Tender for R&M Work Of Sub-Division (O&M) Salumber Building & Various 33 Kv S/S Buildings Under Salumber

BOQ

Name of Work:- R&M work of Sub-division (O&M) Salumber Building & Various 33 KV S/S Buildings Under Salumber
Sl. No. Item Description
1Building Items (Part A)
2Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster incl. disposal of rubbish to the dumping ground within 50mtr lead
3Renewing glass panes, with putty and nails wherever necessary : Float glass panes of thickness 4 mm
4Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance.
5Half Brick work with mechanised autoclaved flyash limebricks conforming to IS: 12894 :2002 of class designation 100in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand)
6Providing and laying in position specified grade of cementconcrete for RCC structural elements upto floor five level including curing, ompaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
7Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: 20 mm thick.
8Centering & shuttering with plywood or steel sheets includingstrutting, propping bracing both ways with steel props andremoval of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies,girders, cantilevers, bands, coping bed plates, anchor blocks,sills, chhajjas, lintel, beam, plinth beam etc.
9Providing and fixing M.S. sheet 1mm thick single leaf doorshutter in angle iron frame 35x35x5mm suitabilly diagonallybraced with 25x3mm flat iron above and below lock rail ofsize 50x5mm beading extra including all fittings, as perdirection of Engg. incharge but excluding cost of chowkhats:including two coats of anit-corrosive red oxide primer paint
10Providing and fabricating reinforcement for R.C.C. workincluding straightening, cutting, bending, placing in positionand binding (including cost of binding wire) all complete up tofloor five level.('Original producers' who manufacture billet directly fromiron ores and roll the bilets to produce steel conforming toS:1786)Hot rolled deformed bars (IS : 1139)
11Labour charges for repair to door / window without using anymaterial such as applying randha (finishing) tightening of bolts& screw etc.
12Repair of existing steel glazed doors, windows and ventilator,MS sheet door, garge doors, compound wall gates etc. bywelding drilling complete include. Cost of welding rods andhire charge of welding meachine and TP etc complete
13Providing and fixing steel glazed doors windows andventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm.long embedded in cement concrete block 15x10x10cm. of1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate20mm nominal size) or with wooden plugs and screws or rawlplugs and screws with fixing clips or with bolts and nuts asrequired including providing and fixing of plain glass panes4mm thick with cooper glazing clips and special metal sashputty of approved make or metal beading with screwscomplete including priming coat of approval steel primer,excluding the cost of metal beading and other fitting exceptnecessary hinges of pivots steel handles peg stay etc. asrequired : Windows side hung /Ventilators top or centre hung (openable) Deduct for Pin headed 4mm thick glass panels is used instead of 4mm thick plain glass
14Providing and fixing square bars or other flat welded to window, Ventilators etc
15Repair to damaged RCC slabs, beams and columns etc forstrengthening with cement mortar 1 : 2 in following steps :- Choping losse and cracked concrete to required depth,(i) cleaning the exposed surface of steel and concrete with wirebrush and sand papering , cleaning of concrete surface withwater as necessary and getting dried.(ii) Applying Epoxy primer on the exposed steel bars.(iii) Applying Epoxy hardener and resin mix (as permanufectured's specification) on concrete and steel bars with brush.(iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.(v) Plastering the surface with cement sand mortar 1 : 3 uptodepth of 30mm complete. (vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect.
16Random Rubble stone masonry with hard stone insuperstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). Wall upto 30cm. and less thickness.
17Plaster on new surface on walls in cement sand mortar 1:4including racking of joints etc. complete fine finish :20mm thick .
18Making of drip course (Tapka) in cement sand mortar 1:6width upto 40 mm and 10 mm thick as per approved design
19P & F precast cement concrete coping 1: 2:4 mix 50 mm thick complete as per sp.
20Grading roof for water proofing treatment with waterproffing compound10.17.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size)
21S & F in walls machine cut and polished stone shelves, tends and sills in CM 1:3 with machine cut edge Kota stone minimum 30mm thick.
22Making holes in stone masonry wall upto 450 mm x 450 mm size and making good in CM 1:6.
23Providing & laying broken glazed titles on roof ( brokenglazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30Kg/Sqm. Of VG-10 (80/100) grade) and joints filled withcement mortar 1 :2 (1 cement:2 marble dust mixed with waterproofing compund all complete as per direction of Engineerin-charge.
24Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-incharge.
25Demolishing stone rubble masonry manually/ by mechanicalmeans including stacking of serviceable material and disposalof unserviceable material within 50 metres lead as perdirection of Engineer-in-charge:In cement mortar.
26Structural steel work riveted, bolted or welded in built upsections, trusses and framed work, including cutting, hoisting(height upto 10 m) , fixing in position and applying a primingcoat of approved steel primer all complete:
27Painting exterior surface of Wall with 100% acrylic exteriorpaint of approved brand and manufacture to give an evenshade with two or more coats including prepartion of basewith sand papering, primer, putty, etc complete in all respectincluding scaffolding and safety provision Old Work
28Applying one coat of Cement primer of approved brand andmanufacture on wall surface including all scaffolding:
29Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade : One or more coats on old work.
30Distempering with oil bound washable distemper of approvedbrand and manufacture to give an even shade including allscaffolding
31Warer Supply & Sanitary Items (Part-B)
32P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm.
33P & F full way valve (IS 778 mark) or wheel valve of app make gunmetal 15 mm nominal bore
34P & F full way valve (IS 778 mark) or wheel valve of app make gunmetal 25 mm nominal bore
35P & F Bib Cock (IS:8931 Mark) Superior quality of approved make :Brass 400 gm. 15 mm nominal bore.
36P & F Bib Cock (IS:8931 Mark) Superior quality of approved make (-do-) Long body, 15mm nominal bore weight not less than 690 gm
37P&F Grating of approved quality/ makeStainless steel sheet size 125mm dia
38P&F rigid PVC Pipe (IS:4985 mark) class II(4 Kg. /Cm.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant75mm dia
39(B)110mm dia
40P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:(A) Plain floor trap 110 mm Dia
41(B)Bend 87.5, 110 mm
42(C)Bend 87.5, 75 mm
43(E) Door -Tee 110 mm dia
44(F) Vent Cowel 110 mm dia
45P & F 15 mm. Dia Connection pipe of approved quality/make: -do- up to length 370 mm.
46P&F stop cock (IS:8931 Mark ), superior quality & of approved make : Brass 400 gm, 15mm nominal bore.
47P & F Ball Cock (IS:1703 Mark) with Rod & P.V.C. Ball complete :Brass wt. not less than 300 gm, 15mm
48Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete asper direction of Engineer in Charge. (Internal work Exposed on wall) 15 mm nominal size
49_______DO__________ 25 mm nominal size
50Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testingof joints complete as per direction of Engineer in Charge. (External work). 15 mm nominal bore
51_______DO__________ 25 mm nominal size
52P & F WVC wash basin (Ist quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted I No 15 mm C.P. pillar cock (I.S. : 8934 Mark) & 32 mm C.P. Brass waste coupling of approved make 25 mm G.I. waste Pipe complete including cutting & making good the wall. & Floor Size 550 mm x 400 mm
53P & F flush/ flush Cock valve (IS 9758 mark) for WC to app quality / make brass/ gun metal half turn wt 1 Kg of quality/make 25 mm nominal bore
54P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipewith plug & socket, including making connection etc., complete of approved design :500 liters capacity
55Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 8mm ϕ @15 cm c/c bothways including shuttering complete in all respect.
56Electric (Part C)
57Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) virgin material UPVC trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material UPVC Modular Box , 10 A Modular switch,Modular face plate with grid plate, 3 pinceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR (a) Short point( up to 3m)
58(b) Medium point(up to 6m)
59(c) Long point (up to 10m)
60Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/ casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR (a) 2x1.5 sqmm
61(b) 2x2.5sqmm+1x1.5sqmm
62Providing & Fixing of modular type switch/ bell push duly ISI marked (IS:3854) with CM/L no. printed and made out of unbreakable and fireretardant vergin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 10 A one way switch
63Providing & Fixing of modular type lockable feature socket duly made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge, making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 6 A 3/5 pin shuttered socket
64Providing & Fixing of Recessed/surface mounting heavy dutyEnclosure made out from Galvanized steel / CRCA sheet not lessthen 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted complete with din rail making internal DBterminations with copper lugs, detachable gland plate, includingmaking connections, testing etc. as required.For additionaltechnical parameters of product / work refer Annexure 'A' attached with this BSR Suitable for Six / Eight module for MCB/ RCCB
65Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) (A) 6A to 32A rating
66Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL/ CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Double pole isolator 30/40 A rating
67Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
68Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works with Galvanized box of 1.2 mm thick with earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. . For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
69Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing
70Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR.
71Providing & Fixing of of BLDC Technology ventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutter including making connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 200 mm sweep with Min. Air delivery 800 cmh, 1600 RPM Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56325611
AUTHORITY Government Departments
TENDER VALUE 8.50 Lakhs
LAST DATE 16-07-2026
Authority
Authority Name Ajmer Vidyut Vitran Nigam Limited
Work Description Tender for R&M Work Of Sub-Division (O&M) Salumber Building & Various 33 Kv S/S Buildings Under Salumber
Basic Detail
Tender No NIT 05/26-27 UDR
Bidding Type Tender
Location
City Udaipur
State Rajasthan
Key Dates
Publish Date 06 Jul 2026
Submission Date 16 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 8.50 Lakhs
Tender Fee 590
EMD 17000
Exemption Available
Document List
BOQ_1019863.xls
c5847c4a-81d3-41e2-b010-c6bd9e878355.html
Tendernotice_1.pdf
TnCudr.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1019863.xls

html

c5847c4a-81d3-41e2-b010-c6bd9e878355.html

pdf

Tendernotice_1.pdf

pdf

TnCudr.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders