Power Government Departments Closing in 22 days TDR #56324881

Tender For Construction Of Lilo Of 400 Kv Hindaun-Chhabra Tps Line (Twin Moose) At Proposed 400 Kv Gss Sawai Madhopur= Length 22.0 Km Approx.

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
84.72 Crore
Estimated cost
Bid Submission
05 Aug 2026
22 days left
EMD
1.69 Crore
Bank guarantee accepted
Document Fee
23600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Lilo Of 400 Kv Hindaun-Chhabra Tps Line (Twin Moose) At Proposed 400 Kv Gss Sawai Madhopur= Length 22.0 Km Approx.

BOQ

Name of Work:- CONSTRUCTION OF LILO OF 400 KV HINDAUN-CHHABRA TPS LINE (TWIN MOOSE) AT PROPOSED 400 KV GSS SAWAI MADHOPUR= Length 22.0 Km Approx.
Sl. No. Item Description
1Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
2High Tensile Steel
3Mild Steel
4Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts, anti theft bolts & nuts and Spring Washers Etc. )
5River Crossing Tower: Fabrication, galvenizing and supply of special river crossing tower parts including stub/ base plate, anchor bolt, platforms, ladders, hangers, D-Schakles, gusset plates, pack plates & pack washers excluding bolts & nuts
6High Tensile Steel
7Mild Steel
8Supply of bolts & nuts including step bolts and spring washers etc.
9Hexagonal Bolts and Nuts for towers
10Supply of Earthing material of Towers
11Pipe Type
12Counterpoise Type
13Supply of following Tower Accessories
14Danger Plate
15Number Plate
16Phase Plate (Set of three)
17Circuit Plate
18Anti Climbing Device (Fork Type)
19Supply of following items for Aviation Requirements
20Span Marker
21Obstruction lights(To be proved as per IS:5613)
22a) 1 Medium + 2 Low intensity
23Design, manufacture and supply of following line material. ***11/kv 120KN
24i) Disc Insulators, or
25ii) Long Rod Insulators, or
26iii) Composite Long Rod Insulators
27Design, manufacture and supply of following line material. ***11/kv 160KN
28i) Disc Insulators, or
29ii) Long Rod Insulators, or
30iii) Composite Long Rod Insulators
31Hardware Fittings
32Single 'I' suspension H/W fittings armour grip type complete set suitable for Twin ACSR Moose conductor (suitable for 1x23, 120 KN Disc Insulators or 1x1 Long Rod Insulators or 1x1 Composite Long Rod Insulator).
33Single suspension H/W fittings conventional envelop type complete set suitable for Twin ACSR Moose conductor for pilot string (suitable for 1x23, 120 KN Disc Insulators or 1x1 Long Rod Insulators or 1x1 Composite Long Rod Insulator).
34Double 'I' suspension H/W fittings armour grip type complete set suitable for Twin ACSR Moose conductor (suitable for 2x23, 120 KN Disc Insulators or 2x3 Long Rod Insulators or 2x3 Composite Long Rod Insulator).
35Double tension H/W fittings compression type for Twin ACSR Moose conductor (suitable for 2x24, 160 KN Disc Insulators or 2x3 Long Rod Insulators or 2x3 Composite Long Rod Insulator).
36ACSR Moose Conductor
37Accessories for ACSR Moose Conductor
38Mid Span Compression Joint for ACSR Moose conductor
39Repair Sleeve for ACSR Moose conductor
40Vibration dampers for Twin ACSR 'MOOSE' conductor
41Line spacers with retaining rod for Twin ACSR Moose conductor
42Rigid Spacer for jumper for Twin ACSR Moose Conductor
43GSS Earthwire- size 7/3.66 mm
44Accessories for Earthwire
45Vibration Damper for 7/3.66 mm GS Earthwire
46Mid Span Compression Joint for 7/3.66 mm GS Earthwire
47Repair Sleeve for 7/3.66 mm GS Earthwire
48Suspension Clamp with flexible Copper Bond for 7/3.66 mm GS Earthwire
49Tension Clamp with flexible Copper Bond for 7/3.66 mm GS Earthwire
50Power Connector
51Counter Weight
52OPGW Cable
5348 Fibre (DWSM) OPGW fibre optic cable
54Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box**
55Joint box (48 Fibre)
56Any Other item required for successful completion of work
57Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. **One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW. ** Bidder will quote either for Disc or Long Rod or Composite Long Rod Insulator. In case of bidder quote for more than one types of insulators, then in evaluation, highest cost of insulators will be considered.
58Detailed Survey, including route alignment, profiling, tower optimization & spotting, check survey and Geotechnical Investigations etc.
59Land Identification and compensation
60For Scope of work as specified at Item No. a (i to iv) in Annexure-A (enclosed).
61For Scope of work as specified at Item No. b (i to iv) in Annexure-A (enclosed).
62Setting of Stub excluding cost of excavation and concreting but including back filling.
63(A) 400 kV D/C Towers.
64a) Tangent Tower TTA
65b) Small Angle Tension Tower TTB
66c) Medium Angle Tension Tower TTC
67d) Large Angle Tension Tower TTD
68e) Special/ River Crossing Tower
69Excavation excluding back filling, including shoring, shuttering, De-watering etc. for
70a) Normal Dry
71b) Wet/Sandy soil
72c) Soft/disintegrated rock
73d) Hard rock (blasting prohibited)
74e) Hard soil/ Soil mixed with boulders
75f) Wet Black Cotton Soil
76Excavation for benching and transportation of soil at a suitable place
77a) Normal Dry
78b) Wet/Sandy soil
79c) Soft/disintegrated rock
80d) Hard rock (blasting prohibited)
81e) Hard soil/ Soil mixed with boulders
82f) Wet Black Cotton Soil
83De-watering of pits during concerting
84a) Manual
85b) Mechanical pump
86c) Power driven pump
87Rock anchors as necessary including cost of drilling holes in rock, grouting reinforcement dowel bars etc. (complete including bottom plugging with contractor’s material as per approved drawings and specification.
88Cement Concrete M-20 (1:1.5:3)
89Providing and laying cement Concrete M-20 grade (1:1.5:3) with single sized aggregate of nominal size 20 mm including preparing surfaces, shuttering mixing, placing, temping curing and finishing with leads and lifts etc as per specification and drawings.
90Cement Concrete M-10 (1:3:6)
91Providing and laying cement Concrete M-10 grade (1:3:6) with single sized aggregate of nominal size 20 mm including preparing surfaces, shuttering mixing, placing, temping curing and finishing with leads and lifts etc as per specification and drawings.
92Steel Reinforcement
93Supply, Cutting, Bending, binding, welding of joints if required, fixing and placing of steel reinforcement of Fe 500 grade as per specification and drawings.
94Erection of all types of super structures towers, their extensions and special/river crossing towers etc. with its bolts, nuts and washers and bird guard etc.
95Erection of Tower Accessories
96a) Erection of Anti-climbing devices
97b) Fixing of Danger plate, Circuit Plates, Number plate and Phase plates etc.
98Conductor Stringing
99Mounting of insulators and stringing of six numbers twin bundle ACSR Moose conductor including laying, jointing, tensioning, sagging, clamping and fixing of all line accessories etc.
100Earthwire Stringing
101Stringing of one number 7/3.66 mm galvanised steel wire including laying, jointing, tensioning etc.
102Earthing of Transmission line Towers
103a) By pipe type earthing sets, excluding cost of all materials.
104a) By counterpoise earthing sets, excluding cost of all materials.
105Cement Concrete M-15 (1:2:4)
106Rates for Providing and laying cement concrete M-15 grade 1:2:4 with single sized aggregate of nominal size 20 mm including preparing surfaces, shuttering mixing, placing, temping curing and finishing with leads and lifts etc. as per specification and drawings.
107Rates for Dry stone revetment (including excavation back filling and levelling)
108Rates for Random stone masonary with cement sand mortar with (1:6) (including cement & back filling and levelling) by surplus excavation earth including pointing (flush and ruled type) with cement sand mortar 1:3
109Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 , curing etc.
110Cement concrete coping grade 1:2:4 ( 1 Cement :2 coarse sand :4 graded stone aggregate ) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75 mm thick with 20 mm thick nominal size aggregate
111Rates for Back filling and levelling of the volumes enclosed by the revetment walls with excavated earth at locations.
112Rates for Back-filling with borrowed earth
113i) Beyond 50 m upto 100 m
114ii) Beyond 100 m
115Tack welding of Bolts & Nuts up to bottom cross arm of the tower
116Erection, testing and commissioning of Aviation Warning Light System in accordance with IS-5613, with one medium and two low intensity aviation warning lights.
117Erection of globules (Day marking sphere) 600 mm dia conforming to the latest ICAO regulations suitable for clamping on stranded steel earthwire alongwith the clamp etc. complete in all respect.
118Painting of tower above 45m from ground level for Aviation purpose
119OPGW Cable and Accessories
120Stringing of 48 Fibre (DWSM) OPGW fibre optic cable
121Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box**
122Joint box (48 Fibre)
123Mounting of insulators and stringing of six Nos. twin bundle ACSR Moose conductor including laying, jointing, tensioning. Sagging, clamping and fixing of all line accessories and incuding Stringing of 48 Fibre (DWSM) OPGW fibre optic cable & one Nos. 7/3.66 mm galvanised steel wire including laying, jointing. tensioning etc. for RIVER CROSSING
124PILE FOUNDATION
125Detailed soil investigation for river crossing/pile foundation upto 40 mtr depth
126River Crossing Foundation (4 nos foundations for RIVER CROSSING Towers)
127Pile FoundationDesign, Boring, Providing and installation of bored Cast-in-situ RCC vertical piles of specified diameter and of any length below the pile cap with M25 grade of cement concrete excluding the cost of supply & placing the reinforcement steel but including the cost of boring with temporary guide casing, bentonite solution and the length of pile to be embeded in the pile cap (length of pile cap for payment shall be measured from bottom of pile cap), all necessary labour, materials, plants, tools & tackles etc complete as necessary for proper execution of the job.(Boring in weathered rock, shale, fissured rock and soft rock excluded)
128a) 1200 mm diameter RCC vertical bored pile from bottom of pile cap
129b) Extra over item a) for boring including socketing, anchoring (if required) with required size , nos & depth of Reinforcement in weathered rock, shale,fissured rock soft rock and hard rock upto a maximum depth of 5.0m.tr depth
130a) Supply & placing of steel reinforcement of FE 500 grade grade for RCC work in pile, pile cap, pedestal/chimney including straighting, cutting, bending, binding etc all complete incleuding placement upto 28 m depth and 5 meter height in chimney
131b) Supply & placing of 8MM Thick Liner
132a) Providing and laying in position M25 Grade concrete of specified 28 days strength for pile cap, pedestal/chimney,(including special arrangement like shoring shuttering and huge form work) & excavation.
133b) Lean Concrete M15 using 40MM Coarse Aggregate
134Conducting Integraty Test on piles using electronic control unit, hand held hammer, accelerometer, computer with required software to assess as-installed pile characteristics including mobilisation of necessary manpower, equipment, materials etc required
135Any Other item required for successful completion of work
136Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting aproval.**One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW/Approach Fibre Optic cable.
137Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
138High Tensile Steel
139Mild Steel
140Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
141Supply of Earthing material of Towers
142Pipe Type
143Counterpoise Type
144Supply of following Tower Accessories
145Danger Plate
146Number Plate
147Phase Plate (Set of three)
148Circuit Plate
149Design, manufacture and supply of following line material. **11/ kV 70KN
150i) Disc Insulators or
151ii) Long Rod Insulators
152Design, manufacture and supply of following line material. **11/ kV 120KN
153i) Disc Insulators or
154ii) Long Rod Insulators
155Hardware Fittings for ACSR Zebra Conductor
156Single Suspension H/W fittings for ACSR Zebra Conductor
157Single Tension H/W fittings for ACSR Zebra Conductor
158Double Suspension H/W fittings for ACSR Zebra Conductor
159Double Tension H/W fittings for ACSR Zebra Conductor
160ACSR Zebra Conductor (54/ 3.18 mm AL+7/ 3.18 mm Steel)
161Accessories for ACSR Zebra Conductor
162Mid Span Compression Joint for ACSR Zebra Conductor
163Repair Sleeve for ACSR Zebra Conductor
164Preformed Armour Rod for ACSR Zebra Conductor
165Vibration Damper for ACSR Zebra Conductor
166OPGW Cable
16748 Fibre (DWSM) OPGW fibre optic cable
168Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box**
169Joint Box (48 Fibre)
170Any Other item required for successful completion of work
171Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. **One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW.** Bidder will quote either for Disc or Long Rod Insulator. In case of bidder quote for more than one types of insulators, then in evaluation highest cost of insulators will be considered.
172DETAIL SURVEY AS PER TENTATIVE ROUTE- Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
173Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
174Land Identification and compensation
175For Scope of work as specified at Item No. a (i to iv) in Annexure-A (enclosed).
176For Scope of work as specified at Item No. b (i to iv) in Annexure-A (enclosed).
177Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
178(i) Any soil, soft rock other than hard rock
179(ii) Hard Rock (with blasting subject to permission or without blasting)
180SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
181Tower including extension upto 9 Meter
182Special towers for any span including extension
183CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
1841:3:6 Mix (M-10)
1851:2:4 Mix (M -15)
1861:1.5:3 Mix (M -20)
187Steel Reinforcement
188Supply, Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
189EARTHING:
190Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
191Earthing of towers legs with counterpoise typeearthings excluding supply of materialsbut including excavation and backfilling in all types of soil.(i) Each set by laying 4 wires each 15m long at a depth of 600 mm
192ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
193(i) Erection of tower (with extension upto 9 Meters)
194(ii) Erection of special towers(with extensions)
195CONDUCTOR STRINGING: Stringing of ACSR Zebra including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
196(i) Single Conductor
197(ii) Single Conductor for River Crossing
198REVETMENT OF TOWERS
199Providing & laying cement concrete including curing compaction etc. complete using stone aggregate 40 mm nominal size (Crusher broken) in foundation plinth using 1 cement : 5 sand : 10 Aggregate mix
200Random rubble stone massonary for rivetment in 1:5 cement sand mortat including providing and fixing 100 mm dia PCC drain pipe and raised and cut pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each depositing layer by ramming and watering.
201Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3, curing etc.
202Cement concrete coping grade 1:2:4(1cement:2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75 mm thick with 20mm thick nominal size aggregate
203Brick masonary in foundation & plinth with bricks of class designation 75 in cement mortar 1:5 (1 cement: 5 coarse sand)
204Brick on edge flooring with bricks of class designation 75 including pointing in cement mortar (l:3) complete laid on 12mm thick bed of cement sand mortar 1:6.
205STRINGING OF 48 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE
206Stringing of 48 Fibre (DWSM) OPGW fibre optic cable
207Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box
208Joint box (48 Fibre)
209Any Other item required for successful completion of work
210Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting aproval. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56324881
AUTHORITY Government Departments
TENDER VALUE 84.72 Crore
LAST DATE 05-08-2026
Authority
Authority Name Rajasthan Rajya Vidhyut Prasaran Nigam Limited
Work Description Tender for Construction Of Lilo Of 400 Kv Hindaun-Chhabra Tps Line (Twin Moose) At Proposed 400 Kv Gss Sawai Madhopur= Length 22.0 Km Approx.
Basic Detail
Tender No RVPN/EHV/BN-9074002601
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 06 Jul 2026
Submission Date 05 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 84.72 Crore
Tender Fee 23600
EMD 1.69 Crore
Exemption Not Available
Document List
6133877d-28fe-4ca9-962b-6bd9fc20bd7c.html
BOQ_1007876.xls
Tendernotice_1.pdf
Vol-II_Tech_Spec_220KV_Line.pdf
Vol-II_Tech_Spec_400KV_DC_1.pdf
Vol_I.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

6133877d-28fe-4ca9-962b-6bd9fc20bd7c.html

xls

BOQ_1007876.xls

pdf

Tendernotice_1.pdf

pdf

Vol-II_Tech_Spec_220KV_Line.pdf

pdf

Vol-II_Tech_Spec_400KV_DC_1.pdf

pdf

Vol_I.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders