Tender For Providing Air Conditioners In Community Centre, Sector-41, Chandigarh.
Tender Value
5.98 Lakhs
Estimated cost
Bid Submission
15 Jul 2026
8 days left
EMD
11964
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Air Conditioners In Community Centre, Sector-41, Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | Supply , Installation, Testing and Comissioning of 2.0 TR with 5 Star BEE Rating Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Make:Carrieer/Voltas/Hitachi/Daikin/Mitsubishi. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 2 | Supplying and fixing voltage stabilizer 5 KVA for AC of 2 Tn and above with MCB, TDR volt meter copper winding input range 180-250 volt single phase including cost of copper wire from stabilizer to A.C unit with M.S body of 22 gauge sheet powder coated). Cost includes 15A plug top. Make Deol/Jewel/ V-Guard with warranty of 2years. |
| 3 | Providing and fixing of 28 gauge copper piping between indoor & outdoor unit complete with sleeve type Kini insulation including the cost of chasing of brick wall, RCC & repairing the same in good conditions as per site requirement to the size & design of manufacture.size of copper pipe 5/8\\"x3/8\\". |
| 4 | Providing & Fixing PVC rigid drain pipe 20mm (3/4\\") dia of Diplast/ finolex/supreme make of complete in all respects from indoor unit to disposal points as directed by EIC. |
| 5 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole of make Havell's/ Standard/ABB/L&T/Schneider. |
| 6 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 7 | Providing and fiixing flexible copper conductor wires complete in all respects. Make Finolex/Polycab/Havells/BCH or its equivalent ISI marked 3 core 2.5 mm. |
| 8 | P/F of LED luminarie of size 2'x2' of 30-36 watt (595x595 mm) surface/recess type including driver with system Lumens 3600-4000 Im having efficacy of minimum 100 lm/W. THD <10%, PF > 0.95, Having coloured temperature 4000-6500 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame of make Havells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj alongwith connection, testing and commissioning erc. This job also includes all petty material required to be entire satisfaction of Engineer-in-charge. Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. |
| 9 | Supply & Erection of 1x18 watt retrofit LED tube rod with batten Supply & Erection of 1x18 watt retrofit LED tube rod with batten made of aluminium housing with PC diffuser Lumen out put should be more than 100 lumens per watt (1800 LUM) with LM 79 report from NABL. The make of the fittings should beHavells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj . The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 10 | Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | 3 pin 5/6 amp switch outlet DSR 1.24.1 |
| 12 | 15/16 amps switch outlet DSR1.24.3 |
| 13 | 3 pin 5/6 amp socket outlet DSR1.24.4 |
| 14 | 15/16 amps socket outlet DSR 1.24.5 |
| 15 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 16 | Supply and Erection of bakelite sheet of 3mm with cutting & making good etc. on the existing M.S. boxes with suitable size of screws & washers etc. The work shall be executed to the entire satisfaction of Engineer in charge. |
| 17 | S/E of Ceiling Fans 1400mm sweep without fan regulator including M.S. pipe as per site requirement and wiring complete in all respect Make Bajaj (Sabse Tej EE) including making connection with 23/.076' flexible wire to be adjacent fan point with regulator . The work shall be executed to the entire satisfaction of Engineer in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysJul 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer