Khandolite Stone/Jodhpur Sand Stone (Up to 200 carving) : Excluding cost of Material as per direction of the Engineer-in-charge. |
| 136 | Interpretation center |
| 137 | Carving over Khandolite Stone/Jodhpur Sand Stone (Up to 250 carving) : Excluding cost of Material as per direction of the Engineer-in-charge. |
| 138 | Interpretation center |
| 139 | Carving over Khandolite Stone/Jodhpur Sand Stone (Up to 300 carving) : Excluding cost of Material as per direction of the Engineer-in-charge. |
| 140 | Interpretation center |
| 141 | Providing and fixing 150mm thick Khandolite Stone/Sand stone Skirting & Cladding (sample of Sand stone should be approved by Engineer-In-Charge) for wall surface and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc.with Chemical Adhesive(H40 Gel Kerakoll or equivalent) and jointing with coloured Chemical Grout (Fugabella-2- 12/0-5 kerakoll or equivalent ) including pointing (if required) pigment of matching shade, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 142 | Interpretation center |
| 143 | Providing and fixing 100mm thick Khandolite Stone/Sand stone Skirting & Cladding (sample ofSand stone should be approved by Engineer-In-Charge) for wall surface and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc.with Chemical Adhesive(H40 Gel Kerakoll or equivalent) and jointing with coloured Chemical Grout (Fugabella-2- 12/0-5 kerakoll or equivalent ) including pointing (if required) pigment of matching shade, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 144 | Interpretation center |
| 145 | Providing and fixing 75mm thick Khandolite Stone/Sand stone Skirting & Cladding (sample ofSand stone should be approved by Engineer-In-Charge) for wall surface and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc.with Chemical Adhesive(H40 Gel Kerakoll or equivalent) and jointing with coloured Chemical Grout (Fugabella-2- 12/0-5 kerakoll or equivalent ) including pointing (if required) pigment of matching shade, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 146 | Interpretation center |
| 147 | Providing and fixing 50mm thick Khandolite Stone/Sand stone Skirting & Cladding (sample ofSand stone should be approved by Engineer-In-Charge) for wall surface and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc.with Chemical Adhesive(H40 Gel Kerakoll or equivalent) and jointing with coloured Chemical Grout (Fugabella-2- 12/0-5 kerakoll or equivalent ) including pointing (if required) pigment of matching shade, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 148 | Interpretation center |
| 149 | Dola Mandap |
| 150 | Providing and fixing 25mm thick Khandolite Stone/Sand stone Skirting & Cladding (sample of Sand stone should be approved by Engineer-In-Charge) for wall surface and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc.with Chemical Adhesive(H40 Gel Kerakoll or equivalent) and jointing with coloured Chemical Grout (Fugabella-2- 12/0-5 kerakoll or equivalent ) including pointing (if required) pigment of matching shade, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 151 | Interpretation center |
| 152 | Dola Mandap |
| 153 | Dola Pindi |
| 154 | Moulding work over Dressed Khandolite Stone/Sand stone Plane Pieces in required sizes of Minimum thickness of 25 mm with Moulding but Excluding cost of stone as per direction of the Engineer-in-charge. |
| 155 | Interpretation center |
| 156 | Moulding work over Dressed Khandolite Stone/Sand stone Plane Pieces in required sizes of Minimum thickness of 50 mm with Moulding but Excluding cost of stone as per direction of the Engineer-in-charge. |
| 157 | Interpretation center |
| 158 | Moulding work over Dressed Khandolite Stone/Sand stone Plane Pieces in required sizes of Minimum thickness of 75 mm with Moulding but Excluding cost of stone as per direction of the Engineer-in-charge. |
| 159 | Dola Mandap |
| 160 | Dola Pindi |
| 161 | Interpretation center |
| 162 | Moulding work over Dressed Khandolite Stone/Sand stone Plane Pieces in required sizes of Minimum thickness of 100 mm with Moulding but Excluding cost of stone as per direction of the Engineer-in-charge. |
| 163 | Interpretation center |
| 164 | Moulding work over Dressed Khandolite Stone/Sand stone Plane Pieces in required sizes of Minimum thickness of 150 mm with Moulding but Excluding cost of stone as per direction of the Engineer-in-charge. |
| 165 | Interpretation center |
| 166 | Khandolite stone/Sand stone Decorative Light post Head min size (1'-0\\" x 1'-0\\" x 1'-6\\") ft as per direction of the Engineer-in-charge. |
| 167 | Pathway near Interpretation Centre. |
| 168 | Providing and fixing Ultra pavit parking Tiles 300x300 mm in Parking Floor and Skirting (thickness to be specified by the manufacturer) for any similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture edge etc. laid over 25mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with epoxy touch ups including rubbing, curing, etc. complete as per direction of Engineer-In-Charge. |
| 169 | Interpretation center |
| 170 | Providing, fixing, fitting of fully glazed door made out of Black powder coated aluminium frame using door section of 19501 of Jindal/Tata or equivalent make with top, bottom and vertical member, Glazing clip no19352 and jointing angles and 10mm thk toughened clear glass with itching as per drawing/design with all necessary hardware including long S.S handle to both side, including all cost of labour, T&P, hire charges of drilling mechine, labour charges etc. complete as per direction of Engineer-In-Charge. (all hardware fittings, size & make brand approved by EIC) |
| 171 | Interpretation center |
| 172 | Providing and fixing 20mm thick Exterior Decorative flooring (Use of Stone - Granite, Marble & Sand Stone of Decorative Flooring design should be approved by Engineer-In-Charge) for Floor and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge at all floors and all heights. |
| 173 | Interpretation center |
| 174 | Providing and laying Laterite Stone (1st quality small eye, Rusty red colour of size-15''x10''x7'' masonary in cement mortar 1:6 (1 Cement : 6 Sand) in any shape and thickness at all depths above plinth level including the cost of materials, labour, scaffolding/staging, dressing and wetting of stones, providing recesses, openings, sealing the gap between masonry and soffit of beam/ slab, embedding the fittings and fixtures, raking out the joints, curing etc. all complete as specified.as per direction of the Engineer-in-charge. |
| 175 | Boundary wall |
| 176 | Parking |
| 177 | Pathway near Interpretation Centre. |
| 178 | Moulding work over Dressed Laterite stone Plane Pieces in required sizes with Minimum thickness of 50 mm with Moulding but Excluding cost of stone as per direction of the Engineer-in-charge. |
| 179 | Boundary wall |
| 180 | Parking |
| 181 | Pathway near Interpretation Centre. |
| 182 | Moulding work over Dressed Laterite stone Plane Pieces in required sizes with Minimum thickness of 100 mm with Moulding but Excluding cost of stone as per direction of the Engineer-in-charge. |
| 183 | Boundary wall |
| 184 | Providing and laying 80 mm thick factory made cement concrete interlocking Grass-paver block of M-40 grade made by block making machine with storng vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 50mm thick sand filling.as per drawing, specification and direction of Engineer-In-charge. |
| 185 | Parking |
| 186 | Providing and fixing 40mm thick Flamed Finished Granite stone flooring (sample of Granite stone should be approved by Engineer-In-Charge) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 187 | Seating Benches & Dustbin. |
| 188 | FRP DUSTBIN:- Capacity 100 Ltr, Size-4' Height & 65\\" Dia, Material- FRP or equivalent. as per direction of the Engineer-in-charge. |
| 189 | Seating Benches & Dustbin. |
| 190 | FRP DUSTBIN:- Capacity 80 Ltr, Size-4' Height & 65\\" Dia, Material- FRP or equivalent as per direction of the Engineer-in-charge. |
| 191 | Seating Benches & Dustbin. |
| 192 | FRP DUSTBIN :- Capacity 120 Ltr, Size-4' Height, Material- FRP or equivalent as per direction of the Engineer-in-charge. |
| 193 | Seating Benches & Dustbin. |
| 194 | FRP DUSTBIN :- Capacity 120 Ltr, Size-4' Height, Material- FRP or equivalent as per direction of the Engineer-in-charge. |
| 195 | Seating Benches & Dustbin. |
| 196 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer-in-charge.(make-Supreme/Ashirvad/Oriplast/AKG or equivalent) |
| 197 | 20mm Dia CPVC Pipe |
| 198 | 25mm Dia CPVC pipe |
| 199 | 25 mm dia PVC ASTM (Sch-80) pipe |
| 200 | 32 mm dia PVC ASTM (Sch-80) pipe |
| 201 | 40mm dia PVC ASTM (Sch-80) pipe |
| 202 | 50mm dia PVC ASTM (Sch-80) pipe |
| 203 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer-in-charge.250mm Thick Wall |
| 204 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge. |
| 205 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. |
| 206 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. |
| 207 | 15mm dia long body Bib Cock cock (Jaquar)-CON-CHR-107KN. make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 208 | 15mm dia CP S.B Bib cock (CON-CHR-037KN) make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 209 | 20mm dia CP concealed stop cock(Jaquar)CON-CHR-087KN. make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 210 | 15mm dia CP angle stop cock (FLR-ACR-5053N). make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 211 | 15mm dia CP Pillar cock (Jaquar)CON-CHR-021KN. make-Jaquar/Hindware/Cdera/Parryware or equivalent. |
| 212 | 15mm dia CP Health faucet.ALD-CHR-579. make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 213 | 15mm dia Two way Bib Cock (Jaquar)-CON-CHR-041KN. make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 214 | Shower Arm (SHA-CHR-477). make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 215 | Over head shower 100mm dia round (OHS-CHR-1999). make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 216 | 32mm dia CP Bottle trap Jaquar/Cera/hindware/equivalent Make -ALD -CHR-769L -300x190cm,. make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 217 | Auto closing concealed urinal flush valve Jaquar/Cera/hindware/equivalent Make -PRS-CHR-077. make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 218 | 15mm dia CP SINK cock (Jaquar)FLR-CHR-5347N. make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 219 | Soap Dispenser with glass bottle(ACN-CHR-1135N). make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 220 | CP soap Dish holder (Jaquar make)-AKP -ABR-35731P. make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 221 | Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN). make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 222 | 600mm long CP towel rail(Jaquar)-ACN-IVY-1111NM. make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 223 | 32mm Full Thread Waste Coupl. (Jaquar) ALD-CHR-705. make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 224 | 450mm Braided hoses (Jaquar- ALD-CHR-805B). Make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 225 | Double coat hook (Cat. No. AKP-CHR-35761P of Jaquar). Make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 226 | 25mm dia brass or gun metal full way valve (make-shakti/zoloto or equivalent) |
| 227 | 32mm dia brass or gun metal full way valve (make-shakti/zoloto or equivalent) |
| 228 | 40mm dia brass or gun metal full way valve (make-shakti/zoloto or equivalent) |
| 229 | 50mm dia brass or gun metal full way valve (make-shakti/zoloto or equivalent) |
| 230 | 15mm dia CP Flange |
| 231 | 15mm dia CP Extention Nipple |
| 232 | 125mm CP grating |
| 233 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (make-Syntex or equivalent) (3 layer)on the roof of First floor |
| 234 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor (make-Supreme/Ashirvad/Oriplast/AKG or equivalent) |
| 235 | 110mm dia U-PVC SWR pipe |
| 236 | 75 mm dia UPVC SWR Pipe |
| 237 | 110mm U-PVC door tee |
| 238 | 110mm U-PVC Plain tee |
| 239 | 110mm U-PVC door bend |
| 240 | 110mm U-PVC plain bend |
| 241 | 110mm dia U-PVC 'P' trap |
| 242 | 110mm dia U-PVC Plain Shoe Bend |
| 243 | 110mm dia U-PVC offset with out ear |
| 244 | 110mm dia U-PVC cowl |
| 245 | 75 mm dia UPVC plain bend Pipe (supreme/ashirvad) |
| 246 | 76 mm dia UPVC plain Tee Pipe (supreme/ashirvad) |
| 247 | PVC clamp suitable for 75 mm to 110mm dia pipe |
| 248 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall |
| 249 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. One piece commod (Hindware)ELEMENT Cat No.92084. Make-Jaquar/ Hindware/Cera/Parryware or equivalent. |
| 250 | Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. 580mmx440mm size Orissa pan (Parryware/Hinware/Cera/Somany/Kerovit). Make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 251 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 Liters capacity PVC cistern with 32mm dia flush bend. sleek fresh single flush Starwhite, Size 47.6 X 15.5 X 32.5 cm(Hindware)21029. Make-Jaquar/Hindware/Cera/Parryware or equivalent. |
| 252 | Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm)(Hindware)No.70002. Make-Jaquar/Hindware/Cera/Parryware or equivalent as per direction of the Engineer-in-charge. |
| 253 | Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Make-Jaquar/Hindware/Cera/Parryware or equivalent.). URS-WHT-13253N Urinal (Back Inlet) |
| 254 | 15mm dia urinal spreader |
| 255 | 32mm dia C.P. dome waste |
| 256 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in chargeTable top basin JDS-WHT-25935 (Make-Jaquar/Hindware/Cera/Parryware or equivalent.) |
| 257 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge. 600mmx125mm size glass shelf with C.P gruard rail(Jaquar-ACN-CHR-1171N) (Make-Jaquar/Hindware/Cera/Parryware or equivalent.) |
| 258 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5m thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge. Design Mirror(Parryware). (Make-Jaquar/Hindware/Cera/Parryware or equivalent.) |
| 259 | Supplying all materials, labour, T&PProviding,fitting & fixing of toilet Cubicle made out of the material and specification as detailed below:(Cubicle)(1000mm(W)81550mm(D)x2003mm(H)Providing Intermediate panel,Plaster & door: The intermediate panel is one continued panel without any joints. All intermediate panel is one continued panel without any joints. All intermediate panels,pilasters and doors shall be 12mm thick with edges chamfered. The solid compact laminate(Phenolic Core board)is based on thermosetting resins,homogeneously reinforced with celluloselfibres. Top surface on both sides is melamine coated which is scratch and impact resistant.Providing Hardware and fixing: All pilasters are to be supported by adjustable foot and non corrosive inserts. Top rail and wall fixing with and exteror polyamid coating quarantees resistance to breakage,heat,humidity and chemicals. The base of the adjustable foot will be anchored to the floor with a clearance height of 100mm. Aluminum U-Channel will be used for the fixing of intermediate panels to the wall.1 unit. as per direction of the Engineer-in-charge. |
| 260 | Supplying all materials, labour, T&P and fitting & fixing of toilet front partition size 0.12x0.5 with door made 12mm thick solid compact laminated (Phenolic core board) reinforced with celluse fibres, the partision fixed in wall hanging with clamps complete etc as per specification and direction of the Engineer in charge. |
| 261 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C. |
| 262 | Supplying all materials, labour, T&P and fixing Granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge In ground floor |
| 263 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 264 | Supplying all materials, labour, T&P and providing vitrified tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany / Johnson to be pre-approved 600 x 600mm of size |
| 265 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 60cm x 30 cm size of |
| 266 | Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. |
| 267 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. |
| 268 | Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion \\"Royale Shyne\\" of Asian Paints or equivalent of approved shade as per the instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. including interior wall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge. |
| 269 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge. door frame- (3x5.40) mtr |
| 270 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter as per direction of the Engineer-in-charge. . Door Shutter (3x1.5x2.10) |
| 271 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV (Eureka Forbes)of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. |
| 272 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm |
| 273 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 274 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm |
| 275 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit |
| 276 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
| 277 | 110mm dia U-PVC Alround Concrete |
| 278 | 160mm dia U-PVC Alround Concrete |
| 279 | 100 Users R.C.C Septic Tank-1 Nos |
| 280 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 281 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. (with addl. Depth of 1.5 m) |
| 282 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department as per direction of the Engineer-in-charge. |
| 283 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 284 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 285 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 286 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 287 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 288 | For Roof slab |
| 289 | For RCC wall |
| 290 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 291 | Supplying all materials,labour,T&P and providing 12mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 292 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 293 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 294 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 295 | Dewatering with 5 H.P diesel engine pump during excavation as per direction of the Engineer-in-charge. |
| 296 | Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee |
| 297 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all completeas per direction of the Engineer-in-charge. |
| 298 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. |
| 299 | 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad) |
| 300 | 110mm U-PVC cowl |
| 301 | Sinking of 200 mm dia (8\\") Gravel Packed Production Well including saline sealing where necessary through Rotary Drilling Rig 300 Mtrs with PVC/ GI Casing Pipes as per direction of the Engineer-in-charge. |
| 302 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by Mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer-in-Charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of finished bore suitable for lowering of 200 mm dia GI/PVC pipes for housing, fitted with socket and with or without well screen as per the necessity for the soft, medium, hard and boulder formation (GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion) including lower and withdrawing of casing pipe after drilling 200 mm to 450 mm dia in over burden portion.as per direction of the Engineer-in-charge. |
| 303 | 00 mtrs. to 100 Mtrs. |
| 304 | 100 mtr. to 200 Mtrs |
| 305 | Supply of all labour & T&P for lowering the following size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and fixing all jointing materials etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fittings & jointing materials as per direction of the Engineer-in-charge. |
| 306 | 00 mtrs. to 300 Mtrs. |
| 307 | Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge. |
| 308 | Supplying all labour, tools and plant and grouting with cement bentonite slurry for saline sealing in the bore around the 200mm dia P.V.C. Casing pipe etc all complete as per the direction of the Engineer-in-Charge. (Excluding the cost of Cement.) |
| 309 | Supplying all labour,T&P and materials for packing the bore with washed gravel (size P-6) around the pipes in good quality excluding cost of gravel etc complete as per the direction of the Engineer-in-Charge. |
| 310 | Supplying all materials labour and T&P and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3 mtrs. Below ground level including cost of cement all complete as per the direction of Engineer-in-Charge |
| 311 | Cost of 200 mm dia PVC Pipe |
| 312 | Cost of cement |
| 313 | Cost of sand 75m |
| 314 | washed gravel |
| 315 | Cutting slots in casing pipe |
| 316 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. 1.50 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm as per direction of the Engineer-in-charge. |
| 317 | DOL controll pannel |
| 318 | 2.5 Sqmm flat cable |
| 319 | 32mm dia Steel short piece |
| 320 | Steel roop with cover |
| 321 | Well cap |
| 322 | 50mm size CI bracket |
| 323 | 20mm dia rigid UPVC pipe |
| 324 | 32mm Dia brass non return valve(Shakti make) |
| 325 | 32mm dia HDPE pipe |
| 326 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site.as per direction of the Engineer-in-charge. |
| 327 | Construction of 50000 Litres RCC Underground Reservoir of Inside size- 7.00 X 3.50 X2.30m as per direction of the Engineer-in-charge. |
| 328 | Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department.as per direction of the Engineer-in-charge. |
| 329 | Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department. with Ist additional depth of 1.50 m over the initial lead and lift as per direction of the Engineer-in-charge. |
| 330 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 331 | Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 332 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement and shuttering. |
| 333 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.as per direction of the Engineer-in-charge. |
| 334 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.as per direction of the Engineer-in-charge. |
| 335 | RCC floor roof, chajja etc |
| 336 | RCC Beam, Column, wall etc |
| 337 | Supplying all materials,labour,T&P and providing 12mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 338 | Supplying and fitting and fixing stainless steel 304 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge. |
| 339 | Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge |
| 340 | ELECTRICAL WORKS |
| 341 | Sub-Head I (modular Wiring Items) |
| 342 | The GFC Electrical drawing must be approved by Engineer in charge of OTDC before commencement of electrical work |
| 343 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 344 | GROUP-A |
| 345 | GROUP-B |
| 346 | GROUP-C |
| 347 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials as per direction of the Engineer-in-charge. |
| 348 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials as per direction of the Engineer-in-charge. |
| 349 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials as per direction of the Engineer-in-charge. |
| 350 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-KG/ BEC/ Precision/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT) (2X1.5+1X1.5) as per direction of the Engineer-in-charge. |
| 351 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 352 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) as per direction of the Engineer-in-charge. |
| 353 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4) as per direction of the Engineer-in-charge. |
| 354 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) as per direction of the Engineer-in-charge. |
| 355 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials as per direction of the Engineer-in-charge. |
| 356 | Supplying,fixing of 2 nos 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials as per direction of the Engineer-in-charge. |
| 357 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials as per direction of the Engineer-in-charge. |
| 358 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials as per direction of the Engineer-in-charge. |
| 359 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 360 | Supplying,laying of FRLS PVC insulated conduit of ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as per direction of Engineer -in -Charge. . FOR ELV |
| 361 | Sub-Head II (Light fitting Fixture & Fan) |
| 362 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 363 | Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow 3000 CFM @ 15mm MMWG static pressure as per direction of the Engineer-in-charge. |
| 364 | Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata) 22 gauge (0.80 mm thickness) as per direction of the Engineer-in-charge. |
| 365 | 24 gauge (0.63 mm thickness) |
| 366 | Supply, Installation, Testing and Commissioning of bird screen made by stain less steel for fans as per direction of the Engineer-in-charge. |
| 367 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 368 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/ Havells /Philips/ Wipro/ Jaquar /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 369 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro/Jaquar /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 370 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro/Jaquar /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 371 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 372 | SITC of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro/Jaquar /Crompton/Bajaj)) . The luminaire must be Replacement Warranty will be 5 years. |
| 373 | SITC of indoor rated IP20 5mtr LED Strip, operating in an ambient temperature of 0⁰C to 45⁰C. Operating at 50Hz frequency, housing of Polymide double sided PCB. LEDs used in the product shall comply with IEC 62471 for Photo-biological safety. Luminaire should have 70lm/mtr and total 350lumen in maximum 25Watt for 5mtr role. The LED shall comply with L70 life of 35000 burning hours tested at maximum current. The LEDs used should be with CCT of 3000/4000/5700 K. LED Driver shall be external type, suitable to operate in input voltage range of 140V to 300V (nominal rated voltage – 240V) with 3KV internal surge protection, Power factor of minimum 0.9, driver efficacy of minimum 85% and total harmonic distortion (THD) of less than or equal to 20% should be integral to the luminaire. (Make: Panasonic/LT/Havells /Philips/Wipro/Jaquar /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years as per direction of the Engineer-in-charge. |
| 374 | SITC of 20 watt LED focus track light with 1mtr track as per the direction of Engineer-in-charge. (Make:K-LITE Model No- 23678 Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj/Jaquar). The luminaire should be Replacement Warranty will be 2 years . |
| 375 | SITC of 12 watt LED COB light made up of die cast aluminium body & Clear polycarbonate diffuser with 100Lm/Watt, Citizen COB, IP-54, SDCM<3, CRI 90, CCT - 3000K, as per the direction of Engineer-in-charge. (Make: K-Lite Model No - 28178 / Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj/Jaquar). The luminaire should be Replacement Warranty will be 2 years . |
| 376 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 377 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years |
| 378 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required as per direction of the Engineer-in-charge. (but with out MCB/ RCCB/ Isolator).Warranty on DB is 3 years (UDB FOR IC,OFFICE,MAIN UDB) |
| 379 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door as per direction of the Engineer-in-charge. Warranty on DB is 3 years (FOR LIGHT,ComputerDB) |
| 380 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door as per direction of the Engineer-in-charge. (FOR POWER & INDOOR AC DB)Warranty on DB is 3 years |
| 381 | 2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years as per direction of the Engineer-in-charge. |
| 382 | Supplying and fixing 6- 32 amps rating, 240 volts, C series, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years . |
| 383 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years. |
| 384 | Supplying and fixing 40Amps 4P 415 volts, MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 385 | Supplying and fixing 40 Amps rating, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 386 | Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 387 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 388 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 389 | CABLING AND END TERMINATION MAIN AREA |
| 390 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 391 | 4core x 16 sq mm |
| 392 | 3.5core x 150 sq mm 2 RUNS MAIN |
| 393 | 3.5core x 95 sq mm |
| 394 | 3.5core x 50 sq mm |
| 395 | LAYING OF CABLE |
| 396 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 397 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 398 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 399 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 400 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 401 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 402 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 403 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 404 | Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 405 | Supplying and making end termination with 3.5 core x95 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 406 | Supplying and making end termination with 3.5 core x150 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 407 | Supplying and making end termination with 3.5 core x50 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 408 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 409 | 50 mm dia |
| 410 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 411 | Supplying,laying of 3cx2.5 sq.mm AL armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 412 | Supplying,laying of 3cx6 sq.mm AL. armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster ) |
| 413 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 414 | 50 mm dia |
| 415 | EARTHING |
| 416 | Supplying,installation,testing & commissioning Of Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required as per direction of Engg. in charge. |
| 417 | Supplying & laying of 6 swg GI WIRE at 0.5m below the ground as strip earth electrode including connection/termination with nut ,bolt ,spring washer etc as required(jointing shall be done by over laping and with 2 sets of brass nut ,bolt & spring washer spaced at 50mm . as required as per direction of Engg. in charge. |
| 418 | Supplying & laying of 25mm x 5 mm GI strip at 0.5m below the ground as strip earth electrode including connection/termination with nut ,bolt ,spring washer etc as required(jointing shall be done by over laping and with 2 sets of brass nut ,bolt & spring washer spaced at 50mm . as required as per direction of Engg. in charge. |
| 419 | PANELS |
| 420 | MAIN CONTROL PANEL OFP |
| 421 | S/I/T&Commissioning of LT OUTDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 1+2 SPD 65 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 50X10MM Separate Aluminium Earth bus bar should be installed.as per direction of the Engineer-in-charge. Provision of cable alley chamber is mandatory. All the feeders shall have ON/OFF/TRIP indication. |
| 422 | In commer-1-01 number of 400A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula In commer-2- 01 number of 160A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Changeover- 01 no of 160A 4P onload changeover switch ( DG 01 NO)(Make-Legrand/Siemens/Schneider/ABB) Busbar-1&2 04 numbers of 500Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 03 numbers of 125Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Out going- 8 numbers of 100-63Amps 4P MCCB.Icu=100%Ics,16Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Out going- 03 numbers of 160Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Outgoing- 4 nos. 32A 4P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Outgoing- 8 nos. 32A 2P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication(iii) All the MCCB outgoing feeders shall have digital ammeter with CT of suitable class 1 rating.(Make-Legrand/Siemens/Schneider/ABB) as per direction of the Engineer-in-charge. |
| 423 | MAIN CONTROL PANEL AT INTP. CENTER |
| 424 | S/I/T&Commissioning of LT INDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication. |
| 425 | In commer-1-01 number of 160A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula Busbar-1&2 04 numbers of 200Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 3 numbers of 6-32A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) Out going- 4 numbers of 6-32A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) Out going- 4 numbers of 63A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) Out going- 4 numbers of 6-32A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) with provission for 1 PH KWH meter 10-40A . . . Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication |
| 426 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER |
| 427 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 428 | LIGHT SYSTEM EXTERNAL |
| 429 | S/F of Street light-90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66, IK 08 roadway luminaire with high power LED as light source with acrylic cover as per direction of the Engineer-in-charge. (Make-Panasonic/LT/Havells /Philips/Wipro/Crompton/Bajaj/Jaquar) (5Years Warranty) |
| 430 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 431 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(with decorative DOUBLE arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 432 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 433 | Supply, Installation, Testing & Commissioning of of IP66 LED (50-60)w Post Top Fixture with Body made of Pressure Die Cast Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized PC Compound Lens for Good Impact Resistance. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 6kV Internal and 10kV External SPD of IP67). System Efficacy>100lpw. THD<10%.Submission of LM79,LM 80 report from State/central accredited NABL laboratory).CRI>=80, PF>.95. CCT - 5700/4000K.Impact Resistance IK07.Operating Voltage Between (140-270)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge.The price inclussive of 3 meter long aesthetically designed decorative light pole with Cast Aluminium base and cast aluminium in middle of the Pole . Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black & gold embellishment. The pole shall be suitable for fitting of 50-60W decorative Heritage Light . Dimension of light must be Ø400mm dia and 800mm height. Body size of the pole will Ø88mm dia. The Pole shall have base Plate Ø230x12mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge.(Make: K -lite Pole KP-12011-300 + KL-5444 Luminaries / LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj/Jaquar). as per direction of the Engineer-in-charge. |
| 434 | Supply, Installation, Testing & Commissioning of of IP66 LED (50-60)w Post Top Fixture with Body made of Pressure Die Cast Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized PC Compound Lens for Good Impact Resistance. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 6kV Internal and 10kV External SPD of IP67). System Efficacy>100lpw. THD<10%.Submission of LM79,LM 80 report from State/central accredited NABL laboratory).CRI>=80, PF>.95. CCT - 5700/4000K.Impact Resistance IK07.Operating Voltage Between (140-270)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved. Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge.Make-Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj/K-Lite.The price inclussive of of 4 meter long aesthetically designed decorative light pole with Cast Aluminium base and cast aluminium in middle of the Pole . Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black & gold embellishment. The pole shall be suitable for fitting of 50-60W decorative Heritage Light . Dimension of light must be Ø400mm dia and 800mm height. Body size of the pole will Ø88mm dia. The Pole shall have base Plate Ø230x12mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge.(Make: K -lite Pole KP-12011-400 + KL-5444 Luminaries/LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj/jaquar) as per direction of the Engineer-in-charge. |
| 435 | Supplying, Erection, Fixing, connection & testing of 50W LED Heritage post top Light to be fitted inside Khandolite architechtural bollard, Dimension of light must be Ø400mm dia and 800mm height, IP 66, IK07, amb. temp -10 to 45 degree celcious, CT 3000-5700K,,50000 HRS, CRI 70, 120 Lm/W system efficacy,driver efficiency >/ 85%,dia case aliminium housing,Clear Acrylic diffuser of Make-K-LITE /LT/panasonic/Havells /Philips/Wipro /Crompton/Bajaj/jaquar as approved maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 436 | Supply, Installation, Testing & Commissioning of of IP65 (16)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-K -lite Bollard KL-25582/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro/jaquar |
| 437 | FOCUS LIGHT |
| 438 | Supply, Installation, Testing and Commissioning of 18W LED Focus Light having CCT 3000K +/-355K as per ANSI , CRI>80, SDCM<3. The fixture housing must be Made of extruded Aluminium housingfor better thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have minimum Ingress protection of IP66. The fixture should be equiped with stabilized Injection moulded special PC diffused optics ensuring low glare. The luminaire must have Integral high efficiency electronic thermally isolated constant current IP66 driver with operating voltage range of 90-205V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of : 3kV and upgraded with integrated External IP67 protected SPD of 10KA surge protection .Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. Make: K -lite Nebula KL-22782/LT/Havells/panasonic/Philips/Wipro /Crompton/Bajaj/jaquar) as per direction of the Engineer-in-charge. |
| 439 | Supply, Installation, Testing and Commissioning of 50W LED Focus Light having CCT 3000K +/-355K as per ANSI , CRI>80, SDCM<3. The fixture housing must be Made of extruded Aluminium housingfor better thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have minimum Ingress protection of IP66. The fixture should be equiped with stabilized Injection moulded special PC diffused optics ensuring low glare. The luminaire must have Integral high efficiency electronic thermally isolated constant current IP66 driver with operating voltage range of 90-205V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of : 3kV and upgraded with integrated External IP67 protected SPD of 10KA surge protection .Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Navi KL-26805/LT/Havells/panasonic /Philips/Wipro /Crompton/Bajaj/jaquar) as per direction of the Engineer-in-charge. |
| 440 | CABLING |
| 441 | Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 442 | 4core x 16 sq mm (OFP TO IND. TIMER PANEL) |
| 443 | 4 core x 4 sq mm (for small power/LIGHT TO POLE) |
| 444 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 445 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 446 | Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 447 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Make-POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster |
| 448 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 449 | 50 mm dia |
| 450 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 451 | Solar light |
| 452 | Supply of Elegant look 60 W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=10000 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light ) as per direction of the Engineer-in-charge. Make-(Philips/Panasonic/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. |
| 453 | Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 4 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 454 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 455 | Installation of 60W AIO LED solar street light on 8 mtr octagonal pole as per direction of the Engineer-in-charge. |
| 456 | FIRE SAFETY EQUIPEMENT |
| 457 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog .4.5 kg capacity as per direction of the Engineer-in-charge. |
| 458 | Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge as per direction of the Engineer-in-charge. .Make- Safex/Supremex/ Ceasefire/Flameklog.6 kg capacity |
| 459 | SIGNAGES: SITC of flexyl Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher as per direction of the Engineer-in-charge. , MCP, fire alarm panel, in case of fire, lift, alarm valve signages |
| 460 | SITC of Illumination Glow light for Exit Indication with Battery Back-up.Make-Prolite/Bajaj as per direction of the Engineer-in-charge. |
| 461 | ELV-CCTV ,PA SYSTEM |
| 462 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell Value series/Pelco/Axis/Bosch as per direction of the Engineer-in-charge. |
| 463 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch as per direction of the Engineer-in-charge. |
| 464 | Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS) as per direction of the Engineer-in-charge. Make-Honeywell value series/ Pelco/ Axis/ Bosch |
| 465 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDD as per direction of the Engineer-in-charge. Make:- WD/Segate/Toshiba |
| 466 | SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m as per direction of the Engineer-in-charge. Makes: Honeywell, Extron, Kramer |
| 467 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty as per direction of the Engineer-in-charge. . Make: LG/Samsung/Sony |
| 468 | SITC of outdoor type double jacketed 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant as per direction of the Engineer-in-charge. . Make: Systimax, Legrand, Panduit |
| 469 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit as per direction of the Engineer-in-charge. |
| 470 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit as per direction of the Engineer-in-charge. |
| 471 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit as per direction of the Engineer-in-charge. |
| 472 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking.as per direction of the Engineer-in-charge. Make: Systimax/ Legrand/ Panduit |
| 473 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies as per direction of the Engineer-in-charge. . Make: Systimax/ Legrand/ Panduit(1 mtr length) |
| 474 | SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies as per direction of the Engineer-in-charge. Make: Systimax/ Legrand/ Panduit (2 mtr length) |
| 475 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. as per direction of the Engineer-in-charge. Make: Cisco/ Digisol/ Netgear |
| 476 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. as per direction of the Engineer-in-charge. Make: Systimax/ Legrand/ Panduit |
| 477 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. as per direction of the Engineer-in-charge. Make: Systimax/ Legrand/ Panduit |
| 478 | SITC of 9U/500D outdoor type IP 55 Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screwas per direction of the Engineer-in-charge. Make: Valrack/ Rittal/ Legrand |
| 479 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw as per direction of the Engineer-in-charge. Make:Valrack, Rittal, Legrand |
| 480 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V as per direction of the Engineer-in-charge. Make: Digisol, Cisco, HP |
| 481 | LIGHTENING PROTECTION SYSTEM--- Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 482 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 483 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance as per direction of the Engineer-in-charge. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 484 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561. as per direction of the Engineer-in-charge. (2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 485 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current as per direction of the Engineer-in-charge. Make-OBO/Dehn/ABB |
| 486 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. as per direction of the Engineer-in-charge. Make-OBO/Dehn/ABB |
| 487 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 488 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 489 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 490 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 491 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 492 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 493 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 494 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 495 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 496 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 497 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 498 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB as per direction of the Engineer-in-charge. |
| 499 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysJul 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender