Educational and Research Institute Government Departments Closing in 6 days TDR #56325416

Tender For Comprehensive Maintenance Of Chiller Ac Plants Of Itec, Sathi And Crf Building Sonipat C Us.

Issued by Government Departments · Delhi, Delhi
Tender Value
57.79 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
6 days left
EMD
1.15 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Comprehensive Maintenance Of Chiller Ac Plants Of Itec, Sathi And Crf Building Sonipat C Us.

BOQ

Name of Work:- Comprehensive Maintenance of Chiller AC Plants of ITEC, SATHI and CRF Building Sonipat C us.
Sl. No. Item Description
1Comprehensive maintenance [including routine & preventive] and break down maintenance which includes all types of corrective actions like repairing and replacement of all defective components of high side of the Air conditioning plant comprising of all the machineries (Main chiller unit Evaporator, Condenser, Compressor, Valves, all VFDs, Electrical and Mechanical components, Electrical Components starting from switchgears installed in Electrical Distribution panel for the chiller unit, sensors, pressure and temperature gauges, insulation, leak testing and leak repairing, pressure testing, as required). The contractor shall get the high side of the chiller unit maintained by the respective OEM of chiller or by their Authorised Dealer only. (a) The contractor shall take pro-active actions so that the chiller unit remains healthy and operational during the whole contract period. Recovery @Rs.2000/- (Two thousand rupees) per day shall be made from the bill payable to the contractor for non-working the chiller unit 3 days after occurring the fault/snag. Recovery shall continue upto 30 days and after that repairing / replacement of the chiller shall be got done by the Engineer-in-charge at the risk and cost of the contractor without any notice. (b) Apart from that no payment shall be made for the period the chiller unit remains inoperative (non-functional) state. Proportionate deduction per day basis shall be made derived by dividing the contractual rate for job by 30 days.
2350 TR Water Cooled (Carrier Make, Model: 19XR313233HUDW52) [1 job means per Chiller unit per month]
3180 TR Water Cooled (Carrier Make, Model: 30XWV195) [1 job means per Chiller unit per month]
448 TR Air Cooled (Carrier Make, Model: 30RQ162) [1 job means per Chiller unit per month]
5Topping up or charging of refrigerant for water cooled chiller (R-134A or as applicable) after supplying it in cylinder in chiller unit as and when required. (a) Contractor shall always maintain ready stock of 120 kg refrigerant at site during the contract period failing which Rs.300 (Three hundred rupees) per day day shall be recovered from bill payable to the contractor till cost of the same is recovered based on contractual rate of refrigerant
6Topping up or charging of refrigerant for Air cooled chiller (R-410A or as applicable) after supplying it in cylinder in chiller unit as and when required. (a) Contractor shall always maintain ready stock of 120 kg refrigerant at site during the contract period failing which Rs.300 (Three hundred rupees) per day day shall be recovered from bill payable to the contractor till cost of the same is recovered based on contractual rate of refrigerant
7Descaling of condenser unit with circulation of diluted chemical mixed water including opening of end plates for proper cleaning, flushing the system with fresh water, refixing plates etc. complete as required. (one job means de-scaling of one unit's condenser unit)
8350 TR Water Cooled (Carrier Make, Model: 19XR313233HUDW52)
9180 TR Water Cooled (Carrier Make, Model: 30XWV195)
10Providing following items including fixing, proper testing as per direction of the Engineer-in-charge as and when required.
11SPM Electronics Card
12EXV Electronics Card
13ISM Electronics Card
14Inrush Electronics Card
15Oil Filter
16Refrigerent Filter
17Compressor scroll 16 TR Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56325416
AUTHORITY Government Departments
TENDER VALUE 57.79 Lakhs
LAST DATE 13-07-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Comprehensive Maintenance Of Chiller Ac Plants Of Itec, Sathi And Crf Building Sonipat C Us.
Basic Detail
Tender No IITD/WORKS (SP-5336)/2026
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 06 Jul 2026
Submission Date 13 Jul 2026
Open Date 14 Jul 2026
Finance
Tender Value 57.79 Lakhs
Tender Fee Ref. Documents
EMD 1.15 Lakhs
Exemption Not Available
Document List
7fa8182c-cb03-4d87-a53c-368ce58bab6f.html
BOQ_962648.xls
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

7fa8182c-cb03-4d87-a53c-368ce58bab6f.html

xls

BOQ_962648.xls

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders