Power Government Departments Closing in 24 days TDR #56324887

Tender For Construction Of 1 X 500 Mva, 400/220 Kv Sub-Station At Sawai Madhopur (Distt. - Sawai Madhopur) Alongwith 02 Nos., 220 Kv Bays At 220 Kv Gss Bhadoti Including Supply Of All Equipments/Materials, Erection (Including Civil Works), Testing An

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
125.98 Crore
Estimated cost
Bid Submission
05 Aug 2026
24 days left
EMD
2.51 Crore
Bank guarantee accepted
Document Fee
29500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of 1 X 500 Mva, 400/220 Kv Sub-Station At Sawai Madhopur (Distt. - Sawai Madhopur) Alongwith 02 Nos., 220 Kv Bays At 220 Kv Gss Bhadoti Including Supply Of All Equipments/Materials, Erection (Including Civil Works), Testing And Commissioning (On Turnkey Basis)

BOQ

Name of Work:- CONSTRUCTION OF 1 X 500 MVA, 400/220 KV SUB-STATION AT SAWAI MADHOPUR (DISTT. – SAWAI MADHOPUR) ALONGWITH 02 NOS., 220 KV BAYS AT 220 KV GSS BHADOTI INCLUDING SUPPLY OF ALL EQUIPMENTS/MATERIALS, ERECTION (INCLUDING CIVIL WORKS), TESTING AND COMMISSIONING (ON TURNKEY BASIS)
Sl. No. Item Description
1MAIN MATERIAL/ ITEMS
2500 MVA, 400/220/33 kV auto transformer
3400/220/33 kV, 500 MVA Auto Transformer with online drying system and all accessories (excluding transformer Oil) as per technical specification
4Insulating Oil for 500 MVA 400/220/33 kV Auto Transformer
5Digital RTCC Panel consisting of Digital RTCC relay as per technical Specification for transformers
6Optical Temprature Sensors alongwith measuring Units alongwith all associated accessories/ Fittings as per specification requirements for installation on all the Auto Transformers
7On-Line Dissolved Gas and Moisture Analyzer as per specification
833 kV Neutral Current Transformer
9Mandatory spares
10Oil cooler pump with motor
11Buchholz relay complete (Main Tank)
12Local & Remote WTI complete with sensing device & contacts
13Oil Temperature Indicator complete with contacts & sensing device
14Pressure relief Device
15Magnetic oil level gauge
16Cooler fan with motor
17Starters, contactors, switches & relays for electrical control panels (set consisting of one no. of each type)
18Set of valves (set consisting of complete replacement for one 3-ph auto-transformer)
19Spare Insulating Oil to be handed over to owner after commissioning
20Breather Assembly (set consisting of complete replacement for one 3-ph auto-transformer) for conservator and OLTC
21Remote tap position indicator
22Oil flow indicator with flow switch (if applicable)
23Oil surge relay for OLTC
24400 kV Bushing with metal parts and gaskets as used in the supplied 400 kV Auto transformer
25Neutral Bushing with metal parts and gaskets as used in the supplied 400 kV Auto transformer
2633/.433 kV, 800 kVA, LT three phase transformer
2733/.433 kV,800 kVA, LT three phase transformer complete with all fittings, accessories and associated equipment as per specification.
28Spares
29i) Bushing with metal parts, clamp-connectors & gaskets(HV&LV)
30ii) Winding temperature indicator with contacts
31iii) Oil temperature indicator with contacts
32iv) Pressure relief device
33v) Buchholz relay complete with contacts
34vi) Magnetic oil level gauge
35vii) Set of gaskets
3633/.433 kV, 630 kVA, LT three phase transformer
3733/.433 kV, 630 kVA, LT three phase transformer complete with all fittings, accessories and associated equipment as per specification.
38Spares
39i) Bushing with metal parts, clamp-connectors & gaskets(HV&LV)
40ii) Winding temperature indicator with contacts
41iii) Oil temperature indicator with contacts
42iv) Pressure relief device
43v) Buchholz relay complete with contacts
44vi) Magnetic oil level gauge
45vii) Set of gaskets
46Circuit Breaker
47420 kV,3150 Amp., 63 kA rupturing capacity circuit Breaker with closing resistor suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
48Terminal Connectors for above item
49420 kV, 3150 Amp.,63 kA rupturing capacity circuit Breaker without closing resistor, suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
50Terminal Connectors for above item
51Microprocessor based point of wave controller for above item [CSD]
52Spares for 400 kV circuit breaker
53(i) One pole of circuit breaker with grading capacitor complete with pole column and interrupter with M.B. but without support structure and operating mechanism.
54(ii) Rubber gaskets, ‘O’ rings and seals
55(iii) Fixed Contacts
56(iv) Moving Contacts
57(v) Terminal pads and connectors
58(vi) Closing Assembly Valve
59(vii) Trip Assembly Valve
60(viii) Auxiliary Switch Assembly
61(ix) Operation Counter
62(x) Closing Coils
63(xi) Tripping coils
64(xii) Support insulator complete for one pole of breaker
65245 kV, 2000 Amp., 50 kA rupturing capacity circuit Breaker suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
66Terminal Connectors for above item
67Spares for 245 kV circuit breaker
68(i) One pole of circuit breaker complete with pole column and interrupter with M.B. but without support structure and operating mechanism.
69(ii) Rubber gaskets, ‘O’ rings and seals
70(iii) Fixed Contacts
71(iv) Moving Contacts
72(v) Terminal pads and connectors
73(vi) Closing Assembly Valve
74(vii) Trip Assembly Valve
75(viii) Auxiliary Switch Assembly
76(ix) Operation Counter
77(xi Closing Coils
78(xi) Tripping coils
79(xii) Support insulator complete for one pole of breaker
80Current Transformer
813000-2000-1000/1 Amp., 63 kA 420 kV single phase multi core current transformers (Live Tank Type only) with 120% extended current rating
82Terminal Connectors for above item
83Spare of 420kV Current Transformer
84(i) Complete CT(Live Tank Type only)
85(ii) Terminal Connector for above item
862000-1000-500/1-1-1-1-1 Amp., 50 kA 245 kV single phase multi core current transformers (Live Tank Type only)
87Terminal Connectors for above item
88Spare of 245kV Current Transformer
89(i) Complete CT(Live Tank Type only)
90(ii) Terminal Connector for above item
91Capacitive Voltage Transformer
92420 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 400/0.11 kV and three secondary windings.
93Terminal Connectors for above item
94Spare of 420kV Capacitive Voltage Transformer
95420kV Capacitive Voltage Transformer
96Terminal Connectors for above item
97245 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 220/0.11 kV and three secondary windings.
98Terminal Connectors for above item
99Spare of 245kV Capacitive Voltage Transformer
100(i) Complete CVT
101(ii) Terminal Connector for above item
10236kV, 52kV class EMVT
103Terminal Connectors for above item
104Isolator
105420 kV 3150, 63 kA Amp. triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
106Terminal Connectors for above item
107Post insulators for above item
108420 kV 3150 Amp, 63 kA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
109Terminal Connectors for above item
110Post insulators for above item
111Spares for 420 kV Isolators
112i) One complete pole with support insulator and motor operating mechanism excluding structure
113ii) Copper contact fingers for male and female contacts.
114iii) Open / close contactor assembly, timers, key interlock push button switch
115iv) Limit switch and auxiliary switch
116v) Motor housing bearing assembly
117vi) Terminal pads and connectors
118vii) Motor with gear assembly and bevel gear assembly
119viii) Bearings
120ix) Current carrying assembly
121x) Interlocking coil
122245 kV 2000 Amp., 50KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic without earth blade complete with all accessories.
123Terminal Connectors for above item
124Post insulators for above item
125245 kV 2000 Amp.,50 KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
126Terminal Connectors for above item
127Post insulators for above item
128245 kV 2000 Amp., 50 KA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
129Terminal Connectors for above item
130Post insulators for above item
131245 kV 2000 Amp. 50 KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic for tandem operation complete with all accessories.
132Terminal Connectors for above item
133Post insulators for above item
134Spares for 245 kV Isolators
135i) One complete pole with support insulator and motor operating mechanism excluding structure
136ii) Copper contact fingers for male and female contacts.
137iii) Open / close contactor assembly, timers, key interlock push button switch
138iv) Limit switch and auxiliary switch
139v) Motor housing bearing assembly
140vi) Terminal pads and connectors
141vii) Motor with gear assembly and bevel gear assembly
142viii) Bearings
143ix) Current carrying assembly
144x) Interlocking coil
14572.5 kV , 800 Amp. , triple pole, gang operated, horizontal double break type Isolator without earth switch alongwith complete metallic and accessories.
146Terminal Connectors for above item
147Post insulators for above item
14833kV/72.5 kV D.O. Fuse Set
149Terminal Connectors for above item
150Post insulators for above item
151Surge Arresters
152Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 390 kV lightning arresters suitable for connection between phase and ground on 3 phase 420 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
153Terminal Connectors for above item
154Spare of 390kV Surge Arresters
155(i) Complete LA with insulating base
156(ii) Terminal Connector for above item
157Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 198 kV lightning arresters suitable for connection between phase and ground on 3 phase 245 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
158Terminal Connectors for above item
159Spare of 198kV Surge Arresters
160(i) Complete LA with insulating base
161(ii) Terminal Connector for above
16242 kV, 52kV class Lightning arresters
163Terminal Connectors for above
164Wave Trap
165400 kV, 1.0mH / 3150 A. Wave Traps Pedestal mounting type with tuning unit, protection device, terminals clamps, corona rings, bird barriers etc.
166220 kV, 0.5 mH / 2000 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end.
167CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
168400kV Relay Panel for line with auto reclose scheme Type-SAS-FRC
169400kV Relay Panel for 500MVA, 400/220kV Transformer Type-SAS-THRC
170400kV Relay Panel for Tie Breaker with auto reclose scheme and common relay panel Type-SAS-BTRC
171220kV Relay Panel for feeder Type-SAS-FRB
172220kV Relay Panel for 500MVA, 400/220kV Transformer Type-SAS-TLRC
173220kV Relay Panel for Transfer Bus Coupler Type-BCRB
174400kV Control Panel for line with auto reclose scheme Type-SAS-FCC
175400kV Control Panel for 500MVA, 400/220kV Transformer Type-SAS-THCC
176400kV Control Panel for Tie Breaker with auto reclose scheme and common Control panel Type-SAS-BTCC
177220kV Control Panel for feeder Type-SAS-FCB
178220kV Control Panel for 500MVA, 400/220kV Transformer Type-SAS-TLCC
179220kV Control Panel for Transfer Bus Coupler Type-SAS-BBCB
180Bus Bar Protection Scheme having one no. central unit and 16 nos. peripheral units (PU) considering all existing and future dia of 400kV Switchyard designed for one & half breaker scheme (IEC-61850 Compliant).
181Bus Bar Protection Scheme having one no. central unit and 20 nos. peripheral units (PU) considering all existing and future bays of 220kV Switchyard designed for double main and transfer bus scheme with sectionalizer (IEC-61850 Compliant).
182GPS with Digital clock
183Necessary software and hardware alongwith laptop to up / down load the data / from the relays from / to the laptop. The supply of laptop is covered under this scope.
184Mandatory Spares for C&R panels (similar items as used in the quoted panels)
185Line relay Panel:
186Main-I Type relay
187Main-II Type Relay
188LBB Relay
189Auxiliary relay, Tripping Relay, Supervision relays, timers (one of each type used in the panel)
190Under-voltage relay for isolator/earth switch
191Transformer Relay panel
192Main-I Type Differential relay
193Main-II type Differential relay
194High impedance differential (Circulating current) Relay
195Over flux relay
196Transformer overload protection relay
197Restricted Earth fault relay
198Directional back up over current & E / F relay with non directional high set feature.
199Three phase trip relays, Flag relays, auxiliary relays, timers (One of each type used in the panel)
200Tie Breaker / Bus coupler / Sectionlizer / Transfer bus coupler.
201Auto Relcose Relay
202Non directional over current & earth fault relay.
203400kV Bus bar Protection
204Peripheral unit (PU)
205220kV Bus bar Protection
206Peripheral unit (PU)
207SUBSTATION AUTOMATION SYSTEM
208Complete substation automation system alongwith necessary spares for 5 years satisfactory operation as per scope of the specification.
209Supply of Ethernet Switch, OFC, BCU, IEDs etc. to complete the scope specification .
210Phaser Measurement Unit
211Phaser Measurement Unit along with fibre optic connectivity, Global positioning system receiver and communication equipment
212PLCC EQIPMENTS
2134 Channel, Digital PLCC Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
214A.F. Protection coupler microprocessor based suitable for Four commands.
215VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
216Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
217HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
218PLCC Electronic Private Automatic Exchange (EPAX) suitable for 24 subscribers lines and 16 tie lines with redundancy of critical cards.
219Telephone Sets (Push Button Type)
22010 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.63 mm.
2215 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.63 mm.
2225 Pair jelly filled unarmoured telephone cable having copper conductor of Dia. 0.5 mm.
223Copper cables 4x6 sq mm for PLCC (2 Run)
224Sleeved copper wire of 8 SWG.
225Any other item bidder may require to complete the PLCC System asper specification's requirements.( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
226Mandatory Spares
227Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
228Cards for PLCC carrier terminal for each type
229Optical Time domain reflectometer suitable for 400KM line length
230Optical Power Meter
231Digital Level Meter cum level generator
232Set of spare cards for Digital PLCC carrier terminals
233Set of spare cards for STM-4/16 OLTE terminals
234Digital Multimeter
235FOTE TERMINAL EQUIPMENTS
236Fully wired cabinet with base 19” equipment rack (incl. front cover, cable tray, common cards) with fan unit and control, synchronization, Alarm, dual Power supply input cables
237Central Processing Card – CPU
238Power supply unit – 48 VDC 85 W
239OLTE – 4 Port STM-4/16 Card along with SFPs U4.2, U 16.2
240Optical Amplifier / Booster equipment (comprising of wave length translator, Wavelength Converter, Booster Amplifier; 21 dBm, Pre Amplifier and Raman Amplifier + Software) for main as well as protected parts
241OFC Patch Cords (Set of 48 nos.)
2428 Port 2w/4w E&M interface Card
2434 port Data Interface Card (Programmable)
2444 Port Data interface Card (Programmable) for remote end (to be located at nearest SLDC / Sub-LDC)
245Ethernet over SDH transport card (with four 10/100 base, one 100Base – FX and one 1000 Base-LX/SX front interfaces)
2464 command integrated Tele-protection Card
247MPLS TP Interface card
248Engineering Order Wire Phone
249Craft Terminal (LAPTOP PC) with element manager software
250Optical Fibre Distribution Panel (for 48 fibre) with spleing and patch parul
251Optical Fibre Distribution Panel (for 96 fibre) with spleing and patch parul
252Interface Cable for Power, Data, Voice, Tele-protection, Time Synchronizing etc. as per respective site requirement
253Approach Cable and necessary joint box for OPAW
2541G MPLS IP connectivity (ring topology) comprising IEC 104 data transmission through DCU, VOIP phone (Complitable for integration with existing CISCO make(ASR-900) MPLS)
255HDPE Duct Pipe for OPGW
256BATTERY AND BATTERY CHARGER
257220 V, 600 AH Tubular Lead Acid Battery set along with accessories, stand etc.
258220V, 100Amp/70Amp float cum boost Battery Charger (Separate sections for float and boost charging operation).
259Spare for 220 V, 600 AH Tubular Lead Acid Battery set
260i) Cells for 220 V bank
261ii) Connectors
262iii) Terminal lugs
263iv) Spanner Set
264Spare for 220 V battery charger
265i) Set of control cards for charger
266ii) Set of relays
267iii) Rectifier transformer
268iv) Control transformer
269v) Series inductor
270vi) Micro-Switches
271vii) Filter Capacitor
272viii) Thyristor diode
273ix) Set of switches
274x) Set of wound resistors
275xi) Potentiometers
276xiii) Fuses of thyristor with indicators
27748 V, 800 AH VRLA Battery set along with accessories, stand and spares.
278Spare for 48 V, 800 AH VRLA Battery set
279i) Cells for 48 V bank
280ii) Connectors
281iii) Terminal lugs
28250 V, SMPS battery charger of 150 Amp. DC Load capacity alongwith additional one No. 25 SMPS Module.
283LT SWITCHGEAR
284AC DISTRIBUTION BOARD
285415 V, 1000 A, AC Main switch board
286415 V, 400 A, AC Distribution Board
287415 V, 400 A, Main lighting Distribution Board
288415 V, 200 A, Emergency lighting Distribution Board
2893 Phase, 415V, 800Amp. Changeover switch
290415 V, Air conditioning distribution panel
291SPARES
292MCCB of each rating
293MCB of each rating
294LT Breaker
295Spring Charging motor
296Aux. contact set
297Moving contacts set
298Fixed contacts set
299Spring closing / opening
300Closing Coil
301Tripping coil
302Aux. finger contacts
303Limit Switches
304Breaker Trolley
305Relays
306CTs and PTs
307DC DISTRIBUTION BOARD
308220 V, 400 A, DC Distribution Board (for 2 DC Sources in two parts with bus coupler)
30950 V, 200 A, DC Distribution Board (for 2 DC Sources in two parts with bus coupler)
310Spares
311MCCB of each rating
312MCB of each rating
313CT, PT (each type)
314Voltmeter and Ammeter (each type)
315Fuses (each type)
316Indicating bulbs
317Note:- ACDB & DCDB should be designed in such a manner so that each AC and DC feeder have duplicate connectivity.
318DG SET
319Diesel Generator set of stationary type having a net electrical out put of 160KVA capacity at specified site conditions with all its accessories for installation at 400 kV substation
320Spares for DG Set
321i) Set of filters
322ii) Solenoid coil assembly
323iii) Self starter assembly
324iv) Lub oil pressure safety control
325v) High water temp. safety control
326vi) AVR card for each type of DG set
327HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
328400 kV Double Tension String assembly with double anchoring points with 25 Nos. 160KN antifog type disc insulator/ composite long rod insulator per string with all hardware accessories including corona ring, turn buckle, arcing horn and tension clamp set suitable for Twin / quadruple Moose ACSR bundle with 450 mm sub-conductor spacing.(with/ without turn Buckle)
329400 kV Single Suspension string insulator assembly with 25 Nos. 120KN anti fog type disc insulators/ composite long rod insulator with all hardware accessories including corona ring with dropper / through type clamp set for Twin / quadruple Moose ACSR with 450 mm sub-conductor spacing..(drop/through type)
330245 kV double tension string assembly with single anchoring points with 15 Nos. anti fog type disc per string with all hardware accessories, including corona ring, turn buckle, arching horn and tension clamp set suitable for Twin/Quadruple Moose with 300mm sub conductor spacing.(with/ without turn Buckle)
331245 kV single suspension string insulator assembly with 15 Nos. anti fog type disc insulators with all hardware accessories including corona ring, arching horn and suitable for through / drop clamp set for Twin/Quadruple Moose bundle with 300mm sub conductor spacing..(drop/through type)
332245 kV Single tension string assembly with single anchoring points with 15 Nos. anti fog type disc per string with all hardware accessories, including corona ring, turn buckle, arching horn and tension clamp set suitable for Single Zebra (with/ without turn Buckle)
333245 kV single suspension string insulator assembly with 15 Nos. anti fog type disc insulators with all hardware accessories including corona ring, arching horn and suitable for through / drop clamp set for Single Zebra bundle. (drop/through type)
334a) 400 kV Bus Post Insulator stacks with corona ring other than those not included with individual equipment.
335b) 245 kV Bus Post Insulators other than those not included with individual equipment.
336c) 72.5 kV Outdoor Post Insulators other than those not included with individual equipment.
337400 kV Corona bellow / sphere for 4” & 3\\" IPS Al. tube
338a) 400 kV clamps and connectors other than those not included with individual equipment.
339b) 245 kV Clamps and Connectors other than those not included with individual equipment.
340c) 72.5 kV Clamps & Connectors other than those not included with individual equipment.
341d) All type clamp and connectors for earthwire and GS flat
342a) 400 kV Spacers(All types Rigid/Flexiable )
343a) 245 kV Spacers(All types Rigid/Flexiable )
344Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories
345EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
346(a) 40 mm dia MS Rod
347(b) 75X12mm GS Flat for risers
348(c ) 50x6 mm GS Flat for risers
349(d) 40 mm dia 3000 mm long MS rod (earth electrodes) with/without test links, RCC pits, C.I .cover hinged at C.I. frame alongwith all associated civil works
350(e) 40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
351Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
352a) 4” IPS (EH) Al. Tube (OD. 114.2 mm, Thickness-8.51 mm)
353b) 3” IPS (EH) Al. Tube (OD. 73.03mm Thickness 7.01mm)
354a) Welding sleeves for 4” IPS Al. tube
355a) Welding sleeves for 3” IPS Al. tube
356Earthwire tension clamps with D. Shackle assembly and earth bond
357Lugs to suit 10.98 mm GS Earthwire
358Junction boxes
359Marshalling Kiosk
360a) For 400 kV
361b) For 220 kV
362Cables (FRLS)
363(a)1.1 KV grade PVC insulated armoured control cables – Cu
364(b) 1.1 kV grade XLPE / PVC insulated armoured Al. conductor power cable
365Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
366Crimping type cable lugs (Tinned copper) of size of cable as required.
367PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
368Hume pipes for road crossing (NP-4 class). (Sizes shall be recommended by the bidder)
369Pressure die cast AL (LM6) Nylon 6 made trefoil clamp for recommended cables
370MS Angle Flat and ISMC channel (All size)
371ACSR Moose conductor
372ACSR Zebra
37310.98mm dia GS earth wire
37472.5 kV, 50 Amp. single phase horn gap fuse unit (Three phase)
375Heat shrinkable tube / tape
376Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
377Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
378IllUMINATION SYSTEM :
379Switchyard Flood Lighting
380Flood Light Luminaries
381Energy Efficent flood light complete in all respect
382Distribution pillars
383Cable Trays
384PVC Wires
385MCB’s
386Fibre Ladders (6/7 m)
387Mobile Flood Light Tower
388CONTROL ROOM BUILDING AND STREET LIGHTING
389Lighting transformers 100KVA
390Steel tubular poles with PVC wire JB , MCB, piller box complete cableling , panels etc complete in all respect
391Energy Efficent outdoor lights complete in all respect
392Fiber Ladder (3 Mtr)
393Any other items ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
394Spares
395Energy Efficent flood light complete in all respect
396Energy Efficent outdoor lights complete in all respect
397Capacitors of each rating
398MCCB each rating
399MCB of each rating
400Timer
401FIRE FIGHTING SYSTEM ( AS PER TECHNICAL SPECIFICATION)
402Mulsifyre System
403Diesel Engine driven pump set of 410 M3/hr capacity 70 M Head
404(a) Diesel engine pump complete with accessories
405(b) Foot valve with strainer 300 mm
406(c) Stop valve 250 mm
407(d) CIDF suction pipe 300 mm
408(e) Fittings
409(f) Diesel Engine Controller with VRLA Maintenance free Battery, SMPS charger complete
410Electric Motor driven pump set of 410 M3/hr capacity 70 M Head
411(a) Pump & motor complete with starter
412(b) Foot valve with strainer 300 mm
413(c) Stop valve 250 mm
414(d) CIDF suction pipe 300 mm
415(e) Fittings
416Air Vessel size 300 mm dia 1500 mm long
417Set of interconnecting pipes, stop valves for interconnecting in pump house building
418(a) 250 mm dia Gate valve
419(b) 250 mm dia Steel pipe
420Mulsifyre Strainer
421Automatic starter, Diesel Engine starting panel
422Compressor with driving motor
423G.I. piping with fittings
424(a) G.I. pipe 25 mm dia
425(b) Fittings for 25 mm dia pipe
426M.S. pipes suitable for overground and under ground as per relevant BIS
427(a) 250 mm dia pipe.
428(b) Fittings for 250 mm dia pipe
429(c) 200 mm dia pipe.
430(d) Fitting for 200 mm dia pipe
431(e) 150 mm dia pipe.
432(f) Fittings for 150 mm dia pipe
433(g) 100 mm dia pipe.
434(h) Fittings for 100 mm dia pipe.
435Set of Deluge valve stop valves, supports projectors, detectors with pipe, alarm motor and gang for the mulsifyre protection of 500 MVA transformer
436(a) Mulsifyre projectors
437(b) Quartzoid bulb Detectors
438(c) 150 mm dia Deluge valve
439(d) 250 mm dia Drain valve
440(e) 150 mm dia GI pipe
441(f) 100 mm dia GI Pipe
442(g) 80 mm dia GI Pipe
443(h) 50 mm dia GI Pipe
444(i) Alarm Motor & Gonge
445(j) D.A. Switches
446Alarm & 32 section Annunciation panel for complete installation
447LT distribution Panel suitable for 3 ½ x 300 sq. mm. incoming & 6 Nos. 3 ½ x185 / 95 Sqmm for 3 Phase outgoing feeders of capacity meeting the requirement of each motor
448Power Cables & Control Cables
449(a) 3 ½ x 300 Sqmm FRLS Cabler
450(b) 3 ½ x 185 Sqmm FRLS Cable
451(c) 3 ½ x 95 Sqmm FRLS Cable
452(d) 3x30 sq. mm. FRLS cable
453(e) Control cable (Copper)
454(f) Earthing
455Note :- BOQ shown above is indicate only. It shall be finalized at the time of detail engineering as per the specification / requirement
456Hydrant System
457Electric Motor driven pump set of 410 M3/hr capacity 70 M Head
458Electric pump motor & starter complete
459Foot valve with strainer
460Stop valve & size
461CIDF suction pipe & size
462Fittings
463Pump & infeed piping with automatic priming arrangement
464Air vessel of 300 mmdia 1.5 metre long
465Set of pipes & valves
466Check valve & size
467Gate valve & size
468Steel pipe 7 size
469Elbow & size
470Electric Control Panel including switchgear & wiring for manual and automatic start / stop of pumps
471Ring main with pipes and fittings
472150mm dia CITJ pipe / MS pipe
473Fittings of 150mm dia pipe
474100 mm dia CITJ pipe / MS pipe
475Fittings of 100mm dia pipe
476Hydrant Female Oblique type with stand pipe
477Single headed stand pipe
478Double Headed stand pipe
479Gun metal landing valve
480150mm dia Isolator valves
48163mm dia 15M long hose pipe
482Hose cabinets
483Branch pipe & jets
484Fog type Nozzle
485Any other specified item for completion of Hydrant system ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
486Note :- BOQ shown above is indicate only. It shall be finalized at the time of detail engineering as per the specification / requirement
487FIRE DETECTION AND ALARM SYSTEM
488Micro-processor based Main fire detection control panel wired for suitable number of zones complete with control unit P.S. system, built in a battery and battery charger
489Addressable Photo Electronic light scattered smoke detectors
490Addressable Photo Electronic light scattered smoke detectors with duct caging
491Addressable lonization chamber smoke detector
492Linear Heat sensor cable
493Heat Detector
494Electronic Hooters
495FRLS Control cables
4962x1.5 sq.mm
49710x1.5 sq.mm
498NOTE :- Quantities of each item shall be finalized during approval of detailed engineering for respective substations. Capacity of may vary as per IS.
499HAND APPLIANCES
500Pressurized, water type portable fire extingusher of 9 litre capacity complete with fill
501Dry chemical powder type portable fire extingusher of 5 Kg. capacity complete with fill
502Carbon di-oxide type portable fire extinguisher of 4.5 Kg. capacity complete with fill.
503Fire Bucket with Stand
504NOTE :- Quantities of each item shall be finalized during approval of detailed engineering for respective substations. Capacity of may vary as per IS.
505SPARES FOR MULSIFYRE / HYDRANT SYSTEM
506HVW – Pumps & Jockey pump
507a)Shaft-Sleeve
508b)Gland packing
509Diesel Engine drive
510a)Fuel oil filter
511b)Lubricating oil filter
512Nozzles (10% of total)
513Quartzoil Detectors
514Level Switch
515Pressure Switch
516Hydrant Valve
517SPARES FOR FIRE ALARM
518Smoke Detectors (10% of total)
519Photo electric type (10% of total)
520Ionization type (10% of total)
521Heat Detectors (10% of total)
522AIR-CONDITIONING AND VENTILATION SYSTEM WHICH SHALL INCLUDE FOLLOWING
523Design, supply, installation, testing and commissioning of Air conditioning & ventilation system for the control room building for following rooms alongwith the necessary spares for satisfactory operation for 5 (five) years.
524i) Control Room and OLTE / SAS Panel Room
525ii SE / XEN Room
526iii) Battery Room
527iv) Staff room, Rest Rooms etc.
528Design, supply, installation, testing and commissioning of Air conditioning & ventilation system for all kiosks of bay level units in switchyard as per Section-II Vol-II (Air conditioning)alongwith the necessary spares for satisfactory operation for 5 (five) years.
529STRUCTURES :Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
530LATTICE STRUCTURE
531Lignting Mast 24 m Height
532Tower (400 kV) MKD TC
533Tower (400 kV) MKD TH
534Tower (400 kV) MKD TJ
535Tower (400 kV) MKD TN
536Tower (400 kV) MKD TL
537Girder (400 kV) MKD G1
538Girder (400 kV) MKD G2
539220 kV tower type AT4
540220 kV tower type AT8 (A6 With Peak)
541220 kV tower type AT6 (Without Peak)
542220 kV tower type AT1
543220 kV Beam type AB1 / AB2
544400 kV C.T. Support Structure
545220 kV C.T. Support Structure
546Pipe structures
547400 kV CVT
548220 kV CVT
549400 kV Surge Arrestor
550220 kV Surge Arrestor
551400 kV Isolator
552220 kV Isolator
553400 kV Wave Trap
554220kV Wave Trap
555400 kV BPI
556220 kV BPI
55772.5 kV Isolator
55842kV, 52 class Lightning arresters
55936kV, 52 class EMVT (3 phase)
56072.5 kV Horn gap fuse (3 phase)
56172.5 kV Post insulators
562Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification.(2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
563TESTING AND MEASURING EQUIPMENTS
56450 k-Ohms Earth Tester
565Insulation Tester / Meggar (5 kV)
566Digital Multi-meter
567Digital Clamp Meter(Low range)
568Analog Multi-meter
569Universal Computerized Relay Test Kit alongwith Laptop (i7, 1.8 GHz, 14” TFT, 1 TB HDD, 8 GB Ram, DVD R/W) and associated configuration software
570Dew Point Meter
571Contact Resistance Meter
572Three Phase Transformer Turn Ratio Tester Meter
573SF6 Gas Leakage Detector
574Circuit Breaker Analyzer
575Portable Primary Injection Test kit
576Digital Clamp Meter(High range)
577Low Range Digital Tong Tester (0.1mA to 300A)
578GENERAL TOOLS & TACKLES
579Vacuum Cleaner
580Ring Spanner Set
581Tube Spanner Set
582Pipe Wrench 24”
583Pipe Wrench 18”
584Heavy Duty Drilling Machine
585Rechargable Torch
586Insulated cutting plier 12”
587Insulated cutting plier 8”
588Line live tester
589Screw Driver 18”
590Screw Driver 12”
591Hammer 8 lbs
592Hammer 2 lbs
593Allen keys
594Box spanner Set
595Screw Driver Set
596Hydraulic Crimping Tool up tp 630 Sq mm.
597OFFICE & MISCELLANEOUS EQUIPMENTS / ITEMS
598Furniture for Control Room building
599Junior executive table with three drovers on right side One Cup board left side with prelaminated decolam top 20mm thick over painted M.S. Frame ( 4 ½ feet x 2½ feet x 2½ feet) )
600Control Desk Type Table for Control room accommodating the Main and Redundant Computer System monitors, Workstations, printer, Logger, Maintenance / Engineering Terminal, telephone etc.(Size, Shape, Colour etc. to be got approved from Owner)
601Steel tubular chair “S” type with continuous and one feet dia 14 gauge pipe, cane seat backing, teak wood with quality cane.
602Five Leg Revolving Chair with arms
603Steel Almirah of size 6½ feetx3 feet x 19 inch with four shelves making five compartments in 18 guage with three way locking system
604Steel Almirah (With Glass door) of size 6½ feetx3 feet x 19 inch with four shelves making five compartments in 18 guage with three way locking system
605Minor Almirah of size 4½ feet x 30 inch x 17 inch with three shelves making four compartments in 18 guage with three waylocking system
606Steel rack of size 5 feet x 3 feet x 16 inches with six shelves making five compartments (22 guage)
607Steel stools of size 15 inch x 15 inch x 18 inch square pipe 16 guage
608Short bench of 4 feet x 14 inch x 1 ½ inch with laminated top.
609Steel waste paper baskets of size 12 inch x 10 inch x 10 inch
610Canopy 6 x 6 x 7 Ft with stand
611Camping Folding Chair Outdoor Garden,
612Key board (wooden)
613First Aid box
614Shock Treatment Chart
615REFRIGERATOR
616Micro Wave
6171800 W Induction Cooktop
618Substation Glow sign board Size and Colour etc. to be got approved from owner)
619Danger Plate (Size and colour etc. to be got approved from owner)
620Insulated mat (SMC Chequered ) (5m x 1m x3mm)
621Insulation Rubber Gloves (15 kV Tested)
622SAFETY HELMETS
623EARTHING ROD
624COMPUTER & Printer
625Desktop Computer
626Laser Printer
627Solar panel system complete 100 KW
628Solar panel system complete 100 KW with all necessary T&P. Cable, Meter, Structure etc.
62933 KV Underground Cable (0.75 Km) at 3CX300 Sq. mm with associated bay equipments at the other end
630Any Other item required for successful completion of work
631MAIN MATERIAL/ ITEMS
632500 MVA, 400/220/33 kV auto transformer
633400/220/33 kV, 500 MVA Auto Transformer with online drying system and all accessories (excluding transformer Oil) as per technical specification
634Insulating Oil for 500 MVA 400/220/33 kV Auto Transformer
635Digital RTCC Panel consisting of Digital RTCC relay as per technical Specification for transformers
636Optical Temprature Sensors alongwith measuring Units alongwith all associated accessories/ Fittings as per specification requirements for installation on all the Auto Transformers
637On-Line Dissolved Gas and Moisture Analyzer as per specification
63833 kV Neutral Current Transformer
63933/.433 kV, 800 kVA, LT three phase transformer
64033/.433 kV,800 kVA, LT three phase transformer complete with all fittings, accessories and associated equipment as per specification.
64133/.433 kV, 630 kVA, LT three phase transformer
64233/.433 kV, 630 kVA, LT three phase transformer complete with all fittings, accessories and associated equipment as per specification.
643Circuit Breaker
644420 kV,3150 Amp., 63 kA rupturing capacity circuit Breaker with closing resistor suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
645Terminal Connectors for above item
646420 kV, 3150 Amp.,63 kA rupturing capacity circuit Breaker without closing resistor, suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
647Terminal Connectors for above item
648Microprocessor based point of wave controller for above item [CSD]
649245 kV, 2000 Amp., 50 kA rupturing capacity circuit Breaker suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
650Terminal Connectors for above item
651Current Transformer
6523000-2000-1000/1 Amp., 63 kA 420 kV single phase multi core current transformers (Live Tank Type only) with 120% extended current rating
653Terminal Connectors for above item
6542000-1000-500/1-1-1-1-1 Amp., 50 kA 245 kV single phase multi core current transformers (Live Tank Type only)
655Terminal Connectors for above item
656Capacitive Voltage Transformer
657420 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 400/0.11 kV and three secondary windings.
658Terminal Connectors for above item
659245 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 220/0.11 kV and three secondary windings.
660Terminal Connectors for above item
66136kV, 52kV class EMVT
662Terminal Connectors for above item
663Isolator
664420 kV 3150, 63 kA Amp. triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
665Terminal Connectors for above item
666Post insulators for above item
667420 kV 3150 Amp, 63 kA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
668Terminal Connectors for above item
669Post insulators for above item
670245 kV 2000 Amp., 50KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic without earth blade complete with all accessories.
671Terminal Connectors for above item
672Post insulators for above item
673245 kV 2000 Amp.,50 KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
674Terminal Connectors for above item
675Post insulators for above item
676245 kV 2000 Amp., 50 KA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
677Terminal Connectors for above item
678Post insulators for above item
679245 kV 2000 Amp. 50 KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic for tandem operation complete with all accessories.
680Terminal Connectors for above item
681Post insulators for above item
68272.5 kV , 800 Amp. , triple pole, gang operated, horizontal double break type Isolator without earth switch alongwith complete metallic and accessories.
683Terminal Connectors for above item
684Post insulators for above item
68533kV/72.5kV D.O. Fuse Set
686Terminal Connectors for above item
687Post insulators for above item
688Surge Arresters
689Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 390 kV lightning arresters suitable for connection between phase and ground on 3 phase 420 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
690Terminal Connectors for above item
691Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 198 kV lightning arresters suitable for connection between phase and ground on 3 phase 245 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
692Terminal Connectors for above item
69342 kV, 52kV class Lightning arresters
694Terminal Connectors for above
695Wave Trap
696400 kV, 1.0mH / 3150 A. Wave Traps Pedestal mounting type with tuning unit, protection device, terminals clamps, corona rings, bird barriers etc.
697220 kV, 0.5 mH / 2000 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end.
698CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
699400kV Relay Panel for line with auto reclose scheme Type-SAS-FRC
700400kV Relay Panel for 500MVA, 400/220kV Transformer Type-SAS-THRC
701400kV Relay Panel for Tie Breaker with auto reclose scheme and common relay panel Type-SAS-BTRC
702220kV Relay Panel for feeder Type-SAS-FRB
703220kV Relay Panel for 500MVA, 400/220kV Transformer Type-SAS-TLRC
704220kV Relay Panel for Transfer Bus Coupler Type-BCRB
705400kV Control Panel for line with auto reclose scheme Type-SAS-FCC
706400kV Control Panel for 500MVA, 400/220kV Transformer Type-SAS-THCC
707400kV Control Panel for Tie Breaker with auto reclose scheme and common Control panel Type-SAS-BTCC
708220kV Control Panel for feeder Type-SAS-FCB
709220kV Control Panel for 500MVA, 400/220kV Transformer Type-SAS-TLCC
710220kV Control Panel for Transfer Bus Coupler Type-SAS-BBCB
711Bus Bar Protection Scheme having one no. central unit and 16 nos. peripheral units (PU) considering all existing and future dia of 400kV Switchyard designed for one & half breaker scheme (IEC-61850 Compliant).
712Bus Bar Protection Scheme having one no. central unit and 20 nos. peripheral units (PU) considering all existing and future bays of 220kV Switchyard designed for double main and transfer bus scheme with sectionalizer (IEC-61850 Compliant).
713GPS with Digital clock
714Necessary software and hardware alongwith laptop to up / down load the data / from the relays from / to the laptop. The supply of laptop is covered under this scope.
715SUBSTATION AUTOMATION SYSTEM
716Complete substation automation system alongwith necessary spares for 5 years satisfactory operation as per scope of the specification.
717Supply of Ethernet Switch, OFC, BCU, IEDs etc. to complete the scope specification .
718Phaser Measurement Unit
719Phaser Measurement Unit along with fibre optic connectivity, Global positioning system receiver and communication equipment
720PLCC EQIPMENTS
7214 Channel, Digital PLCC Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.
722A.F. Protection coupler microprocessor based suitable for Four commands.
723VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
724Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
725HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
726PLCC Electronic Private Automatic Exchange (EPAX) suitable for 24 subscribers lines and 16 tie lines with redundancy of critical cards.
727Telephone Sets (Push Button Type)
72810 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.63 mm.
7295 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.63 mm.
7305 Pair jelly filled unarmoured telephone cable having copper conductor of Dia. 0.5 mm.
731Copper cables 4x6 sq mm for PLCC (2 Run)
732Sleeved copper wire of 8 SWG.
733Any other item bidder may require to complete the PLCC System as per specification's requirements.( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
734FOTE TERMINAL EQUIPMENTS
735Fully wired cabinet with base 19” equipment rack (incl. front cover, cable tray, common cards) with fan unit and control, synchronization, Alarm, dual Power supply input cables
736Central Processing Card – CPU
737Power supply unit – 48 VDC 85 W
738OLTE – 4 Port STM-4/16 Card along with SFPs U4.2, U 16.2
739Optical Amplifier / Booster equipment (comprising of wave length translator, Wavelength Converter, Booster Amplifier; 21 dBm, Pre Amplifier and Raman Amplifier + Software) for main as well as protected parts
740OFC Patch Cords (Set of 48 nos.)
7418 Port 2w/4w E&M interface Card
7424 port Data Interface Card (Programmable)
7434 Port Data interface Card (Programmable) for remote end (to be located at nearest SLDC / Sub-LDC)
744Ethernet over SDH transport card (with four 10/100 base, one 100Base – FX and one 1000 Base-LX/SX front interfaces)
7454 command integrated Tele-protection Card
746MPLS TP Interface card
747Engineering Order Wire Phone
748Craft Terminal (LAPTOP PC) with element manager software
749Optical Fibre Distribution Panel (for 48 fibre) with spleing and patch parul
750Optical Fibre Distribution Panel (for 96 fibre) with spleing and patch parul
751Interface Cable for Power, Data, Voice, Tele-protection, Time Synchronizing etc. as per respective site requirement
752Approach Cable and necessary joint box for OPAW
7531G MPLS IP connectivity (ring topology) comprising IEC 104 data transmission through DCU, VOIP phone (Complitable for integration with existing CISCO make(ASR-900) MPLS)
754HDPE Duct Pipe for OPGW
755BATTERY AND BATTERY CHARGER
756220 V, 600 AH Tubular Lead Acid Battery set along with accessories, stand etc.
757220V, 100Amp/70Amp float cum boost Battery Charger (Separate sections for float and boost charging operation).
75848 V, 800 AH VRLA Battery set along with accessories, stand and spares.
75950 V, SMPS battery charger of 150 Amp. DC Load capacity alongwith additional one No. 25 SMPS Module.
760LT SWITCHGEAR
761AC DISTRIBUTION BOARD
762415 V, 1000 A, AC Main switch board
763415 V, 400 A, AC Distribution Board
764415 V, 400 A, Main lighting Distribution Board
765415 V, 200 A, Emergency lighting Distribution Board
7663 Phase, 415V, 800Amp. Changeover switch
767415 V, Air conditioning distribution panel
768DC DISTRIBUTION BOARD
769220 V, 400 A, DC Distribution Board (for 2 DC Sources in two parts with bus coupler)
77050 V, 200 A, DC Distribution Board (for 2 DC Sources in two parts with bus coupler)
771Note:- ACDB & DCDB should be designed in such a manner so that each AC and DC feeder have duplicate connectivity.
772DG SET
773Diesel Generator set of stationary type having a net electrical out put of 160KVA capacity at specified site conditions with all its accessories for installation at 400 kV substation
774HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
775400 kV Double Tension String assembly with double anchoring points with 25 Nos. 160KN antifog type disc insulator/ composite long rod insulator per string with all hardware accessories including corona ring, turn buckle, arcing horn and tension clamp set suitable for Twin / quadruple Moose ACSR bundle with 450 mm sub-conductor spacing.(with/ without turn Buckle)
776400 kV Single Suspension string insulator assembly with 25 Nos. 120KN anti fog type disc insulators/ composite long rod insulator with all hardware accessories including corona ring with dropper / through type clamp set for Twin / quadruple Moose ACSR with 450 mm sub-conductor spacing..(drop/through type)
777245 kV double tension string assembly with single anchoring points with 15 Nos. anti fog type disc per string with all hardware accessories, including corona ring, turn buckle, arching horn and tension clamp set suitable for Twin/Quadruple Moose with 300mm sub conductor spacing.(with/ without turn Buckle)
778245 kV single suspension string insulator assembly with 15 Nos. anti fog type disc insulators with all hardware accessories including corona ring, arching horn and suitable for through / drop clamp set for Twin/Quadruple Moose bundle with 300mm sub conductor spacing..(drop/through type)
779245 kV Single tension string assembly with single anchoring points with 15 Nos. anti fog type disc per string with all hardware accessories, including corona ring, turn buckle, arching horn and tension clamp set suitable for Single Zebra (with/ without turn Buckle)
780245 kV single suspension string insulator assembly with 15 Nos. anti fog type disc insulators with all hardware accessories including corona ring, arching horn and suitable for through / drop clamp set for Single Zebra bundle. (drop/through type)
781a) 400 kV Bus Post Insulator stacks with corona ring other than those not included with individual equipment.
782b) 245 kV Bus Post Insulators other than those not included with individual equipment.
783c) 72.5 kV Outdoor Post Insulators other than those not included with individual equipment.
784400 kV Corona bellow / sphere for 4” & 3\\" IPS Al. tube
785a) 400 kV clamps and connectors other than those not included with individual equipment.
786b) 245 kV Clamps and Connectors other than those not included with individual equipment.
787c) 72.5 kV Clamps & Connectors other than those not included with individual equipment.
788d) All type clamp and connectors for earthwire and GS flat
789a) 400 kV Spacers(All types Rigid/Flexiable )
790a) 245 kV Spacers(All types Rigid/Flexiable )
791Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories
792EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
793(a) 40 mm dia MS Rod
794(b) 75X12mm GS Flat for risers
795(c ) 50x6 mm GS Flat for risers
796(d) 40 mm dia 3000 mm long MS rod (earth electrodes) with/without test links, RCC pits, C.I .cover hinged at C.I. frame alongwith all associated civil works
797(e) 40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
798Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
799a) 4” IPS (EH) Al. Tube (OD. 114.2 mm, Thickness-8.51 mm)
800b) 3” IPS (EH) Al. Tube (OD. 73.03mm Thickness 7.01mm)
801a) Welding sleeves for 4” IPS Al. tube
802a) Welding sleeves for 3” IPS Al. tube
803Earthwire tension clamps with D. Shackle assembly and earth bond
804Lugs to suit 10.98 mm GS Earthwire
805Junction boxes
806Marshalling Kiosk
807a) For 400 kV
808b) For 220 kV
809Cables (FRLS)
810(a)1.1 KV grade PVC insulated armoured control cables – Cu
811(b) 1.1 kV grade XLPE / PVC insulated armoured Al. conductor power cable
812Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
813Crimping type cable lugs (Tinned copper) of size of cable as required.
814PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
815Hume pipes for road crossing (NP-4 class). (Sizes shall be recommended by the bidder)
816Pressure die cast AL (LM6) Nylon 6 made trefoil clamp for recommended cables
817MS Angle Flat and ISMC channel (All size)
818ACSR Moose conductor
819ACSR Zebra
82010.98mm dia GS earth wire
82172.5 kV, 50 Amp. single phase horn gap fuse unit (Three phase)
822Heat shrinkable tube / tape
823Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
824Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
825IllUMINATION SYSTEM :
826Switchyard Flood Lighting
827Flood Light Luminaries
828Energy Efficent flood light complete in all respect
829Distribution pillars
830Cable Trays
831PVC Wires
832MCB’s
833CONTROL ROOM BUILDING AND STREET LIGHTING
834Lighting transformers 100KVA
835Steel tubular poles with PVC wire JB , MCB, piller box complete cableling , panels etc complete in all respect
836Energy Efficent outdoor lights complete in all respect
837Any other items ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
838FIRE FIGHTING SYSTEM ( AS PER TECHNICAL SPECIFICATION)
839Mulsifyre System
840Diesel Engine driven pump set of 410 M3/hr capacity 70 M Head
841(a) Diesel engine pump complete with accessories
842(b) Foot valve with strainer 300 mm
843(c) Stop valve 250 mm
844(d) CIDF suction pipe 300 mm
845(e) Fittings
846(f) Diesel Engine Controller with VRLA Maintenance free Battery, SMPS charger complete
847Electric Motor driven pump set of 410 M3/hr capacity 70 M Head
848(a) Pump & motor complete with starter
849(b) Foot valve with strainer 300 mm
850(c) Stop valve 250 mm
851(d) CIDF suction pipe 300 mm
852(e) Fittings
853Air Vessel size 300 mm dia 1500 mm long
854Set of interconnecting pipes, stop valves for interconnecting in pump house building
855(a) 250 mm dia Gate valve
856(b) 250 mm dia Steel pipe
857Mulsifyre Strainer
858Automatic starter, Diesel Engine starting panel
859Compressor with driving motor
860G.I. piping with fittings
861(a) G.I. pipe 25 mm dia
862(b) Fittings for 25 mm dia pipe
863M.S. pipes suitable for overground and under ground as per relevant BIS
864(a) 250 mm dia pipe.
865(b) Fittings for 250 mm dia pipe
866(c) 200 mm dia pipe.
867(d) Fitting for 200 mm dia pipe
868(e) 150 mm dia pipe.
869(f) Fittings for 150 mm dia pipe
870(g) 100 mm dia pipe.
871(h) Fittings for 100 mm dia pipe.
872Set of Deluge valve stop valves, supports projectors, detectors with pipe, alarm motor and gang for the mulsifyre protection of 500 MVA transformer
873(a) Mulsifyre projectors
874(b) Quartzoid bulb Detectors
875(c) 150 mm dia Deluge valve
876(d) 250 mm dia Drain valve
877(e) 150 mm dia GI pipe
878(f) 100 mm dia GI Pipe
879(g) 80 mm dia GI Pipe
880(h) 50 mm dia GI Pipe
881(i) Alarm Motor & Gonge
882(j) D.A. Switches
883Alarm & 32 section Annunciation panel for complete installation
884LT distribution Panel suitable for 3 ½ x 300 sq. mm. incoming & 6 Nos. 3 ½ x185 / 95 Sqmm for 3 Phase outgoing feeders of capacity meeting the requirement of each motor
885Power Cables & Control Cables
886(a) 3 ½ x 300 Sqmm FRLS Cabler
887(b) 3 ½ x 185 Sqmm FRLS Cable
888(c) 3 ½ x 95 Sqmm FRLS Cable
889(d) 3x30 sq. mm. FRLS cable
890(e) Control cable (Copper)
891(f) Earthing
892Note :- BOQ shown above is indicate only. It shall be finalized at the time of detail engineering as per the specification / requirement
893Hydrant System
894Electric Motor driven pump set of 410 M3/hr capacity 70 M Head
895Electric pump motor & starter complete
896Foot valve with strainer
897Stop valve & size
898CIDF suction pipe & size
899Fittings
900Pump & infeed piping with automatic priming arrangement
901Air vessel of 300 mmdia 1.5 metre long
902Set of pipes & valves
903Check valve & size
904Gate valve & size
905Steel pipe 7 size
906Elbow & size
907Electric Control Panel including switchgear & wiring for manual and automatic start / stop of pumps
908Ring main with pipes and fittings
909150mm dia CITJ pipe / MS pipe
910Fittings of 150mm dia pipe
911100 mm dia CITJ pipe / MS pipe
912Fittings of 100mm dia pipe
913Hydrant Female Oblique type with stand pipe
914Single headed stand pipe
915Double Headed stand pipe
916Gun metal landing valve
917150mm dia Isolator valves
91863mm dia 15M long hose pipe
919Hose cabinets
920Branch pipe & jets
921Fog type Nozzle
922Any other specified item for completion of Hydrant system ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
923Note :- BOQ shown above is indicate only. It shall be finalized at the time of detail engineering as per the specification / requirement
924FIRE DETECTION AND ALARM SYSTEM
925Micro-processor based Main fire detection control panel wired for suitable number of zones complete with control unit P.S. system, built in a battery and battery charger
926Addressable Photo Electronic light scattered smoke detectors
927Addressable Photo Electronic light scattered smoke detectors with duct caging
928Addressable lonization chamber smoke detector
929Linear Heat sensor cable
930Heat Detector
931Electronic Hooters
932FRLS Control cables
9332x1.5 sq.mm
93410x1.5 sq.mm
935NOTE :- Quantities of each item shall be finalized during approval of detailed engineering for respective substations. Capacity of may vary as per IS.
936AIR-CONDITIONING AND VENTILATION SYSTEM WHICH SHALL INCLUDE FOLLOWING
937Design, supply, installation, testing and commissioning of Air conditioning & ventilation system for the control room building for following rooms alongwith the necessary spares for satisfactory operation for 5 (five) years.
938i) Control Room and OLTE / SAS Panel Room
939ii SE / XEN Room
940iii) Battery Room
941iv) Staff room, Rest Rooms etc.
942Design, supply, installation, testing and commissioning of Air conditioning & ventilation system for all kiosks of bay level units in switchyard as per Section-II Vol-II (Air conditioning)alongwith the necessary spares for satisfactory operation for 5 (five) years.
943STRUCTURES :Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
944LATTICE STRUCTURE
945Lignting Mast 24 m Height
946Tower (400 kV) MKD TC
947Tower (400 kV) MKD TH
948Tower (400 kV) MKD TJ
949Tower (400 kV) MKD TN
950Tower (400 kV) MKD TL
951Girder (400 kV) MKD G1
952Girder (400 kV) MKD G2
953220 kV tower type AT4
954220 kV tower type AT8 (A6 With Peak)
955220 kV tower type AT6 (Without Peak)
956220 kV tower type AT1
957220 kV Beam type AB1 / AB2
958400 kV C.T. Support Structure
959220 kV C.T. Support Structure
960Pipe structures
961400 kV CVT
962220 kV CVT
963400 kV Surge Arrestor
964220 kV Surge Arrestor
965400 kV Isolator
966220 kV Isolator
967400 kV Wave Trap
968220kV Wave Trap
969400 kV BPI
970220 kV BPI
97172.5 kV Isolator
97242kV, 52 class Lightning arresters
97336kV, 52 class EMVT (3 phase)
97472.5 kV Horn gap fuse (3 phase)
97572.5 kV Post insulators
976Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification.(2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
977COMPUTER & Printer
978Desktop Computer
979Laser Printer
980Solar panel system complete 100 KW
981Solar panel system complete 100 KW with all necessary T&P. Cable, Meter, Structure etc.
98233 KV Underground Cable (0.75 Km) at 3CX300 Sq. mm with associated bay equipments at the other end
983TRAINING CHARGES :- Training for substation automation system (For the courses as per scope of the specification).
984Computer System Hardware (per person)
985Computer System Software (per person)
986Application Software (per person)
987HANDHOLDING CHARGES
988Lumpsum Charges for Handholding for 12 months from the date of Taking Over Certificate.
989Any Other item required for successful completion of work
990CIVIL WORKS
991GEO TECHNICAL INVESTIGATION
992Soil Investigation of substation / switchyard area as per technical specification.
993FOUNDATIONS :
994FOUNDATIONS :
995MAIN MATERIAL/ ITEMS
996Circuit Breaker
997245 kV, 2000 Amp., 50 kA rupturing capacity circuit Breaker suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
998Terminal Connectors for above item
999Current Transformer
10002000-1000-500/1-1-1-1-1 Amp., 50 kA 245 kV single phase multi core current transformers (Live Tank Type only)
1001Terminal Connectors for above item
1002Capacitive Voltage Transformer
1003245 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 220/0.11 kV and three secondary windings.
1004Terminal Connectors for above item
1005Isolator
1006245 kV 2000 Amp., 50KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic without earth blade complete with all accessories.
1007Terminal Connectors for above item
1008Post insulators for above item
1009245 kV 2000 Amp.,50 KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
1010Terminal Connectors for above item
1011Post insulators for above item
1012245 kV 2000 Amp., 50 KA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
1013Terminal Connectors for above item
1014Post insulators for above item
1015245 kV 2000 Amp. 50 KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic for tandem operation complete with all accessories.
1016Terminal Connectors for above item
1017Post insulators for above item
1018Spares for 245 kV Isolators
1019i) One complete pole with support insulator and motor operating mechanism excluding structure
1020ii) Copper contact fingers for male and female contacts.
1021iii) Open / close contactor assembly, timers, key interlock push button switch
1022iv) Limit switch and auxiliary switch
1023v) Motor housing bearing assembly
1024vi) Terminal pads and connectors
1025vii) Motor with gear assembly and bevel gear assembly
1026viii) Bearings
1027ix) Current carrying assembly
1028x) Interlocking coil
1029Surge Arresters
1030Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 198 kV lightning arresters suitable for connection between phase and ground on 3 phase 245 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
1031Terminal Connectors for above item
1032Wave Trap
1033220 kV, 0.5 mH / 2000 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end.
1034CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
1035220kV Relay Panel for feeder Type-SAS-FRB
1036220kV Control Panel for feeder Type-SAS-FCB
1037Bus Bar Protection-Bus Peripheral Unit
1038SUBSTATION AUTOMATION SYSTEM
1039Integration with existing substation automation system alongwith necessary spares for 5 years satisfactory operation as per scope of the specification.
1040PLCC EQIPMENTS (included in 400 KV GSS Sawaimadhopur Supply)
1041HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
1042245 kV Single tension string assembly with single anchoring points with 15 Nos. anti fog type disc per string with all hardware accessories, including corona ring, turn buckle, arching horn and tension clamp set suitable for Single Zebra (with/ without turn Buckle)
1043245 kV single suspension string insulator assembly with 15 Nos. anti fog type disc insulators with all hardware accessories including corona ring, arching horn and suitable for through / drop clamp set for Single Zebra bundle. (drop/through type)
1044b) 245 kV Bus Post Insulators other than those not included with individual equipment.
1045b) 245 kV Clamps and Connectors other than those not included with individual equipment.
1046d) All type clamp and connectors for earthwire and GS flat
1047Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories
1048EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
1049(a) 40 mm dia MS Rod
1050(b) 75X12mm GS Flat for risers
1051(c ) 50x6 mm GS Flat for risers
1052(d) 40 mm dia 3000 mm long MS rod (earth electrodes) with/without test links, RCC pits, C.I .cover hinged at C.I. frame alongwith all associated civil works
1053(e) 40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
1054Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
1055Earthwire tension clamps with D. Shackle assembly and earth bond
1056Lugs to suit 10.98 mm GS Earthwire
1057Junction boxes
1058Marshalling Kiosk
1059b) For 220 kV
1060Cables (FRLS)
1061(a)1.1 KV grade PVC insulated armoured control cables – Cu
1062(b) 1.1 kV grade XLPE / PVC insulated armoured Al. conductor power cable
1063Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
1064Crimping type cable lugs (Tinned copper) of size of cable as required.
1065PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
1066Hume pipes for road crossing (NP-4 class). (Sizes shall be recommended by the bidder)
1067Pressure die cast AL (LM6) Nylon 6 made trefoil clamp for recommended cables
1068MS Angle Flat and ISMC channel (All size)
1069ACSR Zebra
107010.98mm dia GS earth wire
1071Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
1072Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
1073STRUCTURES :Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
1074LATTICE STRUCTURE
1075220 kV tower type AT1
1076220 kV Beam type AB1 / AB2
1077220 kV C.T. Support Structure
1078Pipe structures
1079220 kV CVT
1080220 kV Surge Arrestor
1081220 kV Isolator
1082220kV Wave Trap
1083220 kV BPI
1084Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification.(2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
1085Any Other item required for successful completion of work
1086MAIN MATERIAL/ ITEMS
1087Circuit Breaker
1088245 kV, 2000 Amp., 50 kA rupturing capacity circuit Breaker suitable for single and three phase rapid auto reclosing complete with mounting structures, foundation bolts and nuts and first filling of SF6 gas plus 20% spare gas including accessories and auxiliaries.
1089Terminal Connectors for above item
1090Current Transformer
10912000-1000-500/1-1-1-1-1 Amp., 50 kA 245 kV single phase multi core current transformers (Live Tank Type only)
1092Terminal Connectors for above item
1093Capacitive Voltage Transformer
1094245 kV single phase 4400 pF CVT suitable for high frequency (HF) coupling required for power line communication with voltage ratio 220/0.11 kV and three secondary windings.
1095Terminal Connectors for above item
1096Isolator
1097245 kV 2000 Amp., 50KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic without earth blade complete with all accessories.
1098Terminal Connectors for above item
1099Post insulators for above item
1100245 kV 2000 Amp.,50 KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic fitted with single earth blade complete with accessories.
1101Terminal Connectors for above item
1102Post insulators for above item
1103245 kV 2000 Amp., 50 KA triple pole, gang operated horizontal double break type motor operated, outdoor Isolator metallic with double earth blade complete with accessories.
1104Terminal Connectors for above item
1105Post insulators for above item
1106245 kV 2000 Amp. 50 KA triple pole, gang operated Horizontal Double break type, motor operated, outdoor, Isolator metallic for tandem operation complete with all accessories.
1107Terminal Connectors for above item
1108Post insulators for above item
1109Surge Arresters
1110Single pole voltage -coordinated, outdoor station class heavy duty current limiting type 198 kV lightning arresters suitable for connection between phase and ground on 3 phase 245 kV neutral grounded system complete with insulating base, surge counter and current meter, accessories.
1111Terminal Connectors for above item
1112Wave Trap
1113220 kV, 0.5 mH / 2000 A Wave traps with tuning unit protection device, terminals clamps, corona rings, bird barriers etc. Including remote end.
1114CONTROL, RELAY & PROTECTION PANELS & ASSOCIATED MANDATORY SPARES/EQUIPMENTS
1115220kV Relay Panel for feeder Type-SAS-FRB
1116220kV Control Panel for feeder Type-SAS-FCB
1117Bus Bar Protection-Bus Peripheral Unit
1118SUBSTATION AUTOMATION SYSTEM
1119Integration with existing substation automation system alongwith necessary spares for 5 years satisfactory operation as per scope of the specification.
1120PLCC EQIPMENTS (included in 400 KV GSS Sawaimadhopur Supply)
1121HARDWARES AND MECHANICAL/ELECTRICAL AUXILIARIES
1122245 kV Single tension string assembly with single anchoring points with 15 Nos. anti fog type disc per string with all hardware accessories, including corona ring, turn buckle, arching horn and tension clamp set suitable for Single Zebra (with/ without turn Buckle)
1123245 kV single suspension string insulator assembly with 15 Nos. anti fog type disc insulators with all hardware accessories including corona ring, arching horn and suitable for through / drop clamp set for Single Zebra bundle. (drop/through type)
1124b) 245 kV Bus Post Insulators other than those not included with individual equipment.
1125b) 245 kV Clamps and Connectors other than those not included with individual equipment.
1126d) All type clamp and connectors for earthwire and GS flat
1127Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories
1128EARTHING MATERIAL (GS & MS flats of all sizes and Cu/Al Flexible braids)
1129(a) 40 mm dia MS Rod
1130(b) 75X12mm GS Flat for risers
1131(c ) 50x6 mm GS Flat for risers
1132(d) 40 mm dia 3000 mm long MS rod (earth electrodes) with/without test links, RCC pits, C.I .cover hinged at C.I. frame alongwith all associated civil works
1133(e) 40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
1134Note:- (i) The GS/MS flats to be used for earthing of the equipment shall be required to be drilled/welded at site as per the needs and M.S. Flats shall be properly painted as per the stipulations. Supply of necessary bolts, nuts & washers shall also be in the scope of the contractor. (ii) All the dropped jumpers shall be of Y-type.
1135Earthwire tension clamps with D. Shackle assembly and earth bond
1136Lugs to suit 10.98 mm GS Earthwire
1137Junction boxes
1138Marshalling Kiosk
1139b) For 220 kV
1140Cables (FRLS)
1141(a)1.1 KV grade PVC insulated armoured control cables – Cu
1142(b) 1.1 kV grade XLPE / PVC insulated armoured Al. conductor power cable
1143Double compression type cable gland for 1.1 kV grade insulated cables & its termination as per cable sizes.
1144Crimping type cable lugs (Tinned copper) of size of cable as required.
1145PVC Pipes for Laying cables as per IS 4985 (the sizes shall be recommended by the bidder)
1146Hume pipes for road crossing (NP-4 class). (Sizes shall be recommended by the bidder)
1147Pressure die cast AL (LM6) Nylon 6 made trefoil clamp for recommended cables
1148MS Angle Flat and ISMC channel (All size)
1149ACSR Zebra
115010.98mm dia GS earth wire
1151Any Other Item ( If amount quoted, list if items alongwith quantity be indicated in Technical offer)
1152Note:- Bidder shall supply 5% of the erected quantities of above Bus Bar Material, clamp connector, spacers and accessories as spare . Any fractions will mean the next higher integer number.
1153STRUCTURES :Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure. Conforming to IS:2062 and GI pipe conforming to grade YST 22 or higher grade as per IS:806.
1154LATTICE STRUCTURE
1155220 kV tower type AT1
1156220 kV Beam type AB1 / AB2
1157220 kV C.T. Support Structure
1158Pipe structures
1159220 kV CVT
1160220 kV Surge Arrestor
1161220 kV Isolator
1162220kV Wave Trap
1163220 kV BPI
1164Note:- (1)The above estimated quantities of structures are only for tender purpose. The contractor shall supply, erect & commission the structures to meet out complete requirement for successful commissioning , maintenance & operation of the substation in accordance with the specification.(2) Details of Tower structures & girders / beams available in Vol.II, of specification are tentative and for tender purpose only. The bidder shall have to design the structures & girders / beams based on actual loadings on the basis of short circuit force calculations, if required.
1165Any Other item required for successful completion of work
1166CIVIL WORKS
1167FOUNDATIONS : Please Enable Macros to View BoQ information
1168FOUNDATIONS : Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56324887
AUTHORITY Government Departments
TENDER VALUE 125.98 Crore
LAST DATE 05-08-2026
Authority
Authority Name Rajasthan Rajya Vidhyut Prasaran Nigam Limited
Work Description Tender for Construction Of 1 X 500 Mva, 400/220 Kv Sub-Station At Sawai Madhopur (Distt. - Sawai Madhopur) Alongwith 02 Nos., 220 Kv Bays At 220 Kv Gss Bhadoti Including Supply Of All Equipments/Materials, Erection (Including Civil Works), Testing And Commissioning (On Turnkey Basis)
Basic Detail
Tender No NIB/2026-27/BN9074002602
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 06 Jul 2026
Submission Date 05 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 125.98 Crore
Tender Fee 29500
EMD 2.51 Crore
Exemption Available
Document List
b9bd6bf4-dcc1-42fc-bbe2-be31d80544bf.html
BOQ_1019168.xls
Tendernotice_1.pdf
Vol-I_Commercial_SWM_GSS.pdf
Vol_III_SWM.pdf
Vol_II_SWM_Part1.pdf
Vol_II_SWM_Part2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 24 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

b9bd6bf4-dcc1-42fc-bbe2-be31d80544bf.html

xls

BOQ_1019168.xls

pdf

Tendernotice_1.pdf

pdf

Vol-I_Commercial_SWM_GSS.pdf

pdf

Vol_III_SWM.pdf

pdf

Vol_II_SWM_Part1.pdf

pdf

Vol_II_SWM_Part2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders