Tender for Supply Installation Testing and Commissioning of Air Conditioners In Court Room And Chambers, Of Commercial Court Jhansi And Family Court Jhansi In District Jhansi.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & hiah voltage cutoff and 50 hz ,1 phase AC supply capable of performina coolina. dehumidification. air circulation of following capacity with Scroll rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730 hermetic compressor IS 10617. heat exchanger IS 11329 capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS: 1391 Part I1 2023. The system shall be able to operate up to 52 °C (out door ambient temperature) Inverter type - cooling Only.2.0TR with 5 Star BEE Rating. Make- Carrier/Bluestar/LG/Panasonic. |
| 2 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & hiah voltage cutoff and 50 hz ,1 phase AC supply capable of performina coolina. dehumidification. air circulation of following capacity with Scroll rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730 hermetic compressor IS 10617. heat exchanger IS 11329 capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS: 1391 Part I1 2023. The system shall be able to operate up to 52 °C (out door ambient temperature) Inverter type - cooling Only.1.5TR with 5 Star BEE Rating. Make- Carrier/Bluestar/LG/Panasonic. |
| 3 | SITC of 5 KVA Automatic Voltage Stablizer (130-280V) copper winding. |
| 4 | SITC of 4 KVA Automatic Voltage Stablizer (130-280V) copper winding. |
| 5 | S/F of Bracket for outdoor unit stand for split type AC. |
| 6 | SITC of Suction/Discharge Copper pipe line in split A.C. unit 1.8/2.0 ton capacity including brazing, nitrile rubber insulation 9mm thick class 'O' etc complete 3/8\\" (9.50mm) and 5/8\\" (15.90 mm) |
| 7 | SITC of Suction/Discharge Copper pipe line in split A.C. unit 1.5 ton capacity including brazing, nitrile rubber insulation 9mm thick class 'O' etc complete 1/4\\" (6.40 mm) and 1/2\\" (12.70mm) |
| 8 | S/I of Heavy duty PVC plastic braided 20mm OD flexible pipe for condensed water drain with clipping accessoriescomplete |
| 9 | Supply laying of 2.5 sqmm 4 Core round copper Cable for Indoor unit to Outdoor Unit |
| 10 | Supply laying of 2.5 sqmm 3 Core round copper Cable for Stablizer unit. |
| 11 | Supply , Fabrication and Installation of M.S. cage for protection of Outdoor unit from animal/theft L X W X H 1300 mm X 600 mm X 1200 mm complete in all respect |
| 12 | Supply & Fixing of 63Amp TPN (Disconnector Fuse Switch) DIN Type. Make-Havells or equivalent |
| 13 | Supply and Fixing of suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 25 A modular socket outlet with 25 A modular SP MCB C curve including connections painting etc. as required. (AC) |
| 14 | Supply and Fixing of 4 way (4+12), Double Door, Horizontal type three pole and neutral, sheet steel, MCB Distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator). |
| 15 | S/F of 63Amp Four Pole MCB (10KA), C curveMake-Havells or equivalent |
| 16 | Supply and fixing of 5 to 32 amp rating 240/415V, 10KA, C curve SPMCB suitable for inductive load in existing DB complete with connections, testing and commissioning etc. as required. |
| 17 | Submain wiring along with earth wire with the 2 x 6 sqmm +1 x 6 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(AC and Geyser) |
| 18 | Supply and Laying of 35 Sq mm 3-1/2 Core Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 19 | Supply and making end termination with brass compression gland and aluminium lugs for 3.5 x 35 sqmm (32mm) size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1kv grade as required. |
| 20 | Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 21 | Providing and fixing 25 mm X 5 mm GI strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 22 | Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, paintingsuspenders, fastener etc as required100 mm width X 50 mm depth X 1.6 mm thickness |
| 23 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, joined withconnectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 24 | Supply and fixing of fire extinguisher, ABC Type 4.00 Kg. Capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket light, along with supply of all materials and labour for proper completion of work. |
| 25 | Supply and fixing of fire extinguisher, CO2 Type 4.5 Kg. Capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket light, along with supply of all materials and labour for proper completion of work. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST