Housing Urban and Rular Development Government Departments Closing in 8 days TDR #56326429

Tender For Supply Installation Testing and Commissioning of Air Conditioners In Court Room And Chambers, Of Commercial Court Jhansi And Family Court Jhansi In District Jhansi.

Issued by Government Departments · Jhansi, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Jul 2026
8 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
766
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jhansi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Air Conditioners In Court Room And Chambers, Of Commercial Court Jhansi And Family Court Jhansi In District Jhansi.

BOQ

Name of Work:- SITC of Air Conditioners in Court Room and Chambers, of Commercial Court Jhansi and Family Court Jhansi in District Jhansi.
Sl. No. Item Description
1Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & hiah voltage cutoff and 50 hz ,1 phase AC supply capable of performina coolina. dehumidification. air circulation of following capacity with Scroll rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730 hermetic compressor IS 10617. heat exchanger IS 11329 capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS: 1391 Part I1 2023. The system shall be able to operate up to 52 °C (out door ambient temperature) Inverter type - cooling Only.2.0TR with 5 Star BEE Rating. Make- Carrier/Bluestar/LG/Panasonic.
2Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & hiah voltage cutoff and 50 hz ,1 phase AC supply capable of performina coolina. dehumidification. air circulation of following capacity with Scroll rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730 hermetic compressor IS 10617. heat exchanger IS 11329 capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS: 1391 Part I1 2023. The system shall be able to operate up to 52 °C (out door ambient temperature) Inverter type - cooling Only.1.5TR with 5 Star BEE Rating. Make- Carrier/Bluestar/LG/Panasonic.
3SITC of 5 KVA Automatic Voltage Stablizer (130-280V) copper winding.
4SITC of 4 KVA Automatic Voltage Stablizer (130-280V) copper winding.
5S/F of Bracket for outdoor unit stand for split type AC.
6SITC of Suction/Discharge Copper pipe line in split A.C. unit 1.8/2.0 ton capacity including brazing, nitrile rubber insulation 9mm thick class 'O' etc complete 3/8\\" (9.50mm) and 5/8\\" (15.90 mm)
7SITC of Suction/Discharge Copper pipe line in split A.C. unit 1.5 ton capacity including brazing, nitrile rubber insulation 9mm thick class 'O' etc complete 1/4\\" (6.40 mm) and 1/2\\" (12.70mm)
8S/I of Heavy duty PVC plastic braided 20mm OD flexible pipe for condensed water drain with clipping accessoriescomplete
9Supply laying of 2.5 sqmm 4 Core round copper Cable for Indoor unit to Outdoor Unit
10Supply laying of 2.5 sqmm 3 Core round copper Cable for Stablizer unit.
11Supply , Fabrication and Installation of M.S. cage for protection of Outdoor unit from animal/theft L X W X H 1300 mm X 600 mm X 1200 mm complete in all respect
12Supply & Fixing of 63Amp TPN (Disconnector Fuse Switch) DIN Type. Make-Havells or equivalent
13Supply and Fixing of suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 25 A modular socket outlet with 25 A modular SP MCB C curve including connections painting etc. as required. (AC)
14Supply and Fixing of 4 way (4+12), Double Door, Horizontal type three pole and neutral, sheet steel, MCB Distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator).
15S/F of 63Amp Four Pole MCB (10KA), C curveMake-Havells or equivalent
16Supply and fixing of 5 to 32 amp rating 240/415V, 10KA, C curve SPMCB suitable for inductive load in existing DB complete with connections, testing and commissioning etc. as required.
17Submain wiring along with earth wire with the 2 x 6 sqmm +1 x 6 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(AC and Geyser)
18Supply and Laying of 35 Sq mm 3-1/2 Core Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
19Supply and making end termination with brass compression gland and aluminium lugs for 3.5 x 35 sqmm (32mm) size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1kv grade as required.
20Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
21Providing and fixing 25 mm X 5 mm GI strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
22Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, paintingsuspenders, fastener etc as required100 mm width X 50 mm depth X 1.6 mm thickness
23Supplying and installation following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, joined withconnectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
24Supply and fixing of fire extinguisher, ABC Type 4.00 Kg. Capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket light, along with supply of all materials and labour for proper completion of work.
25Supply and fixing of fire extinguisher, CO2 Type 4.5 Kg. Capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket light, along with supply of all materials and labour for proper completion of work. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56326429
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 20-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Supply Installation Testing and Commissioning of Air Conditioners In Court Room And Chambers, Of Commercial Court Jhansi And Family Court Jhansi In District Jhansi.
Basic Detail
Tender No 1101C/05C-EMC/26-27, Dated-23-06-2026
Bidding Type Tender
Location
City Jhansi
State Uttar Pradesh
Key Dates
Publish Date 06 Jul 2026
Submission Date 20 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 766
EMD 1 Lakhs
Exemption Not Available
Document List
8a820334-a3a9-429c-bc0d-976138ff89fd.html
BOQ_2187859.xls
Tendernotice_1.pdf
Tendernotice_2 (3).pdf
Tendernotice_3 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

8a820334-a3a9-429c-bc0d-976138ff89fd.html

xls

BOQ_2187859.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (3).pdf

pdf

Tendernotice_3 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders